Technical details Temperature range Medium + C... +0 C Filtered, oil-free and dried compressed air according to ISO 8-:00, Class ::, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 0 C below lowest occurring ambient temperature. Materials Body: Al (anodized), plastic, seals: NBR, FKM Protection IP 6 according to EN 609 Manifold system with integrated electrical connection including LED indicators. Each station can accommodate two /-way valves or one /- or /-way valve. All connections are accessible from the front. The valves and the multi-pin plug with cable must be ordered separately. The manifold can be mounted with M screws from bottom or from top using the mounting bracket RE-0-B-0 or on a DIN-rail (screws are included). The valve terminal is delivered pre-assembled and function-tested. If not specified with the order, valve configuration is as follows: Valves are mounted according to their order number, starting with high numbers on the side of the multi-pin, ending with low numbers on the opposite side, followed by blind plates (if ordered). Order code Series Number of stations 0 stations 06* 6 stations 08 8 stations 0* 0 stations stations * only for Multi-pin RE-0/**-***-*** Pneumatical connections 00 0 0 060 06 06 at tube connection Ø 8 at tube connection Ø 0 at at tube connection Ø 8 at tube connection Ø 0 at Electrical options M- Multi-pin B B6 Profibus-DP More detailed information about the installation you find in the manual at www.airtec.de. Subject to change 0
Dimensions Multi-pin Bus connection M M 6 6. 8 00. 8 0 + n x 0. + n x 0. 0 0 + n x 0. 0 + n x 0. 0 80 80 G/8 G/8 M 0. M 0. = pressure inlet, = outlets, = exhausts 8,8 = solenoid exhausts n = number of stations 0 Subject to change
Electrical options Multi-pin The 6-pin multi plug (see page -) has to be ordered separately. Pin Function Wire color solenoid white solenoid brown solenoid green solenoid yellow solenoid grey 6 solenoid 6 pink solenoid blue 8 solenoid 8 red 9 solenoid 9 black 0 solenoid 0 violet solenoid grey/ pink solenoid red/ blue solenoid white/ green Pin Function Wire color solenoid brown/ green solenoid white/ yellow 6 solenoid 6 yellow/ brown solenoid white/ grey 8 solenoid 8 grey/ brown 9 solenoid 9 white/ pink 0 solenoid 0 pink/ brown solenoid white/ blue solenoid brown/ blue solenoid white/ red solenoid brown/ red GND white/ black 6 - - Profibus-DP Bus connector Bus In: plug M -pin B-code Bus Out: socket M -pin B-code Power connector plug M -pin A-code Baud rate 9.6 Kbit/s... Mbit/s Voltage V DC ± 0% Power consumption. W Address selection by decimal coded rotary switches. Bus terminal resistance external over Bus Out socket Bus connector Bus In: plug M -pin A-code Bus Out: socket M -pin A-code Power connector plug M -pin A-code Baud rate 0 Kbit/s... Mbit/s Voltage V DC ± 0% Power consumption. W Address selection by decimal coded rotary switches. Bus terminal resistance external over Bus Out socket Subject to change 0
valves > Technical details Outlets Nominal size Temperature range Medium according to the pneumatically connections of the terminal mm + C... +0 C Filtered, oil-free and dried compressed air according to ISO 8-:00, Class ::, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 0 C below lowest occurring ambient temperature. Materials Nominal voltage V DC, ± 0% Power consumption Body: Al (anodized), plastic, seals: NBR, FKM, PU inner parts: Al, stainless steel and brass 0.8 W Protection IP 6 according to EN 609 Electrically operated spool valve. The manual override is non-detent. The manual override is located on top of the terminal cover. x /-way-valves LF-0-0/-HN- x /-way, single solenoid, air spring return, NC LF-0-/-HN- x /-way, single solenoid, air spring return, NO LF-0-/-HN- x /-way, single solenoid, air spring return, x NC, x NO /-way-valves /-way-valves LF-0-0-HN- /-way, single solenoid, air spring return LF-0-0-HN- /-way, center position closed LF-0--HN- /-way, single solenoid, mechanical spring return LF-0--HN- /-way, center position exhausted LF-0-0-HN- /-way, double solenoid LF-0--HN- /-way, center position pressurized Technical data LF-0-0/-HN- LF-0-/-HN- LF-0-/-HN- Operating pressure (bar)...8...8...8 Pilot pressure (bar)...8...8...8 Flow rate (Nl/min) 00 0 00 / 0 (NC / NO) Weight (kg) 0.00 0.00 0.00 0 Subject to change
Valve terminals Valve terminals > valves > Technical data LF-0-0-HN- LF-0--HN- LF-0-0-HN- Operating pressure (bar)...8...8...8 Pilot pressure (bar)...8...8...8 Flow rate (Nl/min) 00 00 00 on: 8 off: 8 off: 0 on: off: Weight (kg) 0.0 0.0 0.0 LF-0-0-HN- LF-0--HN- LF-0--HN- Operating pressure (bar)...8...8...8 Pilot pressure (bar)...8...8...8 Flow rate (Nl/min) 80 80 00 on: 0 off: 0 on: 6 off: 0 on: 6 off: 0 Weight (kg) 0.00 0.00 0.00 Accessories RE-0-DT-0 Pressure dividing plug P-canal 8-ST-0-M-6-xxx 6-pin multi plug, straight RE-0-MS-0 Kit for DIN-rail mounting xxx = 0 xxx = 0 m cable 0 m cable RE-0-B-0 Mounting bracket (pair) 8-ST-RE-6-xx-yy Connector kit xx = 0 in- and output xx = 0 with termination resistance Blind plate RE-0-V-EP yy = B yy = B6 Profibus RE-0-P-0 Device for additional air supply Subject to change 0