General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

Similar documents
General Principles 9-3-Trapped Key. Switches. 11-Cat. No. Index. Logic Power Stainless steel construction.

General Principles 9-3-Trapped Key. Switches. 11-Cat. No. Index. Logic Power Stainless steel construction.

General Principles 9-3-Trapped Key. Switches. 11-Cat. No. Index. Logic Power Stainless steel construction.

General Principles 9-3-Trapped Key. Switches. 11-Cat. No. Index. Logic Power Stainless steel construction.

NHP SAFETY REFERENCE GUIDE

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

INSTRUMENT PANEL CLUSTERS

Order No. of the options EMC filter Class A

Protection Equipment

SIRIUS 3RU2 Thermal Overload Relays

Protection Equipment. 5/2 Introduction

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Limit Switches and Safety

Campaign no.: Date: July 13, 2006 Subject: Fluctuating and Sticking No Speedometer Needle

3VF3 to 3VF8 Circuit-Breakers

IEC fuse holders & fuse disconnectors: CMS 14

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

Position and Safety Switches

LYCOMING CYLINDER PRICING

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

Motor Starter Protectors

Motor Starter Protectors

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

2 Finger, 3 Finger, 4 Finger Parallel Style Air Gripper. Series MHS. MHZ MHF MHL MHR MHK MHS MHC MHT MHY MHW MRHQ Misc.

SENTRON VL Series Product Specifications

Direct solenoid and solenoid pilot operated valves

3VT Kompaktleistungsschalter bis 630A

2. COMPACT CYLINDERS series STRONG (RS, RQ)

MAC VALVES, INC. Rev. T

M/1000, Heavy Duty Cylinders Double Acting

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved

Industrial Controls. Load Feeders. Configuring the SIRIUS Modular System Selection data for Fuseless and Fused Load Feeders. Configuration Manual

Manual Motor Starters. Meta-MEC

3VU13, 3VU16 Circuit-Breakers

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

D509E. Manual Motor - Starters

Industrial Performance Motors. New Aluminum and Cast Iron Motors. Flexibility

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

AQUAKITS. life made easy. smart shower solutions

3NP1 Fuse Switch Disconnectors up to 630 A

TeSys GS. Data for Designers. Contents

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

SSR SSR SSR SSR

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale)

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Phelan. Electromec ELECTROMEC LOAD BREAK SWITCHES. APPROVALS For Canada and US APPLICATIONS DESIGN FEATURES

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

CHIP FUSE; RECTANGULAR TYPE FCC10,16,20,32, FHC10,16,20,32. RoHS COMPLIANCE ITEM Halogen and Antimony Free

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

American Round Fuses - Form 101 range

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Series MHSH3. ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80 Through Hole. How to Order. Dust cover type (with dust cover only)

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Direct solenoid and solenoid pilot operated valves

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Direct solenoid and solenoid pilot operated valves

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Safety Limit Switch

3 - Protection components Motor circuit-breakers

SIRIUS Configuration

Position switches FD series

Meta Solution. Contactors and Overload relays

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

AF40... AF96 3-pole contactors Technical data

3RG4 BERO Inductive Proximity Switches

CLOGGING INDICATORS SUMMING-UP DESCRIPTION

Guided compact cylinder General

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

and legacy Motor Control Center Aftermarket Renewal Parts Catalog

TeSys GS & DF Fuse protection

Ø64 LOAD BREAK SWITCHES Ø4.5 Ø12 Ø48. Panel Door

8WH6 ipo Installation Terminals

Series 83. Stainless Steel Mini Cylinder

Field Variable Area Flowmeters BFP Global Purgemaster

S: With magnet. Bore x stroke (basic type) Cushion P: pneumatic adjustable

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Safety switches with solenoid and separate actuator

Parallel Type Air Gripper/2 Finger, 3 Finger, 4 Finger

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

~... se_rv_ic_e M_A_NU_AL_2_44_4._z1,~

P1X Series. Compact Rodless Air Cylinders Contents

Control switch/load disconnect switch Series 8008

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Transcription:

R Safety Trapped Key Overview Key Coding Below is an example reference guide that is useful in selecting and tracking codes. Start down the Aa column as the lower codes (typically Aa to Za) are stocked. The chart continues on to Zz. Note that there are only 24 letters used O & Q are not used. Codes are ordered with upper case letters. Labels with two letter codes will show the first letter in the upper case and the second letter in lower case. General 9- Power 3-Trapped Key Logic Principles Code Aa Ba Ca Da Ea Fa Ga Ha Ia Ja Ka La Ma Na Pa Ra Sa Ta Ua Va Wa Xa Ya Za & Date Code & Date Code & Date Code & Date Code & Date Code Ab Ac Ad Ae Af Bb Bc Bd Be Bf Cb Cc Cd Ce Cf Db Dc Dd De Df Eb Ec Ed Ee Ef Fb Fc Fd Fe Ff Gb Gc Gd Ge Gf Hb Hc Hd He Hf Ib Ic Id Ie If Jb Jc Jd Je Jf Kb Kc Kd Ke Kf Lb Lc Ld Le Lf Mb Mc Md Me Mf Nb Nc Nd Ne Nf Pb Pc Pd Pe Pf Rb Rc Rd Re Rf Sb Sc Sd Se Sf Tb Tc Td Te Tf Ub Uc Ud Ue Uf Vb Vc Vd Ve Vf Wb Wc Wd We Wf Xb Xc Xd Xe Xf Yb Yc Yd Ye Yf Zb Zc Zd Ze Zf & Date 3-107

Safety Rotary Specifications (continued) General Principles 9-3-Trapped Key Logic Power Description The rotary switches are used for electrical isolation of machinery to improve safe access and also as teach boxes in robot cells. Once the power has been turned off, the key can then be withdrawn and used in the next sequence of operation such as unlocking an access hatch or allowing valves to be operated. The rotary switch can either be mounted in a panel or purchased in an enclosure. The rotary switch is available with 4 poles, either 4 N.O. or 2 N.C. and 2 N.O. The 100 A switch has 3 contacts rated at 100 A and 1 contact rated at. Features 316L stainless steel keys Direct drive operation positively opens contacts Stainless steel dust cap included Up to 400 A isolation, 2 N.O. and 2 N.C., 3 N.O./1 N.C., 3 N.O., or 3 N.C. and neutral contacts Replaceable code barrel assembly Specifications Safety Ratings Standards Category Certifications EN1088, IEC/EN60204-1, IEC/EN60947-5-1, ISO12100-1&2, ISO14119, GS-ET- 19, AS4024.1, UL508, CSA 22.2 Cat. 1 per EN 954-1 (ISO 13849-1) Suitable for Cat. 2, 3, and 4 systems CE Marked for all applicable directives, BG, culus on contact block; C-Tick not required Operating Characteristics Conduit Entry 4 x M20 (RKS only) Mechanical Life 100,000 operations Finger Protection DIN 57106/VDE 0106 T.100 Environmental Characteristics Operating Temperature [C (F)] -10 +40 (14 104 ) Relative Humidity 95% Physical Characteristics Shear Force to Key 15.1 k N (3398 lbs), Torque to Key 14 N m (124 lb in), The Prosafe Advantage Weight [g (lbs)] Electrical Life Climatic Test Stainless steel construction. RPSE RKSE Ambient Temperature, Operation (Ui) Rated Insulation Voltage (Uimp) Rated Impulse withstand Voltage S3 Intermittent Rating Duty Factor (VDE 0530, Part 1) Last two digits of Cat. No. (See Product Selection table) Rated Uninterrupted Current (Iu) Rated Operational Voltage (Ue) Rated Operational Current (Ie) Rated Operational Power at 50/60 Hz (AC-23A IEC/EN/VDE) Rated Operational Power at 50/60 Hz (AC-3A IEC/EN/VDE) DOL Rating (UL/CSA) Rated Breaking Capacity Fuse Rating (GI) 10, 11, 12, 13, 20: 500 (1.1) 14, 16: 10, 11, 850 (1.9) 14, 16: 12, 13: 100,000 operations 1000 (2.2) 1250 (2.8) Constant to DIN IEC 68 Part 2-3 Variable to DIN IEC 68 Part 2-30 Encased -25 40 C (10 104 F) 690V 6 kv 60/40/25% = 1, 3/1, 6/2 xlu 10 11 16 12 13 14 IEC/EN/VDE 20A 32A 63A 100A UL/CSA 16A 30A 60A 100A IEC/EN/VDE 690V 690V 690V 1000V UL/CSA 600V 600V 600V 600V Main Switch Isolation 750V 750V 750V 1000V Voltage, Max. AC-21A 20A IEC/EN/VDE 32A 63A 100A AC-1 SEV 20A 32A 63A 100A 3-phase 4 kw 220 240V 5.5 kw 15 kw 22 kw 3-pole 7.5 kw 380 440V 11 kw 22 kw 37 kw 500 690V 7.5 kw 11 kw 22 kw 37 kw 3-phase 3 kw 220 240V 4 kw 11 kw 22 kw 3-pole 5.5 kw 380 440V 7.5 kw 18.5 kw 30 kw 500 690V 5.5 kw 7.5 kw 18.5 kw 30 kw 3-phase 140V 1 HP 2 HP 5 HP 10 HP 3-pole 240V 2 HP 5 HP 15 HP 25 HP 480V 5 HP 10 HP 30 HP 30 HP 600V 5 HP 10 HP 40 HP 30 HP AC-23/AC-3 250A 220 240V 330A 500A 600A Motor Switch 250A 380 440V 330A 500A 600A 500 690V 150A 220A 2A 300A 25 A, 35 A, 63/50 A, 100 A, Rated Fuse Short Circuit Current 15 ka 15 ka 15/20 ka 25 ka Terminal Cross Section Conductor Size, mm2 min max 1 10 4 16 2.5 3.5 mm2 single/multiple wire 0.75 6 2.5 10 1.5 2.5 (stranded) with sleeve 8 AWG 6 AWG 2 AWG 3-108 R

R Safety Rotary Product Selection Type Contact Type Current Accuracy Cat. No. 440T-MRKSE10 2 N.O. & 2 N.C. 440T-MRKSE11 32 A 440T-MRKSE12 63 A 440T-MRKSE13 General 3 N.O. & 1 N.O. 3 N.O. 100 A and 1 N.O. 440T-MRKSE14 Enclosure Mounted (RKS only) 8 N.O. 440T-MRKSE16 Mild Steel Enclosure Mounted (RKS only) 3 N.O. + Neutral 200 A 440T-MRKSE21 3 N.O. 400 A 440T-MRKSE22 440T-MRPSE10 2 N.O. & 2 N.C. 440T-MRPSE11 32 A 440T-MRPSE12 63 A 440T-MRPSE13 3 N.O. & 1 N.O. 3 N.O. 100 A and 1 N.O. 440T-MRPSE14 8 N.O. 440T-MRPSE16 3 N.O. & 3 N.C. 440T-MRPSE18 Panel Mounted 40 A 440T-MRPSE20 Principles Substitute the desired primary code for this symbol (key not included). See page 3-107. Isolator on First Key Out Type Number of Keys Contact Type Current Accuracy Cat. No. Dual key isolator Triple key isolator Quad key isolator Dual key exchange isolator Triple key exchange isolator Quad key exchange isolator 2 keys out 3 keys out 4 keys out 1 key in/ 1 key out 1 key in/ 2 key out 1 key in/ 3 key out Substitute the desired primary code for this symbol (key not included). See page 3-107. Substitute the desired secondary code for this symbol (key included). See page 3-107. 440T-MMRSE10 2 N.O. & 2 N.C. 440T-MMRSE11 32 A 440T-MMRSE12 63 A 440T-MMRSE13 440T-MMRSE20 2 N.O. & 2 N.C. 440T-MMRSE21 32 A 440T-MMRSE22 63 A 440T-MMRSE23 440T-MMRSE30 2 N.O. & 2 N.C. 440T-MMRSE31 32 A 440T-MMRSE32 63 A 440T-MMRSE33 440T-MMRXE10 2 N.O. & 2 N.C. 440T-MMRXE11 32 A 440T-MMRXE12 63 A 440T-MMRXE13 440T-MMRXE20 2 N.O. & 2 N.C. 440T-MMRXE21 32 A 440T-MMRXE22 63 A 440T-MMRXE23 440T-MMRXE30 2 N.O. & 2 N.C. 440T-MMRXE31 32 A 440T-MMRXE32 63 A 440T-MMRXE33 9-3-Trapped Key Logic Power 3-109

Safety Rotary General Principles 9-3-Trapped Key Accessories Description Additional Information Cat. No. Stainless steel key 440T-AKEYE10 Stainless steel replacement code barrel for products other than 100 A RPS/RKS units with dust cap 3-140 440T-ASCBE14 Stainless steel replacement code barrel for 100 A unit rotary switch 440T-ASCBE11 Stainless steel weatherproof replacement dust cap 440T-ASFC10 Cable grip, M20 conduit, accommodates cable diameter 7 10.5 mm (0.27 0.41 in.) 3-53 440A-A09028 Adaptor, conduit, M20 to 1/2 inch NPT, plastic 440A-A09042 Supplemental Contact Block,, 1 N.O. Late Make, Early Break 1 N.C. Auxiliary For use with RPSE12, RPSE20 (maximum 1 per switch) 440T-AACA10 Supplemental Contact Block,, 2 N.O. Late Make, Early Break For use with RPSE12, RPSE20 (maximum 1 per switch) 440T-AACA11 Supplemental Contact Block,, 1 N.O., 1 N.C. For use with RPSE13 & 14 440T-AACA20 Supplemental Contact Block,, 2 N.O. For use with RPSE13 & 14 440T-AACA21 ABS plastic enclosure For use with dual key, and dual key exchange, isolators 440T-AIPB10 Stainless steel enclosure (240x180x150 mm) For use with > RPSE units (not including RPSE21 or 22) 440T-AIPB25 Stainless steel enclosure (150x150x80 mm) For use with RPSE10 & 11 440T-AIPB26 ABS plastic enclosure For use with triple/quad key, and triple/quad key exchange, isolators 440T-AIPB50 Stainless steel enclosure For use with triple/quad key, and triple/quad key exchange, isolators 440T-AIPB55 Substitute the desired primary code for this symbol (key not included). See page 3-107. Approximate Dimensions [mm (in.)] Dimensions are not intended to be used for installation purposes. MRKSE10 and MRKSE11 100 (3.93) MMRSE10 80 (3.14) 4 M20 KNOCKOUTS (2 PER END) 85.7 (3.37) 129.2 (4.99) 60 (2.36) VIEW OF BASE FIXINGS 4 FIXINGS Ø4.5 (0.17) 60 (2.36) MRKSE12 and MRKSE13 Coded Key Weather Cap Cover Cover Code Barrel Adaptor Plate 23 (0.9) 115 (4.52) 175 (6.88) 39 (1.53) 24 (0.94) 46 (1.81) 80 (3.14) 88.4 (3.48) 60 (2.35) 4 Off Ø20 mm (0.78) Knockouts Typical Position 2 Off Top and 2 Off Bottom MMRSE20 2 Off M4 Mounting Holes 2 Off 20 mm dia. (0.78) Knockouts On Rear Face 61 (2.4) A 125 (4.92) 165 (6.49) Mounting Centers View On A Logic Power 35 (1.38) 35 (1.38) 150 (5.91) 90 (3.54) R4 82 (3.23) PANEL CUTOUT 100 (3.94) 90 (3.54) SIX HOLES Ø4.5 (0.18) MOUNTING HOLES Ø4.2 (0.17) 69 (2.72) 89 (3.5) 3 4 5 6 7 8 ISOLATOR KEY FREE 168 158 (6.61) (6.22) ISOLATOR CONTACTS (KEY FREE) 3 5 6 4 69 (2.72) 97 (3.82) 130 (5.12) 130 (5.12) 246 (9.69) PANEL CUT-OUT 2 (10.63) KEYS SUPPLIED SEPERATELY 144 (5.67) PANEL CUT-OUT SIX MOUNTING HOLES Ø4.5 (0.18) 3-110 R

R Safety Rotary Approximate Dimensions [mm (in.)] (continued) Dimensions are not intended to be used for installation purposes. MRKSE14 OFF MRKSE16 Weather Cap 80 (3.15) 2 Off M4 Mounting Holes External General ON 100 (3.98) A 60 crs 90 crs 160 (6.3) Unit in Off Position Key Removed M25/M32 Conduit Entry Knockouts 2 per end 100 (3.98) Coded Key Code Barrel Adaptor Plate 85 (3.35) 163 (6.42) 60 crs View on A 4 Off M4 Mounting Holes Internal Principles 44 crs 18 (0.71) 4 Off 20 (0.79) Dia. Knockouts Typical Position 2 Off Top & 2 Off Bottom 250 (9.8) 240 (9.4) 100 (3.98) MRPSE10 and 11 9-64 (2.51) Code Barrel.4 (2.77) 16 (0.62) 96 (3.78) Base Mountings M4 Fixings 110.5 (4.35) Unit in On Position Key Trapped MRPSE 12, 13, 14 and 20 16 (0.6) 32 (1.26) Code Barrel 3 (0.12) Panel Thickness 16 (0.6) 64 (2.51) Legend Plate 2 Holes 4.0 (0.15) Dia. 20.0 (0.78) Dia. Mounting Screws 34 (1.33) 3 mm Panel Thickness Mounting Block 44.4 (1.74) Dia. 58 (2.28) Dia. 3-Trapped Key Hole 20 (0.79) Panel Mounting Details OFF 2 Holes ±4.0 (0.15) Dia. Weather Cap Fixing Screws ±23 (0.9) 25 (0.98) Mtg. Block Switch Unit 71.5 (2.8) 55.5 (2.19) Logic Power 25 (0.98) 16.0 (0.62) Panel Mounting Details 32.0 (1.25) Switch Unit 64 Square Legend Plate ON Legend Plate Drive Adaptor Panel 43 (1.69) 3-111

Safety Rotary Approximate Dimensions [mm (in.)] (continued) MMRXE10 and MMRXE11 General Principles 9-3-Trapped Key 150 (5.91) MMRXE30 168 158 (6.61) (6.22) SIX MOUNTING HOLES Ø4.5 (0.18) 100 (3.94) A B MADE IN GBR 90 (3.54) 2 (10.63) 130 (5.12) 130 (5.12) PRIMARY KEY 56 56 (2.2) SECONDARY KEY #1 56 (2.2) 56 (2.2) SECONDARY KEY #2 SECONDARY KEY #3 PRIMARY SECONDARY MOUNTING HOLES Ø4.2 (0.17) 63 (2.48) 95 (3.74) 87 (3.43) ISOLATOR MRXE10 - MRXE11-2 N.O./2 N.C. MRKSE22 600 (23.62) 450 (17.72) 280 (11.02) PAINTED STEEL CABINET 3 4 5 6 ISOLATOR ON FIRST SECONDARY KEY ISOLATOR HANDLE SINGLE KEY BOLTLOCK Logic Power 3-112 R

R Safety Rotary Approximate Dimensions [mm (in.)] (continued) MRPSE16 16 (0.6) 32 (1.26) Code Barrel 3 (0.12) Panel Thickness 16 (0.6) General Hole 20 (0.79) 2 Holes ±4.0 (0.15) Dia. ±23 (0.9) 46 (1.8) Dia. Panel Mounting Details Weather Cap Fixing Screws 25 (0.98) Mounting. Block Switch Unit Principles OFF ON 9- Legend Plate Panel Drive Adaptor Typical Wiring Diagrams Shown with Key Free 3-Trapped Key Logic Power 3 4 5 6 3 4 5 6 (100A) 3 4 (100A) 5 6 (100A) (20A) 3 4 5 6 MRKSE10 and MRPSE10 MRKSE12 and MRPSE12 MRKSE13 and MRPSE13 ----------- and MRPSE20 MMRSE10 and MMRXE10 MMRSE12 and MMRXE12 MMRSE13 and MMRXE13 MMRSE20 and MMRXE20 MMRSE22 and MMRXE22 MMRSE23 and MMRXE23 MMRSE30 and MMRXE30 MMRSE32 and MMRXE32 MMRSE33 and MMRXE33 MRKSE11 and MRPSE11 MMRSE11 and MMRXE11 MMRSE21 and MMRXE21 MMRSE31 and MMRXE31 MRKSE14 and MRPSE14 3 4 5 6 9 10 9 10 11 12 13 14 15 16 MRKSE16 and MRPSE16 11 12 MRKSE18 and MRPSE18 3-113

Safety Solenoid Release Units General Principles 9-3-Trapped Key Description The solenoid release unit is used for electrical isolation of machinery to improve safe access. It consists of a rotary power switch and a solenoid. The trapped key can be removed once an external signal is given to its internal solenoid locking mechanism. An indicator light on the solenoid release unit indicates when the trapped key can be removed; that is, when power is applied to the solenoid. The solenoid signal only needs to be present when key removal is necessary. The solenoid is rated for 100% duty cycle. Power to the solenoid can be removed after the trapped key is removed. Rotating the trapped key causes the isolating power switch to change state; the normally open contacts open and the normally closed contacts (if applicable) will close. The trapped key can then be used in the next sequence of the operation. Features Direct drive operation positively opens contacts Integral solenoid monitoring Key trapped until release signal is applied LED or NEON "key free" indication 316L stainless steel construction, 110V AC or 230V AC solenoid options Weatherproof stainless steel dust cap as standard UL and CSA Approval on switches Single or multiple key units available (contact factory) Replaceable code barrel assembly Specifications Safety Ratings EN1954-1, IEC/EN60204-1,EN1088, IEC/EN60947-5-1, ISO13849-1, Standards ISO12100-1&2, ISO14119, GS-ET-19, AS4024.1 CE Marked for all applicable directives Certifications and BG Operating Characteristics Solenoid Voltage, 110V AC, 230V AC DC Types: 6.5 W continuous Solenoid Power AC Types: 6V A continuous Electrical Life 100,000 operations Mechanical Life 100,000 operations Utilization Category Electrical Characteristics See rotary power switches. Environmental & Physical Characteristics Shear Force to Key 15.1 k N (3398 lbs), Torque to Key 14 N m (124 lb in), Trapped Key Components: 316L stainless steel Material Steel Face Plate: 316L stainless steel Optional Box: ABS plastic Operating Temperature [C (F)] 0 40 (32 104 ) Relative Humidity 95% Logic Power The Prosafe Advantage Stainless steel construction. 3-114 R

R Safety Solenoid Release Units Product Selection Type Solenoid Voltage Contacts Current, Nom Cat. No. Single key out Dual key out Triple key out Quad key out 110V AC 230V AC 110V DC Substitute the desired primary code for this symbol (key not included). See 3-107. 2 N.O. & 2 N.C. 440T-MSRUE11 440T-MSRUE10 32 A 440T-MSRUE12 3 N.O. & 3 N.C. 440T-MSRUE13 2 N.O. & 2 N.C. 440T-MSRUE22 440T-MSRUE20 32 A 440T-MSRUE23 3 N.O. & 3 N.C. 440T-MSRUE14 63 A 440T-MSRUE24 2 N.O. & 2 N.C. 440T-MSRUE33 440T-MSRUE30 32 A 440T-MSRUE34 63 A 440T-MSRUE35 2 N.O. & 2 N.C. 440T-MSRUE44 440T-MSRUE40 3 N.O. & 3 N.C. 440T-MSRUE46 440T-MS2097D 2 N.O. & 2 N.C. 440T-MS2097A 32 A 440T-MS2097G 63 A 440T-MS2097J 440T-MS3417D 2 N.O. & 2 N.C. 440T-MS3417A 32 A 440T-MS3417G 63 A 440T-MS3417J 440T-MS3418D 2 N.O. & 2 N.C. 440T-MS3418A 32 A 440T-MS3418G 63 A 440T-MS3418J Accessories Description Additional Information Cat. No. Stainless steel key 440T-AKEYE10 Stainless steel replacement code barrel with dust cap 3-140 440T-ASCBE14 Stainless steel weatherproof replacement dust cap 440T-ASFC10 Optional plastic enclosure For use with single key out units 440T-AIPB10 For use with single key out 32 A units 440T-AIPB22 Optional ABS plastic enclosure For use with triple/quad key out units 440T-AIPB50 Optional stainless steel enclosure For use with triple/quad key out units 440T-AIPB55 Substitute the desired primary code for this symbol (key not included). See 3-107. General Principles 9-3-Trapped Key Power Logic 3-115

Safety Solenoid Release Units General Principles 9-3-Trapped Key Approximate Dimensions [mm (in.)] Dimensions are not intended to be used for installation purposes. MSRUE13 (11 W) 35 (1.38) 35 (1.38) 90 (3.54) R4 82 (3.23) MSRUE35 230V AC (17VA) 97 (3.82) 66 (2.6) PANEL CUTOUT 6 HOLES Ø4.2 (0.17) ISOLATOR CONTACTS 3 N.O./3 N.C. (KEY FREE) 3 5 7 9 1 11 SIX HOLES Ø4.5 (0.18) 2 4 6 8 10 12 INPUT 100 (3.94) 90 (3.54) 150 (5.91) MONITOR SWITCHES (KEY TRAPPED) 100 (3.94) 90 (3.54) 150 (5.91) MS2097 168 (6.61) 63 (2.5) 69 (2.72) 95 (3.74) MS3417 168 (6.61) 2 (10.63) 130 (5.12) 130 (5.12) KEY#1 246 (9.69) CUTOUT KEY#2 ISOLATOR LOCKING KEY #1 1 3 4 5 6 2 (10.63) 130 (5.12) 130 (5.12) 2 158 (6.22) 144 (5.67) CUTOUT 158 (6.22) INPUT MONITOR SWITCHES (KEY TRAPPED) 230V AC ISOLATOR AND ON FIRST KEY 32 A ISOLATOR 35 (1.38) 35 (1.38) 35 90 (3.54) R4 82 (3.23) 66 (2.6) 92 (3.62) PANEL CUTOUT SIX HOLES Ø4.5 (0.18) 6 HOLES Ø4.2 (0.17) ISOLATOR CONTACTS 63 A (KEY FREE) 1 2 3 4 5 6 230V AC INPUT MONITOR SWITCHES (KEY TRAPPED) Logic Power Typical Wiring + MC MC Gnd 3-116 R