Premounted Midi Shunts

Similar documents
Premounted Midi Shunts

The valves can be controlled electronically by thermal actuators or act as self-acting units by means of remote temperature adjusters.

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

High Capacity Valve Body, Type RA-G

EL5600 Series Electric Actuators for DN15 to DN100 Valves

Actuator ABNM A V Proportional For Use with RA2000 Valves

ON/OFF zone valves AMZ 112, AMZ 113

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

HERZ Motorised Actuator

TDU.3 floor distribution unit SK

COMPONENTS FOR SOLAR THERMAL SYSTEMS

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

Control valves with electric actuators up to 90 C PN

ON/OFF zone valves AMZ 112, AMZ 113

LK Manifold Shunt VS2

LK Manifold Shunt VS 2-2,5

AEL5 Series Electric Linear Actuators for DN15 to DN100 Control Valves

Pump Stations for Heating Circuits

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

AEL6 Series Smart Electric Actuators for ½" to 4" Control Valves

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

Surface mounting, flush mounting, and DIN track mounting

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

VEP-11/12/21/22 Series

FHF Floor Heating Manifold

EMO TM. Actuators High performance proportional actuator For modulating control

VA-7450 Series. Electric Valve Actuators

SSM Floor Heating Manifold

Actuator type ABNM with Theft Protection, 0-10 V Proportional

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

MAKING MODERN LIVING POSSIBLE. Pressure switch BCP. Technical brochure

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

4-Way Mixing Panel Submittal - Page 1 of 6

underfloor heating PRODUCTS FOR UNDERFLOOR HEATING

Series description: Wilo-Stratos

AEL6 Series Smart Electric Actuators for DN15 to DN100 Control Valves

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Motor types SMV/SMVE for MEV/MRV motorised valves

MAKING MODERN LIVING POSSIBLE INT. Danfoss Link HR Hidden Relay. Installation Manual. Danfoss Heating

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Zone Valves and Parts (Honeywell)

ESBE Series 60 Electronic Motor Actuator (Combined with ESBE 3&4-way rotary valves)

High capacity valve body, type RA-G

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

Control solutions Biofloor

Features. Description. Table of Contents

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Position Count Description Unit price

EX3: stepper motor valve with safety embedded solenoid ON/OFF valve

POW72V35A/BMS CHARGER SPECIFICATION

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

SERIES 1000 ELECTRIC ACTUATORS

NETSIAN TECHNOLOGY VALVE SCHEDULE

Versatile and Rugged Industrial LIthium/LiPO Charger Series

Accessories STRA Room Controller

Installation Instructions: K-Safe-T-Drift

Solenoid coil for control in potentially explosive areas Type BZ

Commercial Actuator Selection Chart Non-Spring Return

MCD Pump Application Module

22C, 22CX, 22CX5, 26LC Series

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

AXS 215S: Continuous actuator for unit valves, with stroke indicator

Control Solutions Biofloor

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Function Relays, Interfaces and Converters

CRNE15-12 A-FGJ-G-V-HQQV 3x HZ

Specification of Battery Charger

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

Digital Room Thermostats with Touch Screen LCD

earth safe Fuel Systems for Critical Power

Solid State Relays, 3-phase

Damper Actuators Non-Spring Return

Top Microsystems Proprietary Specification P/N: A190047LV6 FSM RB VA.1 SPECIFICATION

TA-6-way valve. Standard control valves 6-way valve for change-over systems

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

GWL/ Power Group Technology Solutions Stay Powered for the Future

OPTISWITCH 4000/5000. Vibration level switches for liquids

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Power Supplies. SDN-C Compact DIN Rail Series

Preassembled fixed-point control, distribution and pumping unit for radiant panel heating systems DOMORADIANT Series

VTZ variable speed Reciprocating compressors

J3C-L Nm Smart Electric Valve Actuator Failsafe Function Type: J3C Model: L140-BSR

Products for underfloor heating

PRODUCTS FOR HEATING AND TAP WATER SYSTEMS. Product Catalogue

Ordering Information. Text Surface-Mounting Signal Relay G6K

VPA Series and VAP Actuator

Model Number Structure

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Level switches Series LC40 Float level switch for liquids

Valve monitoring system VDK 200 A S02

INSTALLATION/OPERATING INSTRUCTIONS TSC

CRE10-12 AN-FJ-A-E-HQQE 3x HZ

Electric Expansion Valve Type AKVO 10

Transcription:

Application Midi Shunt 088U0181 - with one circuit Midi Shunt 088U0182 - with two circuits Midi Shunt 088U0183 - with three circuits The Danfoss floor heating midi shunt is a series of pre-mounted shunts for one, two or three heating circuits. It comes pre-mounted with CF2 master controller, manifolds, mixing shunt and actuators in a small and compact solution. Features: Compact design - fits in even the smallest places. Pre-mounted - minimal risk of installation faults. Easy ordering - only one number nessecary. Short installation time. Free choice between four different CF2+ thermostats (ordered separately). Grundfos Alpha 2L pump ensures the lowest possible operating costs. Ordering Midi Shunt version For room size Code no. For 1 circuit, pre-mounted with CF2+ master controller, mixing shunt with Alpha 2L 15-40 circulation pump, manifold/control valve and TWA-A 24V NC actuators For 2 circuits, pre-mounted with CF2+ master controller, mixing shunt with Alpha 2L 15-40 circulation pump, manifold/ control valve and TWA-A 24V NC actuators For 3 circuits, pre-mounted with CF2+ master controller, mixing shunt with Alpha 2L 15-40 circulation pump, manifold/ control valve and TWA-A 24V NC actuators up to 20 m 2 up to 40 m 2 up to 60 m 2 088U0181 088U0182 088U0183 VDIKC102 Danfoss 06/2015 1

Technical specifications Midi Shunt 088U0181 088U0182 088U0183 Number of circuits 1 2 3 Heating area up to 20 m 2 up to 40 m 2 up to 60 m 2 Pump type/capacity Grundfos Alpha 2l 15-40 Temperature controller Room control Actuators FH-TC, self-acting, 15-52 C CF2+ MC5 230V supply / 24 V output TWA-A NC 24 V CF-MC Master Controller CF-MC is the Master Controller in Danfoss CF2+ wireless floor heating control system. CF-MC is connected directly to 230 V power supply, and it provides all actuator outputs with 24 V. Code no. Supply voltage Output voltage 088U0245 230 VAC 24 VDC Number of outputs 5 Transmission frequency Transmission range Transmission power Max. running load of actuator output Max. load for pump relay Max. load for boiler relay Approvals 868.42 MHz up to 30 m (in normal buildings) < 1 mw 35 VA (total for all outputs) 230 V, 8 A / 2 A (inductive) 230 V, 8 A / 2 A (inductive) CE Standard EN 60730 Directives Protection class Length of mains cable Weight R&TTE, LVD, EMC IP30 1.5 m 700 g For further technical information, see specific CF-MC Master Controller data sheet. 2 VDIKC102 Danfoss 06/2015

RA-N Valve / FHF Manifold Midi Shunt 088U0181 has one heating circuit and is equipped with a Danfoss RA-N pre-setting valve. Midi Shunt 088U0182 is equipped with a FHF manifold with two circuits, and Midi Shunt 088U0183 has a three circuit manifold. The FHF manifold is used for controlling water flow in under floor heating systems and consists of a supply and return manifold. The supply manifold includes possibility for individual shut-off of each circuit and. The return manifold is equipped with integrated Danfoss RA-N pre-setting valves securing optimal hydraulic balance in the system. The valves are controlled electronically by TWA thermal actuators. RA-N 15 valve Valve / Manifold RA-N 15 valve FHF-2 manifold FHF-3 manifold FHF-3 manifold Code no. 013G0013 088U0502 088U0503 See specific data sheets for FHF manifolds and RA-N pre-setting valves for further technical information. TWA Thermal Actuator TWA is a small actuator for electrical on/off-control to activate valves and floor heating manifolds. TWA is equipped with a visual position indicator to show the open or closed position of the valve. For Midi Shunts is used the TWA-A 24 V NC (Normally Closed) version. Code no. Supply voltage Max. inrush current Frequency Running power consumption Spindle travel time Ambient temperature 088H3110 24 V 350 ma 50-60 Hz 2 W ~3 min. 0-60 C Enclosure IP 41 Cable length 1200 mm For further technical information, see specific TWA actuator data sheet. VDIKC102 Danfoss 06/2015 3

FH-TC Temperature controller FH-TC is a self-acting thermostatic sensor, used for flow temperature control of floor heating and radiator heating systems. The water temperature is directly measured by a stainless steel immersion sensor. Code no.: 088U0302 Features: Closes on rising sensor temperature. Closes against differential pressure of up to 6 bar. Temperature range: 18-52 C. Designed for pressure PN 10. Temperature setting 1 2 3 4 5 6 max. 20 C 25 C 30 C 35 C 40 C 45 C 52 C Thermostats Room thermostats must be ordered separately. Choose between these models: CF-RS Standard Thermostat Code no.: 088U0210 CF-RP Public Thermostat (tamperproof) Hidden set point adjustment for use in childrens rooms, schools, office buildings etc. Code no.: 088U0211 CF-RD Display Thermostat Digital display showing actual or set room temperature. Code no.: 088U0214 CF-RF Display Thermostat with InfraRed floor sensor Digital display showing actual or set room temperature. InfraRed floor sensor for minimum and maximum floor surface temperature limitation. Code no.: 088U0215 For further technical information, see specific CF-Rx data sheet. 4 VDIKC102 Danfoss 06/2015

Dimensions 325 mm 47 mm 425 mm Midi Shunt 088U0181 165 mm 325 mm 47 mm 425 mm Midi Shunt 088U0182 165 mm 369 mm 47 mm 425 mm Midi Shunt 088U0183 165 mm VDIKC102 Danfoss 06/2015 5

6 VDIKC102 Danfoss 06/2015