MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Similar documents
Modular contactor for installation into distribution boards

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Modular Contactors and Switches D681E121

W Datasheet: DIN Rail Contactors, series AMPARO

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

For Info: Phone: Fax:

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Modular contactors and relays

Installation Contactors RIC, RAC

CI-TI Contactors and motor starters Types CI 61 - CI 98

BETA Switching Switching Devices

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

CI-TI Contactors and Motor Starters Type CI 6-50

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Industrial Contactors CTX 3 3P 185A - 800A

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

D509E. Manual Motor - Starters

Micro Contactor MA Series

Industrial contactors CTX-1

Mini Contactors CI 4-

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Contactor Types CI 61-98

4 - Miniature controls

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Components for EEx e Panels

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Mini Contactors. Technical Catalogue. Type B6, B7 ABB

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

Command and signalling E 250, E 259 selection table

Controls. CONTACTORS CWB Line (up to 40A)

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Modular contactors, type CR

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

AF series contactors (9 2650)

General Catalogue. Quality made in D946E173

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

AF series contactors (9 2650)

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Application Mini Contactors for Motors and Resistive Loads

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

Index. Page. General 4 Approvals 5 Technical Information 9 Mounting Information 10

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

MS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78

3VU13, 3VU16 Circuit-Breakers

Technical data. Miniature Circuit Breakers. System pro M. System pro M

MS25, MST25, MS20, MST20

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Technical Information

Miniature Circuit-Breakers (MCBs)

Essential equipment for all your requirements

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Special Purpose Fuses

CONTACTOR, AC KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION. General details: Main circuit: Product brand name. Size of the contactor

Switchgear for Luminaires

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

Electronic Ballast EVG 2000-T

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A

Application Mini Contactors for Motors and Resistive Loads

MS General Information Extended Product Type: MS

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

Quick selection table

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Table of HS lamps. High-pressure sodium lamps (HS) 35 to 1000 W Lamp Power. Current Manufac. Designation Base

Phase + Neutral, neutral on right side

CB to 1000 A. 1 to 4 single pin main poles with silver pad contacts.

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Thermal Circuit Breaker 3120-F...

Miniature Circuit-Breakers (MCBs)

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

and Refrigeration Institute). CNX Special Purpose Contactors

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Protection components

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Phase + Neutral, neutral on left side

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

ASL09..S 3-pole Contactors - Spring Terminals

Capacitor Switching Contactors Type K3...-A, K3...-K

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

BETA Switching Switches and Light Indicators

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Transcription:

MODULAR DEVICES The range of two, three and four pole isolator switches are of a modular design and fit on DIN 50022 rail. Terminal capacity is 25mm 2. Isolator Switches Rating Poles Modules Reference 100A 2 2 ISOL2/100 125A 2 2 ISOL2/125 100A 3 3 ISOL3/100 100A 4 4 ISOL4/100 125A 4 4 ISOL4/125 DIN-rail mounted modular transformers with 8,12 or 24V outputs. Generally used as bell transformers, but the RK24 is suitable to power the DFA2 remote actuator. (page 15.) Low Voltage (Bell) Transformers Voltage Amps Modules Reference 8V 1 2 RK81 4/8/12V 2/2/1.5 2 RK12 8/12/24V 2/1.3/0.6 2 RK24 The UNO time switch controls electrical appliances according to a 24-hour or 7-day programme. Programming is so simple that it can be carried out by the layman. The time switch can be mounted in a distribution box equipped with 35mm DIN-rails. Time Switches (electromechanical) Max. Load Switching Resistive Inductive Reserve Modules Reference 24 hour 16A 4A No 1 TS UNO-D 24 hour 16A 4A Yes 1 TS UNO-QRD 7 Day 16A 4A Yes 1 TS UNO-QRS The DATA MICRO electronic time switch has adjustable on/off pulses between 1 to 59s long. Current time and date as well as Summer/Winter change-over times are preset at the factory. There are 32 or 64 storage locations depending on the model. It can be mounted in a distribution box equipped with 35mm DIN-rails. Time Switches (electronic with power reserve) Max. Load Storage Switching Resistive Inductive Locations Modules Reference 24 hour & 7 Day 16A 10A 32 2 TS DMICRO+ 24 hour & 7 Day 16A 10A 64 2 TS DMICRO2+ sales@doepke.co.uk 21

MODULAR DEVICES (CONTINUED) Our contactor ratings have been designed for AC1 loads of 20amps, 40amps and 63amps. The 25, 40 & 63A products can be used in AC3 applications see page 44 for appropriate ratings. Voltage Amps Module Contacts Reference 230 20 1 2 x normally open HS20-20 230 20 1 1 x NO, 1 x NC HS20-11 230 20 1 2 x normally closed HS20-02 230 25 2 4 x normally open HS25-40 230 40 3 4 x normally open HS40-40 230 40 3 4 x normally closed HS40-04 230 40 3 3 x NO, 1 x NC HS40-31 230 63 3 4 x normally open HS63-40 230 63 3 3 x NO, 1 x NC HS63-31 Capable of switching loads of 3700W this adjustable twilight switch has an outstanding record of reliability. The unit has an LED status indicator and is capable of adjustment between 5 to 200 LUX. Wall Mounting Twilight Switch Amps Switching Capacity Reference 16 3700W DASY16 Note: 200 LUX is suitable fo light controls only. For other applications requireing higher LUX values please contact the sales office for information. 22 www.doepke.co.uk

Isolator Switches Dimensions and Contact Assignments Rated voltage 230 / 400 V ~ Rated current 100A & 125A Breaking capacity 1,25xI n ; 1,1 x U n ; cos = 0,6 Enclosure protection conforming to DIN VDE 0106 Part 100 Short curcuit resistance 10 ka Terminal cross-section 1,5 to 25mm2 1,5 to 35mm2 Mounting quick-snap to DIN EN 50022 rail Bell Transformers Dimensions Contact Assignments Primary voltage 230 V ~, 50 Hz Duty cycle 100 % continuous duty Housing grey RAL 7035 Weight 240 to 375g according to type Enclosure protection type IP 20 Mark of conformity EN 61558 Time Switches Dimensions 40 www.doepke.co.uk

as per IEC 947-4-1, IEC 947-5-1, VDE 0660, EN 60947-4-1, EN 60947-5-1 Version HS20 HS25 HS40 HS63 Mainswitching elements Rated insulation voltage U i V~ 440 2) 440 2) 440 2) 440 2) Rated operating voltage U e V~ 440 440 440 440 Permiss. number of switch operations AC1, AC3 1/h 300 300 600 600 Mech. service life S x 10 6 1 1 1 1 Utilization catergory AC1 Rated operating current I e (=l th ) open at 60 0 C A 20 25 40 63 Service life, switching S x 10 6 0.1 0.1 0.1 0.1 Lowest switching voltage V/mA 24/100 24/100 24/100 24/100 Transient current strength 10s current A 72 72 216 240 Dissipated energy per pole at I e /AC1 W 2 2 3 7 Utilization category AC3 Switching of 3-phase AC motors Rated operating current I e (=l th ) open at 60 0 C A - 9 27 30 Rating of 3-phase AC motors 220V kw - 2.2 7.5 8.0 50-60 Hz 230-240 V kw - 2.5 8.0 8.5 380-415 V kw - 4 12.5 15 Service life of contact maker S x 10 6-0.15 0.15 0.15 Capacity of trip coils AC operated Energizing V A 7-9 20-25 33-45 33-45 Holding V A 2.2-4.2 4-6 7 7 Operating range of trip coils in multiples of U s (-40 0 C to +40 0 C) 0.85-1.1 0.85-1.1 0.85-1.1 0.85-1.1 Short circuit protection max. rated current of fuse coordination type 1 gl(gg) A 35 35 63 80 Switching times at control voltage U s ± 10% closing delay ms 7-16 9-15 11-15 11-15 openingdelay ms 6-12 4-8 6-13 6-13 arc duration ms 10-15 10-15 10-15 10-15 Auxiliary switching elements Design insulation voltage U i V ~ Main contacts may be used as auxiliary contacts 440 2) 440 2) Thermal rated current - l th 40 0 C A 16 16 60 0 C A 12 12 Utilization category AC15 Design operating 220-240 V A 12 12 current I e 380-415 V A 4 4 440 V A 4 4 Utilization category DC 13 Design operating 24-60 V A 8 8 current I e 110 V A 1 1 220 V A 0,1 0,1 Short circuit protection max. rated current of fuses 1 ka short circuit current, without the contact s fusing together gl(gg) A 25 25 2) applies to systems with earthed neutral, overvoltage categories I to III, contamination level 3 (industrial standard): U imp =4 kw 42 www.doepke.co.uk

TECHNICAL SPECIFICATIONS Dimensions Switching of Lamp Loads Type of Lamp Power Current Capacitor W A µf HS20 HS25 HS40 HS63 Incandescent lamps 60 0.27-22 28 92 129 100 0.45-13 17 55 77 200 0.91-7 8 27 38 300 1.36-4 5 19 26 500 2.27-3 3 11 16 1000 4.5-1 1 6 8 Fluorescent lamps 11 0.16-60 75 210 310 uncompensated or 18 0.37 2.7 25 30 90 140 series compensated 24 0.35 2.5 25 30 90 140 36 0.43 3.4 20 25 70 140 58 0.67 5.3 13 16 40 65 65 0.67 5.3 13 16 40 65 85 0.80-11 14 35 60 Fluorescent lamps 11 0.07-2 x 100 2 x 110 2 x 220 2 x 250 load-lag circuit 18 0.11-2 x 50 2 x 55 2 x 130 2 x 200 24 0.14-2 x 40 2 x 44 2 x 110 2 x 160 36 0.22-2 x 30 2 x 33 2 x 70 2 x 100 58 0.35-2 x 20 2 x 22 2 x 45 2 x 70 65 0.35-2 x 15 2 x 16 2 x 40 2 x 60 85 0.47-2 x 10 2 x 11 2 x 30 2 x 40 Fluorescent lamps 11 0.16 2.0 30 30 67 107 parallel compensated 18 0.37 2.0 20 20 50 80 24 0.35 3.0 15 15 50 80 36 0.43 4.0 10 10 50 80 58 0.67 7.0 6 6 36 46 65 0.67 7.0 5 5 36 46 85 0.8 8.0 4 4 33 44 Fluorescent lamps 18 0.09-40 40 100 150 with electronic ballast 36 0.32-20 20 50 75 58 0.25-15 15 30 55 2 x 18 0.17-2 x 20 2 x 20 2 x 50 2 x 60 2 x 36 0.32-2 x 10 2 x 10 2 x 25 2 x 30 2 x 58 0.49-2 x 7 2 x 7 2 x 15 2 x 20 High-pressure mercury 50 0.61-16 18 38 55 vapour lamps 80 0.80-12 14 28 40 uncompensated 125 1.15-8 9 20 28 eg. HQL, HPL 250 2.15-4 5 11 15 400 3.25-3 4 7 10 700 5.40-1 2 4 6 1000 7.50-1 1 3 4 High-pressure mercury 50 0.28 7 7 7 36 50 vapour lamps 80 0.41 8 5 5 31 44 compensated 125 0.65 10 3 3 25 35 eg. HQL, HPL 250 1.22 18 2 2 14 19 400 1.95 25 1 1 10 14 700 3.45 45 1 1 6 8 1000 4.8 60 - - 4 6 sales@doepke.co.uk 43

Typical Contact Assignments Switching Lamp Loads Type of Lamp Power Current Capacitor W A µf HS20 HS25 HS40 HS63 Transformers 20 - - 40 52 110 174 for halogen 50 - - 20 24 50 80 low-voltage lamps 75 - - 13 16 35 54 100 - - 10 12 27 43 150 - - 7 9 19 29 200 - - 5 5 14 23 300 - - 3 4 9 14 Metal halide lamps 35 0.53-22 24 57 65 uncompensated 70 1-12 14 30 35 e.g. HQI, HPI, CDM 150 1.8-6 8 17 18 250 3-4 5 10 12 400 3.5-3 4 8 10 1000 9.5-1 1 3 4 2000 16.5 - - - 2 2 400 V per pole 2000 10.5 - - - 2 2 3500 18 - - - 1 1 Metal halide lamps 35 0.25 6 8 8 42 58 compensated 70 0.45 12 4 4 21 29 e.g. HQI, HPI, CDM 150 0.75 20 2 2 13 18 250 1.5 33 1 1 9 11 400 2.1 35 1 1 9 10 1000 5.8 95 - - 3 4 2000 11.5 148 - - 2 2 400 V per pole 2000 6.6 58 - - 3 4 3500 11.6 100 - - 2 3 Metal halide lamps 20 0.10 integrated 9 9 18 20 with electronic ballast 35 0.20 integrated 6 6 11 13 (e.g. PCI) 70 0.36 integrated 5 5 10 12 50-125 x I nlamp for 0.6ms 150 0.70 integrated 4 4 8 10 44 www.doepke.co.uk

TECHNICAL SPECIFICATIONS Switching Lamp Loads Type of Lamp Power Current Capacitor W A µf HS20 HS25 HS40 HS63 Low-pressure sodium 35 1.5-7 9 22 30 vapour lamps, 55 1.5-7 9 22 30 uncompensated 90 2.4-4 6 13 19 135 3.5-3 4 10 14 150 3.3-3 4 10 14 180 3.3-3 4 10 14 200 3.3-3 4 10 14 Low-pressure sodium 35 0.31-3 3 15 18 vapour lamps, 55 0.42-2 2 15 18 compensated 90 0.63-1 1 10 12 135 0.94-1 1 8 9 150 1.00-1 1 3 6 180 1.16-1 1 8 9 200 1.32 - - - 10 12 High-pressure sodium 150 1.8-5 6 15 22 vapour lamps, 250 3.0-4 5 10 13 uncompensated 330 3.7-3 4 8 10 400 4.7-2 2 6 8 1000 10.3-1 1 3 4 High-pressure sodium 150 0.83-2 2 20 25 vapour lamps, 250 1.50-1 1 12 15 compensated 330 2.00-1 1 10 13 400 2.40-1 1 8 12 1000 6.30 - - - 4 6 Wall Mounting Twilight Switch Dimensions Contact Assignments Type DASY 16 Operating voltage 230 V AC ± 10%, 50 to 60 Hz Switch contact 16 A Switching capacity Incandescent lamps 3700 W Fluorescent lamps - uncompensated 3700 W - parallel compensated 3700 VA Mercury vapour lamps 3700 VA Setting range 5 to 200 Lux Make delay 10 s Break delay 40 s Ambient temperature range -25 0 C to +40 0 C Enclosure protection type IP 54 Terminals 2.5 mm 2 Housing PC / ABS Cable lead-in: single at the top, double at the bottom with plastic washer and PG 16 at the back sales@doepke.co.uk 45