POWERED BY DOOSAN DIESEL GENERATOR SET

Similar documents
Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

Diesel Generating Set

Diesel Generating Set. Generator Ratings

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

Technical Data 280KW / 350KVA 256KW / 320KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz) General Features:

Technical Data 1600KW / 2000KVA 1450KW / 1813KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz)

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

FE - C KW / 650KVA 600KVA

Diesel Generating Set

CGT Stamford UCI 274 E1

Dual Frequency Diesel Genset

Prime Ratings (KW/KVA) 400/ / / /910

Diesel Generating Set

Weifang Ricardo Generator

kva kw r.p.m V V Cos Phi Ambient conditions of reference: 1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.

kva kw Rated Speed Standard Voltage r.p.m V V Cos Phi Rated at power factor

kva kw r.p.m V V Cos Phi Ambient conditions of reference: 1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.

SIVASA Doosan Series. SD250 Technical Data

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DW Series Generator. Specification BV-DW145

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

TPD2250H6.3 TECHNICAL DATA

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

PGDLS352KW 380/ / / / / / / / /

Model NA 2 L

Rating Definitions and Conditions

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

60 Hz FEATURES. Exclusively from your Caterpillar dealer

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Standby kw Prime kw

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Rating Definitions and Conditions

Model MP150 W W

Diesel generator set QSK23 series engine

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

Water-Cooled DEUTZ BF6M101. Standby: 200KW/250KVA. Prime: 180KW/225KVA

PGDLS / / / / / / / / /

Rating Definitions and Conditions

Rental Power QSB7 series engine

Rating Definitions and Conditions

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel generator set 6BT5.9 series engine

Diesel generator set QSK50 series engine

WPS150/S EP Series. Features:

Type Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]

PGKT / / / / / / / / / / / /

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET MTU 20V4000 DS3250

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

WPS20/S EP Series. Features:

Type Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]

Diesel generator set 4BT3.3 series engine

Diesel generator set QSX15 series engine

PGDLS / / / / / / / / /

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Diesel generator set QSL9-G7 series engine

WPS60/S EP Series. Features:

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SET. 60 Hz FEATURES

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

KH275. Frequency (Hz) Optional control panel POWER. Voltage

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Transcription:

MODEL Standby Power(50Hz) Prime Power(50Hz) ETDW550 440KW / 550KVA 400KW / 500KVA Standard Features General Features: Engine (DOOSAN P180LE) Radiator 40 O C max, fans are driven by belt, with safety guard 24V charge alternator Alternator: single bearing alternator IP23, insulation class H/H Absorber Dry type air filter, double fuel filter, oil filter, coolant filter Main line circuit breaker Standard control panel Two12V batteries, rack and cable Ripple flex exhaust pipe, exhaust siphon, flange, muffler User manual Generator Ratings Voltage HZ Phase P.F (COS ) Standby Amps Standby Ratings (KW/KVA) Prime Ratings (KW/KVA) 440/254 50 3 0.8 722 440/550 400/500 415/240 50 3 0.8 765 440/550 400/500 400/230 50 3 0.8 794 440/550 400/500 380/220 50 3 0.8 836 440/550 400/500 Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(eqvISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. Sales Promises Etone Power provides a full line of brand new and high quality products. Each and every unit is strictly factory tested. Warranty is according to our standard conditions: a, 15 months, counted on the day BAIFA sold to the first buyer; b, One year after installation; c, 1000 running hours (accumulated); subject to the earlier one. Service and parts are available from Baifa Power or distributors in your location. Specifications may change without notice 1/5

ENGINE DATA Manufacturer / Model: DOOSAN P180LE, 4-cycle Air Intake System: Turbo, Air/Air cooling Fuel System: BOSCH P type fuel pump Cylinder Arrangement: 10 in V Displacement: 18.273L Bore and Stroke: 128 142(mm) Compression Ratio: 15.0 Rated RPM: 1500rpm Max. Standby Power at Rated RPM: 496KW/674HP Governor Type: Electronic Exhaust System Exhaust Gas Flow: 97.9m 3 /min Exhaust Temperature: 606 Max Back Pressure: 6kPa Air Intake System Max Intake Restriction: 6.35kPa Consumption: 31.6m 3 /min Air Flow: 1065m 3 /min Fuel System 100%(Prime Power) Load: 111.6 L/h 75%(Prime Power) Load: 81.3 L/h 50%(Prime Power) Load: 54.8 L/h Oil System Total Oil Capacity: 35L Oil Consumption: 4g/kwh Engine Oil Tank Capacity: 28L Oil Pressure at Rated RPM: 345-483kPa Cooling System Total Coolant Capacity: 94L Thermostat: 79-94 Max Water Temperature: 103 Specifications may change without notice 2/5

ALTERNATOR SPECIFICATION GENERAL DATA Compliance with GB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standards. Alternator Data Number of Phase: 3 Connecting Type: 3 Phase and 4 Wires, Y type connecting Number of Bearing: 1 Power Factor: 0.8 Protection Grade: IP23 Altitude: 1000m Exciter Type: Brushless, self-exciting Insulation Class, Temperature Rise: H/H Telephone Influence Factor (TIF): <50 THF: <2% Voltage Regulation, Steady State: ±1% Alternator Capacity: 500KVA Alternator Efficiencies: 93.8% Air Cooling Flow: 1.035m 3 /s GENERATING SET DATA Voltage Regulation: Voltage Regulation, Stead State: Sudden Voltage Warp (100% Sudden Reduce): Sudden Voltage Warp (Sudden Increase): Voltage Stable Time (100% Sudden Reduce): Voltage Stable Time (Sudden Increase) Frequency Reduce: Frequency Waving: Sudden Frequency Warp (100% Sudden Reduce): Sudden Frequency Warp (Sudden Increase): Frequency Recovery Time (100% Sudden Reduce): Frequency Recovery Time (Sudden Increase): ±5% ±1% +25% -20% 6S 6S 5% Adjustable 0.5% +12% -10% 5S 5S Specifications may change without notice 3/5

Options Engine Fuel System Control System Heater 2KW & 4KW Daily Fuel Tank Remote Control Panel Battery Charger 3.5A & 7A Water Separator Auto Transfer Switch (ATS) Fuel Level Sensor Paralleling System Alternator Others Data Anti Condensation Heater Rainproof Type Engine Parts Drawing List Permanent Magnet Soundproof Type Spare Parts Generator(PMG) Drop CT(For Paralleling) Trailer Type Dimension & Weight Standard Configuration (Open Type) Overall Size: 3300(mm) 1390(mm) 1780(mm) Weight: 3285kg With Base Fuel Tank Overall Size: 3300(mm) 1390(mm) 1920(mm) Weight: 3500kg Soundproof Type Overall Size: 4630(mm) 1660(mm) 2250(mm) Weight: 5300kg Specifications may change without notice 4/5

Control Panel- SMARTGEN 6110/6120 Control Panel Technical Specifications The base mounted control panel in a vibration isolated sheet steel enclosure.the control panel is equipped as follows: a)instruments:analogue Volmeter,Hours Run Meter.Water pressure Meter. b) Controls:Emergency Stop Pushbutton,Volmeter Phase Selector Switch. c) Control module:standard collocation is smartgen Auto start with AMF. Main Features: ΔAutomatic mains failure ΔEngine control,generator protection ΔBuilt in alarms and warnings ΔRemote Start operation available ΔFuel pump control ΔMains simulation ΔBlock heater control ΔField adjustable parameters ΔFree MS-Windows Remote monitoring ΔLED displays ΔConfigurable analogue inputs ΔI/O expansion capability Protection Circuits WARNING Battery charge failure Low battery voltage SHUT DOWNS Fail to start Emergency stop Low oil pressure High engine temperature Over /Under speed Under/over generator frequency Failed to reach loading voltage Electrical trip Generator over current Instruments ENGINE Engine speed Oil pressure Coolant temperature Run time Battery volts TOR Voltage (L-N) Current (L1-L2-L3) Frequency Mains Voltage (L-L, L-N) Specifications may change without notice 5/5