CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

Similar documents
FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

FIELD CONNECTIONS MODEL YK CHILLERS (STYLE F AND G) WITH VARIABLE SPEED DRIVE

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

MODELS SSS 7L-B, 14L-B, 26L-B, 33L-B AND MODELS SSS 7LK-B, 14LK-B, 26LK-B, 33LK-B

WIRING DIAGRAM MODEL YK (STYLE G) LIQUID CHILLERS OPTIVIEW CONTROL CENTER WITH ELECTRO-MECHANICAL STARTER

RENEWAL PARTS Supersedes: RP4 (1012) Form RP4 (813)

WIRING DIAGRAMS MODEL YK (STYLE G) LIQUID CHILLERS OPTIVIEW CONTROL CENTER WITH SSS, LV VSD W/ MODBUS, & MV VSD

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

MODEL CYK CHILLER WITH LIQUID COOLED SOLID STATE STARTER, OR REMOTE STARTER

WATER COOLED AIR CONDITIONING UNITS MODEL CVWSEK-060 WATER SIDE ECONOMIZER FOR CSV060B VERTICAL R-410A STYLE B R-410A

WIRING DIAGRAM, MILLENNIUM TM MODEL YT (STYLE J) LIQUID CHILLERS GRAPHIC CONTROL CENTER WITH ELECTRO-MECHANICAL STARTER PRODUCT DRAWING JOB DATA:

TON KW 60HZ

ELEMENTARY DIAGRAM CONNECTION DIAGRAM CONTROL PANEL AND CONNECTION DIAGRAM SYSTEM WIRING FOR MODELS:

R-410A KW 50HZ

FOR OT/HT MODEL CHILLERS STYLE B AND C CONTROL CENTERS , AND

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Water to Water Geothermal Heat Pump 3-Phase Models Both 208 & 480

YCAL0014E_ - YCAL0124E_ R-22 & HFC-407C STYLE C (60 Hz)

WATER-COOLED SELF-CONTAINED UNITS MODEL CVWSEK-060BK/DP WATERSIDE ECONOMIZER FOR CSV060B LEFT-HAND VERTICAL R-410A STYLE B

QTC2015T, 020T, 025T, 030T, 035T, 040T, and 045T

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz)

Wiring Diagrams DIAGRAM INDEX

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

Electrical Design/Build Guide

8300 Series Installation Guidelines

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

High Frequency SineWave Guardian TM

Air-Cooled Scroll Compressor Chillers Models AGZ 010A to AGZ 034A Models AGZ 026B to AGZ 130B. Revised Electrical Data Tables.


Installation Instructions

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

RU SERIES UPGRADE TempAssure Compatible

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

5300 Series Installation Guidelines

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Electrical Installation

Model CPV120 Waterside Economizer Kit WATERSIDE ECONOMIZER KIT FOR MODEL CPV 120 WATER-COOLED AIR CONDITIONERS INSTALLATION INSTRUCTIONS

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

R-410A 50Hz & 60Hz. Renewal parts /3/ MODELS ONLY. Issue Date: September 07, 2011

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Technical Manual. DLM Module. This manual should remain with the unit.

Owner's/Installation Manual

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

ACCESSORY KIT INSTALLATION INSTRUCTIONS

A WORD ABOUT PROPER GROUNDING

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO:

CONTROLS AND INSTRUMENTATION MODEL YST STEAM-TURBINE DRIVE CENTRIFUGAL LIQUID CHILLER

Installation Instructions

WATER-COOLED SELF-CONTAINED UNITS MODEL CVWSEK-300BK/DP WATERSIDE ECONOMIZER FOR CSV300B LEFT-HAND VERTICAL R-410A STYLE B

Precision Power Center INSTALLATION, OPERATION, & MAINTENANCE MANUAL

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

ACCESSORY KIT INSTALLATION INSTRUCTIONS

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

MANUAL INSTALLATION. Modular Floor Diffusers. MFD Series. v102 Issue Date: 03/23/ Price Industries Limited. All rights reserved.

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

Installation Instructions Electric Heaters 5 20 kw

MANUAL INSTALLATION. Linear Plenum Terminal. LPT Series. v001 Issue Date: 06/06/ Price Industries Limited. All rights reserved.

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Quick Connection Panel (QCP) Installation Guide

CHAPTER V RESIDENTIAL WIRING

Section 6 Electric Metering: Residential

Installation Instructions

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

WATER-COOLED SELF-CONTAINED UNITS MODEL CVWSEK-120BKR/DPR WATERSIDE ECONOMIZER FOR CSV096B/120B RIGHT-HAND VERTICAL R-410A STYLE B

ACCESSORY KIT INSTALLATION INSTRUCTIONS

TON KW 60HZ

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

ACCESSORY KIT INSTALLATION INSTRUCTIONS

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Electric. PN April Series Electric Oven

Vission 20/20 Retrofit Instructions

09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS

Installation Instructions

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

North America Phase Converters & Electrical Supply

SECTION MOTOR CONTROL

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

SAVE THESE INSTRUCTIONS

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Installation Instructions

2016 Photovoltaic Solar System Plan Review List

Transcription:

WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. Supersedes: 160.80-PW4 (1099) Form: 160.80-PW4 (215) FIELD CONNECTIONS ROTARY SCREW CHILLER WITH GRAPHIC CONTROL CENTER AND YORK MOD B SOLID STATE STARTER YS (STYLE E) PURCHASER JOB NAME LOCATION ENGINEER REFERENCE DATE APPROVAL DATE CONSTRUCTION DATE JOB DATA: CHILLER MODEL NO. YS NO. OF UNITS SOLID STATE STARTER, MODEL NO. SSS, L B MOTOR/STARTER POWER VOLTS, 3-PHASE, HZ OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR OPTIONAL FACTORY INSTALLED CIRCUIT BREAKER AMPS Issue Date: February 4, 2015

IMPORTANT! READ BEFORE PROCEEDING! GENERAL SAFETY GUIDELINES This equipment is a relatively complicated apparatus. During rigging, installation, operation, maintenance, or service, individuals may be exposed to certain components or conditions including, but not limited to: heavy objects, refrigerants, materials under pressure, rotating components, and both high and low voltage. Each of these items has the potential, if misused or handled improperly, to cause bodily injury or death. It is the obligation and responsibility of rigging, installation, and operating/service personnel to identify and recognize these inherent hazards, protect themselves, and proceed safely in completing their tasks. Failure to comply with any of these requirements could result in serious damage to the equipment and the property in which it is situated, as well as severe personal injury or death to themselves and people at the site. This document is intended for use by owner-authorized rigging, installation, and operating/service personnel. It is expected that these individuals possess independent training that will enable them to perform their assigned tasks properly and safely. It is essential that, prior to performing any task on this equipment, this individual shall have read and understood the on-product labels, this document and any referenced materials. This individual shall also be familiar with and comply with all applicable industry and governmental standards and regulations pertaining to the task in question. SAFETY SYMBOLS The following symbols are used in this document to alert the reader to specific situations: Indicates a possible hazardous situation which will result in death or serious injury if proper care is not taken. Identifies a hazard which could lead to damage to the machine, damage to other equipment and/or environmental pollution if proper care is not taken or instructions and are not followed. Indicates a potentially hazardous situation which will result in possible injuries or damage to equipment if proper care is not taken. Highlights additional information useful to the technician in completing the work being performed properly. External wiring, unless specified as an optional connection in the manufacturer s product line, is not to be connected inside the control cabinet. Devices such as relays, switches, transducers and controls and any external wiring must not be installed inside the micro panel. All wiring must be in accordance with Johnson Controls published specifications and must be performed only by a qualified electrician. Johnson Controls will NOT be responsible for damage/problems resulting from improper connections to the controls or application of improper control signals. Failure to follow this warning will void the manufacturer s warranty and cause serious damage to property or personal injury. 2 JOHNSON CONTROLS

NOTES 1. All field wiring shall be in accordance with the current edition of the National Electrical Code (N.E.C.) as well as all other applicable codes and specifications. 2. Solid State Starter shall be grounded in accordance with the 1999 N.E.C. (paragraph 250-118) for equipment grounding. Where a separate grounding conductor is used, it must be a copper conductor only and sized per the 1999 N.E.C. (Table 250-122). Per 1999 N.E.C. (Paragraph 250-(f) (11), where multiple parallel conduits are used, each must contain a grounding conductor. See Note 8 for grounding lug wire range. 3. Wiring, electrical conduit, junction boxes, fused disconnect switches (FDS), or circuit breakers, starters (M), push-button stations (PB), manualoff-automatic switch (S), flow switch (FLS), and control relays furnished by others unless otherwise specified. 4. Items marked with an * are furnished by York International Corporation. 5. Items marked with an ** are available from York International Corporation at additional cost. 6. Control power supply 115V 50/60 Hz, 1.5 KVA capacity for control center only, is supplied by a control power transformer (1T) mounted on the side of the Solid State Starter as shown. It is factory wired. 7. Multiple conduits must contain an equal number of wires from each phase in each conduit to prevent overheating. Use copper conductors only; DO NOT USE aluminum conductors. See Note 8 for factory furnished starter terminal lugs. 8. The following terminal lugs are factory furnished for field wiring connections when a factory-installed disconnect switch is not supplied. All lugs are rated AL9CU. STARTER MODEL WITHOUT DISCONN./ CIRCUIT BREAKER OPTION LINE SIDE LUGS QTY. PER TERMINAL WIRE RANGE GROUNDING LUG WIRE RANGE, QTY. AL9CU SSS 7L 1 #4-600 kcmil #14-1/0, one bbl SSS 14L 2 #2-600 kcmil #14-1/0, two bbl SSS 26L 3 #2-600 kcmil #4-600 kcmil, two bbl or 1/0- SSS 33L 4 #2-600 kcmil 250 kcmil, four bbl The following terminal lugs are factory furnished for field wiring connections when a factory-installed disconnect switch or circuit breaker is supplied. STARTER MODEL NUMBER AND AVAIL- ABLE SWITCH QTY. PER / CIRCUIT TERMINAL BREAKER AMP RATING* LINE SIDE LUGS WIRE RANGE LUG RATING GROUNDING LUG WIRE RANGE, QTY. AL9CU SSS 7L, 250A 1 #6-350 kcmil AL7CU SSS 7L, 400A 2 3/0-250 kcmil AL7CU #14-1/0, 1 bbl SSS 14L, 400A 2 3/0-250 kcmil AL7CU SSS 14L, 600A 2 250-500 kcmil AL9CU #14-1/0, 2bbl SSS 26L, 1200A SSS 33L, 1200A 4 4 4/0-500 kcmil 4/0-500 kcmil AL9CU AL9CU #4-600 kcmil, 2 bbl or 1/0-250 kcmil, 4 bbl *See note 17a 9. Condenser water pump motor starter (3M) holding coil to be furnished for 115V 50/60 Hz. The power requirements for the water pump starter (3M) must be a max. of 1 Amp holding and 10 Amps inrush. If power requirements exceed this value, furnish coil for line voltage, and control relay with 115V coil. 10. Units shipped knocked down require field connection of harnesses to control panel and power wiring between compressor motor and starter. These harnesses and power wiring are furnished by York International Corporation for field assembly and consist of proper lengths of flexible conduit with necessary connectors, and contain the wires (shown in Note 13) properly terminated and marked. 11. Wire #14 AWG copper for one way distance of less than 175 feet. Wire #12 AWG copper for one way distance of more than 175 feet, but less than 300 feet. 12. Wiring diagram for YORK Graphic Control Center, Form 160.80-PW2. Field wiring modifications per Form 160.80-PW5. Wiring diagram for YORK Solid State Starter Form 160.80-PW6. 13. The following interconnecting wires are factory supplied when a YORK Solid State Starter is used. (See Forms 160.80-PW2 and 160.80-PW6. a. Starter to control center L, 2, 16, 24, and 53; 3 and 2 conductor shielded cables. b. Starter to cooling pump 2, 108, GRD. JOHNSON CONTROLS 3

4 14. Full load amperes for 1.5 KVA control power transformer (furnished by York International Corporation and factory wired) to be used with Notes 15, 16 and 17 are: 3-PHASE VOLTAGE HZ CONTROL POWER (1T) TRANSFORMER (AMPS) 200/208 60 7.5 220/230/240 60 6.8 440/460/480 60 3.4 550/575/600 60 2.7 380/400/415 50/60 3.9 15. If an optional circuit breaker is not provided, the branch circuit overcurrent protection device(s) for the YORK Solid State Starter must be a time delay type with a maximum rating which is the smaller of the two values listed below (a) or (b): a. The next standard fuse/breaker rating equal to or below: 2.25 (Compressor-Motor FLA) + Control Transformer Amps b. A rating limited by the starter size as follows: Starter Model No. Max. Fuse/Breaker Size (Amps) SSS 7L 450 SSS 14L 800 SSS 26L 1600 SSS33L 2000 Where 2.25 factor is per 1999 N.E.C. [Paragraphs 440-22(a) and (b)]; FLA is per Note 7; control power transformer Amps per Note 14. 16. The YORK Solid State Starter power wiring ampacity shall be calculated as follows. Model YS minimum circuit ampacity: Ampacity = 1.25 (Compressor-Motor FLA) + Control Transformer Amps Where 125% factor per 1999 N.E.C. (Para. 440-33); FLA is per Note 7; control power transformer Amps per Note 14. 17. If the fused disconnect switch (FDS2) is not located in sight (1999 N.E.C. Para. 440-14) of the YORK Mod B Solid State Starter, a non-fused disconnect switch (not shown) shall be located in sight of the Solid State Starter between FDS2 and the Solid State Starter. The ampere rating shall be determined as follows for the disconnect switch of FDS2: The larger of a. Amp Rating = 1.15 (Compressor-Motor FLA + Control Transformer Amps) or b. The size required to mount the fuses determined in Note 15 (if a fused disconnect is employed). Where 115% factor is per 1999 N.E.C. (Para. 440-12b (2)); FLA is per Note 7 and control power transformer Amps per Note 14. An optional factory mounted and wired disconnect switch or circuit breaker is available within the Mod B SSS (see Note 8). 18. Control circuit wiring for 3M condenser water pump motor starter is shown for cooling only application. 19. The main power transformer should be adequately sized such that the transformer voltage drop does not exceed 10% during unit start-up. Also, the supply voltage, at starter input terminals, during start-up must be maintained above the minimum value specified in the table. Note that while the YORK chiller will perform acceptably during startup with this amount of voltage drop, the performance of other equipment connected to the supply transformer could be adversely affected. THREE PHASE VOLTAGE HZ MINIMUM VOLTAGE AT STARTER INPUT TERMINALS DURING START-UP 200/208 60 170 230/240 60 196 440/460/480 60 391 575/600 60 489 380 50 / 60 323 400 50 340 415 50 353 20. Automatic control of the chilled water pump by the Control Center is shown. Chilled water pump motor starter (5M) holding coil to be furnished for 115V 50/60 Hz. The power requirements for the water pump starter (5M) must be a maximum of 2 Amps inductive at 115VAC. If power requirements exceed this value, furnish coil for line voltage, and control relay with 115V coil. JOHNSON CONTROLS

Two chilled water pump operating modes are available via the CHW Pump programming dip switch (SW1, position 8) on the micro board. With the switch in the OFF position, the chilled water pump operates for 30 seconds prior to compressor start, during compressor operation, coastdown, and LWT cycling shutdowns. With the switch in the ON position, the chilled water pump operates as above plus it operates during MULTI- UNIT and REMOTE/LOCAL cycling shutdowns. For manual chilled water pump control, connect a manual start/stop switch as shown in Detail A. 21. Each 115VAC field-connected inductive load, i.e. relay coil, motor starter coil, etc. shall have a transient suppressor wired (by others) in parallel with its coil, physically located at the coil. Spare transient suppressors are factory supplied in a bag attached to the keypad cable clamp in the Graphic Control Center. 22. The Condenser Flow Switch is optional. If not present, a jumper must be installed between TB4-11 and TB4-1. JOHNSON CONTROLS 5

FIELD CONNECTIONS - SOLID STATE STARTER Figure 1 - FIELD CONNECTIONS - SOLID STATE STARTER 6 JOHNSON CONTROLS

FIELD CONNECTIONS - SOLID STATE STARTER (CONT'D) FORM 160.80-PW4 FIGURE 1 - FIELD CONNECTIONS - SOLID STATE STARTER (CONT'D) JOHNSON CONTROLS 7

P.O. Box 1592, York, Pennsylvania USA 17405-1592 800-861-1001 Subject to change without notice. Printed in USA Copyright by Johnson Controls 2015 www.johnsoncontrols.com ALL RIGHTS RESERVED Form 160.80-PW4 (215) Issue Date: February 4, 2015 Supersedes: 160.80-PW4 (1099)