Leica GKL341 User Manual. Version 1.0 EN

Similar documents
Leica GKL221 Charger User Manual

User Manual. Version 1.0 English. MC 200 Depthmaster

2800 OPERATING INSTRUCTIONS

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Operating Instructions

CAUTION-ELECTRICALLY OPERATED PRODUCT:

LITHIUM ION BATTERY CHARGER

OPERATING INSTRUCTIONS

82V LITHIUM-ION BATTERY CHARGER GC 400

SAFETY DATA SHEET Brila Recharge Lantern

SAFETY DATA SHEET Spright Recharge LED Lantern

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

Batteries and Chargers - White Paper Technical Specifications and Characteristics

HOVERTRAX 2.0 HOVERTRAX DLX 2.0 REPLACEMENT BATTERY PACK KIT


Please read and understand all precautions prior to use.

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

MULTI-FUNCTION JUMP STARTER

Bounce & Spin ZebraTM

Instruction Manual 03

User Manual Industrial Power Storage System (ips) ips-m Series Battery System

PRA 90. English. Printed: Doc-Nr: PUB / / 000 / 02

RC 4/36. English. Printed: Doc-Nr: PUB / / 000 / 02

Step1: Battery and Speaker Assembly Step 2: Pump and Battery Installation Step 3: Setting Up Your Fountain 6 Troubleshooting and Maintenance

Lots of Action in the Jungle!

OWNER S MANUAL Please read and understand all precautions prior to use.

L

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

Assembled Parts. Terminal Base. Barn Roof. Air Track with Tabs. 2 Barn Walls. Barn Base. 4 Air Tracks with Connectors. Air Track with Support

60V RECHARGEABLE LITHIUM-ION BATTERY

WIRELESS SMART CHARGING PAD OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT

M1800.

SHINE 3000 POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

Motion Activated Solar Powered LED Security Light MODEL: PSO1

L

V2700Z OWNER S GUIDE.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Safety Precaution. Notation. Meaning of symbols WARNING CAUTION

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

MODEL C HOVERBOARD USER MANUAL

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

6V MASERATI GRANTURISMO MC STRADALE OWNER S MANUAL KT1252TR. Age: 3-7 yrs Weight: Maximum 77 lbs (35 Kgs) Max Speed: 2.5 MPH Battery: 6V7AH

GATOR Battery-powered Pistol Grip Cable Cutters

Touchstone TB130 DC Output UPS

Sherman + Reilly Battery-powered Pistol Grip Cable Cutters

Go! Go! Smart Friends

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

LED Recessed Troffer Retrofit Kit

Owner's Manual. For latest instructions please go to

Owner s Manual and Assembly Instructions

LIGHT & SOUND BATH VANITY LIGHT

Owner s Manual with Assembly Instructions Please read this manual and save it. For Model RC09037

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

1000-Watt Energy Center

Bluetooth Smart Speed/Cadence Sensor Instruction Manual

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

Owner's Manual. For latest instructions please go to

900 PEAK AMP PORTABLE JUMP STARTER

HST-BL-2830MS & HST-BL-2830MS-USA

SRK12KX Battery-powered Crimping Tool

Owner's Manual. For latest instructions please go to

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

DSP led gaming monitor USER MANUAL

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

User Manual Pocket Pro, Pro + ph

RJH-4/6046. Wireless 3.5 Channel Mega Helicopter. (Instruction Manual)

Screwdriver. CAUTION: Read, understand and follow all Safety Rules and Operating Instructions in this manual before using this product.

Understanding the Transmitter NO.S107H -1- ON/OFF Button Left Rotation Trimming. Right rotation trimming

Switching DC Power Supply

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

INSTRUCTION MANUAL. 2-Speed Quad Ride-On SKY SKY SKY SKY4940. Ver. 2

User Guide. Digital Shipping Scale S150

Thermometer models / 00831A

Wireless Thermometer model 00380

Visit us at

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

Owner s Manual with Assembly Instructions Please read this manual and save it. For Model RC09075


Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

Memory Foam Massaging Bath Pillow with Wireless Remote Control

J5242.

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

DUAL WIRELESS CHARGING PAD, 10W X 2. Almohadilla de carga inalámbrica doble, 10W X2 USERS GUIDE

Press the buttons for fun sounds and music! fisher-price.com

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

User s Manual. Cruise & Learn CarTM VTech Printed in China US

X0056. fisher-price.com

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

SolarWrap. Quick Start Guide. Model # PP1040/PP1025

XM Series. Quick Start Guide. Technology at Work XMCom9

User s Manual. Forest Adventure Playset TM VTech Printed in China US CA

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

Mod: KLD6-12/35XLAS-N

integra trim ltd. Holiday Home: EASTER/SPRING Try Me Hang Tag - Children s Product I Play or I Sing Goes Here Name of Song TRY ME! Product Name 2 in.

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

Transcription:

Leica GKL341 User Manual Version 1.0

GKL341, Introduction 2 Introduction This manual contains important safety directions as well as instructions for setting up the product and operating it. Refer to Safety Directions for further information. Read carefully through the User Manual before you switch on the product. Product identification The type and serial number of your product are indicated on the type plate. Always refer to this information when you need to contact your agency or Leica Geosystems authorised service workshop. ZH KO JA RU PL ET FI SV NO DA NL PT IT ES FR DE

1 Description of the System Main Components GKL341 Not included in the delivery: DE FR GEV223 ES IT PT NL DA NO SV FI GDC221 ET PL RU JA (Country-specific cable; refer to "Power Supply") KO ZH 006324_001 GKL341, Description of the System 3

GKL341, Description of the System 4 Charger Components 006325_001 GDC221 GEV223 12/24 V 100-240 V ZH KO JA RU PL ET FI SV NO DA NL PT IT ES FR DE

Supported batteries Leica GEB211 GEB212 Leica GEB221 GEB222 Leica GEB241 GEB242 Leica GEB331 Ni-Cd Ni-MH DE FR ES IT PT Power supply 006326_001 Li-Ion, Li-Po NL DA NO 230 V 120 V SAE J563 (21 mm) ISO 4165 (12 mm) SV FI ET PL 006340_001 220 V 230 V 230 V 12/24 V GDC221 RU JA KO ZH GKL341, Description of the System 5

GKL341, Description of the System 6 Charging function / Calibration function Calibration 006327_001 Charging ZH KO JA RU PL ET FI SV NO DA NL PT IT ES FR DE

Charging times or...4h or...8h DE FR ES IT PT NL DA NO SV FI ET PL RU JA KO ZH 006328_001 GKL341, Description of the System 7

GKL341, Operation 8 2 Operation Connecting the charger 12/24 V 2 100-240 V 2 GDC221 1 1 ZH KO JA RU PL ET FI 100-240 0-240 V + 12/24 V 100-240 V 12/24 V SV NO DA NL PT IT ES GDC221 GDC221 FR DE 006329_001

2.1 Charging Function Inserting and charging the batteries 1 2 DE FR ES IT PT NL DA NO SV...30% 0%-30% FI ET...60% 31%-60% PL RU JA...90% 61%-90% KO ZH...100% 91%-100% 006330_001 GKL341, Operation 9

GKL341, Operation 10 Charging priority 1 2 3 4 1 2 ZH KO JA RU PL 3 4 ET FI SV NO DA NL PT 006331_001 100% 100% IT ES FR DE

Change of charging priority 1 2 3 4 4 3 1 2 DE FR ES IT PT NL DA 1 2 3 4 3 4 1 2 NO SV FI ET PL 4h 100% 4h 100% RU JA KO ZH 8h 100% 8h 100% 006332_001 GKL341, Operation 11

GKL341, Operation 12 2.2 Calibration Function Option 1: Charger recommends a Calibration 1 2 3 4 6 ZH KO JA RU PL Yes ET FI Carry out calibration? No 2 3 SV NO DA NL PT IT ES FR...10s DE 006333_002

4 5...5s Estimated calibration time <8h 8-12h 12-16h DE FR ES IT 16-24h PT NL 2s DA NO 6 0%-24% SV FI 25%-49% 50%-74% 75%-99% 100% Progress ET PL RU JA KO ZH 006342_002 GKL341, Operation 13

GKL341, Operation 14 Option 2: Request a calibration 1 2 006334_002 Calibration 3 4 6 ZH KO JA RU PL ET FI SV NO DA NL PT IT ES FR DE

4 5...5s Estimated calibration time <8h 8-12h 12-16h 16-24h 6 DE FR ES IT PT NL DA 2s NO SV 6 0%-24% 25%-49% 50%-74% 75%-99% 100% Progress FI ET PL RU JA KO ZH 006342_002 GKL341, Operation 15

GKL341, Operation 16 2.3 Firmware update Firmware Update 100-240 V 2 ZH 5 GEV223 4 1 KO JA RU PL 3 ET FI 100-240 V 6 12/24 V Firmware SV NO DA NL max. 1 min 100% PT IT Firmware ES FR 006335_001 > 1 min DE

3 Troubleshooting Error indication 0 C OR: 50 C 0 C 50 C DE FR ES IT PT NL DA NO SV FI ET PL RU JA KO ZH 006336_001 Low Input Voltage! GKL341, Troubleshooting 17

818785-1.0.1en/de/fr/es/it/pt/nl/da/no/sv/fi/et/pl/ru/ja/ko/zh Original text Printed in Switzerland 2014 Leica Geosystems AG, Heerbrugg, Switzerland Leica Geosystems AG Heinrich-Wild-Strasse CH-9435 Heerbrugg Switzerland Phone +41 71 727 31 31 www.leica-geosystems.com

Leica GKL341 User Manual Version 1.0 English

GKL341, Safety Directions 2 1 Safety Directions 1.1 General Introduction Description The following directions enable the person responsible for the product, and the person who actually uses the equipment, to anticipate and avoid operational hazards. The person responsible for the product must ensure that all users understand these directions and adhere to them. About Warning Messages Warning messages are an essential part of the safety concept of the product. They appear wherever hazards or hazardous situations can occur. Warning messages... make the user alert about direct and indirect hazards concerning the use of the product. contain general rules of behaviour. For the users safety, all safety instructions and safety messages shall be strictly observed and followed! Therefore, the manual must always be available to all persons performing any tasks described herein. DANGER, WARNING, CAUTION and NOTICE are standardized signal words for identifying levels of hazards and risks related to personal injury and property damage. For your safety it is important to read and fully understand the table below with the different signal words and their definitions! Supplementary safety information symbols may be placed within a warning message as well as supplementary text.

Type DANGER WARNING CAUTION NOTICE Description Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation or an unintended use which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor or moderate injury. Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in appreciable material, financial and environmental damage. Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner. Available documentation Name User Manual Description/Format All instructions required in order to operate the product to a basic level are contained in this User Manual. Provides an overview of the system together with technical data and safety directions. Refer to the following resources for all GKL341 documentation: http://www.leica-geosystems.com/downloads GKL341, Safety Directions 3

GKL341, Safety Directions 4 1.2 Definition of Use Intended use Charging and discharging of Li-Ion and Li-Po batteries. First-time use / Charging batteries Reasonably foreseeable misuse The battery must be charged prior to using it for the first time. The permissible temperature range for charging is between 0 C to +40 C/ +32 F to +104 F. For optimal charging, we recommend charging the batteries at a low ambient temperature of +10 C to +20 C/+50 F to +68 F if possible. It is normal for the battery to become warm during charging. Using the chargers recommended by Leica Geosystems, it is not possible to charge the battery if the temperature is too high. For Li-Ion batteries, a single refreshing cycle is sufficient. We recommend carrying out a refreshing cycle when the battery capacity indicated on the charger or on a Leica Geosystems product deviates significantly from the actual battery capacity available. Use of the product without instruction. Use outside of the intended use and limits. Disabling safety systems. Removal of hazard notices. Opening the product using tools, for example screwdriver, unless this is permitted for certain functions. Modification or conversion of the product. Use after misappropriation. Use of products with recognisable damages or defects.

1.3 Limits of Use Environment Suitable for use in dry environments only and not under adverse conditions. Environmental Specifications For further information about operating/storing temperatures and protection against water, dust and sand refer to "3 Technical Data" 1.4 Responsibilities Manufacturer of the product Person responsible for the product Leica Geosystems AG, CH-9435 Heerbrugg, hereinafter referred to as Leica Geosystems, is responsible for supplying the product, including the user manual and original accessories, in a safe condition. The person responsible for the product has the following duties: To understand the safety instructions on the product and the instructions in the user manual. To ensure that it is used in accordance with the instructions. To be familiar with local regulations relating to safety and accident prevention. To inform Leica Geosystems immediately if the product and the application becomes unsafe. To ensure that the national laws, regulations and conditions for the operation of e.g. radio transmitters or lasers are respected. GKL341, Safety Directions 5

GKL341, Safety Directions 6 1.5 Hazards of Use WARNING The product is not designed for use under wet and severe conditions. If unit becomes wet it may cause you to receive an electric shock. Precautions: Use the product only in dry environments, for example in buildings or vehicles. Protect the product against humidity. If the product becomes humid, it must not be used! WARNING WARNING If you open the product, either of the following actions may cause you to receive an electric shock. Touching live components Using the product after incorrect attempts were made to carry out repairs Precautions: Do not open the product. Only Leica Geosystems authorised service workshops are entitled to repair these products. Using the charger inside a driving vehicle can lead to dangerous situations which may result in damage or personal injury. Precautions: If it can be avoided, do not use the charger inside a driving vehicle. If it is necessary to use the charger inside a driving vehicle: Ensure that the charger is properly secured against sudden movements, such as acceleration, braking, or steering movements.

WARNING WARNING WARNING WARNING If the ventilation slots are covered while the product is being used, the product can overheat and cause injury or fire. Precautions: Make sure that the ventilation slots are not covered by any objects while the product is being used. If charged or discharged, batteries not recommended by Leica Geosystems may be damaged. They may burn and explode. Precautions: Only charge and discharge batteries recommended by Leica Geosystems. During the transport, shipping or disposal of batteries it is possible for inappropriate mechanical influences to constitute a fire hazard. Precautions: Before shipping the product or disposing it, discharge the battery by the product until they are flat. When transporting or shipping batteries, the person in charge of the product must ensure that the applicable national and international rules and regulations are observed. Before transportation or shipping contact your local passenger or freight transport company. High mechanical stress, high ambient temperatures or immersion into fluids can cause leakage, fire or explosions of the batteries. Precautions: Protect the batteries from mechanical influences and high ambient temperatures. Do not drop or immerse batteries into fluids. GKL341, Safety Directions 7

GKL341, Safety Directions 8 WARNING WARNING If battery terminals are short circuited e.g. by coming in contact with jewellery, keys, metalized paper or other metals, the battery can overheat and cause injury or fire, for example by storing or transporting in pockets. Precautions: Make sure that the battery terminals do not come into contact with metallic objects. If the product is improperly disposed of, the following can happen: If polymer parts are burnt, poisonous gases are produced which may impair health. If batteries are damaged or are heated strongly, they can explode and cause poisoning, burning, corrosion or environmental contamination. By disposing of the product irresponsibly you may enable unauthorised persons to use it in contravention of the regulations, exposing themselves and third parties to the risk of severe injury and rendering the environment liable to contamination. Precautions: The product must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regulations in force in your country. Always prevent access to the product by unauthorised personnel. Product-specific treatment and waste management information can be downloaded from the Leica Geosystems home page at http://www.leica-geosystems.com/treatment or received from your Leica Geosystems dealer.

1.6 Electromagnetic Compatibility EMC Description WARNING CAUTION CAUTION The term Electromagnetic Compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present, and without causing electromagnetic disturbances to other equipment. Electromagnetic radiation can cause disturbances in other equipment. Although the product meets the strict regulations and standards which are in force in this respect, Leica Geosystems cannot completely exclude the possibility that other equipment may be disturbed. There is a risk that disturbances may be caused in other equipment if the product is used with accessories from other manufacturers, for example field computers, personal computers or other electronic equipment, non-standard cables or external batteries. Precautions: Use only the equipment and accessories recommended by Leica Geosystems. When combined with the product, they meet the strict requirements stipulated by the guidelines and standards. When using computers or other electronic equipment, pay attention to the information about electromagnetic compatibility provided by the manufacturer. Disturbances caused by electromagnetic radiation can result in erroneous measurements. Although the product meets the strict regulations and standards which are in force in this respect, Leica Geosystems cannot completely exclude the possibility that the product may be disturbed by intense electromagnetic radiation, for example, near radio transmitters, two-way radios or diesel generators. Precautions: Check the plausibility of results obtained under these conditions. GKL341, Safety Directions 9

GKL341, Safety Directions 10 CAUTION If the product is operated with connecting cables attached at only one of their two ends, for example external supply cables, interface cables, the permitted level of electromagnetic radiation may be exceeded and the correct functioning of other products may be impaired. Precautions: While the product is in use, connecting cables, for example product to external battery, product to computer, must be connected at both ends. 1.7 FCC Statement, Applicable in U.S. WARNING This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help.

WARNING Changes or modifications not expressly approved by Leica Geosystems for compliance could void the user's authority to operate the equipment. Type Plate Labelling GKL341 006323_001 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 100529000001 100529000001 2 Care and Transport 2.1 Transport Shipping Transport in a road vehicle When transporting the product by rail, air or sea, always use the complete original Leica Geosystems packaging, transport container and cardboard box, or its equivalent, to protect against shock and vibration. Never carry the product loose in a road vehicle, as it can be affected by shock and vibration. Always carry the product in its transport container, original packaging or equivalent and secure it. GKL341, Care and Transport 11

GKL341, Care and Transport 12 Shipping, transport of batteries When transporting or shipping batteries, the person in charge of the product must ensure that the applicable national and international rules and regulations are observed. Before transportation or shipping, contact your local passenger or freight transport company. 2.2 Storage Product Storing Respect the temperature limits when storing the equipment, particularly in summer if the equipment is inside a vehicle. Refer to "Technical Data" for information about temperature limits. Long-term battery storage is not recommended. If storage is necessary: Refer to "Temperature range" for information about storage temperature range. Remove batteries from the product and the charger before storing. After storage recharge batteries before using. Protect batteries from damp and wetness. Wet or damp batteries must be dried before storing or use. A storage temperature range of 0 C to +30 C/+32 F to 86 F in a dry environment is recommended to minimise self-discharging of the battery. At the recommended storage temperature range, batteries containing a 40% to 50% charge can be stored for up to one year. After this storage period the batteries must be recharged. Always try to use a first-in first-out approach to minimise storage time. 2.3 Cleaning and Drying Cables and plugs Use only a clean, soft, lint-free cloth for cleaning. Keep plugs clean and dry. Blow away any dirt lodged in the plugs of the connecting cables.

3 Technical Data Power Supply Mains connection, ~ DC voltage connection, Input Voltage 100-240 V ~/50-60 Hz 24 V DC Charging power Discharging power Power rating Operating environment Maximum 56 Watt (0 C to +40 C) / Maximum 28-56 Watt (+40 C to +50 C) Maximum 7.5 Watt Maximum 65 Watt Only operate in dry environments, for example in buildings and vehicles. Temperature range Storing the charger: -40 C to +70 C/-40 F to +158 F Operating the charger: 0 C to +50 C/+32 F to +122 F Protection against solid objects Cell type Type Protection GKL341 IP30 (IEC 60529) Protected against solid objects > 2.5 mm Li-Ion and Li-Po Charging times 1-2 batteries: up to 4.0 h 3-4 batteries: up to 8.0 h GKL341, Technical Data 13

GKL341, Conformity Declarations 14 Calibration times Weight Maximum 24 h Calibration time depends primarily on the charging and discharging current, the nominal capacity of the battery and its state of charge. Calibration time is also affected by other batteries which are already inserted. Charger: ca. 950 g Dimensions Width: Depth: Height: 300 mm 208.5 mm 49.4 mm 4 Conformity Declarations Conformity to national regulations FCC Part 15 (applicable in US) Hereby, Leica Geosystems AG, declares that the GKL341 is in compliance with the essential requirements and other relevant provisions of the applicable European Directives. The declaration of conformity may be consulted at http://www.leica-geosystems.com/ce.

818785-1.0.1en Original text Printed in Switzerland 2014 Leica Geosystems AG, Heerbrugg, Switzerland Leica Geosystems AG Heinrich-Wild-Strasse CH-9435 Heerbrugg Switzerland Phone +41 71 727 31 31 www.leica-geosystems.com