Accessories for bus connection DeviceNet, CANopen and Modbus-RTU

Similar documents
FBP PROFIBUS DP Accessories

Motor Starter Reverse MSR22-FBP

SAC-4P-M12MS/ 5,0-PUR SH

SAC-5P-3,0-PUR/M12FS SH

Clearwater Tech - Phone: Fax: Web: -

Technical Description. Wireless Automation Accessories

Han-Power Energy Bus Components

INFORMATION. Hybrid cables. Description

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

- 1 - General ordering data Order No

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

FISCHER FREEDOM TM SERIES

EURO-STYLE INDEX. Page:D-02. Page:D-06. Page:D-03. Page:D-07. Page:D-04. Page:D-08. Page:D-05 D-01. Euro-style/Male/Straight

6000 Series Ethernet Buccaneer

Cables for Railway Technology

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

Directory chapter 08. InduCom Robust and EMI protected D-Sub interfaces

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

DIN Valve Connectors - VAD 1A/1B Series

Ethernet Buccaneer BUCCANEER DATA. bulgin

Mini contactors B6, BC6 with 3 pole

Cables for cable carriers and reels SYSTEMS IN MOTION

Ethernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

06. har-mik INTERFACE CONNECTORS

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

General characteristics and technical data Series MCS

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 115 CY

Coupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut

CF270.UL.D.

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Industrial Ethernet Cables

Electronic pressure switch with integrated analogue output

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

Telephone Cables Fire Warning Cables

PROFIBUS PA Physical Media Connectivity

Electronic overload relay EF65, EF96 and EF146

SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

Thermal overload relay TF65 and TF96

Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D

DNV-GL HH CE RoHS-II conform

Cable systems We offer you the essential components for a future-oriented e-mobility.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia

Electronic overload relays EF205 and EF370

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

FACTORY AUTOMATION. System Accessories for Mounting and Connection

Contents. Fieldbus, data cables and accessories. Fieldbus, data cables and accessories C.1. Introduction C.2. Fieldbus distributor - Overview C.

Conectores Rectangulares

MOTOR, SERVO, & FEEDBACK CABLES

Connector- and Housing technology

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

M8 Series. Key features: BUCCANEER

Manual motor starter MS132

Scroll down to view your document!

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable

Pressure Relief Device Comem PRD Order sheet

Technical attributes

µcom-10gb + Harsh Environment 10Gb Ethernet Micro Connectors

Manual motor starter MS132

Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No

Thermal overload relay TF140DU and TF140DU-V1000

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

14 HH EAC/CTP CE RoHS-II conform

Momentum. Technologies GmbH IE 4. oil-less. MTS82 Synchronous Drum Motor. Partner Company. Efficiency. Momentum MTS US

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CTF. Connectors

Automotive products. RADOX cables and system solutions. Edition 2018/02

TURCK Network Media Products PROFIBUS -DP

ATEX/IECEx RTD temperature probe

Female socket block, Screw connection, No. of poles: 12, Width: mm, Colour: Green

LS Total Solution for Photovoltaic

Ph: Product Catalogue Industrial Cables Hazardous area equipment Cable termination

PPT 802, Proximity Probe Transducer System

Cables for Airport Equipment

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

INSTRUMENTATION CABLE

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head

Electronic pressure switch with two switching outputs

ABB i-bus KNX DG/S x DALI-Gateway Basic

Crimpmate Range pitch 5.00

Mineral-Insulated RTD Temperature Probe According to DIN EN 60751

DIN rail enclosures. Combirail Alurail CombiNorm-Connect CombiNorm-Compact CombiNorm-Classic

CSF - CSM CONNECTORS. Functional characteristics. RoHS 2011/65/EU. Brief description. Dimensional class: low. Standard colour: green

Momentum. Technologies GmbH IE 4. oil-less. MTS113 MTS114 Synchronous Drum Motor. Partner Company. Efficiency. Momentum MTS113 MTS US

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Push-in RTD Temperature Probe with Connecting Cable

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Effective and flexible energy distribution. Conductor Rails. for electronic components. Multilayer Bus-Bar

Transcription:

FBP FieldBusPlug V6 Accessories for bus connection DeviceNet, CANopen and Modbus-RTU

V6 FieldBusPlug Accessories for bus connection DeviceNet, CANopen and Modbus-RTU Contents Technical data Page DNX11-FBP.100 Extension cables (lengths 1 m, 3 m, 5 m)... 4 DNF11-FBP.030 Round cable, female plug attached to one end, 0.5 m, sheath partially removed, wire-end ferrules attached... 5 DNM11-FBP.030 Round cable, male plug attached to one end, 0.5 m, sheath partially removed, wire-end ferrules attached... 6 DNC11-FBP.999 Round cable 100 m (drop cable)... 7 DNM11-FBP.0 Round cable male connector... 8 DNF11-FBP.0 Round cable female connector... 9 DNR11-FBP.120 Terminating resistor... 10 Technical changes reserved DeviceNet, CANopen, Modbus-RTU FieldBusPlug Accessories 3

FieldBusPlug V 6 DNX11-FBP.100, DNX11-FBP.300, DNX11-FBP.500 Extension cables (lengths 1 m, 3 m, 5 m) Connection cable, socket/plug (M12) with self-locking screwed connection Temperature range -25 C... + 90 C Materials Moulded body TPU, self-exstinguishing Contact (female) CuSn, pre-nickeled and 0.3 µm gold-plated Contact (male) CuZn, pre-nickeled and 0.8 µm gold-plated Body TPU, self-exstinguishing Knurled screw, knurled nut CuZn, nickeled O-ring Viton Degree of protection IP 68 (only in fully locked position with their plugs) Good resistance to oil and chemicals. Use of this connector range in aggressive environments must be tested in each case. Electrical data Max. current load 4 A (CSA = 3 A) Nominal voltage 30 V AC / 36 V DC Insulation group C acc. to VDE 0110 1.5 kv AC / 60 s Insulation resistance > 10 9 Ω Cable data Number of poles 5 Colours of cores 1 = SHIELD (bare flexible lead) 2 = red (+24 V DC) 3 = black (0 V) 4 = white (CAN_H) 5 = blue (CAN_L) Sheath/jacket PUR (free of PVC and halogen) Cable colour black Further cable data see page 7 Order numbers DNX11-FBP.100 1SAJ 923 001 R0010 female male DNX11-FBP.300 1SAJ 923 001 R0030 DNX11-FBP.500 1SAJ 923 001 R0050 4 DeviceNet, CANopen, Modbus-RTU FieldBusPlug Accessories

V6 FieldBusPlug DNF11-FBP.050 Round cable with female plug, 0.5 m Female connector with self-locking screwed connection and integrally extruded cable Difference to standard: Cable end sheath stripped 50 mm in length with shrunk-on insulation sleeving, wire-end ferrules attached to the cores Temperature range -25 C... + 90 C Materials Moulded body Contact Body Knurled nut O-ring TPU, self-exstinguishing CuZn, pre-nickeled and 0.3 µm gold-plated TPU, self-exstinguishing CuZn, nickeled Viton Degree of protection IP 68 (only in fully locked position with their plugs) Good resistance to oil and chemicals. Use of this connector range in aggressive environments must be tested in each case. Electrical data Max. current load 4 A (CSA = 3 A) Nominal voltage 30 V AC / 36 V DC Insulation group C acc. to VDE 0110 1.5 kv AC / 60 s Insulation resistance > 10 9 Ω Cable data Number of poles 5 Colours of cores 1 = SHIELD (bare flexible lead) 2 = red (+24 V DC) 3 = black (0 V) 4 = white (CAN_H) 5 = blue (CAN_L) Sheath/jacket PUR (free of PVC and halogen) Cable colour black Further cable data see page 7 Order number DNF11-FBP.050 1SAJ 923 002 R0005 female DeviceNet, CANopen, Modbus-RTU FieldBusPlug Accessories 5

FieldBusPlug V 6 DNM11-FBP.050 Round cable with male plug, 0.5m Male connector with self-locking screwed connection and integrally extruded cable Difference to standard: Cable end sheath stripped 50 mm in length with shrunk-on insulation sleeving, wire-end ferrules attached to the cores Temperature range -25 C... + 90 C Materials Moulded body Contact Body Knurled nut O-ring TPU, self-exstinguishing CuZn, pre-nickeled and 0.8 µm gold-plated TPU, self-exstinguishing CuZn, nickeled Viton Degree of protection IP 68 (only in fully locked position with their plugs) Good resistance to oil and chemicals. Use of this connector range in aggressive environments must be tested in each case. Electrical data Max. current load 4 A (CSA = 3 A) Nomonal voltage 30 V AC / 36 V DC Insulation group C acc. to VDE 0110 1.5kV AC / 60 s Insulation resistance > 10 9 Ω Cable data Number of poles 5 Colours of cores 1 = SHIELD (bare flexible lead) 2 = red (+24 V DC) 3 = black (0 V) 4 = white (CAN_H) 5 = blue (CAN_L) Sheath/jacket PUR (free of PVC and halogen) Cable colour black Further cable data see page 7 Order number DNM11-FBP.050 1SAJ 9223 003 R0005 male 6 DeviceNet, CANopen, Modbus-RTU FieldBusPlug Accessories

V6 FieldBusPlug DNC11-FBP.999 Drop cable 100 m Pair 1 Extension cable (ring) Construction Supply voltage Conductors Core insulation Core colours Data lines Conductors Core insulation Core colours Shielding Bare flexible lead Common shield Sheath/jacket Electrical data Supply voltage Conductor resistance Insulation resistance Data lines Conductor resistance Insulation resistance Capacity in operation Attenuation Impedance 22 AWG (0.34 mm 2 ), tinned TPE red and black 24 AWG (0.25 mm 2 ), tinned Cell-PE blue and white each pair of cores with AL-PT foil, covering 100 %, cores are twisted in pairs 22 AWG (0.34 mm 2 ), tinned C shield, tinned, covering ca. 65 % PUR dull, Ø 6.8 mm colour: black 1.2 kv AC 57.4 Ω/km 10 12 Ω/km 1.2 kv AC 91.9 Ω/km 10 12 Ω/km 39 pf/m, 0.8-1.2 MHz (A/A) 79 pf/m, 0.8-1.2 MHz (A/S) 9.5 db/km, 125 khz 16.4 db/km, 500 khz 22.9 db/km, 1 MHz 120 Ω ± 10 %, 1 MHz Pair 2 Other data Order number DNC11-FBP.999 can be used as trailing cable, bending radius min. 100 mm, temperature range, static: -40 C / +70 C temperature range, under movement: -10 C / +70 C meets DeviceNet specifications, inflammability according to DIN VDE 0472-804 test type B, cable is free of halogen and PVC, good resistance to oil, chemicals, hydrolysis and mikrobes 1SAJ 923 004 R1000 Technical changes reserved DeviceNet, CANopen, Modbus-RTU FieldBusPlug Accessories 7

FieldBusPlug V 6 DNM11-FBP.0 Male connector for round cable Male connector with screwed connection, for cable Temperature range -25 C... + 90 C Materials Moulded body Contact Body Knurled screw O-ring PA, self-exstinguishing CuZn, 2-4 µm CuSnZn PA, self-exstinguishing CuZn, nickeled NBR or FKM Degree of protection IP 67 (only in fully locked position with their plugs) Good resistance to oil and chemicals. Use of this connector range in aggressive environments must be tested in each case. Electrical data Max. current load 4 A Nominal voltage 30 V AC / 36 V DC Insulation group C acc. to VDE 0110 1.0 kv AC / 60 s Insulation resistance > 10 9 Ω Connection data Number of poles 5 pin 5 early-closing Connection type screw-type terminals Cond. cross section max. 0.75 mm 2 Cable gland 4.0... 8.0 mm male SW.. = 19 mm Order number DNM11-FBP.0 1SAJ 923 005 R0001 8 DeviceNet, CANopen, Modbus-RTU FieldBusPlug Accessories

V6 FieldBusPlug DNF11-FBP.0 Female connector for round cable Female connector with screwed connection, for cable Temperature range -25 C... + 90 C Materials Moulded body Contact Body Knurled screw O-ring PA, self-extinguishing CuZn, 2-4 µm CuSnZn PA, self-exstinguishing CuZn, nickeled NBR or FKM Degree of protection IP 67 (only in fully locked position with their plugs) Good resistance to oil and chemicals. Use of this connector range in aggressive environments must be tested in each case. Electrical data Max. current load 4 A Nominal voltage 30 V AC / 36 V DC Insulation group C acc. to VDE 0110 1.25 kv AC / 60 s Insulation resistance > 10 9 Ω Connection data Number of poles 5 Connection type screw-type terminals Cond. cross section max. 0.75 mm 2 Cable gland 4.0... 8.0 mm female SW.. = 19 mm Order number DNF11-FBP.0 1SAJ 923 006 R0001 DeviceNet, CANopen, Modbus-RTU FieldBusPlug Accessories 9

FieldBusPlug V 6 DNR11-FBP.120 Terminating resistor Male plug M 12, 5 poles Temperature range -25 C... + 90 C Materials Moulded body Contact Body Knurled screw PA, self-exstinguishing CuZn, pre-nickeled and 0.8 µm gold-plated TPU, self-exstinguishing CuZn, nickeled Degree of protection IP 67 (only in fully locked position with their plugs) Good resistance to oil and chemicals. Use of this connector range in aggressive environments must be tested in each case. Connection data Number of poles 5 Pin assignment Pins 1-3 = unused Pin 4 120 Ohm Pin 5 male Technical changes reserved Order number ASF11-FBP.0 1SAJ 922 006 R0001 10 DeviceNet, CANopen, Modbus-RTU FieldBusPlug Accessories

Druckschrift-Nr.: 2CDC 193 004 D0202 ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 Postfach 101680 69123 Heidelberg 69006 Heidelberg Germany Germany Telefon (06221) 701-0 Telefax (06221) 701-240 E-Mail desst.helpline@de.abb.com Internet http://www.abb.de/stotz-kontakt