Typical Gas Chromatographic System

Similar documents
GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

Practical Steps in GC Troubleshooting

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Using the PSD for Backflushing on the Agilent 8890 GC System

Method Development for Capillary GC Systems. Slide 1

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer

GC Inlets. An Overview. Simon Jones GC Applications Engineer

C2, C3, C4 Monomer Analysis

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Setting up SilFlow for BackFlush in your GC

Agilent and ASTM. Update on Recent Activities. Page 1

Agilent Multimode Inlet for Gas Chromatography

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut

Technical Procedure for Gas Chromatography (GC-FID)

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Agilent G2855A Deans Switching System

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx

ASTM D 6730 Detailed Hydrocarbon Analysis

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Beverage Grade Carbon Dioxide

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Application Note. Abstract. Authors. Environmental Analysis

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

MET-Biodiesel Capillary GC Columns

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities

GC Method Compliance and Large Valve Oven Application

Choose for Your Instrument

Techniques for Improving the Reproducibility of GC Analysis

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

260 Solvent Vapor Exit Accessory

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

Agilent 6890 Gas Chromatograph

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Operation and Applications of Differential Flow Modulation

Application. Gas Chromatography June 1995

Liquid Injection Techniques in GC and GC-MS

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

DANI Transformer Oil Gas Analyzer

Forensic Blood Alcohol Determination with the Intuvo 9000 GC

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

GC Injector Liners. Bruker Varian Agilent (HP) Perkin Elmer Finnigan. Phone: Page 4

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Installing the 6850 Direct Valve Column Connector Kit

GC Analysis of PCBs in Fish Oil by Direct Injection Without Any Sample Cleanup. Philip L. Wylie, Ph.D. Sr. Applications Chemist Agilent Technologies

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

RIVA 2014 COMPLETE YOUR AGILENT TOUR. Better Connections with Agilent. Ken Lynam CSD R&D/Applications Chemist, Wilmington, DE USA.

Analysis of Petroleum Fractions by ASTM D2887

performance productivity reliability

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Agilent Multimode Inlet

GCMS-QP2010 Series. Consumables. Shimadzu Gas Chromatograph/Mass Spectrometer

CP-3800 GAS CHROMATOGRAPH

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

6890 Installing ¼ Glass Columns

Agilent s GC Analyzer Solutions: Introduction to the Controlled Substances Analyzer

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

New Specialized GC Columns for the Petroleum Industry -Integrated Particle Trap PLOTs -DB-Sulfur SCD

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

From Helium to Hydrogen: GC-MS Case Study on SVOCs in Water

Agilent 7890 Series Gas Chromatograph

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns

URB '-carbamoylbiphenyl-3-yl cyclohexylcarbamate. DEA Reference Material Collection. Form Chemical Formula Molecular Weight Melting Point ( o C)

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

1310 Inlets. 1 of 36. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

S-PRO 3200 GC System for Sulfur Analysis

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

AZ Chrom s.r.o.

Split and Splitless Injection in Capillary Gas Chromatography

Transcription:

Page 72

Air Hydrogen Carrier Gas Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer Cylinders or Generators Flow Controller Column Recorder/ Integrator Picking the appropriate stationary phase and optimum dimensions for the column will give the greatest resolution in the shortest analysis time. Page 73

Peak Fronting Shark Fin Shaped or Just Slight COLUMN (contaminated) -Overload (More pronounced with large solute and phase polarity differences) INJECTOR -Poor efficiency (flow/temp) -Column installation -Compound very soluble in injection solvent (need retention gap) -Mixed sample solvent OTHER -Co-elution -Breakdown Page 74

Effect of Sample Overload on Retention Time and Peak Shape 1400 ng 7 ng 8 9 10 11 min Page 75

Retention Time Shift 1.75 INJECTOR 4.50 2.00 4.75 -Change in injection solvent -Large change in sample concentration FLOW 3.00 3.25 -Leak in the septum -Change in gas velocity 2.75 COLUMN -Contamination 5.50 -Damaged stationary phase -Loss of stationary phase 4.00 -Change in temperature Page 76

Constant Pressure vs Constant Flow Retention C20 C10 C30 C40 C20 C10 C30 C40 Under constant pressure conditions, flow decreases as temperature increases. (viscosity of a gas increases as temperature increases) Page 77

Gas Viscosity vs Temperature J.V. Hinshaw, Column Connections, LCGC Asia Pacific, 12(2), 1100 (2009). Page 78

Retention Times Shift 4-5 sec During the First 10 Runs Overlay of first 10 runs Norm. 14000 12000 10000 8000 6000 4000 2000 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6 6.1 6.2 min Page 79

GC-FID Chromatogram of Fish Oil 1-µL splitless injection of 10% fish oil GC oven was held at 290 o C for 30 min at the end of the run. Response_ se_ 0000 0000 0000 0000 0000 S ig n a l: F I S H O I L H 2. D \ F I D 1 A. C H 380000 360000 S i g n a l : F I S H O I L H 2. D \ F I D 1 A. C H 340000 320000 300000 280000 260000 240000 220000 200000 180000 0000 0000 0000 0000 Time 160000 140000 20.00 22.00 24.00 26.00 28.00 30.00 32.00 34.00 36.00 38.00 40.00 Enlarged 0000 0000 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 Page 80

Get High M.W. Fish Oil Off the Column After Every Run = No More Shifting Retention Norm. Retention Time Precision with Backflushing Overlay of 10 Runs 16000 14000 12000 10000 8000 6000 4000 2000 0 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6 6.1 min Page 81

Purged Capillary Flow Devices 2-Way Splitter with Makeup 3-Way Splitter with Makeup Deans Switch Purged Union (most recent) All Purged Capillary Flow Devices are Capable of Backflushing Page 82

Backflush with Purged Union or Any Purged Capillary Flow Technology Device Split Vent Trap During GC Run Aux EPC 4 psi Inlet MSD 25 psi Split Vent Trap Column After GC Run Purged CFT Device Aux EPC 80 psi Inlet MSD 1 psi Column Purged CFT Device performance turbo recommended Page 83

Milk Extract It took additional 33 mins and column to 320 o C to remove these high boilers. Run stopped at 42 min and backflushed at 280 o C for 7 mins. Blank run after backflushing showing the column was clean. 5 10 15 20 25 30 35 40 45 50 55 60 65 70 min Page 84

Post-Column Backflush Injector Detector Transfer Line Column Purged Ultimate Union

Mid-Column Backflush Injector Detector Column Front Half Back Half Purged Ultimate Union

Pre-Column Backflush Injector Detector Pre-Column Column Purged Ultimate Union

Without Backflush: A Serious Problem Abundance 4.6e+07 4.4e+07 4.2e+07 4e+07 3.8e+07 3.6e+07 3.4e+07 3.2e+07 3e+07 2.8e+07 2.6e+07 2.4e+07 2.2e+07 2e+07 1.8e+07 1.6e+07 1.4e+07 1.2e+07 1e+07 8000000 6000000 4000000 2000000 0 Time A: TIC: lettuce_blank.d\data.ms B: TIC: lettuce_blank3.d\data.ms Data provided by MSD user in Almeria, Spain After only 3 10-µL injections, the background is significantly higher (increase chemical noise is every spectrum) 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 B A Overlay of two chromatograms of a blank extract injected BEFORE (A) and AFTER (B) three injections without backflush Page 88

With Backflush: No Increased Background (Less Spectral Noise) and Consistent Retention Times Abundance 4.6e+07 4.4e+07 4.2e+07 4e+07 3.8e+07 3.6e+07 3.4e+07 3.2e+07 3e+07 2.8e+07 2.6e+07 2.4e+07 2.2e+07 2e+07 1.8e+07 1.6e+07 1.4e+07 1.2e+07 1e+07 8000000 6000000 4000000 2000000 0 Time TIC: lettuce_10_ppb.d\data.ms TIC: lettuce_100_ppb.d\data.ms TIC: lettuce_5_ppb.d\data.ms Data provided by user in Almeria, Spain Stable retention times and baseline... less chemical noise 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Overlay of three chromatograms of lettuce extract run with 2 min of back flush Page 89

Loss of Resolution Separation Peak Width Resolution is a function of separation and peak width Page 90

Loss of Resolution - Separation Decrease COLUMN -Different column temperature -Contamination (more phase?) Separation -Matrix components co-eluting -Different column phase? Peak Width Page 91

Loss of Resolution - Peak Broadening FLOW -Change in carrier gas velocity -Make-up gas Separation COLUMN -Contamination -Phase degradation Peak Width INJECTOR (efficiency) -Settings, Liner, Installation, etc. Page 92

Air Hydrogen Carrier Gas Typical Gas Chromatographic System Gas settings have to be correct Mol-Sieve Traps Fixed Restrictors Makeup gas needed for some Contamination hurts sensitivity Regulators Injection Port Detector Electrometer Flow Controller Recorder/ Integrator Column Cylinders or Generators Page 93

Baseline Disturbances Sudden Changes, Wandering, or Drifting WANDER COLUMN or DETECTOR -Not fully conditioned or stabilized (electronics) -Contamination FLOW -Changes in carrier and/or detector gas flows -Valves switching, leaks DRIFT Page 94

Noisy Baseline MILD SEVERE FLOW -Contaminated gas -Incorrect detector settings COLUMN -Bleed if at high temperature -In detector flame (poor installation) DETECTOR -Air leak - ECD, TCD -Electronics malfunction Page 95

Column Bleed Affected by Dimensions and Phase Type 1.3e4 1.2e4 1.1e4 1.0e4 9000 8000 DB-624 30M x.53mm I.D., 3.0µm 24 pa / 260 C 7000 6000 DB-1 30m x.32mm I.D.,.25µm 12 pa / 320 C 0 5 10 15 20 25 Time (min.) Page 96

Mass Spectrum of Phenylmethylpolysiloxane Column Bleed (Normal Background) Mass spectral library search is not always accurate Page 97

Traditional PDMS column- Coking (desensitization) of Reactor Tubes Overlay of before (green) and after 2 x 2 ul neat toluene Injection (red) 1 2 3 SCD: 10% drop in sensitivity 4 1. Hydrogen Sulfide 2. Carbonyl Sulfide 3. Methyl Mercaptan 4. Ethyl Mercaptan FID: No response changes 3 4 Data courtesy of Jim Luong, Ronda Gras, Myron Hawryluk of Dow Chemical Canada Page 98

New DB-Sulfur SCD column Last Three Runs of the day (n=20, 100 ppmv std) SCD 1 2 3 4 1. H2S 2. COS 3. CH3SH 4. C2H5SH 4 FID 40C 3 250C Cool down Data courtesy of Jim Luong, Ronda Gras, Myron Hawryluk of Dow Chemical Canada Page 99

Spiking Baseline DETECTOR -Particles entering the detector -Random: poor connection -Regular: nearby "cycling" equipment (electronics) Page 100

NEW Integrated Particle Trap PLOT Column 2.5 meter integrated particle traps on both ends Compatible with GC/MS and valve switching systems, and Capillary Flow Technology PLOT Very similar selectivity, plates and peak shape to existing Agilent PLOT columns Page 101

The PLOT Column and Integrated Particle Trap Page 102

No spikes at Fixed Gases Analysis on CP-Molsieve 5Å PLOT PT column CP-Molsieve 5Å, 25m 0.53mm,50um (30m total length) Carrier : H2, 3mL/min Oven: : 80 C isothermal Injection: 70 C, split ratio 5:1 Detector: TCD, 250 Sample: 100uL Page 103

Quantitation Problems DETECTOR -Poor stability (electronics) or Baseline disturbances (contamination) -Outside detector's linear range or wrong settings Activity (adsorption) in INJECTOR or COLUMN OTHER INJECTOR -Technique, settings, conditions -Syringe worn -Co-elution -Matrix effects -Sample evaporation leaky vials -Sample decomposition Page 104

Agilent 5975C GC/MS. Page 105

MSD Source Inertness an old problem revisited Inert MSD source increases response of chemically active analytes Page 106

Inert MSD Source Page 107

Mass Spectral Problems No Peaks Ion source cables not connected Bad connections from or to detector HED power supply output cable failure Filaments both blown Other electronics failure Page 108

Mass Spectral Problems Loss of Sensitivity MSD has not reached thermal equilibrium Incorrect tuning - Calibration fluid empty or near empty - Calibration valve malfunctioning Ion source dirty Electron multiplier needs replaced Page 109

Mass Spectral Problems High background Excessive pressure in the analyzer chamber Air leak Contamination Mass Spectral Problems High abundances at m/z 18,28,32 and 44 System recently vented (pumping down) Masses at 14,16 and 19 are indicative of a massive leak Page 110

Common Contaminant Ions. Page 111

But at the End of the Day It s in the Inlet! Do Inlet Maintenance - Trim the Column - Replace the Liner - Replace the Gold Seal - Replace the Syringe - Replace the Split Vent Trap, Split Vent Line - Rinse the Inlet Page 112

Common Care and Maintenance Scheme for GC Columns 1. Bake out the column for no more than 2 hours. 2. Cut off 6-1ft of the inlet end of the column. 3. Cut off more column. (repeat as necessary) Page 113

Cleaning the Split/Splitless Injector Carrier gas flow off Disconnect split vent line Replace split vent trap Injector body GC Off Remove column, reducing nut, gold seal, washer and liner MeCl 2 Ace tone Page 114

Finding the Split Vent Trap Remove cover at Split Vent Page 115

Replacing the Split Vent Trap Finger Tight Knurled Nut G1544-80530 Page 116

Split Vent Trap Changed (Column Bleed?!?) Before After Page 117

Be Careful When Doing Maintenance You may be the CONTAMINATOR! Page 118

Contamination of system by residue on fingers during column installation Column: Carrier: Injector: Detector: Oven: DB-5ms, 30m x 0.25mm, 0.25um H2, 60 cm/sec, constant flow split 1:20, 250 o C FID, 320 o C, N2 makeup gas 40 o C for 0.75 min, 40-325 o C at 20 o C/min, 325 o C for 30 min Red: French Fry Blue: system blank Procedure: (1) Held French fry for 5 seconds. (2) Fingertip was wiped with paper towel to remove as much of the offending material as possible. (3) Lightly touched the part of the column sticking up above the ferrule. (4) Installed column into injector. (5) Set oven temperature to 40 o C. (6) Started oven temperature program as soon as oven reached 40 o C.

Contamination from Liquid Soap Column: Carrier: Injector: Detector: Oven: DB-5ms, 30m x 0.25mm, 0.25um H2, 60 cm/sec, constant flow split 1:20, 250C FID, 320C, N2 makeup gas 40C for 0.75 min, 40-325C at 20C/min, 325C for 30 min Red: Liquid Soap Blue: system blank Procedure: (1) One very small drop of liquid soap placed on one fingertip. (2) Fingertip was wiped with paper towel to remove as much of the offending material as possible. (3) Lightly touched the part of the column sticking up above the ferrule. (4) Installed column into injector. (5) Set oven temperature to 40C. (6) Started oven temperature program as soon as oven reached 40C.

Contamination from Hand Lotion Column: Carrier: Injector: Detector: Oven: DB-5ms, 30m x 0.25mm, 0.25um H2, 60 cm/sec, constant flow split 1:20, 250C FID, 320C, N2 makeup gas 40C for 0.75 min, 40-325C at 20C/min, 325C for 30 min Red: Hand Lotion Blue: system blank Procedure: (1) One very small drop of hand lotion placed on one fingertip. (2) Fingertip was wiped with paper towel to remove as much of the offending material as possible. (3) Lightly touched the part of the column sticking up above the ferrule. (4) Installed column into injector. (5) Set oven temperature to 40C. (6) Started oven temperature program as soon as oven reached 40C.

More and More Touchless Packaging Page 122

Troubleshooting Tools Bleed Profile: baseline problems Inject a non-retained peak: peak shape problems Leak Test: all problems Test mix: all problems Isolate the components: all problems Jumper Tube Test: baseline problems Page 123

Generating a Bleed Profile 1.3e4 1.2e4 Produce when the column is new (for future reference) when there is a baseline problem 1.1e4 1.0e4 9000 8000 7000 6000 0 5 10 Time (min.) 15 20 25 *DB-1 30m x.32mm I.D.,.25µm Temperature program // 40 C, hold 1 min // 20 /min to 320 C, hold 10 min. Page 124

Non-Retained Peak Shapes Used to Check Flowpath Good Installation Improper Installation or Injector Leak Potential problems: Injector or septum leak Too low of a split ratio Liner problem (broken, leaking, misplaced) Column position in injector and detector Page 125

Leak Test - MS Air/Water - Leak Detector Portable, handheld unit only 310g/11oz Fast detection 1 second Audible and visual alerts for 12 gases Minimum detection limit of 0.01 ml/minute for hydrogen and helium Rechargeable NiMH battery with over 5 hours of life Page 126

Ferrule Pre-swaging & MS Interface Installation Tools Ensures proper length of column into the fittings, every time For graphite or metal ferrules Metal ferrule Graphite ferrule G3440-80218 G3440-80217 Page 127

Self-Tightening Column Nuts Innovative spring-driven piston continuously presses against ferrule Less wasted time: No retightening needed after repeated thermal cycles Ease of use: Finger-tight, consistent connections without tools Leak Free = Lower column bleed: Longer column life Video at agilent.com/chem/stnutvideo Page 128

Self-Tightening Column Nuts Page 129

Test Mix Used to determine how good the column is or if the problem is related to the chemical properties of the analytes. TEST TEMPERATURE: 135 C CARRIER GAS: H 2 37.8 cm/sec 1.2 ml/min INJECTION: SPLIT ANALYST: ERIK Max. Bleed 10.0 pa 325 9.0 pa 135 0 5 RETENTION TIME (MIN) Page 130

Test Mixture Components Compounds Hydrocarbons Alcohols FAME s, PAH s Acids Bases Purpose Efficiency Retention Activity Retention Acidic Character Basic Character Page 131

Own Test Mixture More specific Selective detectors Actual concentrations No conditions or instrument changes Page 132

Jumper Tube Test Purpose Helps to locate the source of contamination or noise Isolates GC components Page 133

Jumper Tube Test Isolate the Detector Remove column from the detector Cap detector and turn on Blank run Page 134

Jumper Tube Test Isolation of Detector - Results Detector OK Detector is the problem Page 135

Jumper Tube Test Isolate the Injector Connect the injector and detector - 1-2 meters deactivated fused silica tubing Turn on carrier gas Blank run Page 136

Jumper Tube Test Isolate the Injector - Results Injector OK Injector, lines or carrier gas contaminated Page 137

Jumper Tube Test Isolate the Column Reinstall the column Setup as before Blank Run Page 138

Jumper Tube Test Isolate the Column - Results Problem returns: It s the column Problem gone: Previous leak, solid debris, or installation problem Page 139

Jumper Tube Test Used to Isolate Source of Contamination. Cap off the detector and establish normal gas flows and temperature.. Plot the baseline using a temperature program. If flat.... Connect 1 meter of deactivated tubing between the injector and detector. Plot the baseline using a temperature program. If flat.... Install the column.. Plot the baseline using a temperature program. Page 140

Remember Complete system = Carrier Gas + Injector + Column + Detector + Data System Multiple cause and effect Do not change too many variables at once Page 141

Symptoms and Reasons (Cheat Sheet) *Solution = Get Rid of the Reason Peak Tailing Flow Path or Activity Bonus Peaks In Sample or Back Flash (Carry Over) Split Peaks Injector Problems, Mixed Solvent, Cold Spots Broad Peaks Injection Problems, Temperature/Flow, Solubility Problems No Peaks Wasn t Introduced, Wasn t Detected Response Changes Activity, Injector Discrimination, Detector Problem Peak Fronting Overload or Solubility Mismatch, Injector Problems Shifting Retention Leaks, Column Aging, Contamination or Damage Loss of Resolution Separation Decreasing, Peak Broadening Baseline Disturbances Column Bleed, Contamination, Electronics Noisy or Spiking Baseline Electronics or Contaminated Detector Quantitation Problems Activity, Injector or Detector Problems Page 142

Troubleshooting Resources Online Troubleshooting and Maintenance Videos http://www.chem.agilent.com/en-us/technical-support/instruments-systems/gas- Chromatography/Pages/troubleshootingvideos.aspx GC Troubleshooting Guide http://www.chem.agilent.com/en-us/products-services/instruments-systems/gas- Chromatography/pages/gp6770.aspx Method Translation Software http://www.chem.agilent.com/en-us/technical-support/instruments-systems/gas- Chromatography/utilities/Pages/gcmethodtranslation.aspx Page 143

Agilent Better GC Connections www.agilent.com/chem/bettergcconnections Order the poster View the video

1 (972) 699-6423 (Daron) 1 (214) 883-2260 (Eric) E-mail: gc-column-support@agilent.com Eric.pavlich@agilent.com Daron_Decker@agilent.com Page 145