MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Similar documents
MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

Cable current transformers for indoor applications. Product overview. Cable current transformers. for indoor applications.

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

Surge arrester POLIM-H..SD

Mini contactors B6, BC6 with 3 pole

Electronic overload relays EF205 and EF370

Electronic overload relay EF65, EF96 and EF146

Current accuracy class. Sensor principles

EMPAC Metal enclosed capacitor bank for wind applications

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

ZX-Family Gas-insulated medium voltage switchgear

Surge arrester POLIM-C.. HD

Surge arrester POLIM-H.. ND

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Voltage limiting device HVL

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Thermal overload relay TF65 and TF96

Voltage limiting device HVL

Thermal overload relay TF140DU and TF140DU-V1000

ZX2 Gas-insulated medium voltage switchgear

RSD100 (Contrac) Electrical Linear Actuator

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Selective main circuit breakers S 750 series Technical Data

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Medium Voltage Products. KEVA 24 B20; KEVA 24 B21 Voltage Sensors Instructions for installation, use and maintenance

LV Capacitors QCap-L series Capacitors for power factor correction

Thermal Overload Relays

Medium voltage products. KEVCD A combined current and voltage sensor Instructions for installation, use and maintenance

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

EAS822 (Contrac) Power Electronic Unit

Manual motor starters Overview and benefits

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

Surge arrester POLIM-H..N

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

Shut-off valves and accessories for pressure measuring instruments

Manual motor starter MS116

Manual motor starter MS132

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

KEVA 24 Cxx(c) Indoor voltage sensors for NEXANS Instructions for installation, use and maintenance

Manual motor starter magnetic only MO325

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Manual motor starter MS116

ABB central inverters PVS to 2091 kva

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starter MS132

Current sensor. Instructions for installation, use and maintenance. Type KECR 17,5 AC1 ABB

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

ABB cable glands SCG series Stainless Steel 316L, general purpose cable glands

Manual motor starter MS132

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

CATALOGUE TYP QDS. 7,2-25 kv

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

ABB i-bus KNX DG/S x DALI-Gateway Basic

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

ZX-Family Gas-insulated medium voltage switchgear

Low voltage bushings for pad-mounted distribution transformers Technical information guide

Low Voltage Systems MNS and MNS is PowerCenter

Product information. ECOSS Electronic compact starter for wound rotor drives

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Moving Coil Indicators with direct temperature sensor input

Breaker-failure protection RAICA

Inductive voltage transformers

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

MB3600-CH30 Laboratory FT-NIR analyzer for biodiesel applications Suitable for production optimization and product quality assessment

TriLine PowerModules Overview with Planing Examples

US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

CP Automatic capacitor bank

Short form catalogue Motor protection and control Manual motor starters

Instruction manual. EK6 Earthing switch 36/40.5 kv

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Traction systems for Light Rail Vehicles Selected references

SR1 multipurpose enclosures Enclosures for automation and distribution applications

TwinLine The new system of wall-mounting and floor-standing cabinets

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

Transcription:

MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers

2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage Values 3.6-12 kv 10-42 kv 40-75 kv Max. rated burden, classes 25/0.2-75/0.5-150/1 VA/cl Residual winding 50-200/6P VA/cl Description The TJC 4 single-pole insulated voltage transformers are cast in epoxy resin and designed mostly for insulation voltages of 3.6 kv to 12 kv. If no other value is required the transformers are manufactured with a overvoltage factor of 1.9 x Un/8 hrs. One outlet of the primary winding, including the respective terminal is insulated from the earth to a level which corresponds to the rated insulation value. The transformer is mostly equipped with two secondary windings, the first one for either measuring or protection purposes, the other for being connected into an open-delta connection in a threephase system. One terminal of each secondary winding and one of the open-delta connected terminals have to be earthed during the transformer operation. When not required otherwise, the secondary windings are lead out into a casttype secondary terminal board. The transformer can be mounted in any position. The transformers are fixed by four screws, the M8 bolted earthing clamp is located on the transformer base plate. The secondary terminal board is covered with a transparent and sealable cover made of plastic material. Rated primary voltages 3/ 3 kv; 3.3/ 3 kv; 6/ 3 kv; 6.6/ 3 kv; 10/ 3 kv; 11/ 3 kv. Other primary voltages can also be supplied on request. Rated secondary voltages 100/ 3 V; 110/ 3 V accuracy classes 0.2; 0.5; 1 (measuring winding) or 3P; 6P (protection winding). Other secondary voltages can also be supplied on request. Rated voltages for open-delta connection 100/3 V; 110/3 V - class 6P. Other voltages for open-delta connection can also be supplied based on customer requirement. Rated frequency 50 Hz; 60 Hz. Based on a discussion with the manufacturer the transformer can also be designed for two primary voltage levels (with change over secondary side). The transformers are manufactured conformably to the requirements and recommendations of the following standards and regulations: IEC, VDE, IEEE, BS, GOST and CSN. For marking of the voltage transformer outlets see picture 01 a-e Optional accessory The TJC 4 can be delivered together with an external fuse holder as an option in case of interest. The fuse holder is equipped with JT6 fuse with tripping current 300 ma (recommended for system voltage above 6,6 kv) or 600 ma (recommended for system voltage up to 6,6 kv). It is delivered separately, not mounted to TJC 4, but together with all mounting accessories for easy installation. Fuse holder with fuse can be delivered fully separately as well.

3 01 Marking of the voltage transformers outlets a Single-pole insulated transformer b Single-pole insulated transformer with a tap c Single-pole insulated transformer with two secondary windings d Single-pole insulated transformer with two secondary windings, with one of which being the auxiliary (residual) winding e Single-pole insulated transformer with two secondary, tapped windings, with one which being the auxiliary (residual) winding a c d e b 01 Standard execution of the transformers Primary voltage, [V] Secondary voltage Residual winding voltage, [V] accuracy burden, [VA] voltage, [V] accuracy burden, [VA] 3 000/ 3 100/ 3 0.2 10;15;25 3 000/ 3 100/ 3 0.2 10;15;25 100/3 6P 50 3 000/ 3 100/ 3 0.2 10;15;25 100/3 6P 100 3 000/ 3 100/ 3 0.5 15;25;50 3 000/ 3 100/ 3 0.5 15;25;50 100/3 6P 50 3 000/ 3 100/ 3 0.5 15;25;50 100/3 6P 100 3 000/ 3 100/ 3 1 50;75;100 3 000/ 3 100/ 3 1 50;75;100 100/3 6P 50 3 000/ 3 100/ 3 1 50;75;100 100/3 6P 100 3 300/ 3 110/ 3 0.2 10;15;25 3 300/ 3 110/ 3 0.2 10;15;25 110/3 6P 50 3 300/ 3 110/ 3 0.2 10;15;25 110/3 6P 100 3 300/ 3 110/ 3 0.5 15;25;50 3 300/ 3 110/ 3 0.5 15;25;50 110/3 6P 50 3 300/ 3 110/ 3 0.5 15;25;50 110/3 6P 100 3 300/ 3 110/ 3 1 50;75;100 3 300/ 3 110/ 3 1 50;75;100 110/3 6P 50 3 300/ 3 110/ 3 1 50;75;100 110/3 6P 100 6 000/ 3 100/ 3 0.2 10;15;25 6 000/ 3 100/ 3 0.2 10;15;25 100/3 6P 50 6 000/ 3 100/ 3 0.2 10;15;25 100/3 6P 100 6 000/ 3 100/ 3 0.5 15;25;50 6 000/ 3 100/ 3 0.5 15;25;50 100/3 6P 50 6 000/ 3 100/ 3 0.5 15;25;50 100/3 6P 100 6 000/ 3 100/ 3 1 50;75;100 6 000/ 3 100/ 3 1 50;75;100 100/3 6P 50 6 000/ 3 100/ 3 1 50;75;100 100/3 6P 100 6 600/ 3 110/ 3 0.2 10;15;25 6 600/ 3 110/ 3 0.2 10;15;25 110/3 6P 50 6 600/ 3 110/ 3 0.2 10;15;25 110/3 6P 100 6 600/ 3 110/ 3 0.5 15;25;50 6 600/ 3 110/ 3 0.5 15;25;50 110/3 6P 50

4 TJC 4 INDOOR VOLTAGE TRANSFORMERS Primary voltage, [V] Secondary voltage Residual winding voltage, [V] accuracy burden, [VA] voltage, [V] accuracy burden, [VA] 6 600/ 3 110/ 3 0.5 15;25;50 110/3 6P 100 6 600/ 3 110/ 3 1 50;75;100 6 600/ 3 110/ 3 1 50;75;100 110/3 6P 50 6 600/ 3 110/ 3 1 50;75;100 110/3 6P 100 10 000/ 3 100/ 3 0.2 10;15;25 10 000/ 3 100/ 3 0.2 10;15;25 100/3 6P 50 10 000/ 3 100/ 3 0.2 10;15;25 100/3 6P 100 10 000/ 3 110/ 3 0.2 10;15;25 10 000/ 3 110/ 3 0.2 10;15;25 110/3 6P 50 10 000/ 3 110/ 3 0.2 10;15;25 110/3 6P 100 10 000/ 3 100/ 3 0.5 15;25;50 10 000/ 3 100/ 3 0.5 15;25;50 100/3 6P 50 10 000/ 3 100/ 3 0.5 15;25;50 100/3 6P 100 10 000/ 3 110/ 3 0.5 15;25;50 10 000/ 3 110/ 3 0.5 15;25;50 110/3 6P 50 10 000/ 3 110/ 3 0.5 15;25;50 110/3 6P 100 10 000/ 3 100/ 3 1 50;75;100 10 000/ 3 100/ 3 1 50;75;100 100/3 6P 50 10 000/ 3 100/ 3 1 50;75;100 100/3 6P 100 10 000/ 3 110/ 3 1 50;75;100 10 000/ 3 110/ 3 1 50;75;100 110/3 6P 50 10 000/ 3 110/ 3 1 50;75;100 110/3 6P 100 11 000/ 3 100/ 3 0.2 10;15;25 11 000/ 3 100/ 3 0.2 10;15;25 100/3 6P 50 11 000/ 3 100/ 3 0.2 10;15;25 100/3 6P 100 11 000/ 3 110/ 3 0.2 10;15;25 11 000/ 3 110/ 3 0.2 10;15;25 110/3 6P 50 11 000/ 3 110/ 3 0.2 10;15;25 110/3 6P 100 11 000/ 3 100/ 3 0.5 15;25;50 11 000/ 3 100/ 3 0.5 15;25;50 100/3 6P 50 11 000/ 3 100/ 3 0.5 15;25;50 100/3 6P 100 11 000/ 3 110/ 3 0.5 15;25;50 11 000/ 3 110/ 3 0.5 15;25;50 110/3 6P 50 11 000/ 3 110/ 3 0.5 15;25;50 110/3 6P 100 11 000/ 3 100/ 3 1 50;75;100 11 000/ 3 100/ 3 1 50;75;100 100/3 6P 50 11 000/ 3 100/ 3 1 50;75;100 100/3 6P 100 11 000/ 3 110/ 3 1 50;75;100 11 000/ 3 110/ 3 1 50;75;100 110/3 6P 50 11 000/ 3 110/ 3 1 50;75;100 110/3 6P 100

5 Dimensional Drawings TJC 5 TJCH 4 TJCH 5 TJC 4 Weight: appr. 20 kg Creepage Distance: 280 mm 266 M10x15 38 28 20 209 220 Pg16 14 M8 27 11 10 140 338 270 130 125 4 148 11 107 11 Drawing n. 44203570

6 TJC 4 INDOOR VOLTAGE TRANSFORMERS EXTERNAL FUSE COVER 17,5kV External fuse holder M8 49 346 35 4 10 175 13 fuse JT6 300 ma 75 1VL4200499R0101 fuse JT6 300, 600mA fuse JT6 600 ma 1VL4200499R0102

CONTACT US ABB s.r.o. EPDS Brno Videnska 117, 619 00 Brno, Czech Republic Tel.: +420 547 152 021 +420 547 152 854 Fax: +420 547 152 626 E-mail: kontakt@cz.abb.com www.abb.com NOTE We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB. Copyright 2018 ABB All rights reserved 1VLC000520 Rev.5, en 2018.05.25