www.tsurumi.eu GY/UY GRINDER / VORTEX SERIES
Selection Table Motor Output (kw) GY 2" 50mm GYMK 2" 50mm 0.9 1.1 1.5 1.6 1.8 1.9 3.1 3.7 4.4 6.4 9.5 Motor Output (kw) 4" 100mm UY 6" 150mm 4" 100mm UYMK 6" 150mm 1.3 2.6 2.9 3.7 5.0 6.5 22.0 25.6 29.2 33.0 37.4 46.1 Motor Output (kw) 3" 80mm UYZ 4" 100mm 3" 80mm UYZMK 4" 100mm 1.3 2.6 2.9 3.2 3.7 5.0 6.5 8.5 12.2 14.6 19.3 Model Number Designation Discharge size (mm) Name of the series GY: Grinder Pump UY: Vortex Pump Rated motor output in kw Version H: High-head L : High-flow LL: Extra High-flow 50 GY X M K 2 6.4 H 5 1 Option M: Moisture sensor K : Cooling jacket (for Dry Installation) X : Explosion proof (ATEX) Numbers of Poles 50 Hz version Version number 1
General Features Cable entry with anti wicking protection Area of cable connections from 22 kw 4-pole on pressure protected Thermoprotector (Bimetall) Motor cooling Standard=> w/o cooling mantle Option=> with cooling mantle Robust, maintenance-free, permanently lubricated bearings Motor Three-phase-electromotor 4-, 6-pole, IP 68, Isolation-class F (155 ) ATEX Ex II 2 G Eexd (Option) Electrical Moisture control of the oil-chamber (Option) Oil-chamber With outer inspection-screw Mechanical Seal Double mechanical seal (SIC/SIC) Different impellers With big free-passage Available: Grinder Impeller Vortex Impeller Single Channel Impeller Double Channel Impeller Pump Discharge DIN-Flanges (PN 16) 2
GY -Multichannel impeller with cutting mechanism- Cutting Mechanism Open multi-vane channel impeller with cutting mechanism, consisting off a stationary cutting ring and a rotating knife. Entrained particles are crushed in a matter of seconds, piping diameters of DN50 are suitable. Minimization of material costs and costs for relocation. The kind of solids as well as the maximum free-passage need to be considered carefully when choosing the pump. Optional Accessories: Duck-foot for guide-rails: -guide support -duck-foot Bend Stand set for free-standing version Available options: Explosion-proof version Oil chamber sensor for humidity control (only 6.4kW and 9.5kW) Condenser start (230V), direct online (400V, up to 3.1kW), star-delta (400V, from 3.7kW on) All pumps can be operated with soft-starter and variable frequency drive Automatic version with float-switch available for models up to 3.1kW 3
Specifications Free Standing Model Guide Rail Fitting Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Free Standing Guide Rail Fitting Cooling Jacket Option ATEX Option 50GY2.9 TOS50GY2.9 1 50 0.9 3 D.O.L. 32.9 32.9 50GY21.1S TOS50GY21.1S 2 50 1.1 1 Condensor 31.7 31.7 50GY21.5S TOS50GY21.5S 3 50 1.5 1 Condensor 42.3 38.5 50GY21.8S TOS50GY21.8S 4 50 1.8 1 Condensor 42.5 38.6 50GY21.6 TOS50GY21.6 5 50 1.6 3 D.O.L. 42.3 38.4 50GY21.9 TOS50GY21.9 6 50 1.9 3 D.O.L. 42.4 38.5 50GY23.1 TOS50GY23.1 7 50 3.1 3 D.O.L. 49.8 45.9 50GY23.1H TOS50GY23.1H 8 50 3.1 3 D.O.L. 49.8 45.9 50GY23.7 TOS50GY23.7 9 50 3.7 3 Star-Delta 61.3 57.5 50GY24.4 TOS50GY24.4 10 50 4.4 3 Star-Delta 61.3 57.8 50GYM26.4 TOS50GYM26.4 11 50 6.4 3 Star-Delta 107.2 107.4 50GYM26.4H TOS50GYM26.4H 12 50 6.4 3 Star-Delta 110.5 107.4 50GYM29.5 TOS50GYM29.5 13 50 9.5 3 Star-Delta 113.4 110.3 Performance Curves 4
Specifications Φ Dis harge ore mm Pumping Fluid Pump 50mm Temperature 0-35 Type of Fluid Compo- Nents Impeller Shaft Seal Bearings Municipal sewage Multi-vane channel impeller with cutting mechanism Double mechanical seal Shielded ball bearings Material Impeller Grey iron casting EN-GJL-250 Casing Shaft Seal Cutting device Grey iron casting EN-GJL-250 SiC and radial ring in oil bath, SiC, upper in oil bath Stainless steel EN-X39CrMo 17-1 Motor Type, Poles Induction motor, 2 poles, IP68 Lubrication Insulation Motor Protector (built-in) Phase/Voltage Turbine oil (ISO VG32) Insulation class H Miniature protector Single phase 230V / 50Hz, 3-phase / 400V / 50Hz / d.o.l., 3-phase / 400V / 50Hz / s.d. Material Casing Grey iron casting EN-GJL-250 Shaft Stainless steel EN-X5CrNiMo 17-12-2 Cable Rubber, 10m H07RN8-F Discharge Connection Flange DIN / ANSI DN50 (PN10) Optional Accessories Guide rail fitting TO guide support, du k foot end, lifting hain / Bend and stand set for free standing types 5
Dimensions in mm: Model A 50GY2.9 406 50GY21.1S 406 50GY21.5S 468 50GY21.8S 468 50GY21.6 468 50GY21.9 468 50GY23.1 505 50GY23.1H 505 50GY23.7 545 50GY24.4 545 50GYM26.4 771 50GYM26.4H 771 50GYM29.5 844 50GY21.5S 50GY21.8S 50GY21.9 50GY21.6 50GY23.1 50GY23.7 50GY24.4 50GY23.1H 50GYM26.4 50GYM26.4H 50GYM29.5 50GY21.1S 50GY2.9 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions guide rail fitting type in mm: Model B C D E F G 50GY2.9-172 560 457 360 190 50GY21.1S - 172 560 457 360 190 50GY21.5S - 183 630 504 407 223 50GY21.8S - 183 630 504 407 223 50GY21.6-183 630 504 407 223 50GY21.9-183 630 504 407 223 50GY23.1-183 672 504 407 223 50GY23.1H - 183 672 504 407 223 50GY23.7-187 706 527 429 250 50GY24.4-187 706 527 429 250 50GYM26.4 790 - - - - - 50GYM26.4H 790 - - - - - 50GYM29.5 862 - - - - - Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 6
UY -Sewage pump with Vortex-impeller- Vortex Impeller This impeller is used mainly to avoid clogging or wear by large or stringy solids in the water. It accelerates part of the water to great speed, and this speed is used to smoothly move all the water from inlet to outlet. Optional Accessories: Duck-foot for guide-rails: -guide support -duck-foot Bend Stand set for free-standing version Available options: Explosion-proof version Oil sensor Motor versions up to 2.9kW in D.O.L., 3.7kW motor either in D.O.L. or Star-Delta start, from 5kW on only Star-Delta start All pumps can be operated with soft-starter and variable frequency drive 7
Specifications Free Standing Model Guide Rail Fitting Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Free Standing Guide Rail Fitting Impeller passage mm Cooling Jacket Option ATEX Option 100UY41.3 TOS100UY41.3 1 100 1.3 3 Direct 83.7 66.2 80 100UY42.6L TOS100UY42.6L 2 100 2.6 3 Direct 90.7 73.2 80 100UY42.6 TOS100UY42.6 3 100 2.6 3 Direct 90.8 73.3 80 100UY43.7H TOS100UY43.7H 4 100 3.7 3 Direct / Star-Delta 128.1 110.7 80 100UY45.0 TOS100UY45.0 5 100 5.0 3 Star-Delta 131.7 114.3 80 100UY46.5 TOS100UY46.5 6 100 6.5 3 Star-Delta 134.5 117.1 80 Performance Curves 8
Dimensions in mm: Model A B B1 C C1 DN1 DN2 DN3 F1 F2 F3 G H J1 100UY41.3 526 385 240 290 145 100 100 125 213 398 395 617 122 100UY42.6L 563 438 280 316 158 100 100 125 213 395 395 657 122 100UY42.6 563 438 280 316 158 100 100 125 213 398 395 657 122 100UY43.7H 774 438 280 316 158 100 100 125 213 398 395 657 122 100UY45.0 774 438 280 316 158 100 100 125 213 398 395 547 122 100UY46.5 774 438 280 316 158 100 100 125 213 398 395 657 122 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions guide rail fitting type in mm: Model A B B1 C C1 D DN1 DN2 E 100UY41.3 526 385 240 290 145 799 100 100 152 100UY42.6L 563 438 280 316 158 862 100 100 152 100UY42.6 563 438 280 316 158 862 100 100 152 100UY43.7H 774 438 280 316 158 862 100 100 152 100UY46.0 774 438 280 316 158 862 100 100 152 100UY46.5 774 438 280 316 158 862 100 100 152 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 9
Specifications Free Standing Model Guide Rail Fitting Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Free Standing Guide Rail Fitting Impeller passage mm Cooling Jacket Option ATEX Option 150UY422H TOS150UY422H 1 150 22 3 Star-Delta 415.1 387.4 100 150UY425.6 TOS150UY425.6 2 150 25.6 3 Star-Delta 458.2 430.5 100 150UY429.2 TOS150UY429.2 3 150 29.2 3 Star-Delta 463.0 463.0 100 150UY433 TOS150UY433 4 150 33 3 Star-Delta 459.2 431.5 100 150UY437.4 TOS150UY437.4 5 150 37.4 3 Star-Delta 549.9 515.4 100 150UY446.1 TOS150UY446.1 6 150 46.1 3 Star-Delta 590.9 556.4 100 150UY446.1H TOS150UY446.1H 7 150 46.1 3 Star-Delta 590.9 556.4 100 Performance Curves 10
Dimensions in mm: Model A B B1 C C1 DN1 DN2 DN3 F1 F2 F3 G H J1 150UY422H 1353 620 380 464 232 150 200 6 250 380 666 600 1037 273 150UY425.6 1353 620 380 464 232 150 200 6 250 380 666 600 1037 273 150UY429.2 1353 620 380 464 232 150 200 6 250 380 666 600 1037 273 150UY433 1353 620 380 464 232 150 200 6 250 380 666 600 1037 273 150UY437.4 1409 620 380 464 232 150 200 6 250 380 666 600 1037 273 150UY446.1 1409 620 380 464 232 150 200 6 250 380 666 600 1037 273 150UY446.1H 1409 620 380 464 232 150 200 6 250 380 666 600 1037 273 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions guide rail fitting type in mm: Model A B B1 C C1 D DN1 DN2 E 150UY422H 1353 620 380 464 232 1170 150 200 145 150UY425.6 1353 620 380 464 232 1170 150 200 145 150UY429.2 1353 620 380 464 232 1170 150 200 145 150UY433 1353 620 380 464 232 1170 150 200 145 150UY437.4 1409 620 380 464 232 1170 150 200 145 150UY446.1 1409 620 380 464 232 1170 150 200 145 150UY446.1H 1409 620 380 464 232 1170 150 200 145 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 11
Specifications Model Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Impeller passage mm ATEX Option 100UYMK42.9LL 1 100 2.9 3 Direct 159.5 80 100UYMK42.9L 2 100 2.9 3 Direct 159.1 80 100UYMK42.9 3 100 2.9 3 Direct 91.0 80 100UYMK43.7H 4 100 3.7 3 Direct / Star-Delta 159.6 80 100UYMK45.0 5 100 5.0 3 Star-Delta 163.6 80 100UYMK46.5 6 100 6.5 3 Star-Delta 166.5 80 Performance Curves 12
Dimensions vertical installation mm: Model A B B1 C C1 DN1 DN2 J2 K1 K2 K3 K4 L M O 100UYMK42.9LL 767 408 250 316 158 80 100 167 148 357 435 600 195 400 737 100UYMK42.9L 702 438 280 316 158 100 100 197 148 357 445 639 195 400 807 100UYMK42.9 702 438 280 316 158 100 100 197 148 357 445 639 195 400 807 100UYMK43.7H 774 438 280 316 158 100 100 197 148 357 445 639 195 400 807 100UYMK45.0 774 438 280 316 158 100 100 197 148 357 445 639 195 400 807 100UYMK46.5 774 438 280 316 158 100 100 197 148 357 445 639 195 400 807 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions horizontal installation mm: Model B B1 C C1 DN1 DN2 P1 P2 Q R S1 S3 T U V1 100UYMK42.9LL 408 250 316 158 80 100 200 450 250 809 360 110 736 841 260 100UYMK42.9L 438 280 316 158 100 100 200 480 260 806 360 110 664 768 260 100UYMK42.9 438 280 316 158 100 100 200 480 260 806 360 110 663 768 260 100UYMK43.7H 438 280 316 158 100 100 200 480 260 879 360 110 736 841 260 100UYMK45.0 438 280 316 158 100 100 200 480 260 879 360 110 736 841 260 100UYMK46.5 438 280 316 158 100 100 200 480 260 879 360 110 736 841 260 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 13
Specifications Model Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Impeller passage mm ATEX Option 150UYMK422H 1 150 22 3 Star-Delta 510.7 100 150UYMK425.6 2 150 25.6 3 Star-Delta 545.8 100 150UYMK429.2 3 150 29.2 3 Star-Delta 553.6 100 150UYMK433 4 150 33 3 Star-Delta 554.3 100 150UYMK437.3 5 150 37.4 3 Star-Delta 663.7 100 150UYMK446.1 6 150 46.1 3 Star-Delta 708.3 100 150UYMK446.1H 7 150 46.1 3 Star-Delta 708.3 100 Performance Curves 14
Dimensions vertical installation mm: Model A B B1 C C1 DN1 DN2 J2 K1 K2 K3 K4 L M O 150UYMK422H 1353 620 380 464 232 150 200 273 301 692 822 1093 367 560 1121 150UYMK425.6 1353 620 380 464 232 150 200 273 301 692 822 1093 367 560 1121 150UYMK429.2 1353 620 380 464 232 150 200 273 301 692 822 1093 367 560 1121 150UYMK433 1353 620 380 464 232 150 200 273 301 692 822 1093 367 560 1121 150UYMK47.3 1409 620 380 464 232 150 200 273 301 692 822 1093 367 560 1121 150UYMK446.1 1409 620 380 464 232 150 200 273 301 692 822 1093 367 560 1121 150UYMK446.1H 1409 620 380 464 232 150 200 273 301 692 822 1093 367 560 1121 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions horizontal installation mm: Model B B1 C C1 DN1 DN2 P1 P2 Q R S1 S3 T U V1 150UYMK422H 620 380 464 232 150 200 260 640 130 1365 380 115 1158 1263 360 150UYMK425.6 620 380 464 232 150 200 260 640 130 1365 380 115 1158 1263 360 150UYMK429.2 620 380 464 232 150 200 260 640 130 1365 380 115 1158 1263 360 150UYMK433 620 380 464 232 150 200 260 640 130 1365 380 115 1158 1263 360 150UYMK437.3 620 380 464 232 150 200 260 640 130 1424 380 115 1197 1302 410 150UYMK446.1 620 380 464 232 150 200 260 640 130 1424 380 115 1197 1302 410 150UYMK446.1H 620 380 464 232 150 200 260 640 130 1424 380 115 1197 1302 410 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 15
Specifications Φ Dis harge ore mm Pumping Fluid Pump Temperature 0-35 Type of Fluid Compo- Nents Impeller Shaft Seal Bearings 100mm (100UY, 100UYMK), 150mm (150UY, 150UYMK) Municipal sewage Vortex Impeller Double mechanical seal Shielded ball bearings Material Impeller Grey iron casting EN-GJL-250 Casing Shaft Seal Wearring Grey iron casting EN-GJL-250 SiC, upper in oil bath Bronze Motor Type, Poles Induction motor, 4 poles, IP68 Lubrication Insulation Motor Protector (built-in) Phase/Voltage Turbine oil (ISO VG32) Insulation class H Miniature protector 3-phase / 400V / 50Hz / s.d. Material Casing Grey iron casting EN-GJL-250 Shaft Stainless steel EN-X5CrNiMo 17-12-2 Cable Rubber, 10m H07RN8-F Discharge Connection Optional Accessories 100UY, 100UYMK: Flange DIN / ANSI DN100 (PN10) 150UY, 150UYMK: Flange DIN / ANSI DN150 (PN10) 100UY, 150UY: Guide rail fitting TO guide support, du k foot end, lifting hain / Bend and stand set for free standing types 100UYMK, 150UYMK Horizontal installation / Vertical installation 16
UYZ -Sewage pump with Vortex-impeller- Vortex Impeller This impeller is used mainly to avoid clogging or wear by large or stringy solids in the water. It accelerates part of the water to great speed, and this speed is used to smoothly move all the water from inlet to outlet. Optional Accessories: Duck-foot for guide-rails: -guide support -duck-foot Bend Stand set for free-standing version Available options: Explosion-proof version Oil sensor Motor versions up to 2.9kW in D.O.L., 3.7kW motor either in D.O.L. or Star-Delta start, from 5kW on only Star-Delta start All pumps can be operated with soft-starter and variable frequency drive 17
Specifications Free Standing Model Guide Rail Fitting Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Free Standing Guide Rail Fitting Impeller passage mm Cooling Jacket Option ATEX Option 80UYZ41.3 TOS80UYZ41.3 1 80 1.3 3 Direct 78.0 62.7 80 80UYZ42.6L TOS80UYZ42.6L 2 80 2.6 3 Direct 86.2 70.9 80 80UYZ42.6 TOS80UYZ42.6 3 80 2.6 3 Direct 86.3 71.0 80 80UYZ43.7H TOS80UYZ43.7H 4 80 3.7 3 Direct / Star-Delta 123.7 108.4 80 80UYZ45.0 TOS80UYZ45.0 5 80 5.0 3 Star-Delta 127.2 112.0 80 80UYZ46.5 TOS80UYZ46.5 6 80 6.5 3 Star-Delta 130.1 114.8 80 Performance Curves 18
Dimensions in mm: Model A B B1 C C1 DN1 DN2 DN3 F1 F2 F3 G H J1 80UYZ41.3 526 365 220 290 145 80 100 125 203 301 395 589 137 80UYZ42.6L 563 408 250 316 158 80 100 125 203 301 395 628 137 80UYZ42.6 563 408 250 316 158 80 100 125 203 301 395 628 137 80UYZ43.7H 767 468 250 316 158 80 100 125 203 301 395 628 137 80UYZ45.0 767 468 250 316 158 80 100 125 203 301 395 628 137 80UYZ46.5 767 468 250 316 158 80 100 125 203 301 395 628 137 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions guide rail fitting type in mm: Model A B B1 C C1 D DN1 DN2 E 80UYZ41.3 526 365 220 290 145 722 80 100 112 80UYZ42.6L 563 408 250 316 158 775 80 100 112 80UYZ42.6 563 408 250 316 158 775 80 100 112 80UYZ43.7H 767 408 250 316 158 775 80 100 112 80UYZ45.0 767 408 250 316 158 775 80 100 112 80UYZ46.5 767 408 250 316 158 775 80 100 112 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 19
Specifications Free Standing Model Guide Rail Fitting Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Free Standing Guide Rail Fitting Impeller passage mm Cooling Jacket Option ATEX Option 100UYZ43.2 TOS100UYZ43.2 1 100 3.2 3 Star-Delta 97.9 80.5 100 100UYZ45.0 TOS100UYZ45.0 2 100 5.0 3 Star-Delta 134.3 116.9 100 100UYZ46.5 TOS100UYZ46.5 3 100 6.5 3 Star-Delta 136.9 119.5 100 100UYZ48.5 TOS100UYZ48.5 4 100 8.5 3 Star-Delta 176.1 158.7 100 100UYZ412.2 TOS100UYZ412.2 5 100 12.2 3 Star-Delta 215.5 196.8 100 100UYZ414.6 TOS100UYZ414.6 6 100 14.6 3 Star-Delta 216.4 197.7 100 100UYZ419.3 TOS100UYZ419.3 7 100 19.3 3 Star-Delta 239.8 221.1 100 Performance Curves 20
Dimensions in mm: Model A B B1 C C1 DN1 DN2 DN3 F1 F2 F3 G H J1 100UYZ43.2 630 410 250 296 148 100 100 125 225 410 395 626 122 100UYZ45.0 630 410 250 296 148 100 100 125 225 410 395 626 122 100UYZ46.5 804 460 280 336 168 100 100 4: 125 225 410 395 657 122 100UYZ48.5 914 460 280 336 168 100 100 125 225 410 395 657 122 100UYZ412.2 994 576 345 457 207 100 150 125 260 445 450 755 122 100UYZ414.6 1098 555 345 410 205 100 150 125 235 420 450 749 122 100UYZ419.3 1098 555 345 410 205 100 150 125 235 420 450 749 122 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions guide rail fitting type in mm: Model A B B1 C C1 D DN1 DN2 E 100UYZ43.2 630 410 250 296 148 834 100 100 140 100UYZ45.0 804 460 280 336 168 1029 100 100 175 100UYZ46.5 804 460 280 336 168 1029 100 100 175 100UYZ48.5 914 460 280 336 168 884 100 100 140 100UYZ412.2 994 576 345 457 207 1000 100 150 105 100UYZ414.6 1098 555 345 410 205 979 100 150 130 100UYZ419.3 1098 555 345 410 205 979 100 150 130 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 21
Specifications Model Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Impeller passage mm ATEX Option 80UYZMK42.9LL 1 80 2.9 3 Direct 155.0 80 80UYZMK42.9L 2 80 2.9 3 Direct 154.6 80 80UYZMK42.9 3 80 2.9 3 Direct 90.0 80 80UYZMK43.7H 4 80 3.7 3 Direct / Star-Delta 155.2 80 80UYZMK45.0 5 80 5.0 3 Star-Delta 159.2 80 80UYZMK46.5 6 80 6.5 3 Star-Delta 162.0 80 Performance Curves 22
Dimensions vertical installation mm: Model A B B1 C C1 DN1 DN2 J2 K1 K2 K3 K4 L M O 80UYZMK42.9LL 702 365 220 290 145 80 100 167 148 357 435 600 195 400 707 80UYZMK42.9L 702 408 250 316 158 80 100 167 148 357 435 600 195 400 737 80UYZMK42.9 702 408 250 316 158 80 100 167 148 357 435 600 195 400 737 80UYZMK43.7H 767 408 250 316 158 80 100 167 148 357 435 600 195 400 737 80UYZMK45.0 767 408 250 316 158 80 100 167 148 357 435 600 195 400 737 80UYZMK46.5 767 408 250 316 158 80 100 167 148 357 435 600 195 400 737 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions horizontal installation mm: Model B B1 C C1 DN1 DN2 P1 P2 Q R S1 S3 T U V1 80UYZMK42.9LL 365 220 290 145 80 100 200 420 250 809 360 110 663 768 260 80UYZMK42.9L 408 250 316 158 80 100 200 450 250 809 360 110 663 768 260 80UYZMK42.9 408 250 316 158 80 100 200 450 250 809 360 110 663 768 260 80UYZMK43.7H 408 250 316 158 80 100 200 450 250 809 360 110 736 841 260 80UYZMK45.0 408 250 316 158 80 100 200 450 250 809 360 110 736 841 260 80UYZMK46.5 408 250 316 158 80 100 200 450 250 809 360 110 736 841 260 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 23
Specifications Model Colour code curve Bore mm Power output kw Phase Starting Method Dry weight kg without cable Impeller passage mm ATEX Option 100UYZMK43.7 1 100 3.7 3 Direct / Star-Delta 161.2 100 100UYZMK45.0 2 100 5.0 3 Star-Delta 166.2 100 100UYZMK46.5 3 100 6.5 3 Star-Delta 168.8 100 100UYZMK48.5 4 100 8.5 3 Star-Delta 214.7 100 100UYZMK412.2 5 100 12.2 3 Star-Delta 290.4 100 100UYZMK414.6 6 100 14.6 3 Star-Delta 291.3 100 100UYZMK419.3 7 100 19.3 3 Star-Delta 318.0 100 Performance Curves 24
Dimensions vertical installation mm: Model A B B1 C C1 DN1 DN2 J2 K1 K2 K3 K4 L M O 100UYZMK43.7 731 410 250 296 148 100 100 197 148 357 457 652 197 400 777 100UYZMK45.0 804 460 280 336 168 100 100 197 148 357 457 652 197 400 807 100UYZMK46.5 804 460 280 336 168 100 100 197 148 357 457 652 197 400 807 100UYZMK48.5 914 460 280 336 168 100 100 197 148 357 457 652 197 400 807 100UYZMK412.2 994 576 345 457 207 100 150 197 205 500 637 832 197 520 942 100UYZMK414.6 1098 555 345 410 205 100 150 197 205 502 612 806 197 520 941 100UYZMK419.3 1098 555 345 410 205 100 150 197 205 502 612 806 197 520 941 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately Dimensions horizontal installation mm: Model B B1 C C1 DN1 DN2 P1 P2 Q R S1 S3 T U V1 100UYZMK43.7 410 250 296 148 100 100 200 450 100 664 280 95 506 601 260 100UYZMK45.0 460 280 336 168 100 100 200 480 100 737 280 95 579 674 260 100UYZMK46.5 460 280 336 168 100 100 200 480 100 737 280 95 579 674 260 100UYZMK48.5 460 280 336 168 100 100 200 480 100 926 280 95 767 862 310 100UYZMK412.2 576 345 457 207 100 150 250 595 135 1006 350 120 842 952 310 100UYZMK414.6 555 345 410 205 100 150 230 575 110 1110 380 115 941 1046 310 100UYZMK419.3 555 345 410 205 100 150 230 575 110 1110 380 115 941 1046 310 Please mind: discharge bend, duck foot bend and stand set are accessories and must be ordered separately 25
Specifications Φ Dis harge ore mm Pumping Fluid Pump Temperature 0-35 Type of Fluid Compo- Nents Impeller Shaft Seal Bearings 80mm (80UYZ, 80UYMK), 100mm (100UYZ, 100UYZMK) Municipal sewage Vortex Impeller Double mechanical seal Shielded ball bearings Material Impeller Grey iron casting EN-GJL-250 Casing Shaft Seal Wearring Grey iron casting EN-GJL-250 SiC, upper in oil bath Bronze Motor Type, Poles Induction motor, 4 poles, IP68 Lubrication Insulation Motor Protector (built-in) Phase/Voltage Turbine oil (ISO VG32) Insulation class H Miniature protector Material Casing Grey iron casting EN-GJL-250 3-phase / 400V / 50Hz / d.o.l, 3-phase / 400V / 50Hz / s.d. Shaft Stainless steel EN-X5CrNiMo 17-12-2 Cable Rubber, 10m H07RN8-F Discharge Connection 80UYZ, 80UYZMK: Flange DIN / ANSI DN80 (PN10) 100UYZ, 100UYZMK: Flange DIN / ANSI DN100 (PN10) Optional Accessories 80UYZ, 100UYZ: Guide rail fitting TO guide support, du k foot end, lifting hain / Bend and stand set for free standing types 80UYZMK, 100UYZMK: Horizontal installation / Vertical installation 26
www.tsurumi.eu We reserve the right to change the specifications and designs for improvement without prior notice. TSURUMI (EUROPE) GMBH Wahlerstrasse 10, 40472 Düsseldorf, Germany T: +49 211 417973 F: +49 211 417937-480 e-mail: sales@tsurumi.eu website: www.tsurumi.eu Your Dealer CAT NO. 20161206SF