INSTALLATION & MAINTENANCE MANUAL HBL

Similar documents
LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Motion and Light Sensor Kit LHBAS51

Installation Instructions: Eco SpunBay LED High Bays

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

Specification Sheet for 2D LED Light

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

ASSEMBLY & FITTING INSTRUCTIONS P-LUX3 LED TRI-SENSOR LANTERN

25W LED Cross Bezel Bulkhead Light

10W LED Die Cast Small Rectangle Bulkhead Light

LED CANOPY with j-box

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

INFRESCO-S-4kW X20034 Issue: 7

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

LED emergency exit signage from Channel Safety Systems

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

2 PORT MOTORISED VALVE (28 mm)

18W Round LED Slimline Emergency Light

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

PIL0478 ISSUE 01/ 07/16

Installation Instructions

LED Emergency Luminaires

Operating Instructions

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

2x 10W LED Slimline Floodlight Twin Flood

3000W Dusk to Dawn Light Controller

3 PORT MOTORISED VALVE (22 mm)

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

Installation Instructions

24 Hour Immersion Heater Time Controller

Installation Instructions

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

Mightylite Elite 16W LED Wall Light with PIR

Installation and Maintenance Manual (2014)

3 PORT MOTORISED VALVE (32/38 mm)

Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting,

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

28W WORK LAMP Model: CTL28 Part No:

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

LED Security Wallpack Installation Instruction

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

PROFESSIONAL 270 o PIR MOTION DETECTOR

INSTALLATION INSTRUCTION MANUAL

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

MANUFACTURED IN THE UK

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Measurements are expressed in millimeters.

Operating Instructions. Tronic Dimmer

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

OPERATION & MAINTENANCE INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

LED Twister II. User manual UK Version 1.0

EMERY SKY SUSPENDED LED LUMINAIRE

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

INSTALLATION INSTRUCTION MANUAL

18W Low Energy. instructions. Instructions

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

ASSEMBLY AND INSTALLATION INSTRUCTIONS

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

ECO CFL. with Photocell. Instructions. Model: ECO2DD Model: ECO3DD

LED.Commercial 12W LED DD

OPERATION & MAINTENANCE INSTRUCTIONS

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Technical Data. Dimmer Switches - Push Type 881P/885P 882P 883P 884P

Installation Instructions

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

OPERATION & MAINTENANCE INSTRUCTIONS

UP TO 75% Up to 160Lm/W. UFO LED HIGH BAY 100W to 200W. Key Features. Image Show. 200W-600W HID Light Replacement

Compact Security FloodLight

SUBMERSIBLE WATER PUMP


Universal Retrofit System Installation Instructions Revised:

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

P/N Wheeler. user manual

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

OPERATION & MAINTENANCE INSTRUCTIONS

Installation and Operation Instructions 10/04/13

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Sieve Shaker 200mm/300mm - 8/12 inch SV003

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

QTFX-F1, QTFX-F2 FLAME EFFECT

75% ENERGY SAVINGS 200W-600W HID Light Replacement

Security Lighting INSTRUCTION MANUAL 16W, 28W, 36W & 50W PIR Security LED Floodlight

1 Safety instructions

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

LIGHT & SOUND BATH VANITY LIGHT

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

C3 Operating Instructions

Transcription:

INSTALLATI & MAINTENANCE MANUAL HBL series 230V 50Hz IP 65 122 1

GENERAL INSTRUCTIS These instructions should be read carefully and retained after installation by the end user for future reference and maintenance. These instructions should be used to aid installation of the following products: HBL100 / HBL150 / HBL200 / HBL240 SAFETY Installation of this luminaire should only be carried out by a qualified electrician or competent person to the latest Building and current IEE Wiring Regulations (BS7671) Please isolate mains prior to installation/maintenance Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse or circuit breaker Please note the IP (Ingress of Protection) rating of this luminaire when deciding the location for installation This product series is Class I and requires an earth This product series is IP65 rated (recommended indoor use only) This product is dimmable via a 1-10V dimmer INSTALLATI Provide power to the required point of installation. Suitable IP rated junctions boxes should be used where required Suspension mounting To suspend the fitting, screw the mounting hoop into the top of the luminaire (see Fig 1) Screw down mounting hoop Fig 1 2

Bracket mounting Using the bracket as a template, mark the location of the fixing holes, drill 2 x 10mm holes ensuring not to infringe with any joists, gas or water pipes or electrical cables Using a hammer, tap the expansion bolts into the 10mm fixing holes (see Fig 2) Fig 2 Tighten expansion bolt nuts but allow enough space for the bracket to mount Remove the driver housing via the 4 Allen screws (see Fig 3) Remove the 4 Allen screws Fig 3 Align the mounting bracket with 2 of the driver housing screw pillars (see Fig 4) Fig 4 3

Position the driver housing into the bracket ensuring all Allen screw holes are correctly aligned and fasten down the 4 Allen screws (see Fig 5) 5) Fasten down Allen screws Fig 5 Lift the fitting up to the expansion bolts and slide into the bracket (see Fig 6) Fig 6 Tighten the 2 expansion bolts to secure the luminaire to the surface To wire the luminaire without a dimmer (see fig 7) Earth green/yellow Live - brown Neutral - blue Fig 7 4

To wire the luminaire with a 1-10V dimmer (see Fig 8) Neutral - blue Earth green/yellow Live - brown Blue: Dim + White: Dim - Fig 8 To wire the luminaire with HBLS (see Fig 9) Earth green/yellow Live - brown Neutral - blue Neutral - blue Live - brown White: Dim - Black Switched live - yellow Blue: Dim + Red Attach the microwave sensor mounting bracket using the 5x screws provided Fig 9 5

INSTALLATI Detection area Detection area can be adjusted from a maximum range of 15 meters down to 7 meters by observing the below settings S1 Detection Area On 100% - 50% Hold time Hold time refers to the time that the luminaire will remain at 100% brightness after no motion is detected S2 S3 S4 HOLD TIME On On On 5sec - On On 30sec On - On 90sec - - On 3min On On - 20min - - - 30min Standby period Refers to the time period that the luminaire will remain at low light level in the absence of movement If set to DISABLE, the low light level will permanently be maintained until motion is detected S5 S6 S7 STANDBY PERIOD On On On DISABLE - On On 60min On - On 30min - - On 10min On On - 5min - - - 5sec 6

Standby dimming level This setting refers to the light level you require once hold time has elapsed S8 S9 STANDBY DIMMING LEVEL On On 50% - On 30% On - 20% - - 10% Daylight sensor This setting is to set the ambient light level you would require the luminaire to operate in, selecting DISABLE would enable the luminaire to operate at all times regardless of ambient light levels S10 S11 S12 DAYLIGHT SENSOR On On On DISABLE - On - 200lx On - - 100lx - - - 50lx Switch on and check for correct operation WARNING Do not use any source of high pressure washers to maintain or clean this luminaire Ensure correct fixtures are used for the surface that the luminaire is fixed to This luminaire is recommended for indoor use only 7

GENERAL The unit should be recycled in the correct manner when it reaches the end of its life. Check local authorities for where facilities exist Clean with a soft dry cloth only, do not use aggressive cleaning products or solvents which may damage the product Be aware that these products may require an MCB upgrade to a type C due to high inrush currents WARRANTY This product has a warranty of 5 years from date of purchase. Failure to install this product in accordance with the current edition of the IEE Wiring Regulations, improper use, or removal of the batch codes will invalidate the warranty. If this product should fail within its warranty period it should be returned to the place of purchase for a free of charge replacement. ML Accessories does not accept responsibility for any installation costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve the right to alter product specification without prior notice. ML Accessories Limited LU5 5TA www.mlaccessories.co.uk SBFEB17_V2 8