Electronic Ballast EVG 2000-T

Similar documents
World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Model Number Structure

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

SINAMICS GM150 IGCT version

RVS-AX Instruction Manual

HIGH POWER SOLENOID DRIVER 1

ATOTH-G Series BLDC Motor Controller. User s Manual

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

TECHNICAL DATA SHEET KVA UPS Systemss

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Technical Data Sheets

EPS/ELA-Series User Manual EPS/ELA 250W

Essential equipment for all your requirements

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

QS20.241, QS C1

Commissioning Instructions Inbetriebnahme Anleitung VB 230/ L (LP)

Technical Data Sheets

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Phoenix Inverter

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

Technical Data Sheets

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

Operating Instructions. Angle Seat Control Valve. Type 7020

.3 Section Waste Management and Disposal.

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

SPEEDRIVE INSTRUCTIONS MANUAL

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

RT2DB Excitation and voltage regulation system for synchronous generators

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Operating instructions EWB 200

Components for EEx e Panels

Frame size R2, IP20 / NEMA 1

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Operating manual UPS - System

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

SAVER DSP SERIES. 3-10kVA USER MANUAL

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Switchmode rectifier type RKAS with PFC

Braking Devices VB 230/ Assembly- and Commissioning Instructions

Brake Chopper BC BC 4.1. Instruction and Operation Manual

Emergency lighting units EM powerled

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Braking Devices BR 230/ Assembly- and Commissioning Instructions

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

LED Driver Compact fixed output

LED Driver Compact fixed output

Ceramic PTC Thermistor:

Induction Power Supplies

ABB machinery drives. Application guide Common DC system for ACS380 drives

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Electronic Circuit Breaker ESS20

LED Driver Linear / area fixed output

Safety Sensor CSS 180 Product Information

Electronic Circuit Breaker ESS20-0..

Digital Pressure Regulator Sentronic PLUS Series 614

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

EGQ 212: Duct transducer, CO 2 and temperature

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

TX³ RCCBs 2P up to 100 A

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Operation Instructions

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

Emergency lighting units EM powerled

5. OVERCURRENT RELEASE (OCR)

Power Supply EL

Modular contactor for installation into distribution boards

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

BETA Switching Switches and Light Indicators

TECHNICAL DESCRIPTION

Electronic circuit breaker EBU10-T

User Manual Rittal PMC UPS 6kVA

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Control Relays Overview

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Transcription:

Electronic Ballast EVG 2000-T Operating Manual

Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications and signalling... 6 1.6 Switch-on behaviour in case of... 7 1.7 Cooling... 7 1.8 Safety requirements when using the unit together with ultraviolet lamps... 7 1.9 Repairs... 7 2 Technical data 2.1 Mains connection... 8 2.2 Lamp connection... 8 2.3 Connection plug arrangements... 9 05.06.2008 Page 2 technical changes reserve

1 Description 1.1 Advantages of this ballast Lamp power can be adjusted steplessly Lamp power can be automatically controlled to a constant value set Different lamps can be connected to the same ballast It is possible to operate nearly all types of mercury vapour medium-pressure lamps and metal halide lamps (doped mercury vapour lamps) the electrical characteristics of which are in the wide operating range of unit Lamp power can be pulsed quickly All functions are controlled via galvanically separate analogue inputs DC 0...10 V or 4...20 ma Any voltage variations are compensated Easy to install by little wiring work Smaller and lighter than a comparable conventional ballast Air cooling Advanced technology with digital control The ballast meets the requirements of DIN EN 50178 / VDE 0160 and other European and global standards (IEC). 1.2 Functional principle The EVG 2000-T unit is an electronic, controllable AC ballast for lamps of a nominal power from 500 W to 2000 W which is intended to be used for industrial applications. The unit is designed for the operation with lamps. The lamps are operated by a square-wave current, and thus the dark phase in the current s zero passage as usual in conventional ballasts. The EVG 2000-T unit s function is based on a controllable power source up to 14 A. During the operation the lamp power is controlled and kept constant at an external set value via an internal control unit. The lamp s nominal voltage may be between approx. 100 V and 300 V. However, in order to get the full power of 2000 W, the maximum current of 14 A should be considered so that a minimum lamp voltage of 145 V is necessary. In most lamps the power can be adjusted from approx. 10 to 100 %, depending on the cooling and ambient conditions. Using the integral power control unit, the lamp power is set from the outside via an analogue input (DC 0...10 V or 4...20 ma). Doing so, the minimum and maximum values as necessary and allowable for each lamp must be taken into account. This control unit is used to control the set point to a constant value, i.e. to keep the lamp power constant, irrespective e.g. of the voltage or different lamp voltages. The EVG 2000-T unit has a galvanic separation between the main and control circuit and can be controlled directly, e.g. by a stored-program control (SPS), via DC 0...10 V/4...20 ma input. If DC < 1V at the input, the lamp is switched off (no safe disconnection as required by VDE because here semiconductors are used to switch! For this reason, a main switch or a relevant contactor is necessary in case of servicing work, e.g. for replacing the lamp). By de, the unit is equipped in the factory with an internal, temperature-controlled ventilator (keep in mind that the maximum cooling air temperature is 40 C!). The cooling air may not be contaminated or exert any other negative influence on the electronics (e.g. by aggressive gases or high humidity). The EVG 2000-T ballast can be used as a tabletop unit or installed in a switch cabinet etc. General note for electric measurements! For measurements around the ballast, e.g. to measure the and lamp currents or voltages, a true RMS measuring instrument with a frequency range of up to at least 10 khz is necessary. In most cases, other instruments do not indicate the correct values, in particular, the lamp current and voltage. When measuring the lamp voltage, be aware of the fact that ignition pulses may destruct the measuring instrument. 05.06.2008 Page 3 technical changes reserve

1.3 Energization Potentiometer for Powercontrol (For using the Potentiometer pin 2 and 7 from connection 1 bridged) Switch for Operation Mode intern / extern Status-LED refer to Chapter 1.5 Amperemeter Lamp Voltage Connection 2 refer to Chapter 2.3 Connection 1 refer to Chapter 2.3 Voltmeter Lamp Voltage RS232 refer to Chapter 1.4 Cooling air ventilator Air inlet Note: The inputs and outputs have a delay of 3 s from switching ON the, in order to avoid an uncontrolled behaviour during the internal run-up. Analogue power control input: (use a shielded cable!) Signals of EVG 2000-T : Potentiometer (R > 2k) or DC 0...10V (Ri < 10k) and DC 4...20 ma (has priority to DC 0...10V input) DC < 0.9V = OFF DC > 1V = ON and igniting DC 1...10V = ON; lamp power 10...100% or 4 20 ma (Ri = 250 ) 4 5.5 ma = OFF 5.6 20 ma = ON; lamp power 10...100% within the current limits ~1.4...14.4 A Multicolour LED (green, orange, red) to signal the status Potential-free change-over contact to signal a trouble 2 outputs for external LEDs : 1 output indicates OK by a green LED to be provided by the customer 1 output indicates FAULT by a red LED to be provided by the customer A 220 Ohm resistor is integrated in EVG 2000-T for each output. The typical LED current is 10mA each. RS232 interface: Integrated (refer to 1.4) Note: Reset: In case of, do not immediately disconnect the EVG 2000-T from the because, otherwise, the reason of is not issued. is possible by disconnecting from for at least 10 s (e.g. after a message) 05.06.2008 Page 4 technical changes reserve

1.4 Visualization Optionally, the ballast is delivered with a serial interface and visualization software. The visualization system shows all s found in the EVG 2000 ballast as well as the internal measuring values. The maximum output power is parameterized via the software, too. Parameters and data in the ballast Parameter input Maximum power Maximum output power Setpoint Output power Send data Output voltage Output current Fault bit Intermediate circuit voltage Start Intermediate circuit current Short circuit Temperature / PFC Line-to-earth Temperature / PWM Mains undervoltage Mains voltage Overtemperature Status Ventilator ON Intermediate circuit overvoltage Start-up Intermediate circuit undervoltage Maximum power Intermediate circuit overcurrent Operating: Sio-Start Sio-Stop Sio-Status Versions EVG Send Data Exit Communication is started; RS232 interface is configured by the visualization software. Communication is stopped; RS232 interface is released for other programs Red: Communication not started or stopped Yellow: Communication erroneous Green: Communication OK Firmware version is read out The value adjusted in the field Maximum output power is transmitted to the ballast. Program is ended 05.06.2008 Page 5 technical changes reserve

1.5 Indications and signalling On the casing of the EVG 2000-T ballast there is a three-colour light-emitting diode to signalize different states. In addition, a potential-free change-over contact is available to identify any troubles. Some interconnections are shown in the table below: Operating mode Normal Warning Fault LED Diagnosis Status Signalling contact Remark LED green, lights permanently LED green, long LED orange, lights permanently LED orange, short LED red/orange, short LED red/orange, long LED red, long LED red, short LED red, lights permanently Energization voltage 1.0V Energization voltage < 0.9V Energization voltage 1.0V Risk of overtemperature (heat sink temperature >70 C, reset at <65 C) Mains voltage <190 V (but not 0 V) Overtemperature (heat sink temperature >80 C, reset at <75 C) Output circuit is open or the lamp does not ignite Short circuit in the output circuit Line-to-earth in the output circuit Desired power is reached (depending on the energization voltage) Ballast is ready for switching ON Lamp voltage is too low, desired power is not reached, no load (10 s) Unit re in switched ON state OFF, OFF, OFF, no lamp is connected or the lamp does not ignite OFF OFF Relay has released, no Relay has released, no Relay has released, no Relay has released, no Storing, reset is possible by Storing, reset is possible by Wait for three ignition attempts. Storing. Reset is possible by Storing, reset is possible by ( Short circuit may also be induced if the lamp s start voltage is too low, <10V for 10s) Storing, reset is possible by Flashing frequencies: Long = 1s ON, 1s OFF (0.5 Hz); short = 2x per second ON (2 Hz) 05.06.2008 Page 6 technical changes reserve

1.6 Switch-on behaviour in case of The lamp does not ignite or is not connected: The EVG 2000-T ballast attempts for 10 s to ignite the lamp (LED orange, lights permanently; potential-free changeover contact has pulled up). If the lamp does not ignite within this time, a break of 30 seconds will follow. During this break the LED is flashing red with a low frequency and the potential-free change-over contact has pulled up. After the first ignition attempt was not successful, a second ignition attempt and, if necessary, a third ignition attempt is made in the above-described manner. After the third ignition attempt the unit will remain in the status and the red LED is long. In order to be able to start a fourth and further ignition attempts, it is necessary to disconnect the unit from the power supply and then to switch ON again. 1.7 Cooling In order to guarantee the maximum power output and life of the EVG 2000-T ballast, it is important to efficiently cool the unit. The cooling effect depends on the air volume flowing through the heat sink and the air temperature. To reach the full power output of up to 2000 W, the air temperature may not be higher than 40 C. Pay attention to this fact, in particular, when the unit is installed in a switch cabinet or a similar casing. Arrangements should be made to ensure that the lost heat of the unit can be sufficiently dissipated! The EVG 2000-T ballast is equipped with a temperature-controlled ventilator and is independently switched ON or OFF if a defined heat sink temperature is reached. Note for controlling the ventilator! If the ballast is disconnected from the, the ventilator continues to run for approx. 10 s and, doing so, it discharges the intermediate circuit capacitors. 1.8 Safety requirements when using the unit together with ultraviolet lamps Before starting any work at the connections of the ballast or UV lamp, e.g. when replacing the lamp, it is necessary to completely disconnect the unit from the by actuating the main contactor or main switch, to preclude the risk of an electrical shock. After having switched OFF the unit, wait still for 10 minutes to ensure that the capacitors can be discharged to a nonhazardous value. Reason: According to the operation principle, the ultraviolet lamp is switched OFF by semiconductors. However, this does not involve a safe the as required by VDE! There is the risk of residual voltages!! Danger to life! 1.9 Repairs The EVG 2000-T ballast is a reliable electronic unit which, according to experience gained hitherto, may be hardly damaged. If, contrary to expectations, this should be happen the unit may be repaired by replacing the defective parts and subsequent detailed performance test at the factory. 05.06.2008 Page 7 technical changes reserve

2 Technical data Electrical data of the trouble signalling contact: Protection against short circuit and overload in the lamp circuit: Protection against line-to-earth in the lamp circuit: Nominal voltages AC 250 V / DC 30 V Maximum continuous current 16 A Maximum switching capacity (AC) 500W / 750VA Maximum switching current (AC with 230V) Maximum switching current (DC with 30 V) Minimum switching load 300 mw, 5 V, 5 ma yes yes 30 A 16 A Efficiency: > 91% Ambient temperature: 5 C to 50 C Mounting position: Longitudinal axis in horizontal position Dimensions: 263 x 173 x 340 mm (w x h x d) Weight: 8.5 kg 2.1 Mains connection Mains voltage and frequency: Connection: Power factor: 196 to 255V at 50 and 60Hz L1, N and PE > 0.996 (with full load) THDi : < 3.0% Fuse /: - Protective motor switch (tripping current Ia is calculated as follows) Ia = PS * 1.15/ UNetz wherein PS = maximum lamp power desired, in W Unetz = actual minimum voltage - B 16 automatic circuit breaker Peak value of starting current when is switched ON: Typically approx. 35A (10ms) Peak value of starting current when the lamp is switched ON: No EMC: DIN EN 55011/VDE 0875 Part 11, class A, group 1 When used in residential areas (class B, group 1), an additional external line filter is necessary. Fault-current circuit breaker: When -current circuit breakers are used, the units shall have a DC tripping system. Main switch or protective motor switch A contactor is necessary to safely disconnect the unit from as specified by IEC and VDE regulations, in order to avoid any residual voltages at the lamp connection. Instead of the contactor, the disconnecting function can also be implemented by a main switch or a suitable protective switch. 2.2 Lamp connection Output frequency: Maximum lamp current: Lamp voltage: No-load voltage: 55 Hz, square wave 14.4 A 100 V to 300 V 420 V 05.06.2008 Page 8 technical changes reserve

Maximum lamp power: 2000 W (with lamp voltages > 145 V) Pulse operation: Rise time / lamp current 50 ms Fall time / lamp current 50 ms Maximum cable length between EVG 2000-T and ignitor: 30 m Maximum cable lengths between the ignitor and lamp: for Hg lamps 5 m (these values depend on the cable and lamp types used) for doped lamps 3 m For reasons of electromagnetic compatibility, the cables/lines to the lamp shall be of shielded type. The shield may be earthed on one (!) side only, preferably on the side of the ballast, and led from both lines and the EVG 2000-T unit to a common point! IMPORTANT!! The ignitor is integrated and is switched OFF after 10s!! IMPORTANT!! The cable capacitance between the EVG and lamp may not exceed 1nF (measured from pole to shield). Otherwise, the EVG 2000-T unit will switch OFF itself by sending a line-to-earth message!! 2.3 Connection plug arrangements Connection plug, 10-pole 1 GND 2 Analogue input for power adjustment DC 0V..10V 3 10V output for potentiometer f. power adjustment (10k, max. 8mA) 4 Analogue input for power adjustment DC 4mA..20mA (priority to pin 2) 5 Analogue output DC10V, proportional to the lamp power (10V = 2000W) 6 Reserve 7 GND 8 Anode for external LED green, 10mA, ballast in the EVG unit 9 Anode for external LED red, 10mA, ballast in the EVG unit 10 Maximum power specification, L-aktiv (priority to analogue inputs for desired values) Connection plug, 3-pole 1 Relay contact / NC contact 2 Relay contact / Root 3 Relay contact / NO contact (Relay is pulled up in the status) Use shielded cables! The shield shall be earthed on one side only, together with the ballast, to one common point near the EVG unit! Lamp connection Maximum cable length between the lamp and ignitor: 5m WARNING: When doing any work on the lamp connections, always disconnect the ballast from the! Residual voltages possible! 05.06.2008 Page 9 technical changes reserve