Aqua Metrix. Water Analytics AquaMetrix Price List. AquaMetrix products are manufactured by. Water Analytics

Similar documents
Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

Model Q45H/ Residual Chlorine Monitor...

Signet 3719 ph/orp Wet-Tap Assembly

OPERATING INSTRUCTION MANUAL

Signet ph/orp Electrodes

Signet DryLoc ph/orp Electrodes

SeaMetrics Flow Meters and Flow Computers

Signet ph/orp Electrodes

* * Rev. 9 01/18 Product Manual

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

Signet Conductivity/Resistivity Electrodes

Signet DryLoc ph/orp Electrodes

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

Signet Measurement and Instrumentation

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

Signet Conductivity/Resistivity Electrodes

NEW QUICK CABLE-TO-SENSOR RELEASE,

Accessories Guide ph/orp/conductivity Sensors

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Low Cost Submersion and In-Line ph Electrodes

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller

Signet 2760 DryLoc ph/orp Preamplifier

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

Signet Measurement and Instrumentation

ph/orp Sensor Model 399 ph/orp

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Signet ph/orp Electrodes

Signet 3719 ph/orp Wet-Tap

SIGNET 2760 DryLoc ph/orp Preamplifier

SOLENOID DRIVEN DOSING PUMPS

Dissolved Oxygen Measurement System with Air Blast Cleaner

Digital ph transmitter

General Purpose Toroidal Conductivity Sensors

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

General Purpose ph/orp Sensors

AGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7.

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

General Purpose ph/orp Sensors

G2 Industrial Grade Meters

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Conductivity. Inductive Conductivity Sensors. Features and Benefits DATA SHEET. Wide Measuring Range. Low-maintenance Design. Complete Digital System

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

Analytical Instruments Two-Electrode Conductivity Sensors

JUMO ecotrans Lf 01/02

Digital ph transmitter

SIGNET 2750 ph/orp Sensor ENGLISH

ortable ph, Conductivity & DO2 Meters

Insertion/Submersion Flow Through Sensor

MEASUREMENT AND INSTRUMENTATION FLS

Signet 2551 Magmeter Flow Sensor

Control and automatic dosing

Electromagnetic Flowmeters. Product Overview.

Dissolved Oxygen, ph, and Conductivity

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

2015 CONTROLLER PRICE LIST Products / Spare Parts / Accessories

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Signet V(D) to V(D) PVDF Conductivity Electrodes

flow x3 flow monitoring

SOLENOID DRIVEN DOSING PUMPS MX series

Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

Royce Total Suspended Solids Systems. Water & Wastewater

Direct Automation Trade Price List Process Controls Sensors 1

PISTON STYLE GAUGE. Mid-West Instrument

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Signet 4150 Turbidimeter

Instrument Enclosure Assemblies

Appendix. Clearance. Skewed profiles. Application Schematics

Product Specifications

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

Environmental/Analytical LabCivil Engineering Lab Equipment

PSF50 Paddle flow switch

Metso Conductivity for sensor series 9400 and 9500

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Signet 515 Rotor-X Paddlewheel Flow Sensors

TX 115/215 Hot-tap Insertion Turbine Instructions

Automation Made Easy 2013 Signet Measurement and Control Product Catalog

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

TX115/215 Hot-tap Insertion Turbine Instructions

ABB MEASUREMENT & ANALYTICS DATA SHEET. TBX5 ph, Redox (ORP) sensors with diagnostics

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Low Cost Submersion and In-Line ph Electrodes

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

ELPRO Lepenik & Co. d.o.o., Ob gozdu 7c, Rogoza, 2204 Miklavž na Dravskem polju, Slovenija tel:

SIGNET 3719 ph/orp Wet-Tap

SmartBob II SBR.1 A M1 H X X XX. Base. Mounting Plate. Cable. Heater. Probe

OD DISSOLVED OXYGEN METER

Low Profile Insertion Vortex

OD DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL

Product Specifications

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0

PN October Liquid Division. Mounting Solutions

Industrial Meter Catalog

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

Transcription:

2018 AquaMetrix Price List (Rev 2.0/ effective August 2018) AquaMetrix products are manufactured 100 School Street Andover, MA 01810 tel 978-749-9949 toll free 855-747-7623 (855-pHProbe) fax 978-749-9961 www.wateranalytics.net

New in 2018 Price Book Unless otherwise noted, the standard lead time is two weeks or less Special order product lead times vary, may be over standard lead times Express ship program: most popular products are shipped within 24 hours Look for this logo. Hr 24 Shipping It means we stock the most common configuration of the poduct and we will ship it within 24 hours ARO. Look for the highlighted product options as shown in blue. Electronics Standard 5-wire sensor 60 Two wire transmitter, 4-20 ma output $100 65 Dual output transmitter ph/orp and Temperature (R8 only) $200 T65 A $100 minimum order quantity enables eligibility for partner discount New application and conductivity cell constant charts on page 17 For options marked contact a representative for lead times

Contents AM-2250 Single Input, Multi-Parameter Controller 4 AM-2251 Single Input, Multi-Parameter Controller AM-2250TX Single Input, Multi-Parameter Transmitter AM-2300 Multi-Input Universal Controller 5 60 and 65 Series Differential ph or ORP Sensors 6 500 Series Combination ph or ORP Sensors 7 AS Series CPVC Conductivity Sensors 8 AM Series Stainless Steel Conductivity Sensors 9 ES-5 Series Toroidal Conductivity Sensor 10 AM-ES1 Toroidal Conductivity Sensor AM-ODO Analog Output Optical Dissolved Oxygen Sensor 11 AM-CDO Series Dissolved Oxygen Sensor AM-FCL Direct Output Free Chlorine Sensor 12 AM-LL Contacting Liquid Level Controller 13 AM-TBR Turbidity Sensor Seametrics Flow Sensors 14 Price and Materials Matrix for Seametrics Sensors and Mountings 15 Appendix A Calibration Standards 16 GLI (Hach) Replacement Sensors Sensor Application Chart 17 Controller Compatability Chart Cell Constant Refernce Chart Appendix B AquaMetrix Product Tree 18 3

AM-2250 Single Input, Multi-Parameter Controller ph ORP Conductivity Flow Highly visible back-lit LCD display Three control relays for rising or falling processes, in-range alarms Two 4-20 ma outputs with range scaling PID Control Universal mounting hardware provided for surface and panel mounting NEMA 4X / IP68 waterproof enclosure Compatible with AquaMetrix 60-series differential ph/orp sensors, 500-series combination ph/orp sensors, AS-series and AM-series conductivity cells, and most pulse/frequency flow sensors. Two year limited warranty AM-2250 Hr 24 Shipping Analyzers/Transmitters AM-2251 Single Input, Multi-Parameter Controller D.O. Toroidal Conductivity ph ORP Highly visible back-lit LCD display Three control relays for rising or falling processes, in-range alarms Two 4-20 ma outputs with range scaling PID Control Universal mounting hardware provided for surface and panel mountin NEMA 4X / IP68 waterproof enclosure Compatible with AquaMetrix AM-ES1 toroidal sensor, AM-CDO dissolved oxygen sensor, 60-series differential ph/orp sensors, 500-series combination ph/orp sensors Two year limited warranty AM-2250TX Single Input, Multi-Parameter Transmitter ph ORP Conductivity Flow Single 4-20mA output with range scaling PID Control Universal mounting hardware provided for surface and panel mounting Din-mount version available NEMA 4X / IP68 waterproof enclosure Compatible with AquaMetrix 60-series differential ph/orp sensors, 500-series combination ph/orp sensors, AS-series and AM-series conductivity cells, and most pulse/frequency flow sensors. Two year limited warranty AM-2251 Hr 24 Hr 24 Shipping AM-2250TX Shipping Accessories and Mounting Hardware (B) 24VDC-ADP External power supply 24 VDC POWER-CORD Power cord 5 ft 2250-USB-TTL Cable for field firmware upgrade 2250-PIPE-MNT 2250-DIN-MNT Pipe mounting hardware DIN rail mounting hardware 4

2300 Multi-Input Universal Controller Inputs for four 4-20 ma sensors of any kind in any combination: ph, ORP, conductivity, dissolved O 2, Chlorine, and more. Inputs for three flow sensors or contact switches Outputs of four relays (5A-240 V) programmable for any of the inputs Alarm notifications e-mail, text, and/or display for each input 100% web enabled from set-up to data collection to remote viewing, with password protection, and SSL encryption Perform differential measurement from two analog inputs Data logging downloadable from web interface, FTP, or email 1/4 DIN panel mounted enclosure with adapter for wall mounting Three levels of security to control appropriate access for personnel ModBus via TCP/IP One year limited warranty 24 AM-2300-0 Hr Shipping Inputs Outputs ADD 4X Analog 3X Digital 4X Relays 0 8X Analog 3X Digital 4X Relays 1 4X Analog 3X Digital 4X Relays 4X Analog (4-20mA out) 2 4X Analog 6XDigital 8X Relays 3 4X Analog 3X Digital 10x Relays 4 8X Analog 6X Relays 5 4X Analog 7X Digital 6X Relays 6 8X Analog 12X Relays 8 Accessories and Mounting Hardware (B) 2300-WALL-ENCL NEMA 4X Enclosure for wall mounting, including mounting hardware and pre-drilled conduit holes 2300 CARD4-20 IN Expansion card with additional 4-20 IN 2300 CARD4-20 OUT Expansion card with additional 4-20 out 2300 CARD RELAY Expansion card with additional relays 2300 CARD PULSE Expansion card with additional pulse inputs 2300 CARD 7DIG Expansion card with additional digital inputs 2300 CARD 12REL Expansion card with additional relays 2300 Demo Kit For Distributors Only Consists of 2300, ES-5 conductivity sensor, P65R8 ph sensor, Tenda wireless router. Packed in a compact, durable carrying case. AquaMetrix provides custom configuration of any 2300 with sensors at a nominal charge.configured 2300 s arrive at the customer site ready to work out of the box. Call for pricing options. 5

60 and 65 Series Differential ph or ORP Sensors ph / ORP Accurate differential measurement Replaceable salt bridge Flow through or fully submersible installation Temperature compensation device in all sensors Compatabile with HACH/GLI sensors (see page 16) Two year limited warranty Application ph ORP Electronics Standard 5-wire sensor 60 Two wire transmitter, 4-20 ma output 65 Dual output transmitter ph/orp and Temperature (R8 only) Body Type Fixed insertion, 1.5 NPT threaded ends, Ryton Fixed insertion, 1.0 NPT threaded ends, Ryton R5-series sensor replaces 1 NPT CPVC C5-series Hot Tap insertion for AM-HTC-7, CPVC Enhanced Performance Options (only if required) Standard electrode Hardened glass electrode for ph sensors (R8, C7 only) Flat faced glass electrode for ph sensors (R8, C7 only) Antimony electrode for ph sensors (R8 only) For up to 5% HF-acid applications. Because of the corrosive nature of HF this probe is not covered the Aquametrix 2 year warranty. Gold electrodes for ORP sensors (R8, C7 only) Custom Cable Length P R T65 Standard 15 ft (4.5m) cable - Ships in 24 hours 015 Custom cable $2/ft applies for the entire cable length. Maximum cable length is 2000 ft Hr 24 R8 R5 C7 H F A G XXX Shipping P 60 R8-015 Accessories and Mounting Hardware (B) AM-SBK-8 AM-SBK-567 AM-SBK-R5 AM-SFL-8 / AM-SFL-5 AM-HTC-7 AM-ARM-8 / AM-ARM-5 AM-JET-8 / AM-JET-5 AM-PTR-8 / AM-PTR-5 AM-TEE-8 / AM-TEE-5 AM-CFT-R5 AM-JB1 AM-CBL60/ AM-CBL65 Salt bridge kit (3 pack) for -R8 series sensors Salt bridge kit (3 pack) for -C6/7 series sensors Salt bridge kit (3 pack) for R5-series sensors 2 Sanitary flange for -8 and -5 series sensors CPVC hot tap ball valve assembly for C7-series sensors Submersion hardware for tank mounting for -8 and -5 series sensors Jet Cleaner for -8 and -5 series sensors Electrode protector for -8 and -5 series sensors 2 Union Tee with adapter for -8 and -5 series sensors Compression fitting for R5 sensor Junction box with integrated terminal strip Extension cable for 60-series or 65-series sensors 6

500 Series - Combination ph or ORP Sensors Double Junction (Ceramic/Pellon) electrodes Temperature compensation device Flow through or submersible installation Rugged CPVC outer shell One year limited warranty Hr 24 Shipping P 575 T1-015 Application ph ORP Body Type 1 MNPT threaded ends, fixed insertion 575 3/4 MNPT CPVC compression fitting, variable insertion 585 Temperature Compensation and Electrode Options PT1000RTD - standard for all 500-series sensors Other temperature devices are available as a special order: 300NTC (T2), 3000NTC (T3), PT100RTD (T4) HF resistant ph electrode (up to 2%) glass with ATC 1 PT1000RTD(HF1), 300NTC(HF2), 3K NTC(HF3), PT100RTD(HF4) Antimony electrode (up to 5% HF resistant) (ph only) Single Junction, no ATC device 1 Cable Option Standard tin-prepped wires BNC connector for ph or ORP Cable Length P R T1 TX HFX HFA BNC Standard 15 ft (4.5m) cable - Ships in 24 hours 015 Custom cable $2/ft applies for the entire cable length. Maximum cable length is 50 ft XXX ph / ORP 1 Because of the extreme corrosive nature of HF this sensor is not covered the one year warranty for combination probes. Accessories and Mounting Hardware (B) AM-500-BNC AM-BT1 AM-SFL-5 AM-ARM-5 AM-JET-5 AM-PTR-5 AM-TEE-5 AM-JB1 AM-TEE-AS AM-CCF-AS AM-SCF-AS Tinned wire to BNC adapter 4-20 ma blind transmitter for ph or ORP sensors with ATC PT1000RTD 2 Sanitary flange for 575 sensors Submersion hardware for tank mounting for 575 sensors Jet Cleaner for 575 sensors Electrode protector for 575 sensors 2 Union Tee with adapter for 575 sensors Junction box with integrated terminal strip 1 Union Tee with 3/4 fitting for 585 sensors CPVC 3/4 compression fitting for 585 sensors 316SS 3/4 compression fitting for 585 sensors 7

AS Series - CPVC Conductivity Sensors Aqua High temp epoxy encapsulated CPVC shell 24 Metrix Hr Shipping SS electrode for general application and Graphite for corrosive 3/4 NPT variable insertion Flow through or submersible installation Temperature compensation device Multiple cell constants are available (See page 17 for conductivity ranges) Two year limited warranty AS M 1 P 1-015 Electrode 316 Stainless Steel M Impregnated Graphite Cell Constant G Cell constant 0.01 (0.2-10uS/cm) 001 Conductivity Cell constant 0.1 (10-500uS/cm) 01 Cell constant 1.0 (100-5,000uS/cm) 1 Cell constant 10 (Graphite only) (1-50mS/cm) 10 Cell constant 50 (Graphite only) (5-250mS/cm) 50 Sensor Mounting Options 3/4 MNPT CPVC compression fitting P 3/4 MNPT SS compression fitting S Extended length sensor for use with hot tap ball valve AM-HTC-AS Temperature Compensation PT1000RTD Standard electrode 1 Other temperature devices are available as a special order: 300NTC (2), 3000NTC (3), PT100RTD (4) Cable Length Standard 15 ft (4.5m) cable - Ships in 24 hours 015 Custom cable $2/ft applies for the entire cable length. Maximum cable length is 50 ft HT X XXX Accessories and Mounting Hardware (B) AM-HTC-AS AM-ARM-AS AM-SFL-AS AM-CBLAS AM-JB1 AM-TEE-AS AM-CCF-AS AM-SCF-AS CPVC hot tap ball valve assembly, 3/4 FNPT Submersion hardware for tank mounting for AS series sensors 2 Flange for AS sensors Extension cable for AS sensors Junction box with integrated terminal strip 1 Union Tee with 3/4 adapter for AS sensors CPVC 3/4 compression fitting for AS sensors 316SS 3/4 compression fitting for AS sensors 8

AM Series - Stainless Steel Conductivity Sensor 316 SS sensor for high temp and pressure applications Variable insertion 1/2 or 3/4 NPT process connection Flow through or submersible installation Temperature compensation device Multiple cell constants are available (See page 17 for conductivity ranges) One year limited warranty AM12 1 K 1-015 Sensor type Stainless steel 1/2 sensor Stainless steel 3/4 sensor Stainless steel 3/4 sensor with Stainless Steel fitting for boiler applications Cell Constant AM12 AM34 AMB34 Cell constant 0.01 (0.2-10uS/cm) 001 Cell constant 0.1 (10-500uS/cm) 01 Cell constant 1 (100-5,000uS/cm) 1 Cell constant 10 (only AM12, AM34) (1-50mS/cm) 10 Cell constant 50 (only AM34) (5-250mS/cm) 50 Sensor Mounting Options KYNAR compression fitting 316SS compression fitting Extended length sensor for use with hot tap ball valve Temperature Compensation Device PT1000RTD Temperature Device 1 Other Temperature Devices are available as a special order: 300NTC (2), 3000NTC (3), PT100RTD (4) Cable Length Standard 15 ft (4.5m) cable 015 Custom cable $2/ft applies for the entire cable length. Max cable length should not exceed 50 ft K S HT X XXX Conductivity Accessories Mounting Hardware (B) AM-HTC-AM12 AM-HTC-AM34 AM-ARM-AS AM-SFL-AS AM-CBL-AS AM-JB1 AM-TEE-AS AM-KCF-AM12 /AM34 AM-SCF-AM12 /AM34 316SS hot tap ball valve assembly for AM12-HT sensors 316SS hot tap ball valve assembly for AM34-HT sensors Submersion hardware for tank mounting for AM34 series sensors 2 Sanitary flange for AM34 sensors Extension cable for AM sensors Junction box with integrated terminal strip 1 Union Tee with 3/4 adapter for AM34 series sensors Kynar compression fitting for AM12 amd AM34 series sensors 316SS compression fitting for AM12 and AM34 series sensors 9

ES-5 Series Toroidal Conductivity Sensors ES-5 4-20 ma isolated output Note: The ES-5 is compatible with CPVC outer shell the AM-2300 Controller 1-1/2 MNPT threaded ends Temperature compensation device Multiple cell constants are available (See page 17 for conductivity ranges) One year limited warranty ES-5- C-1-015 Conductivity Effective Cell Constant Range ADD 0.2 to 10 ms/cm C1 2 to 100 ms/cm C2 20 to 1000 ms/cm C3 Cable Length Standard 15 ft (4.5m) cable 015 Custom cable $4/ft applies for the entire cable length. Maximum cable length is 2000 ft AM-ES1 Toroidal Conductivity Sensors XXX AM-ES1 Polypropylene body Note: The AM-ES1 is compatible with 3/4 NPT thread the AM-2251 Controller Temperature compensation device Replaces GLI 3725E2T sensor Wide measuring range. See chart on pg.17 for full range One year limited warranty AM-ES1-015 Cable Length ADD Standard 15 ft (4.5m) cable 015 Custom cable $2/ft applies for the entire cable length. Maximum cable length is 50 ft XXX Accessories Mounting Hardware (B) AM-CBL-60 AM-JB1 AM-TEE-ES Extension cable for AM-ES1 sensors Junction box with integrated terminal strip 2 Union Tee with adapter 10

AM-ODO Direct Output Optical Dissolved Oxygen Sensor PVC construction Dual output (%sat and mg/l) or temp and mg/l Direct output via 4-20 ma or 0-5V Salt water compensation with toggle Only 1 replaceable part (sensor cap) Not affected CO 2 or H 2 S One year limited warranty AM-ODO - - 015 Options Temperature and mg/l Option ADD T Cable Length ADD Standard 15 ft (4.5m) cable 015 Custom cable $4/ft applies for the entire cable length. Maximum cable length is 1000ft Accessories (B) AM-ODO-CAP AM-ODO-MPR AM-ODO-UIB AM-ODO-T-UIB Replacement membrane cap Metal protector AM-CDO Amperometric Dissolved Oxygen Sensor Polarographic (Clark) Measuring Technique Wide dynamic range: 0-250% saturation Transmission up to 2000 ft (600 m) 15 ft (4.5 m) cable Compatible with AM-2251 and 2200D controller Replaces AM-P91 sensor One year limited warranty Converter Box for % sat and mg/l Converter Box for temperature and mg/l Note: The AM-CDO is compatible with the AM-2251 Controller XXX AM-CDO - 015 Dissolved Oxygen (D.O.) Cable Length ADD Standard 15 ft (4.5m) cable 015 Custom cable $2/ft applies for the entire cable length. Max cable length is 2000 ft XXX Accessories Mounting Hardware (B) New AM-ARM-5 AM-JB1 AM-CBL60 AM-TEE-5 AM-CDO-KIT AM-CDO-CAP Submersion hardware for tank mounting for C91 sensors Junction box with integrated terminal strip Extension cable for C91 sensors 2 Union Tee with adapter Refill solution 30mL, membrane, and polishing strips Replacement Membrane Cap 11

AM-FCL Direct Output Free Chlorine Sensor 2-Electrode amperometric design Loop powered direct 4-20mA output Automatic temperature compensation Inexpensive replaceable membrane and electrolyte One year limited warranty AM-FCL- 02-015 Free Chlorine Concentration Range 0-2 ppm 02 0-5 ppm 05 0-10 ppm 10 Cable Length ADD Standard 15ft (4.5m) cable 015 Custom cable $4/ft applies for the entire cable length. Maximum cable XXX length is 1000ft Due to extreme flow dependancy flow cell and flow meter are highly recommended Chlorine Accessories (B) AM-FCL-FC AM-FCL-FM AM-FCL-RE AM-FCL-MC Flow Cell Flow Meter Electrolyte Membrane Cap 12

AM-LL Contacting Liquid Level Controllers AC based conductivity SPDT (single pole double throw) relay Built in sensitivity adjustment (timer for LL3) Current and voltage limited NEMA1 enclosure Two year limited warranty AM- LL 3-120 Configuration Options ADD 10 kω max sensitivity, double pole, double throw, relay timer adjustment 3 10 kω sensitivity, single pole, double throw 4 10 kω sensitivity, single pole, double throw plus auxiliary normally open contacts 1MΩ sensitivity, single pole, double throw plus auxiliary normally open contacts Power Options 120VAC 120 240VAC 240 7 7H AM-TBR Turbidity Sensor Nephilometric measurement Loop powered direct 4-20mA output (IR VERSION) Optional constant pressure flow cell Automatic temperature compensation One year limited warranty AM-TBR-IR 40 Level Light Source White Light (USEPA180.1) Infrared (ISO 7027) WL IR Turbidity Range 0-4 NTU 4 0-40 NTU 40 0-400 NTU 400 Accessories (B) AM-TBR-FC40 AM-TBR-FC400 AM-TBR-TEE Flow Cell for 0-4 and 0-40 range sensors Flow Cell for 0-400 range sensors 2 Union Tee for Turbidity Sensor 13

Flow Seametrics Flow Sensors Pulsed output works with AM-2250 controller For pipe diameters of 3/8 to 48 IP sensor with Kynar impeller, ru jewel bearing and tungsten carbide shaft EX sensor with no moving parts and superior low-flow perfomance SPX sensor with FNPT threads for very low minimum flow rates 18 (5.5m) standard cable One year limited warranty Sensor Type and Style Impeller sensor ( 1/2-3 ) fixed insertion Impeller sensor ( 4-8 ) fixed insertion Impeller sensor ( 3-12 ) variable insertion Impeller sensor ( 12-40 ) variable insertion Impeller sensor (3-12 ) hot-tap insertion Impeller sensor (12-40 ) hot-tap insertion Magmeter sensor ( 1-3 ) fixed insertion Magmeter sensor ( 4-10 ) fixed insertion Magmeter sensor ( 12 ) fixed insertion Magmeter sensor (3-10 ) variable insertion Magmeter sensor (10-48 ) variable insertion Magmeter sensor (3-10 ) hot-tap insertion Magmeter sensor (10-48 ) hot-tap insertion Sensor Material PVC Stainless Steel Brass Mounting Type (only if required) none Tee Saddle Weldolet Mounting Material PVC Carbon Steel (Iron for Saddle) Stainless Steel Brass/Bronze Pipe Dimension Code See page 17 for three/four digit code Sensor Type and Style IP810 IP820 IP110 IP210 IP150 IP250 EX810 EX820 EX830 EX110 EX210 EX150 EX250 P S B T S W P C S B -XXX In-line type with 3/8 FNPT 038 In-line type with 1/2 FNPT 050 In-line type with 3/4 FNPT 075 In-line type with 1 FNPT 100 Price Category (C) IP810 P T P - 200 Base Price (C) $525 SPX - 100 14

Price and Materials Matrix for Seametrics Sensors and Mountings The many possible combinations of fitting type, size and material make the pricing of the sensors and fittings more involved than the simple menu options listed for other sensors. The chart below makes the fitting selection process simple. Replacement parts and accessories are available upon request. Please contact your representative for details. Sensor price category (C) Impeller type IP810 PVC (P) Stainless Steel (S) Brass (B) Magmeter type EX810 PVC (P) Stainless Steel (S) Brass (B) IP820 EX820 IP110 EX830 IP210 EX110 IP150 EX210 IP250 EX150 EX250 Mounting price category (C) Fixed Insertion IP810 IP820 n/a n/a EX810 EX820 EX830 Pipe Diameter 1/2 3/4 1 1-1/2 2 3 4 6 8 10 12 Dimension Code -050-075 -100-150 -200-300 -400-600 -800-1000 -1200 PVC (P) Flow Tee Bronze (B) Carbon Steel (C) SS (S) Saddle Weldolet PVC (P) Ductile Iron (S) Bronze (B) Brass (B) Carbon Steel (C) SS (S) Variable Insertion and Hot-Tap IP110/IP150 EX110/EX150 IP210/IP250 EX210/EX250 Pipe Diameter 3 4 6 8 10 12 14 16 18 20 22 24 Dimension Code -300-400 -600-800 -1000-1200 -1400-1600 -1800-2000 -2200-2400 Saddle Iron (C) 15

Appendix A ph Calibration Standards (A) AM-PH4-1P AM-PH4-1G AM-PH7-1P AM-PH7-1G AM-PH10-1P AM-PH10-1G ph 4 buffer solution, 500mL (1 pint) ph 4 buffer solution, 4L (1 gallon) ph 7 buffer solution, 500mL (1 pint) ph 7 buffer solution, 4L (1 gallon) ph 10 buffer solution, 500mL (1 pint) ph 10 buffer solution, 4L (1 gallon) Calibration ORP Calibration Standards (A) AM-R200-1P AM-R200-1G AM-R600-1P AM-R600-1G 200 mv ORP buffer solution, 500 ml (1 pint) 200 mv ORP buffer solution, 4L (1 gallon) 600 mv ORP buffer solution, 500 ml (1 pint) 600 mv ORP buffer solution, 4 L (1 gallon) Conductivity Calibration Standards (A) AM-C050U-1P AM-C100U-1P AM-C500U-1P AM-C001M-1P AM-C005M-1P AM-C010M-1P AM-CXXXX-1P AM-CXXXX-1G 50 µs (.05 ms) calibration solution, 500 ml (1 pint) 100 µs (.1 ms) calibration solution, 500mL (1 pint) 500 µs (0.5mS) calibration solution, 500mL (1 pint) 1000 µs (1mS) calibration solution, 500mL (1 pint) 5000 µs (5mS) calibration solution, 500mL (1 pint) 10,000 µs (10mS) calibration solution, 500mL (1 pint) Custom conductivity calibration solution, 500mL (1 pint) Custom conductivity calibration solution, 4L (1 gallon) Controllers that are compatible with AquaMetrix sensors P60 series sensors will work with AquaMetrix 2250/2250TX, Shark-120/TX, Hach SC100, Hach SC200, GLI53 and many others P65 and PT65 series sensors will work with AquaMetrix 2300, Hach SC200 and any PLC with analog inputs GLI (Hach) Replacement Sensors GLI Part Number Aquametrix Part Number GLI Part Number Aquametrix Part Number 6022P0 P60R8-015 DPD1P1 P60R5-015 6028P0 P60R8-015 DPD2P1 P60R5-015 6422P0 P65R8-015 DRD1P5 R60R5-015 6428P0 P65R8-015 DRD1R6 R60R5-015 6052P0 P60R8-015 PD1P1 P65R5-015 6058P0 P60R8-015 PD1R1 P65R5-015 6458P0 P65R8-015 RD1R5 R65R5-015 16

Appendix A (Continued) Sensor Applications Application ph ORP Conductivity D.O. Level Flow Chlorine Wastewater Filtration HVAC Pump/Lift Station Tank Monitoring Aquaculture Food & Beverage Controller Compatability Chart Sensor AM-2250 AM-2250TX AM-2251 AM-2300 60 Series Sensors 65 Series Sensors 500 Series Sensors AS Series Sensors AM Series Sensors ES-5 Toroidal Sensors AM-ES1 Toroidal Sensor AM-ODO Sensors AM-CDO Sensors AM-FCL Chlorine Sensor AM-TBR Turbidity Sensor Seametrics Flow Sensors Conductivity Cell Constant Chart Conductivity measurement range 5-500,000 µs/cm Wide Range Toroidal (AM-ES1) Toroidal (ES5C1) Toroidal (ES5C2) Toroidal (ES5C3) Cell Constant=0.01 (ASM001) Cell Constant=50 (ASG50) Cell Constant =10 (ASG10) Cell Constant=1 (ASM1) Cell Constant=0.1 (ASM01) 0.1 1 10 100 1,000 10,000 100,000 1,000,000 µs/cm (Log scale) 17

Appendix B Probes / Sensors Controllers / Transmitters Temperature Flow Dissolved Oxygen Chlorine Turbidity Level AM-2300 Cloud Based UI (LAN or Cellular) UniFi Multi Input Controller AM-2300 Contacting Controller AM-LL Series NTU 4-20 ma AM-TBR Free Chlorine 4-20 ma AM-FCL Luminescent 4-20 ma AM-ODO Polarographic (Clark) AM-CDO Variable Insertion 110/210 Series Fixed Insertion 800 Series Stainless Steel 4-20 ma AM-T 2250-Series ph / ORP Conductivity Contacting Inductive Combination Differential Single Input Controllers Single Input Transmitter ph/orp/flow/ Conductivity AM-2250TX ph/orp/do/ Conductivity AM-2251 ph/orp/flow/ Conductivity AM-2250 Hot Tap Insertion C7 Series Fixed Insertion R5 Series Fixed Insertion R8 Series Variable Insertion 585 Series Fixed Insertion 575 Series CPVC 4-20mA AM-ES5 Wide Range AM-ES1 Stainless Steel AM Series CPVC AS Series Solutions for the Most Challenging Environments 18

100 School Street Andover, MA 01810 978-749-9949 fax 978-749-9961 www.wateranalytics.net