Expand your vibration program to new heights.

Similar documents
Tissue Machine Bearing Failure and PeakVue Problem Resolution

Improving predictive maintenance with oil condition monitoring.

Automotive manufacturing accelerometer applications

Automotive manufacturing accelerometer applications

Rosemount Orifice Series Differential Pressure Flow

Vibration Diagnostic Software. Proven Automated Diagnostic Technology for Machinery Condition Assessment

AMS ValveLink SNAP-ON Applications

AERO AERODERIVATIVE AND INDUSTRIAL GAS TURBINES NON INTRUSIVE SENSOR SYSTEM

ValveLink SNAP-ON Application

Understanding the benefits of using a digital valve controller. Mark Buzzell Business Manager, Metso Flow Control

A New Practical and Reliable Approach to the Vibration Monitoring of Cooling Tower Fans

Rosemount 228. Toroidal Conductivity Sensor. Product Data Sheet July Series LIQ-PDS-228

WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery

WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery

Artesis MCM Case Studies. March 2011

Rosemount 2160 Wireless Vibrating Fork Liquid Level Switch

FlowScanner 6000 SGIM-1 and SGIM-2 Strain Gauge Interfaces

Bettis TEC2 Electric Actuator with Model 500 Quick-Start Guide. Quick-Start Guide E2K Rev. 2 October 2017

ALERT Analysis Systems

Fisher TBX Steam Conditioning Valve

Top Mount Installation for DP Flowmeters in Steam Service

Laird Thermal Systems Application Note. Cooling Solutions for Automotive Technologies

Vibration Monitoring of Electric Rope Shovels

Effect Of Bearing Faults On Dynamic Behavior And Electric Power Consumption Of Pumps

CHAIN WEAR ANALYSIS WITH LUBECON

Innovation in actuation.

True Fail-Safe Technology and Precision Control for Reliable Shutdown

Eddy Current Displacement Transducer Specifications

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

Disassembly and Reassembly for WG Series Worm Gear Operator. User Instructions Part Number: XXXXXX, Rev. 0 Release: February 2017

Based on the findings, a preventive maintenance strategy can be prepared for the equipment in order to increase reliability and reduce costs.

Advanced Maintenance Technologies

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures

CBA-Series Pneumatic Dimension Data Metric

Truly Wireless Sensing Enabling a paradigm shift in process monitoring

Flow Measurement Services for the Oil & Gas, Power, Chemical and Processing Industries

DAMAGE IDENTIFICATION AND VIBRATION ANALYSIS TECHNIQUE FOR GEAR BOX

Bettis GH-Series Pneumatic Spring-Return Actuator Torque Chart Imperial

TX5634 to TX5639 Data Sheet

Shops Enter Repair and Failure Information for Plants

Operating Instructions M3 and M3HW Jackscrew Manual Override. Service Instructions Rev. D October 2014

DRAFT. Installation, Operation and Maintenance Instructions for Emerson KBG-V Series

Eddy Current Displacement Transducer Specifications

Motor Current Signature Analysis And Its Applications In

RecipCOM by HOERBIGER More protection and efficiency for reciprocating compressors

Measurement Types in Machinery Monitoring

Wind Energy Solutions

Application Engineering Europe

EIM TEC2 Electric Actuator with Model 500 Quick-Start Guide

Detection of Fault in Gear Box System using Vibration Analysis Method

Protecting your actuation process without compromise in severe applications

Installation, Operation, and Maintenance Instructions for Bettis RGS F-Series Spring-Return (SR) Actuators

Bettis Nuclear Series Actuators. Operation and Maintenance Manual VA Rev. E June 2014

Bettis GC01-Extension Series Extension Pneumatic Double-Acting & Spring-Return Actuator Torque Chart Metric

Rosemount 285 Annubar Primary Element Series

CBA300 Series Pneumatic Actuators Improved Design - Compact, Lightweight To Suit All Applications And Environment

IRRIGATION Maintenance In the south east

Hydraulic Maintenance & Troubleshooting. Content - Norman Kronowitz Presenter Jim Trinkle

Bettis G01-Extension Series Extension Pneumatic Double-Acting & Spring-Return Actuator Torque Chart Imperial

WARNING. Mounting Instructions D103996X012 May DVC6200/DVC2000 Digital Valve Controller on Linear Actuator

AV-25 Rotating Equipment Health Machine Condition Monitoring-MCM

Triple offset technology for lower pressures.

Endurance TM Conductivity Sensors

Solution Overview. Asset Condition Monitoring. Extend operational life and reduce downtime

Installation, Operation and Maintenance Manual RGS Rev. 0 November Bettis RGS F-Series Spring-Return Actuators

Zero Point Calibration HART Communicating Fisher FIELDVUE DVC6200 Digital Valve Controllers

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016

PressureGuard. Self-Contained Hydraulic Emergency Shutdown Systems For Rotary or Non API 6A Linear Valves

Conveyor Condition Monitoring. Increase uptime, decrease damage, plan repairs, avoid disaster

REMY TECHNICAL SERVICE BULLETIN

CSI 2140 Machinery Health Analyzer

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

Shafer Poppet Block Control

Caterpillar C3600 Diesel Engines Operation Maintenance & Troubleshooting

Transforming Transforming Advanced transformer control and monitoring with TEC

MCE TM Product Information 5 kv Electric Motor Analyzer

Low and medium voltage service. Power Care Customer Support Agreements

distribution An automatic solution to enhancing productivity, profitability and environmental performance ALLISON TRANSMISSION EUROPE

Steam Turbine Seal Rub

Baumann Sanitary Angle Control Valve

A softstarter beyond the ordinary

GTD-Series. Direct Gas Actuators

Installation, Operation and Maintenance Manual HP/DHV Rev. 1 November Shafer Hand Pump-Double Holding Valve

Asian paper mill increases control system utilization with ABB Advanced Services

Shafer SH Series Actuator. Service Manual SHSM Rev. 1 September 2016

Multiport Flow Selector. Compact And Economical Production Test Manifold

Application Note. Case study Early fault detection of unique pump bearing faults at a major US refinery

MAINTENANCE TECHNIQUES and GEAR UNIT FAILURE MODES. MIKE FIELD DAVID BROWN GEAR INDUSTRIES Revision 1

M Series Manual Handwheel Gear Actuator

CBB-Series Scotch-Yoke Pneumatic Actuators Improved Design - Compact, Lightweight To Suit All Applications And Environment

BETTIS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS FOR PNEUMATIC ROTARY VALVE ACTUATORS

Automotive and transportation. Magneti Marelli

Adaptive Vibration Condition Monitoring Techniques for Local Tooth Damage in Gearbox

HPUs Hydraulic Power Units

Synchronous Belt Failure Analysis Guide

Routine Compressor Maintenance

Self-powered, On-board, Wireless Condition, Preventive, & Predictive Monitoring. Keith J. Abate Sr. SR. Dir. Business Development Perpetuum Rail

Technical Data Sheet , Rev HB October Rosemount 8800 Vortex Installation Effects

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Transcription:

Expand your vibration program to new heights. Cooling Tower Monitoring Wireless Vibration Monitoring for Motor and Gearbox Combination

Monitoring your cooling towers presents a unique set of challenges Cooling towers are particularly complex to monitor they have many of the same characteristics as other rotating equipment, but come with a unique set of challenges. Cooling tower fans operate under different load conditions. They often only run at peak load for short periods. With differing stresses over a prolonged period, the mechanical components can develop degraded performance, which leads to failure. As with any rotating equipment, bearing and gear failures, misaligned drive shafts, and excessive vibration are common. But the structure of a cooling tower makes collecting vibration data on the gearbox difficult and dangerous without permanently installed sensors. Because the gearbox is a typical failure point, lack of feedback on the machine s health puts you at risk for unexpected failure. Predictive diagnostics can identify the following types of faults in cooling towers: Imbalance Resonance Water intrusion Misaligned gears Misaligned drive shaft Bent shaft Rolling element bearing failure Damaged couplings Chipped, broken or worn gear teeth Lubrication problems Structural and mechanical looseness 2

Simplify vibration monitoring of a cooling tower fan Access to continuous information allows you to detect problems before they lead to failure. As part of Emerson s wireless sensing network solution, the AMS 9420 Wireless Vibration Transmitter provides insight into the health of cooling tower gearboxes and motors. Vibration alerts warn of pending problems, enabling further investigation to detect and diagnose the fault so maintenance can be scheduled. Overall vibration with embedded temperature measurement will identify developing mechanical faults. Emerson s unique PeakVue technology provides advanced diagnostics for early indication of bearing and gearbox faults. Vibration energy bands enhance trending and alarming, making it easier to interpret the data. More detailed information can be accessed through high resolution spectra and waveform data. Trend values can be compared against appropriate alert levels, informing you when the condition of the gearbox or motor is deteriorating as well as providing the underlying cause of the problem. Vibration monitoring data is communicated over a self-organizing network, removing the additional costs associated with running cables. 3

Diagnose vibration faults on mechanical equipment The AMS 9420 delivers insight on the health and performance of previously inaccessible cooling tower gearboxes and motors. Vibration diagnostic data allows reliability specialists to analyze and troubleshoot developing issues. AMS Software Applications Asset dashboard displaying health of the asset, sensor, and transmitter High resolution spectra, waveform data, and vibration energy bands for enhanced trending and analysis Looseness Excessive coupling wear can lead to looseness. Bearing looseness can also cause severe problems on the motor or gearbox, which are particularly important to detect. LAN Network (control system) AMS 9420 Wireless Vibration Transmitter Smart Wireless Gateway or other WirelessHART gateway Standard accelerometer Accelerometer with embedded temperature Imbalance The impeller often has holes in the blades to remove condensation. These can become filled with water, causing imbalance. Other causes of increased imbalance are a crack, bent shaft, or missing shaft keyway. Imbalance can be aggravated by resonance. 4

Bearing Defects Bearings often operate under heavy, variable load and extreme environmental conditions. Because of the force applied to bearings in a cooling tower, defects often progress quickly and lead to friction, bearing damage, and gearbox failure. Shaft Misalignment Due to the length of the shaft in a cooling tower and the thermal changes that the shaft experiences, misalignment is a common issue. Stress inside the shaft can damage couplings, cause bearing fatigue, and even lead to shaft breakage. Broken/Chipped/Worn Teeth Shaft misalignment causes increased load on the input gear, which causes bad meshing of the gears and generates debris. Damaged and misaligned gears can result in failure of the gearbox. Coupling Issue Excessive shaft misalignment can damage the coupling, which can lead to shaft separation. Severe coupling damage can lead to gearbox failure, damaged shafts, and rotor cracks. Insufficient Lubrication The extreme conditions of the cooling tower often lead to issues with lubrication. Bearing wear and gear teeth damage caused by insufficient lubrication contributes to premature equipment failure. However, the inaccessibility of a cooling tower makes it virtually impossible to perform accurate grease and oil analysis. 5

Access data for valuable information Collecting data from the rotating assets inside your cooling tower is just the first step. Accessing, understanding, and sharing the information from that data is critical to identifying developing faults and avoiding unexpected shutdowns. Advanced diagnostic data can be displayed and trended in AMS Machinery Manager software. The Machinery Manager dashboard displays the health of the motor and gearboxes being monitored along with detailed diagnostic data such as vibration energy bands and thumbnail spectra for discovering imbalance, misalignment, and mechanical looseness. Using PeakVue technology, users can separate stress waves from overall vibration data for accurate, early identification of wear on bearings and gearboxes. 6 The comparison of vibration data to an alert level provides both an alarm notification when the asset condition is deteriorating and information about the underlying cause of the problem. This allows operators to take action to protect the asset, while maintenance personnel can diagnose the root cause and schedule work. Now with the introduction of Emerson s Plantweb Optics collaboration software, key personnel can be alerted on their mobile device to the overall health or developing problems in critical assets. Plantweb Optics allows users to connect back to AMS Machinery Manager or AMS Device Manager for more data to determine the appropriate course of action.

Emerson offers integrated solutions for cooling towers The AMS 9420, together with AMS software, provides an early warning of vibration problems. This is just one of a portfolio of integrated wireless technology for cooling towers. Rosemount Pressure Transmitter Detects variations in discharge pressure, an early warning of impending suction strainer plugging, which can lead to cavitation, impeller damage, and seal failure in cooling tower pumps. Rosemount DP Flowmeter Provides high performance flow measurements to give valuable insight into cooling tower operation. Cooling water supply and return flows are an indication of cooling tower performance and can indicate potential problems with an associated pump. Rosemount Level Transmitter Provides high/low level indication of water level in the cooling tower system. Rosemount Temperature Transmitter Enables temperature measurements to determine heat transfer efficiency in cooling towers. Ideal for this high-performance application to enable optimization of cooling tower at a lower cost. Rosemount Guided Wave Radar Use with the Wireless THUM Adapter Enables continuous measurement of the water basin level, ensuring adequate supply of cooled water for the heat exchangers while preventing overfills. Rosemount Dual-Input Analyzer Use with the Wireless THUM Adapter and Toroidal Conductivity Sensor Monitors conductivity, an indication of dissolved solids concentration (leading to build-up of scale), so that adjustments to blowdown rate can be made. 7

Streamline maintenance and maintain throughput by knowing the health of your cooling towers. North America 835 Innovation Drive Knoxville, TN 37932 USA +1 865 675 2400 South America Av. del Valle 601,4to piso, Ciudad Empresarial, Santiago Chile +56 2 4310 7432 Europe Katzbergstr. 1 40764 Langenfeld (Rhld.) +49 0 2173 3348 0 +49 0 2173 3348 100 Asia/Australia 1 Pandan Crescent Singapore 128461 +65 6777 8211 +65 6777 0947 www.emerson.com/smartwireless 2015-2018, Emerson. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. The AMS logo is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while diligent efforts were made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Middle East/Africa PO Box 17033 Dubai - United Arab Emirates +971 4 811 8100 +971 4 886 5465