Attention ETCR8600 Leakage Protector Tester To read this user manual carefully. To comply with the operating cautions presented in this manual.

Similar documents
目录

1.Safe testing IMPORTANT:

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

DIGITAL RCD(ELCB) TESTER

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

SafetyPAT Plus A B P/N:

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

User Guide. Model Insulation Tester / Megohmmeter

BM kv Digital Insulation Tester USER MANUAL

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

KTD30 Digital Insulation and Continuity Tester

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Model Insulation Tester / Megohmmeter. User Manual

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

User Guide. Model Insulation Tester / Megohmmeter. Introduction

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

OPERATING INSTRUCTION

User Guide. Model Insulation Tester / Megohmmeter

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

BATTERY OPERATED DIGITAL MILLI-OHMMETER

Digital Multimeter User's Manual

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Digital/Analog Megohmmeter Model 1026 USER MANUAL

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

User's Manual Digital High Voltage Insulation Tester Model

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Mini Multimeter with Non-Contact Voltage Detector (NCV)

PAT120, PAT150 and PAT150R

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

MIT300 Series Insulation and Continuity Testers

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Safety design conforming to the following provisions

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Digital/Analog Megohmmeter Model 1026

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

323/324/325 Clamp Meter

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

OPERATING INSTRUCTION

Megohmmeter Test Probe

KEWTECH. KT56 digital multi function tester. Instruction manual

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

3 PHASE TESTER & MOTOR ROTATION TESTER

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Instruction Manual. Model 310 Digital Milli-Ohm Meter

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

362 Clamp Meter. Users Manual

5.2 PRE-OPERATION PROCEDURE WARRANTY

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

Specification Approval Sheet

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

ETHOS Digital Sound Level Meter. Operating Manual

OPERATING INSTRUCTIONS

Ground Resistance Tester Model 3620 & 3620 Kits

Digital Insulation Resistance Testers. you can depend on

707Ex. Users Manual. ma Calibrator

MIT515, MIT525, MIT1025, MIT1525

Users Manual. Phase Rotation Indicator

Dawson DDM190D. Digital Multimeter User s Manual

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

RISH Insu 10 Analog-Digital Insulation Tester

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

USER MANUAL. Insulation Tester + DMM. Model MG320

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Model UT601: OPERATING MANUAL

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA KEWTECH

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Table of Contents Title Page No.

SPECIFICATION FOR APPROVAL CHARGER JBC036-11

WENS30C Loop Calibrator

HEAVY DUTY POWER RELAYS FEATURES

MIT300 Series Insulation and Continuity testers USER MANUAL

Specification Approval Sheet

Switching DC Power Supply

OPERATING INSTRUCTION

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

Transcription:

Content Attention... 2 I. Brief introduction... 4 II. Electrical Symbol... 4 III. Technical Specification... 4 IV. Instrument Structure... 6 V. Instrument Operation... 6 1. boot up, shutdown... 6 2. Manual / automatic switch... 6 3. Switch the gear of rated operating current... 7 4. Reset... 7 5. Measurement... 7 VI. Replacing Battery... 9 VII. Accessories... 9 1

Attention Thank you for purchasing ETCR8600 Leakage Protector Tester of our company. In order to make better use of the product, please be certain: To read this user manual carefully. To comply with the operating cautions presented in this manual. u Pay special attention to safety when using this instrument in any case. u Observe the text and symbols attached to the front and rear panels of the instrument. u Don not use the instrument to measure a line with a voltage higher than 250V. u Before measurement, disconnect the load fuse of the measured leakage protector. u L interface must connect to the fire wire, N interface must connect to the ground wire. u The Socket test line of the instrument is custom-made, forbid to use other plug with cord instead of it. u After measurement, removed the test wire from the measured wire first. u It is forbidden to use the instrument when neither rear cover of the instrument nor the batter cover is in place. u Never use the instrument when the instrument case or measuring wire is broken and therefore any metallic part is exposed. u Don not place the instrument at a environment with high temperature, high humidity, condensation and direct sunshine for a long time u It is necessary to maintain the instrument periodically to keep it clean. Don not wipe the instrument by using corrosive medium or abrasive object. u Please observe the correct polarity when replacing the battery. Remove the battery from the instrument if you expect not to use the instrument for a long time. u Please replace the battery with a new one when the batter voltage is so low that the LCD display is dim. 2

u Operation, disassembly and maintenance of the instrument must be carried out only by a authorized and qualified person. u When there is an instrument fault, never use it because continual use may result in danger. In this case, isolate the instrument immediately and delivered to an authorized agency for dealing with it. u The user must follow the safety instructions preceded by warning symbol on the instrument and manual. u The user must strictly follow the instructions preceded by danger symbol on the instrument and manual. 3

I. Brief introduction ETCR8600 Leakage Protector Tester is well designed and manufactured for online measuring the leakage operating current, leakage non-operating current, leakage operating time of the leakage protector; adopt 128dots 64dots displayed, it is convenient and intuitive. The range of leakage current is 0~500mA(10 gears: 15, 30, 50, 75, 100, 150, 200, 250, 300, 500mA),range of the leakage operating time is 0~999ms. It is a product with high accuracy, small size, light weight, exquisite appearance, easy to carry, is an ideal tool for variety of leakage protector in site or in laboratory testing. II. Electrical Symbol Extremely dangerous! The operators must keep to the safety rules strictly, otherwise, electric shock will result in death or injury. Dangerous! The operators must keep to the safety rules strictly, otherwise, electric shock will result in will result in death or injury. Warning! The operators must keep to the safety rules strictly, otherwise, personal injury or equipment damage will occur. Double insulation. Alternating current (AC). Direct current (DC). III. Technical Specification Function Power Supply Measurement of leakage operating current, leakage non-operating current, leakage operating time of the leakage protector. DC6V alkaline batteries (LR6 1.5V 4). Test line Voltage Do not exceed AC 250V. rated voltage AC 220V. 4

Leakage current gear range of the leakage operating time accuracy of the leakage operating time accuracy of the current for each gear Failure informatio n length of the test line Test mode Display Mode Dimension Weight LCD Dimension battery voltage Working Current Working Humiture Storage Humiture Insulating Strength Applicable 15, 30, 50, 75, 100, 150, 200, 250, 300, 500mA. 0~999ms. ±0.5%. ±1.0%. When the LCD display fault, it may be the measured rated operating current gear is too small or the leakage protector has some faults. 1.8m. Manually or automatically. LCD: 128dots 64dots. 170mm 75mm 30mm. 290g (including the batteries); Total weight: 350g(including the packing). Display field: 44mm 27mm. A Low-Battery symbol is displayed and the user should replace the battery with a new one when the battery voltage drops to 4.8V. In this case, the measured values are still accurate. 40mA Max. -10-40, below 80%rh. -10-60, below 70%rh. 100MΩ, AC2kV/rms(between the alloy of the clamp and the housing). IEC1010-1, IEC1010-2-032, Pollution degree 5

safety rules 2, CAT III(600V) IEC61326(EMC standard). IV. Instrument Structure 1. N interface (connect ground wire) 2. L interface (connect fire wire) 3. LCD 4. AT: auto key 5. RANGE+ key (gear up) 6. MT: manual key 7. RANGE- key(gear down) 8. RESET: reset key 9. POWER: (boot up, shutdown) 10. Crocodile clip test line 11. Probe test line 12. Socket test line V. Instrument Operation 1. boot up, shutdown Boot up the instrument by pressing the POWER key. The LCD will light up. If the LCD display is dim, the battery voltage may be low. If so, replace the battery with a new one. Press the POWER key again to shutdown the instrument. This instrument will be shutdown automatically after starting 5 minutes. 2. Manual / automatic switch This instrument has the manual (MT) and (AT) automatic test mode. Press MT and AT key to switch to manual or automatic mode. After boot up, it is default to the manual(mt) test mode. In the manual mode, the top left corner of the LCD shows MT symbol, in the automatic mode, the top left corner of the LCD shows MT symbol. In the automatic mode, start the measurement from the lowest gear 15mA rated operating current. If the leakage protector does not trip, the instrument will increase a gear automatically after 2 seconds. If the leakage protector also does not trip, the instrument 6

will increase a gear automatically again after 2 seconds, until the trip breaking. At this time, the displayed gear on the button of LCD screen is the actual leakage operating current value, the displayed time is the leakage operating time. 3. Switch the gear of rated operating current The rated operating current of the instrument from 0 to 500mA were divided into ten gears: 15mA, 30mA, 50mA, 75mA, 100mA, 150mA, 200mA, 250mA, 300mA, 500mA. Press RANGE- or RANGE+ to switch the gears. On the bottom of the LCD indicates the current gear. After boot up, it is default to the lowest gear (15mA) to start test. 4. Reset After each test, press the RESET key to reset, the leakage operating time will be zero clearing, then can be tested again. 5. Measurement Electric shock, dangerous! The instrument can be operated only by the trained and authorized person. The operators must keep to the safety rules strictly, otherwise, electric shock will result in personal injury or damage to the equipment. Don not use the instrument to measure the lines with a voltage of higher than 250V. Otherwise, electric shock will result in personal injury or damage to the equipment. L interface must connect to the fire wire of the measured leakage protector, N interface must connect to the ground wire of the measured leakage protector. Otherwise, electric shock will result in damage to the equipment. The Socket test line of the instrument is custom-made, the red plug connect to the fire wire, the black plug connect to the ground wire. Forbid to use other plug with cord instead of it. Otherwise, electric shock will result in personal injury or damage to the equipment. 7

Before measurement, disconnect the load fuse of the measured leakage protector to avoid damage to the load equipment. Then check the nameplate rating of the measured leakage protector, According to the nameplate rating to determine the current gear.(generally, for the indoor type single phase two-wire mode leakage protector, the rated operating current is 30mA, the rated non-operating current is 15mA, The break duration 0.1s, that is 100ms). Boot up, select the test mode and the gear of the rated leakage operating current, it is default to the manual (MT) test mode, The connection as shown below: Connection 1: one end of black crocodile clip test line insert to the black N interface of the instrument, the other end (crocodile clip) clip to the grounding pile of the leakage protector; one end of red probe test line insert to the red L interface of the instrument, the other end (probe) touch the fire wire of the leakage protector s output end to measurement. Connection 2: the black plug of the dedicated socket test line insert into the N interface of the instrument, the red plug insert into the L interface of the instrument, the three-pin plug insert into or touch the socket to measurement. At this time, if the performance of the leakage protector is normal, it will trip breaking, the breaking time displayed in the LCD screen, such as 075ms. If the leakage protector does not trip, fault failure information will display in the LCD, it may be the measured rated operating current gear is too small or the leakage protector has some faults. Press the RESET key to reset, then can be tested again. 8

VI. Replacing Battery To avoid electric shock, when replacing the batteries, the test line must be pulled away from the instrument, and do not connect with the measured wire. Observe the correct battery polarity, otherwise, the instrument will be damaged. Replace the battery with a new one as soon as possible when the battery voltage is low. Do not mix the old and new battery together. 1. When the battery voltage drops to 4.8V, a symbol will be displayed on the instrument, indicating the battery voltage is low. Replace the battery immediately. 2. Press the POWER key to shutdown the instrument. After confirming that the instrument has been shutdown f, open the battery cover and replace with a new battery recommended by the manufacturer. Pay special attention to the correct battery polarity. Replace the battery cover, boot up the instrument and confirm that the instrument can operate properly. (as shown in the following figures). VII. Accessories Tester Shoulder bag Probe test line 1 PCS 1 PCS 1 PCS 9

Crocodile clip test line Socket test line Packing box Alkaline dry battery (AAA 1.5V) User manual,warranty card,quality certificate 1 PCS 1 PCS 1 PCS 4 PCS 1 Copy 10

Manufactured by ETCR Electronic Technology Company Address: F-3F, No.4 Pengshang Zhifu Road, Jiahe, Baiyun District, Guangzhou, Guangdong, China Post Code: 510440 Tel: (86-20)62199556 Fax: (86-20)62199550 E-mail: info@etcr.cc Website: www.etcr.cc