SIGRAM FLUE SYSTEMS LTD

Similar documents
InoxSabiana 50 Flues Stainless Steel Double Wall ENVIRONMENTAL COMFORT

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

Model DW Series Positive Pressure Guidelines for Engine Exhaust Systems

Stove & Fireplace Chimney Systems & Enamelled Flue Pipe

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Nederlands English DW25

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

FLUE PIPE ACCESSORIES FOR STANDARD AND CONDENSING GAS BOILERS

Model VSI-I & VSI-II Positive Pressure Venting Systems

Stainless Steel Chimneys Ducts and Fittings for Air Conditioning & Ventilation

Nederlands English TP INOX 304

MD & IS RANGE CHIMNEY SYSTEMS. Gas & Smoke exhaust. Innovating Solutions

Nederlands English TP INOX 304

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Nederlands English TP INOX 304

Nederlands English SDW50

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Gas Venting Systems residential industrial commercial

Technical and Dimensional Data. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

Nederlands English ADW10

Flue installation instructions. Air flue duct for use with ecomax and ecotec boilers. For the installer

CONTENTS. Ordering Information... Page 3. Cardrona, Monaco, Geneva, Vienna... Page 4 Offset & Extension Kits For Freestanding Fires...

Our mission is to become the supplier of choice for gas venting products and solutions.

Engineering Standard. Fig 707 Safety Relief Valve Installation and Maintenance Instructions

New products. The plastic silencer AGP The new standard

Models PS/IPS. Stainless Steel Double Wall Positive Pressure Piping Systems FEATURES CATALOG

besseges Handrail Catalogue VALVES TUBES FITTINGS

venting systems for high efficiency appliances series

Zhejiang Ejai Kitchen & Bath Technology Co., ltd

Tecduct Plastic Ducting

INSTALLATION AND MAINTENANCE INSTRUCTIONS

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

INSTALLATION AND MAINTENANCE INSTRUCTIONS

Technical and Dimensional Data. Double Wall One Inch Air Space AL 29-4C Stainless Steel Special Gas Vent

Vertical Balanced Flue Kit All Internal Grant Boilers

Technical and Dimensional Data. Double Wall One Inch Air Space 316L Stainless Steel Special Gas Vent

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Ventinox kits. Ventinox VFT Kit without Tee. Ventinox VFT Kit with Tee. Ventinox VFT Extensions. Flexible Relining Ventinox

Direct or Non-Direct Venting

MD & IS RANGE CHIMNEY SYSTEMS. Gas & Smoke exhaust. Innovating Solutions

INSTALLATION INSTRUCTIONS FOR SOLID VENT KIT PART NUMBER

Ø

Model N. Stainless Steel Double Wall Positive Pressure Venting Systems. Special Gas Vent Applications COMMERCIAL AND INDUSTRIAL VENTING

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

,!';' ~ i ~ i~, ~ ~ i. c ; 1 ; ~

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

WHISPERPOWER GENERATOR SETS

Model RIS ALL FUEL, INSULATED CHIMNEY SYSTEM 10" - 24"

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1

FIREPLACE COMPONENTS

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1

HIGH CAPACITY POWER VENT KIT

Nederlands English CONDENS'INOX

Nederlands English COAX PELLET

ECONOMATIC REX/REXF REX/REXF DUAL STR

Single wall flue system

quality industry solutions

HOSE, TUBE & CONNECTION FITTINGS CATALOGUE. JSG Industrial Systems quality industry solutions. Fire Suppression Systems. Flow Measurement Systems

REX/REX F/REX K/REX K F REX DUAL/REX DUAL F

11. Installation Instruction

SOLAR AEROLINE. fast simple reliable. The perfect connection technology for solar hot water

RECEIVING AND INSPECTION EXAMINE ALL COMPONENTS FOR POSSIBLE SHIPPING DAMAGE PRIOR TO INSTALLATION.

1mm GALVANIZED PIPE SYSTEM

HDPE Pipe. Catalogue

RECEIVING AND INSPECTION

Versatility in Applications

PRESSURIZED STEEL BOILER WITH REVERSED FLAME

Opening hours Monday - Friday, 8.00am pm Weekends and Bank Holidays, 8.30am pm We are closed on Christmas Day and New Year s Day.

Already from ** about: 60,- /m². Collector-width about 2,0 m. solar area about m². rows of retaining frames. Collector-width about 3,5 m

SINGLE WALL AL 29-4C SPECIAL GAS VENT

ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD. ELECTRIC SHOCK HAZARD/FIRE AND/OR EXPLOSION HAZARD.

VENTING & COMBUSTION AIR GUIDE

BENSON AMBIRAD. ... Cabinet Heaters Gas & Oil Fired Heaters ... HEATI NG AND VENTILATION S OLUTIONS

82 series Brass compression fittings

VICTRIX PRO Wall-hung modular condensing boiler for heating only

Stradaflair. Strada Trench Convectors. Strada Flat Panel Range. Strada Radiant Skirting. Strada Heated & Chilled Ceilings. Strada Electrical Products

Operation and Maintenance Instructions

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

NEW All Biomass Chimney components are available in matte black. Just add "B" to the end of the part numbers you are ordering.

C SmartCom3 Heat Exchanger models abinet Heaters

Gasfire Flue Kits. B Vent Gas Flue Kit - Metallic Black (galvanised)

RECTANGULAR, 2-HOUR FIRE RATED, ZERO-CLEARANCE GREASE DUCT CO.

83 series Brass compression fittings

XIII. Repair Parts 106

Item No. Item Description In Stock

APT14 Automatic Pump Trap Installation and Maintenance Instructions

NEW FasNSeal 80/90. FasNSeal & FasNSeal W2. FasNSeal Flex. Exhausts 90+ condensing appliances with Type B atmospheric units within the same vent.

Item No. Item Description In Stock

PRE-INSTALLATION VENTING AND COMBUSTION AIR DESIGN GUIDE

VT Oil-Free Range Operators Handbook

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

DIGIFLO ELECTRONIC FLOWMETER

SOLAR WORLD, INC. INSTALLATION MANUAL

Replacement Parts. Suitable for David Brown Applications

Installation Instructions

Twin City Fan & Blower

Great discounts Next day delivery Wide product range Extensive stock. Chimneys Liners Renewables. Call us today on

Installation Instructions

Transcription:

SIGRAM FLUE SYSTEMS LTD TEL: 0161 320 1999 FAX: 0161 320 6515 E-MAIL: sales@sigram.co.uk WEB: www.sigram.co.uk FLUE SYSTEMS FOR INDUSTRIAL & COMMERCIAL APPLICATIONS SINCE 1969 PROJECT WORK SITE SURVEY MANUFACTURE INSTALLATION SYSTEM DE SINGLE SKIN

Application Technical Data SYSTEM DE Chimney/Flue System/Connecting Flue Installation Method Operating Mode Dry/Wet Pressure Negative/positive pressure Max. Working pressure 200 Pa Operating temperature 450 C negative pressure (EN 1856-2) 400 C negative pressure (EN 1856-1) 200 C positive pressure Max. temperature allowed 1000 C negative pressure (EN 1856-2) (max. 30min.) 400 C negative pressure (EN 1856-1) 200 C positive pressure Material AISI 316L/EN 1.4404 Thickness minimal 0.5mm Sealant Elastomer Fuel Type Natural gas/calor gas/propane gas INSTALLATION NOTES SPECIFICALLY FOR CONDENSING APPLICATIONS. On all condensing applications, system must be fitted with a minimum 3 degree slope back towards the appliance/s. (appliance and/or system drain point required at lowest point/s.) Note: A system slope of 3 degrees equates to 5.2CM per linear metre. Systems must be adequately supported, with horizontal run supports not exceeding two metre centres. Applications SYSTEM DE Shaft liner in renovation projects Air inlet & ventilation systems Flue system for condensing heaters and boilers Chimney renovation Applications SYSTEM DE Stress free thermal expansion Can be connected to System DF High quality stainless steel system High temperature silicone sealing ring Universal application Fully welded system with sealing ring Light weight system Check all parts for possible damage. During installation you may have to use our special installing grease. The installation of the chimney starts at the appliance and then progresses upwards to the terminal. The top of each element can be recognised by the profile edge (fig.1). At the bottom of each section (DE 100) an arrow is printed which indicates the direction of flow. Connect two elements by pushing them vertically into each other. For visual reasons it is advisable to place the welding seams at the rear if possible. The sealing ring in the inner wall must remain in its position and must not be damaged during connection of the elements. When the elements are connected then fix the locking band (fig. 2) Then install the next element as instructed above. DIAMETER CROSS SECTIONAL AREA WEIGHT KG/M Diameter mm 80 100 130 150 180 200 250 300 350 400 Cross Section cm² 50 79 133 177 254 314 491 707 962 1256 Weight kg/m 1.5 1.5 2 2.5 3 3 4 4.5 5.5 6 PAGE 2

DE BOILER CONNECTION LENGTH DE 1000MM LENGTH H1 100 100 100 100 100 100 100 100 100 100 H1 950 950 950 950 950 950 950 950 945 945 DE 500MM LENGTH DE 250MM LENGTH 250MM LENGTH H1 445 445 445 445 445 445 445 445 445 445 H1 195 195 195 195 195 195 195 195 195 195 DE 150MM LENGTH DE ADJUSTABLE LENGTH H1 100 100 100 100 100 100 100 100 100 100 Hmin 200 200 200 200 200 200 200 200 200 200 Hmax 300 300 300 300 300 300 300 300 300 300 PAGE 3

DE 15 DEGREE ELBOW SYSTEM DE DE 30 DEGREE ELBOW K 35 40 45 50 55 60 70 70 70 85 M 80 85 95 100 105 115 115 115 130 X 20 20 20 25 25 25 30 30 30 35 Y 105 115 125 135 145 155 175 175 175 205 DE 45 DEGREE ELBOW K 35 40 45 50 55 60 70 70 70 85 M 80 85 95 100 105 115 115 115 130 X 40 40 45 45 50 50 55 55 55 65 Y 100 110 120 130 135 145 165 165 165 195 DE 87 DEGREE ELBOW K 35 40 45 50 55 60 70 95 95 105 M 80 85 95 100 105 115 140 140 150 X 55 60 60 65 70 70 80 95 95 105 Y 95 105 115 125 130 150 1 1 205 DE 45 DEGREE TEE K 35 40 45 50 55 60 70 95 95 105 L 100 105 115 125 145 165 185 210 210 230 M 80 85 95 100 105 115 140 140 150 X 150 160 170 185 200 220 245 2 2 310 Y 105 115 125 140 160 175 200 245 245 270 DE 87 DEGREE TEE H 340 380 450 450 470 470 470 6 6 6 h1 195 235 310 310 310 310 310 500 500 500 X 115 135 155 165 175 185 205 340 360 425 H 200 200 250 250 300 300 350 450 500 550 h1 75 75 100 100 125 125 150 200 225 250 X 65 75 100 115 125 150 175 200 225 PAGE 4

DE DEGREE TEE DE 87 DEGREE REDUCING TEE H 200 200 250 250 300 300 350 450 500 550 h1 75 75 100 100 125 125 150 200 225 250 Ø 100 130 150 180 200 250 X 75 100 115 125 150 X 65 75 100 115 125 150 175 200 225 DE CONDENSATE COLLECTOR C/W DRAINPOINT DE END CAP WITHOUT DRAIN 3/4 BSP CONNECTION DE PROBE LENGTH AND DRAIN HORIZONTAL DE PROBE LENGTH AND DRAIN VERTICAL Ø 100 130 150 180 200 3/4 BSP CONNECTION 3/4 BSP CONNECTION PAGE 5

DE MESH END TOP DE VENTURI END TOP Ø 100 130 150 180 200 250 300 350 400 D 95 123 142 171 1 237 285 332 380 DE ALL WEATHER COWL CAP DE RAIN CAP A 175 220 285 330 395 440 550 660 770 880 B 110 145 165 200 220 275 330 385 440 D 78 98 127 147 177 197 247 297 347 397 H 120 150 195 210 270 300 375 450 525 600 DE STORM COLLAR Ø 130 150 180 200 A 285 330 395 440 D 127 147 177 197 H 330 370 440 475 h1 195 225 270 300 FLAT TRIM PLATE A 205 225 255 275 305 325 375 425 475 525 A 280 300 330 350 380 400 450 500 550 600 B 280 300 330 350 380 400 450 500 550 600 PAGE 6

DE INCREASER DE EXCENTRIC INCREASER Ø 80 80 130 130 130 150 180 180 200 200 250 300 350 D 60 70 80 100 113 130 150 130 180 150 200 250 300 H 165 165 155 145 195 195 195 140 195 155 230 230 230 DE REDUCER Ø 100 130 150 180 200 250 300 350 400 D To be specified on order 130 150 180 200 250 300 350 DE ADAPTOR DOUBLE FEMALE Ø 80 130 100 150 180 200 250 300 D 100 150 130 180 200 250 300 350 H 165 195 165 195 195 230 230 230 DE DRAUGHT STABILIZER DE LOCKING BAND Ø 130 150 180 PAGE 7

DE FLAT ROOF FLASHING SYSTEM DE DE SLOPE ROOF FLASHING D 100 125 150 180 200 230 280 325 375 425 A SQ 450 450 450 500 500 600 600 700 700 750 DE LEAD FLASHING 20-45 DEGREE Ø 80 100 130 150 180 200 250 300 350 A N/A N/A N/A 155 185 205 305 305 355 C N/A N/A N/A 520 550 575 685 685 740 C N/A N/A N/A 500 530 550 655 655 705 H N/A N/A N/A 155 160 160 175 175 185 DE MOUNTING BAND (LIGHT WEIGHT) 400 405 795 760 200 A N/A N/A N/A 160 1 210 260 310 360 410 C N/A N/A N/A 750 750 750 750 750 750 750 C N/A N/A N/A 750 1000 1000 1000 1000 1000 1000 DE SPLIT RINGS Ø 80 100 130 150 180 200 250 DE WALL BAND ADJUSTABLE X 116 116 160 160 160 160 160 160 360 360 b 35 35 55 55 55 55 55 55 60 60 H 25-50 25-50 105 PAGE 8

DE SWING RING BAND DE WALL SUPPORT BAND (ADJUSTABLE) CEMBV 2 A -200 CEMBV 3 A 1-300 CEMBV 4 A 2-400 Ø 150 180 200 250 300 350 400 X 180 210 230 280 330 380 430 DE SUPPORT ARMS C/W FLUE RING DE SUPPORT ARMS C/W FLUE RING A 45 55 70 80 95 105 130 155 N/A N/A B 165 165 165 165 165 165 165 165 N/A N/A D 180 180 180 180 180 180 180 180 N/A N/A A 160 160 160 160 160 165 165 165 180 205 B 265 265 265 265 265 265 265 265 265 265 D 280 280 280 280 280 280 280 280 280 280 DE SUPPORT ARMS C/W FLUE RING DE GUY WIRE BAND A 260 260 260 260 260 260 260 260 260 260 B 365 365 365 365 365 365 365 365 365 365 D 380 380 380 380 380 380 380 380 380 380 PAGE 9

TWIN-WALL PRODUCT RANGE ALSO AVAILABLE REFER TO SYSTEM DF CATALOGUE Whilst every effort has been made to provide reliable information and dimension accuracy, Sigram Flue Systems limited do not hold themselves responsible for possible errors of an editorial nature, however caused. Sigram are committed to the concept of continuous quality and improvement, therefore we reserve the right to alter product specification without notice. SIGRAM FLUE SYSTEMS LTD UNIT 8 SHEPLEY INDUSTRIAL ESTATE SOUTH SHEPLEY RD AUDENSHAW MANCHESTER M34 5DW TEL: 0161 320 1999 FAX: 0161 320 6515 E-MAIL: sales@sigram.co.uk WEB: www.sigram.co.uk