atalog Number ystem For illustrative purposes only. ircuit reaker election uide T QL 5 E Identification Interrupting Rating Type oles Voltage mpere Rating Insert for pecials = 0kI QL = lug-in = 20/240Vac F = pole = 22kI Q = 2 lug-in 2 = 240V FI = 65kI Q = olt-on Omit for TQ F = 2-pole breakers FI (all 20/240Vac) F = FI Recommendations based on standard conditions. Installation must conform to all local and national codes. pplication election Recommended ircuit reaker ppliance verage atts Volts mps ire ize 2-inch -inch ir onditioner Up to,000 TU 200 20 20 2#2 TQ20 TQL20 Up to 23,000 TU 2400 240 20 3#2 TQ220 TQL220 Up to 30,000 TU 7200 240 30 3#0 TQ230 TQL230 ttic Fan Up to 2 20 5 2#4 TQ5 TQL5 Up to 20 20 2#2 TQ20 TQL20 athroom or Outdoor Receptacles 400 20 5 2#4 TQL5F 900 20 20 2#2 TQL20F edroom Receptacles (for maximum 400 20 5 2#4 TQL5F safety; required by 2002 NE) 900 20 20 2#2 TQL20F ranch ircuits (Indoor Receptacles) 400 20 5 2#4 TQ5 TQL5 900 20 20 2#2 TQ20 TQL20 lothes ryer 5000 240 30 3#0 TQ230 TQL230 ishwasher 800 20 20 2#2 TQ20 TQL20 oorbell Transformer 500 20 5 2#4 TQ5 TQL5 Electric eater 650 20 20 2#2 TQ20 TQL20 Electric Range 0000 240 50 3#6 TQ250 TQL250 Electric elder (240V; over 0 away) 240 50 3#6 TQ250 TQL250 Fixed Lighting 200 20 5 2#4 TQ5 TQL5 arbage isposal 300 20 20 2#4 TQ20 TQL20 ot Tub or pa 240 40 2#8 TQL240F 240 50 2#8 TQL250F ot ater eater 4500 240 30 2#0 TQ230 TQL230 Motors (ingle hase) Up to 2 20 5 2#4 TQ5 TQL5 2 to 20 20 2#2 TQ20 TQL20 to 2 240 5 2#4 TQ25 TQL25 2 to 3 240 30 2#0 TQ230 TQL230 Refrigerator or Freezer 350 20 5 2#4 TQ5 TQL5 ump ump Up to 2 20 5 2#4 TQ5 TQL5 2 to 20 20 2#2 TQ20 TQL20 [ RELIILITY N EONOMY. ] Q Line ircuit reakers 5 ashing Machine 200 20 5 2#4 TQ5 TQL5 ell ump Up to 2 20 20 2#2 TQ20 TQL20 240 5 2#4 TQ25 TQL25 2 to 20 30 2#0 TQ30 TQL30 240 20 2#2 TQ220 TQL220 240 20 2#8 TQ240 TQL240 pecial afety ircuit rotection roducts Included among E s circuit protection products are several that add the extra measure of safety that is increasingly important to today s new home buyers and remodelers. ee page 8 for details. afety Need afety olution mp Rating round fault protection for circuits supplying power to outdoor, bathroom, kitchen, garage and spa area receptacles. FIs (ground fault circuit interrupters) 5-50 Maximum protection against fires through detection and interruption of arcing caused by damaged wire insulation or extension cords. The 2002 NE FIs (arc fault will require this protection in bedroom circuits. circuit interrupters) 5-20 hole house protection of sensitive electronic equipment computers, fax machines, televisions, stereos, VRs from electrical surges. urge arrester N
I E R Q U L I T Y. L O E R I N T L L E O T. I E R Q U L I T Y. L O E R I N T L L E O T [ IER QULITY. LOER INTLLE OT.] owermark old Load enters 0 ackaging features comprehensive selection and application data. Fronts are packed in inner cartons for added protection during shipment and at the job site. complete family of meter socket load centers ring style and ringless, wide and narrow, meter mains, farm panels and more deliver specialized solutions for special situations. Main lug load centers offer an economical solution for subpanels and similar applications. ll main lug units 25 and above convert easily to main breaker. E s residential load centers reach into commercial applications as well, with riser panels, auxiliary gutters, three-phase units with standard 22kI ratings, and all the accessories needed to complete the job. ll owermark old load centers are designed and built for faster installation and more dependable performance. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 00% neutral terminations. turdy copper bus and galvanized box increase durability and reliability. ombination slotted/robertson screws speed wiring. ll holes are rated for 4-4 wire. 00% rated split neutral on each side. Load centers accept Q Line circuit breakers, including E s exclusive 2 TQs. The owermark old line includes a wide range of outdoor as well as indoor units. ccessories & Options oor lock & handle Equipment ground kits ub-feed & feedthru lugs Front filler plates andle lock & ties ardware kits Main breaker retainers Neutral kits Universal raintight hubs
atalog Number ystem For illustrative purposes only. Load enter election uide Main reaker Load enters Max. ranch Maximum paces Main mp reaker Rating (mps) Rating TQL 2 TQ Total -pole ase u l -pole 2-pole -pole 2-pole paces at. No. at. No. uffix 2 uffix 23 60 60 60 4 2 8 4 8 TM860 F, UEN 2 6 24 0 24 TM20,R U 00 00 00 20 0 20 TM200,R U 32 6 32 TM320 U 24 2 24 TM242,R U 25 25 25 2 6 24 0 24 TM22,R U 6 8 6 6 24 TM62 U 8 4 6 6 6 TM85 R UFL 50 50 50 24 2 20 6 30 TM245,R U 32 6 32 TM325,R U 6 8 32 4 32 TM65,R U 8 4 6 6 6 TM820 R UFL 6 8 32 6 32 TM620 U 200 200 75 20 0 40 20 40 TM2020,R U 32 6 6 6 40 TM3220,R U 40 20 40 TM4020,R U onvertible Load enters Max. ranch Main mp reaker Rating (mps) Maximum paces at. No. Rating TQL 2 TQ Total -pole ase u l -pole 2-pole -pole 2-pole paces at. No. uffix 2 uffix 23 00 70 55 6 3 2 4 2 TLM62,F U, 8 4 6 6 6 TLM82,F U, 24 2 24 TLM242,R U 25 25 25 2 6 24 0 24 TLM22,R U 6 8 2 6 24 TLM62 U 50 50 50 20 0 20 TLM205 U 24 2 2 6 30 TLM245,R U 6 8 32 4 32 TLM620,R U 200 200 75 20 0 40 8 40 TLM2020,R U 32 6 6 6 40 TLM3220 U 40 20 40 TLM4020,R U Main Lug Load enters Max. ranch Main mp reaker Rating (mps) Maximum paces at. No. Rating TQL 2 TQ Total -pole ase u l -pole 2-pole -pole 2-pole paces at. No. uffix 2 uffix 23 40 40 40 2 4 4 TL240,R U 70 70 60 2 4 4 TL270,R U 25 70 55 T M 42 4 20 U E Identification Type Maximum Number Insert for 3-phase, us mpere Rating Enclosure Type Insert for Insert for pecials of paces 4-wire Load enters owermark old M = Main reaker 4-42 0 = 00 = ombination Flush U = opper us or T = Factory Installed L = Main Lug 2 = 25 and urface, Indoor round ar LM = onvertible 5 = 50 F = Flush = ottom Feed Main reaker L = Main Lug, 20 = 200 = urface FL = Factory installed Thermoplastic 22 = 225 R = Outdoor Feed-thru Lugs Enclosure 40 = 40 = Optional door for 6-8 60 = 60 circuit indoor panels. (oors 70 = 70 are standard on all other units.) (For details on these and other load centers, see the selection tables on the following pages.) 4 2 8 3 8 TL42,R 4 2 8 3 8 TL42, R [ IER QULITY. LOER INTLLE OT. ] owermark old Load enters atalog number is constructed by adding uffix and uffix 2 to ase atalog Number. 2 F = Flush mount indoor = urface mount = ombination flush/surface mount indoor R, R = Outdoor 3 U = opper bus UFL = opper bus, feed-thru lugs UEN = opper bus, generator panel with dual main circuit breakers = Optional door for 6- and 8-circuit indoor panels (door standard on outdoor panels)
E L E T I O N T L E. E L E T I O N T L E. E L E T I O N T L E. E L E T I O N T L E. [ ELETION TLE. ] owermark old & lus Load enters UL Listed (anelboards No. 67) 60 /75 onductor Rating Indoor Fronts ombination urface/flush uitable for Use as ervice Entrance Equipment hen Installed in ccordance with the National Electrical ode 22kI RM ymmetrical, Except here Noted Main Lug & onvertible Load enters ingle-phase, Three-wire, 20/240 Volts ac, Top Feed Factory Installed Main Lugs (TLM units convertible to main breaker) owermark lus catalog numbers shown in italics 2 Equipment Maximum paces Indoor Type Enclosure23 Outdoor Type 3R Enclosure3 Main Main ire ize round it mpere TQL Total ox No. ox No. / kcmil Order eparately 2 TQ Rating -pole at. No. ee at. No. ee u-l ee age 6 p 2p p 2p paces age 24 age 25 at. No. 40 2 4 4 TL240U4 TL240RU R 4-4 T4 70 2 4 4 TL270U4 TL270RU R 6-3 T4 4 2 8 3 8 TL42➄ 2 TL42R➅ R TL 4 2 8 3 8 TL42T➄8 2 TL42RT➅ R TL Installed 4 2 8 3 8 TL42R2➅ R -2/0 TL 4 2 8 3 8 TL42➄7 2 TL42R➅7 R TL 4 2 8 3 8 TL42T➄ 2 TL42RT➅8 R TL Installed 25 6 3 2 6 2 TLM62FU, U0 3, 3 TLM62RU0 R2 T2 6-3 8 4 6 8 6 TLM82FU, U90 3, 3 TLM82RU0 R2 T2 2 6 24 0 24 TLM22U 4 TLM22RU R3 TL2 2 6 24 0 24 TLM22U 4 T24 Installed 6-2/0 6 8 6 6 24 TLM62U 4 T2 or T24 24 2 24 TLM242U 7 TLM242RU R4 T2 or T24 50 20 0 20 8 30 TLM205U 8 T32-3/0 (u) 2-3/0 (l) 24 2 2 4 30 TLM245U 9 TLM245RU R6 T24 or T32 2 6 24 0 24 TLM220RU R5 T24 6 8 32 4 32 TLM620U 8 TLM620RU R5 T32 6 8 32 6 32 TLM620U 8 T32 Installed 200 20 0 40 8 40 TLM2020U 9 TLM2020RU R6-250 (u) 2/0-250 (l) T24 or T42 20 0 40 8 40 TLM2020U 9 T42 Installed 32 6 6 6 40 TLM3220U 2 T32 40 20 40 TLM4020U 3 TLM4020RU R8 T42 225 42 20 42 TLM4222U 4 TLM4222RU R8-300 (u) 2/0-300 (l) T42 400 24 20 24 TL2440F, 6 TL2440R R9 (2) TL2 (2) 2/0-250 42 20 42 TL4240F, 2 6 TL4240R 2 R9 (2) TL2 600 42 20 42 TL4260F, 2 7 TL4260R 2 R9 (2) 250-350 (u) (2) 350-500 (l) (2) TL2 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down. For bottom feed door handle, see page 7. 2 40-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately (see page 7). 3 TL load center enclosures are thermoplastic; TL and TLM load center enclosures are galvanized steel. 4 No door. ➄ No door, 0kI. 6 0 ki. 7 Maximum branch or main circuit breaker rating: 90 amp with u, 70 amp with l. 8 25 amp maximum branch capacity. 9 FU indicates flush mount enclosure; U indicates surface mount enclosure. dd to catalog number for optional door (example: TLM62U). 0 For main breaker, order TQLR2 retainer kit plus 2-pole circuit breaker. ee page 7. For main breaker, order TQM000. lso order 2-pole TQL, TQL or TQL circuit breaker. ee page 6. 2 Not suitable for use as service entrance equipment.
IMENION N NOOUT. IMENION N NOOUT. IMENION N NOOUT. [ IMENION N NOOUT. ] owermark old & lus Load enters Indoor Enclosures imensions (in inches) ox No. idth eight epth 5 6 0 3 8 2 7 2 9 7 32 3 5 6 2 7 4 9 3 3 9 6 3 8 3 3 8 3 2 5 8 2 3 8 3 3 8 4 4 9 3 3 4 4 4 9 3 3 4 6 4 23 3 3 4 7 4 24 6 3 3 4 8 4 26 7 6 3 3 4 9 4 28 7 6 3 3 4 9 4 28 7 6 3 3 4 0 4 30 7 6 3 3 4 4 33 3 6 3 3 4 2 4 35 7 6 3 3 4 3 4 39 3 6 3 3 4 4 4 43 7 6 3 3 4 5 4 43 7 6 4 5 8 6 6 45 8 5 3 6 7 20 59 7 8 6 3 32 nockouts ymbol E F L M N Q R T U V Y Z 9 6 3 8 3 8 3 8 2 2 2 2 2 2 2 2 3 4 3 4 3 4 3 4 3 4 onduit ize 4 4 4 4 4 4 4 4 4 4 4 in 2 2 2 2 2 2 2 2 2 2 Inches 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 2 3 2 3 2 4 ox ox2 24 Q Y M Y M Y ox2 ox3, 3 ox4, 6, 7, 8, 9, 0,, 2, 3, 4 F Q Y ox4, 9 Z Z N N ox5 T T ox6 U V R ox7