LV Capacitor Bank APC

Similar documents
LV Capacitor Bank APC

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction

DYNACOMP. The top-class reactive power compensator

LV Capacitor CLMD Reliability for Power Factor Correction

CLMD Low-voltage capacitors for reliable power factor correction

LV Capacitor CLMD03 Power Module Instruction manual

MODVAR Low voltage reactive power compensation modules Installation manual

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Dynacomp The Top-Class Dynamic Response Compensator

Power Factor Correction Capacitors Type LKT

System pro E power Capacitor Bank

High Reliable Components for Power Factor Correction and Power Quality

Power Factor Correction Equipment

&MFDUSJGJDBUJPO Products 1PXFS 2VBMJUZ 'JMUFST 12'* o 12'. o 12'4 )BSNPOJDT NJUJHBUJPO MPBE CBMBODJOH BOE SFBDUJWF DPNQFOTBUJPO PO -7 OFUXPSLT

PhiCap Capacitors for Power Factor Correction

CLASS 5870 ReactiVar Power Factor Capacitors AT6000/AT7000 Transient Free Reactive Compensation

Automatic COSYS PFC. Automatic power factor correction system NEW

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

CP Automatic capacitor bank

High Reliable Components for Power Factor Correction and Power Quality

Power Factor Correction

Power Factor Correction Capacitors in sheet steel cases

C1000 Series Automatic Cap Bank

Three Phase Capacitors KNK

ARTECHE LOW VOLTAGE CAPACITOR BANKS. smartbat LV.

Power System Solutions (PSS)

Power Factor Correction - UPS - Stabilizers - AC / DC Power Supply Units

Film Capacitors Power Factor Correction

multicond Power capacitors Data sheet: multicond

Film Capacitors Power Factor Correction

POWER CAPACITORS. Cylindrical capacitor standard duty

FINHRM FINHRM5 FINHRMA FINHRMAC

LV Capacitors QCap-L series Capacitors for power factor correction

PQstorI One stop solution for energy storage and power quality

AC Capacitors Safety and Application Manual

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

EMPAC Metal enclosed capacitor bank for wind applications

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

Automatic capacitor banks

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department

Power factor correction Harmonic filtering Dynamic flicker compensation

Smart Energy & Power Quality Solutions. Main catalogue 2012/2013. Power Factor Correction / Power quality

Power Factor Correction Capacitors Type LKT

CTU 02. Thyristor switching module for fast PF compensation. User manual

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

ahead of time Voltage Stabilisers

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

ABB n.v Power Quality in LV installations

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Easy Choice for Energy Efficiency

PRODUCT CATALOGUE 2016

HV Compensation & Filtering Products

Power Factor Correction Capacitors Type LKT

MGE TM Galaxy TM 7000 GFC

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

PowerWave 33 Efficient power protection for today s IT and process-related work environments

AIR CORE REACTORS. Phoenix Electric Corporation

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Index Low Voltage Network Quality. Low Voltage Network Quality

TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 140 Kvar

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

AGroup brand POWER FACTOR CORRECTION AND CONTROL OF ELECTRICAL NETWORK QUALITY INTERNATIONAL VERSION

VarSet Brochure and Catalog

Industrial PFC UPS System

Power IT LV Active Filters PQFI - PQFM PQFK - PQFS

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Power Factor Correction

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Power Factor Correction Capacitors Type LKT

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Reactive Energy Management

MADE IN GERMANY. Components for reactive power compensation. Components for reactive power compensation. Power Quality. Reactive power controllers

ORION PLUS three-phase kVA

- Soft resin impregnated Stacked winding Tripple Safety System

PQdynaC High speed, flexibility and modularity

INSTRUCTION MANUAL (M A)

HARMONIC FILTER REACTOR

PhaseCap HD Capacitors for Power Factor Correction

AF series contactors (9 2650)

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

SINAMICS GM150 IGCT version

PQC - STATCON The ultra fast Power Quality Compensator

PowerValue 11/31 T kva

PQactiF Higher flexibility and modularity for improved power quality

MGE TM Galaxy TM 7000

R.4. Automatic capacitor banks with static system. Power factor correction and harmonic filtering. Homepage :

Simple and smart power factor correction

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

FRANKE. Power Factor Correction GMKP ENERGY. GMKPg Low Voltage Capacitors by Gas Technology Save energy and reduce carbon dioxide emission!

Low Voltage Power Factor Corrections

Transcription:

LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks

The ABB comprehensive solution for automatic power factor correction The APC is a powerful and compact automatic bank. It is very easy to install and to operate. It provides a high level of reliability and security. APCL and APCM: standard and reinforced ranges APCL2 box of 125kvar (master unit) Fan RVC Controller Contactors HRC Fuses Protection against direct contact Ample space for wiring LVCS Capacitors Slave unit Bottom cable entry Master unit APCM2 cubicle of 400kvar (master unit) Lifting lugs Fans Contactors HRC Fuses Busbar RVC Controller LVCS capacitors Bottom cable entry Slave unit Plinth Master unit

APCR: de-tuned range - with reactors APCR cubicle of 300kvar (master unit) Lifting lugs Fans Contactors HRC Fuses RVC Controller Busbar LVCS Capacitors modules Reactors modules Bottom cable entry Plinth Slave unit Master unit Powerful and compact ABB capacitors and a specially designed ventilation system allow the APC to reach a maximum reactive power within a minimum volume. Easy to select The APC exists in 5 versions: 2 types of boxes (APCL1 and APCL2) and 3 types of cubicles (APCM1, APCM2 and APCR). The APC offers a power range from 25 to 800kvar (in different configurations). For the APCL2, APCM2 and APCR types, slave units are available for extension up to 250kvar in APCL2, 800kvar in APCM2 and 600kvar in APCR (1 master unit + 1 slave unit). Easy to install The APC is a complete unit, factory tested and ready for connection. Its commissioning may be completely automatic. There is ample space for wiring. The APCL box is equipped with wall mounting brackets. The APCM and APCR cubicles are equipped with a plinth and lifting lugs for easy handling. Slave units (APCL2, APCM2 & APCR) are equipped with an interconnection cable for fast connection to the master unit. Easy to use The multiple automatic functions of the RVC and its user-friendly interface make the APC very easy to operate. 3

Reliable and safe The reliability of the APC is based on a set of ABB components specially designed for the reactive power compensation application. The APC has an IP23D protection level (closed door) and is protected against direct and accidental contact (open door). ABB capacitors The dielectric of the capacitors windings is made of in-house metallized polypropylene film giving exceptional properties: high voltage withstand capability. excellent peak current handling capacity. high capacitance stability. long life even under high electrical stress. very low losses. exceptional self-healing properties. LVCS capacitors The LVCS protection system offers a reliable and safe protection. It is based on: the instant reaction of state of the art overpressure detection and disconnection devices. a double casing insulation protecting the windings from the environment and assuring a high capacitance stability over the whole capacitor service life. The LVCS is suitable for maximum ambient temperature of +55 C (class D) and minimum of -25 C. The LVCS reinforced range is rated at 474V. LVCS Contactor-type terminals Built-in safety discharge resistor (<50V in 1 min) Dry type self-healing capacitor winding Thermo-setting resin Insulating enclosure Overpressure sensitive disconnector ABB Contactors Contactors have been specially selected for their excellent endurance tests handling capability. 4

RVC PF Controller The RVC is not affected by the harmonics. The RVC complies with EU directives for EMC for operation at 50Hz and bears the CE marking to this effect. The RVC is suitable for hot environments thanks to its maximum ambient temperature of 60 C. The RVC is fitted with an overvoltage / undervoltage protection and protections against harmonic distortion (THDV). RVC LCD display with indication of: inductive/capacitive PF active outputs demand for switching on/off a capacitor step alarm conditions overtemperature condition capacitor disconnection key parameters : voltage, current, power factor, THDV and THDI Keypad Automatic setting of: phase shift C/k switching delay number of outputs type of switching sequence Easy commissioning with automatic recognition of: special connections (single-phase, CT leads) number of outputs type of switching sequence Automatic/manual mode ABB Reactors (for APCR execution) The dry type resin embedded reactors are specially designed to suit the reactive power compensation application. Their exceptional linearity and thermal stress resistance characteristics ensure a high reliability degree even in case of temporary overvoltage. Ventilation Except for the APCL1 type, all APCs are equipped with a ventilation system specially selected for its long life duration. The APC ventilation system consists of fans with temperature-dependent speed control and temperature probes which provide the fans with the necessary thermal data. These fans adapt their speed to the actual cooling requirements of the APC. In case of temporary overheating, the APC is automatically disconnected. Environment friendly The ISO 14001 certification guarantees our commitment to the environment. 5

Options Main circuit-breaker. Top cable entry (for APCM1, APCM2 and APCR only). RVT controller (for APCM1, APCM2 and APCR only). RVT Modbus For a maximum protection of your capacitor bank against temporary deterioration of your network quality. While having all the functions of the RVC, the RVT also has features including: programmable protection thresholds (undervoltage, overtemperature, excessive harmonic distortion, etc ). The RVT protects your capacitor bank. It is recommended for installation where overvoltage, resonance or overtemperature is likely to happen. full graphics display. guided navigation and programming. network information and bank monitoring (voltage, current, harmonics spectrum, etc...) RS-485 Modbus adapter allowing communication with a monitoring system. All RVT parameters are remotely accessible (including harmonic spectra and tables.) multi-language support. help button giving instant access to a description of all RVT features and functionality. printer connection. input contacts for day/night cos ϕ and external alarm. output contacts for alarm and fan relays. (for further information on the RVT controller, please refer to our specific documentation) Wiring diagram T1 CT LOADS C1...C12 capacitor steps F1 F1 main fuses or protective devices F2 control fuses F3...F14capacitor step fuses K1...K12 contactors P1 PF controller T1 power transformer S Fan DC supply P1 F2 F3-F14 R1-R12 * CT current transformer V1 regulated speed fan * R1...R12 reactors (APCR only) S K1-K12 V1 C1-C12 6

Technical specifications Nominal voltage and frequency: 230, 400V - 50Hz (standard range). 240, 480V - 60Hz (standard range). 400V - 50Hz (reinforced range rated at 474V). 400, 415, 525, 690V - 50Hz (de-tuned capacitor bank) 240, 380, 480, 600V - 60Hz (de-tuned capacitor bank) Connection: Three phase. Configuration: APCL1 & APCM1: master unit only. APCL2, APCM2 & APCR: master and slave units. Slave units are not equipped with PF controller but are fitted with an interconnection cable. Power factor setting: From 0.7 inductive to 0.7 capacitive. Starting current setting (C/k): From 0.01A to 3A for the RVC controller. From 0.01A to 5A for the RVT controller (optional for the APCM1, APCM2 and APCR). Operation: Automatic or manual setting of the controller with indication of : - the number of active outputs. - the inductive or capacitive power factor. - alarm conditions. - overtemperature. - demand for switching on/off a capacitor step. - voltage, current, THDV and THDI Threshold setting for protection against overvoltage, undervoltage and high THDV. Losses: Dielectric losses: less than 0.2 Watt/kvar. Capacitor total losses: less than 0.5 Watt/kvar (discharge resistors included). Automatic bank total losses at 400V 50Hz: - without reactors: less than 1.5 Watt/kvar (including accessories losses), - with reactors: less than 5.5 Watt/kvar (including accessories losses). Capacitors: Dry type self healing according to IEC 60831-1&2. Voltage test: 2.15 Un between terminals during 10 sec at rated frequency (above IEC 60831-1&2). Acceptable overloads: - overvoltage tolerance: 10% max. intermittently. - overcurrent tolerance: 30% permanently. Temperature range: -25 C / class D according to IEC 60831-1&2. Reactors (APCR only): - Type : dry type resin embedded according to IEC 289, IEC 76 - Maximal harmonic voltage distortion: U 3 /U 1 = 0.5 % U 5 /U 1 = 6.0 % U 7 /U 1 = 5.0 % U 11 /U 1 = 3.5 % U 13 /U 1 = 3.0 % (not exceeding a THDU of 8 %). The automatic capacitor bank complies with EN 61921. Automatic capacitor bank tests: - Insulation test. - Functional test. CE Marked. Protection: IP23D (closed door). Protected against direct and accidental contact (open door). Execution: Indoor. Color: Beige RAL 7032. Ambient temperature: -5 C/+40 C according to EN 61921. Ventilation: - Natural for the APCL1. - Forced for the APCL2, APCM1, APCM2 and APCR (temperature-dependent speed controlled fans). Installation: Box: - Wall mounting (fixation brackets included). - Bottom cable entry. Cubicle: - Floor fixation. - Equipped with a plinth. - Lifting lugs provided. - Top or bottom cable entry. Slave units have to be connected to the master unit. Important notice: The installation of capacitors on networks disturbed by harmonics may require special precautions especially when there is a risk of resonance. 7

APCL1, APCL2, APCM1 and APCM2 Range Standard range 230V 50Hz - Clean network Type Power Regulation Optional main (kvar) at 230V x*kvar circuit-breaker APCL1 25 4*6.25 T1N160FFC 37.5 3*12.5 T1N160FFC APCL2 50.0 4*12.5 T3N250FF 62.5 5*12.5 T4N320FF (1) 100 8*12.5 T3N250FF (1) 125 10*12.5 T4N320FF APCM1 75 6*12.5 T4N320FF 87.5 7*12.5 T5N630FF 100 8*12.5 T5N630FF APCM2 112.5 9*12.5 T5N630FF 125 5*25 T5N630FF 150 6*25 T5N630FF 175 7*25 S6N800F 3P F 200 8*25 S6N800F 3P F (1) 250 10*25 T5N630FF (1) 300 12*25 T5N630FF (1) 400 16*25 S6N800F 3P F Standard range 400V 50Hz - Clean network Type Power Regulation Optional main (kvar) at 400V x*kvar circuit-breaker APCL1 25 2*12.5 T1N160FFC 37.5 3*12.5 T1N160FFC 50 4*12.5 T1N160FFC 62.5 5*12.5 T1N160FFC 75 3*25 T3N250FF APCL2 87.5 7*12.5 T3N250FF 100 4*25 T3N250FF 125 5*25 T4N320FF (1) 200 8*25 T3N250FF (1) 250 10*25 T4N320FF APCM1 150 6*25 T5N630FF 175 7*25 T5N630FF 200 8*25 T5N630FF APCM2 225 9*25 T5N630FF 300 6*50 S6N800F 3P F 350 7*50 S6N800F 3P F 400 8*50 S7S1250F 3P F (1) 450 9*50 T5N630FF (1) 600 12*50 S6N800F 3P F (1) 700 14*50 S6N800F 3P F (1) 800 16*50 S7S1250F 3P F Reinforced range (capacitor rated at 474V) 400V 50Hz - Slightly polluted network Type Power Regulation Optional main (kvar) at 400V x*kvar circuit-breaker APCL1 20 2*10 T1N160FFC 30 3*10 T1N160FFC 40 4*10 T1N160FFC 50 5*10 T1N160FFC 60 3*20 T1N160FFC APCL2 70 7*10 T3N250FF 80 4*20 T3N250FF 100 5*20 T3N250FF APCM1 120 6*20 T4N320FF 140 7*20 T5N630FF 160 8*20 T5N630FF APCM2 180 9*20 T5N630FF 200 5*40 T5N630FF 240 6*40 T5N630FF 280 7*40 S6N800F 3P F 320 8*40 S6N800F 3P F Standard range 240V 60Hz - Clean network Type Power Regulation Optional main (kvar) at 240V x*kvar circuit-breaker APCM1 75 6*12.5 T4N320FF 87.5 7*12.5 T5N630FF 100 8*12.5 T5N630FF APCM2 112.5 9*12.5 T5N630FF 125 5*25 T5N630FF 150 6*25 T5N630FF 175 7*25 S6N800F 3P F 200 8*25 S6N800F 3P F (1) 250 10*25 T5N630FF (1) 300 12*25 T5N630FF (1) 400 16*25 S6N800F 3P F Standard range 480V 60Hz - Clean network Type Power Regulation Optional main (kvar) at 480V x*kvar circuit-breaker APCM1 150 6*25 T4N320FF 175 7*25 T5N630FF 200 8*25 T5N630FF APCM2 225 9*25 T5N630FF 300 6*50 T5N630FF 350 7*50 S6N800F 3P F 400 8*50 S6N800F 3P F (1) 450 9*50 T5N630FF (1) 600 12*50 T5N630FF (1) 700 14*50 S6N800F 3P F (1) 800 16*50 S6N800F 3P F (1): 1 master unit + 1 slave unit. Slave units are available for extension. Only master and slave units of the same type can work together (APCL2 master with APCL2 slave, APCM2 master with APCM2 slave and APCR master with APCR slave). For compatibility between master unit and slave unit, please check with your local ABB agent that the total (master + slave) switching sequence (1:1:2:2:..., 1:2:4:4:..., etc) is recognized by the PF controller. 8

APCR Range 400V 50Hz - Polluted network (kvar) at 400V x*kvar circuit-breaker 5.67-7 - 12.5 100 4*25 T3N250FF 1255*25 T4N320FF 150 3*50 T5N630FF 150 6*25 T5N630FF 1757*25 T5N630FF 200 4*50 T5N630FF 200 8*25T5N630FF 300 6*50 S6N800F 3P F (1) 350 7*50 T5N630FF (1) 400 8*50 T5N630FF (1) 450 9*50 T5N630FF (1) 600 12*50 S6N800F 3P F 415V 50Hz - Polluted network (kvar) at 415V x*kvar circuit-breaker 5.67-7 - 12.5 100 4*25 T3N250FF 1255*25 T4N320FF 150 3*50 T5N630FF 150 6*25 T5N630FF 1757*25 T5N630FF 200 4*50 T5N630FF 200 8*25T5N630FF 300 6*50 S6N800F 3P F (1) 350 7*50 T5N630FF (1) 400 8*50 T5N630FF (1) 450 9*50 T5N630FF (1) 600 12*50 S6N800F 3P F 525V 50Hz - Polluted network (kvar) at 525V x*kvar circuit-breaker 5.67-7 - 12.5 100 4*25 T3N250FF 5.67-7 - 12.5 125 5*25 T3N250FF 5.67-7 150 3*50 T4N320FF 5.67-7 - 12.5 150 6*25 T4N320FF 5.67-7 175 7*25 T4N320FF 5.67-7 200 4*50 T5N630FF 5.67-7 200 8*25 T5N630FF 12.5 (1) 200 8*25T3N250FF 5.67-7 12.5 (1) 250 10*25 T3N250FF 5.67-7 300 6*50 T5N630FF 12.5 (1) 300 12*25T4N320FF 5.67-7 (1) 350 7*50 T5N630FF (2) T4N320FF (3) 5.67-7 (1) 400 8*50 T5N630FF 5.67-7 (1) 450 9*50 T5N630FF 5.67-7 5.67-7 (1) 600 12*50 T5N630FF 690V 50Hz - Polluted network (kvar) at 690V x*kvar circuit-breaker 5.67-7 - 12.5 100 4*25 T1N160FFC 1255*25 T3N250FF 150 3*50 T3N250FF 150 6*25 T3N250FF 1757*25 T3N250FF 200 4*50 T4N320FF 200 8*25T4N320FF 300 6*50 T5N630FF (1) 350 7*50 T4N320FF (2) T3N250FF (3) (1) 400 8*50 T4N320FF (1) 450 9*50 T5N630FF (2) T4N320FF (3) (1) 600 12*50 T5N630FF (1): 1 master unit + 1 slave unit. (2): Circuit breaker for master unit. (3): Circuit breaker for slave unit. Slave units are available for extension. Only master and slave units of the same type can work together (APCL2 master with APCL2 slave, APCM2 master with APCM2 slave and APCR master with APCR slave). For compatibility between master unit and slave unit, please check with your local ABB agent that the total (master + slave) switching sequence (1:1:2:2:..., 1:2:4:4:..., etc) is recognized by the PF controller. 9

APCR Range 240V 60Hz - Polluted network (kvar) at 240V x*kvar circuit-breaker 6-7 - 12.5 100 4*25 T5N630FF 125 5*25 T5N630FF 150 6*25 T5N630FF (1) 200 8*25 T5N630FF (1) 250 10*25 T5N630FF (1) 300 12*25 T5N630FF 380V 60Hz - Polluted network (kvar) at 380V x*kvar circuit-breaker 6-7 - 12.5 100 4*25 T4N320FF 125 5*25 T4N320FF 150 3*50 T5N630FF 150 6*25 T5N630FF 175 7*25 T5N630FF 200 4*50 T5N630FF 200 8*25 T5N630FF 250 5*50 S6N800F 3P F 300 6*50 S6N800F 3P F (1) 350 7*50 T5N630FF (1) 400 8*50 T5N630FF (1) 450 9*50 S6N800F 3P F (2) T5N630FF (3) (1) 500 10*50 S6N800F 3P F (1) 600 12*50 S6N800F 3P F 480V 60Hz - Polluted network (kvar) at 480V x*kvar circuit-breaker 6-7 - 12.5 100 4*25 T3N250FF 125 5*25 T3N250FF 150 3*50 T4N320FF 150 6*25 T4N320FF 175 7*25 T5N630FF 200 4*50 T5N630FF 200 8*25 T5N630FF 300 6*50 T5N630FF (1) 350 7*50 T5N630FF (2) T4N320FF (3) (1) 400 8*50 T5N630FF (1) 450 9*50 T5N630FF (1) 600 12*50 T5N630FF 600V 60Hz - Polluted network (kvar) at 600V x*kvar circuit-breaker 6-7 - 12.5 100 4*25 T1N160FFC 125 5*25 T3N250FF 150 3*50 T3N250FF 150 6*25 T3N250FF 175 7*25 T4N320FF 200 4*50 T4N320FF 200 8*25 T4N320FF 300 6*50 T5N630FF (1) 350 7*50 T4N320FF (2) T3N250FF (3) (1) 400 8*50 T5N630FF (1) 450 9*50 T5N630FF (2) T4N320FF (3) (1) 600 12*50 T5N630FF (1): 1 master unit + 1 slave unit. (2): Circuit breaker for master unit. (3): Circuit breaker for slave unit. Slave units are available for extension. Only master and slave units of the same type can work together (APCL2 master with APCL2 slave, APCM2 master with APCM2 slave and APCR master with APCR slave). For compatibility between master unit and slave unit, please check with your local ABB agent that the total (master + slave) switching sequence (1:1:2:2:..., 1:2:4:4:..., etc) is recognized by the PF controller. 10

Dimensions Overall dimensions H (mm) W (mm) D (mm) Maximum weight APCL1 550 450 275 26 kg APCL2 750 550 275 42 kg APCM1 1350 600 400 100 kg APCM2 1950 600 400 175 kg APCR 2000 600 550 500 kg 550 275 ( * ) 600 400 450 275 ( * ) 100 APCL1 APCL2 APCM1 600 400 600 550 100 100 1950 1900 2000 1950 550 750 1350 1300 100 APCM2 100 APCR * thickness of the air grid (25 mm) not included 11

Capacitor bank selection The installation of capacitors on network disturbed by harmonics may require special precautions especially when there is a risk of resonance. Feel free to consult your local ABB agent for a proper selection of your APC LV Capacitor Bank. Network Study Our LVNQ specialists will, on request, perform a harmonic study of your network in order to propose you a reactive power compensation solution that prevents any risk of resonance, for maximum reliability. www.abb.com/lowvoltage While all care has been taken to ensure that the information contained in this publication is correct, no responsibility can be accepted for any inaccuracy. We reserve the right to alter or modify the information contained herein at any time in the light of technical or other developments. Technical specifications are valid under normal operating conditions only. We do not accept any responsibility for any misuse of the product and cannot be held liable for indirect or consequential damages. 2GCS301015A0040