Cat C Diesel Generator Sets

Similar documents
Cat C Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3512 Diesel Generator Sets

Cat 3412 Diesel Generator Sets

Cat C32 Diesel Generator Sets

Cat 3512 Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3516B Diesel Generator Sets

Cat 3512B Diesel Generator Sets

Cat 3512B Diesel Generator Sets

Cat C32 Diesel Generator Sets

Cat 3516C Diesel Generator Sets

Cat 3512B Diesel Generator Sets

Cat C32 Diesel Generator Sets

Cat 3512B Diesel Generator Sets

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

Continuous, Prime, Standby, Mission Critical

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

3412C Generator Set Electric Power. Specifications. Benefits and Features

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Voltage 220 to or 1800 RPM

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

Specifications. 3406C Generator Set Electric Power

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

220 to volts. Electronic unit injection

400 to 11,000 Volts. Standby, Prime, Continuous

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Generator Set Specifications 100 ekw (125 kva)

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Aftercooler (Separate Circuit) N/A N/A

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

STANDBY 400 ekw 500 kva

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

PRIME 225 ekw 281 kva

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES

Specifications. C13 Generator Set Electric Power

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

Generator Set Specifications Rating (ekw) Rating (kva) Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Generator Set Specifications 60 ekw (75 kva)

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

DIESEL FEATURES GENERATOR SET

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

C32 ACERT Generator Set Electric Power

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

Generator Set Specifications 320 ekw (400 kva)

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

Transcription:

Cat C175-20 Diesel Generator Sets Image shown may not refl ect actual confi guration Bore 175 (6.89) Stroke 220 (8.66) Displacement L (in 3 ) 105.8 (6456.31) Compression Ratio 15.3:1 Aspiration TA Fuel System Common Rail Governor Type ADEM A4 Standby Mission Critical Prime Continuous Emissions Performance 3900 (3120) 3900 (3120) 3500 (2800) 3150 (2520) Low Fuel Consumption 3900 (3120) 3900 (3120) Optimized for Low Emissions Standard Features Cat Diesel Engine Designed and optimized for low emissions or low fuel consumption Reliable performance proven in thousands of applications worldwide Generator Set Package Accepts 100% block load in one step and meets other NFPA 110 loading requirements Conforms to ISO 8528-5 G3 load acceptance requirements Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing Alternators Superior motor starting capability minimizes need for oversizing generator Designed to match performance and output characteristics of Cat diesel engines Cooling systems available to operate in ambient temperatures up to 50 C (122 F) Tested to ensure proper generator set cooling EMCP 4 Control Panels User-friendly interface and navigation Scalable system to meet a wide range of installation requirements Expansion modules and site specific programming for specific customer requirements Warranty 24 months/1000-hour warranty for standby and mission critical ratings 12 months/unlimited hour warranty for prime and continuous ratings Extended service protection is available to provide extended coverage options Worldwide Product Support Cat dealers have over 1,800 dealer branch stores operating in 200 countries Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements Financing Caterpillar offers an array of financial products to help you succeed through financial service excellence Options include loans, finance lease, operating lease, working capital, and revolving line of credit Contact your local Cat dealer for availability in your region LEHE1219-01

Optional Equipment Engine Air Cleaner Single element Muffler Industrial grade (15 db) Residential grade (25 db) Critical grade (35 db) Starting Standard batteries Oversized batteries Standard electric starter(s) Heavy duty electric starter(s) Dual electric starter(s) Air starter(s) Jacket water heater Alternator Output voltage 3300V 10000V 6300V 10500V 6600V 11000V 6900V Temperature Rise (over 40 C ambient) 150 C 125 C/130 C 105 C 80 C Winding type Form wound Excitation Permanent magnet (PM) Attachments Anti-condensation heater Stator and bearing temperature monitoring and protection Control System Controller EMCP 4.2 EMCP 4.3 Attachments Local annunciator module Remote annunciator module Expansion I/O module Remote monitoring software Charging Battery charger 20A Battery charger 35A Battery charger 50A Vibration Isolators Rubber Spring Seismic rated Extended Service Options Terms 2 year (prime) 3 year 5 year 10 year Coverage Silver Gold Platinum Platinum Plus Ancillary Equipment Automatic transfer switch (ATS) Uninterruptible power supply (UPS) Paralleling switchgear Paralleling controls Certifications IBC seismic certification EU Certification of Conformance (CE) EEC Declaration of Conformity Note: Some options may not be available on all models. Certifi cations may not be available with all model confi gurations. Consult factory for availability. LEHE1219-01 Page 2 of 5

Package Performance Low Fuel Consumption Performance Standby Mission Critical Prime Continuous Frequency 50 Hz 50 Hz 50 Hz 50 Hz Gen set power rating with fan 3120 ekw 3120 ekw 2800 ekw 2520 ekw Gen set power rating with fan @ 0.8 power factor 3900 kva 3900 kva 3500 kva 3150 kva Emissions Low Fuel Low Fuel Low Fuel Low Fuel Performance number EM0805-01 EM0804-00 EM0806-03 EM0807-00 Fuel Consumption 100% load with fan L/hr (gal/hr) 787.4 (208.0) 787.4 (208.0) 709.7 (187.5) 639.8 (169.0) 75% load with fan L/hr (gal/hr) 596.9 (157.7) 596.9 (157.7) 539.0 (142.4 ) 490.9 (129.7) 50% load with fan L/hr (gal/hr) 421.9 (111.5) 421.9 (111.5) 382.6 (101.1) 351.3 (92.8) 25% load with fan L/hr (gal/hr) 243.7 (64.4) 243.7 (64.4) 226.8 (59.9) 214.2 (56.6) Radiator air flow restriction (system) kpa (in. water) 0.12 (0.48) 0.12 (0.48) 0.12 (0.48) 0.12 (0.48) Radiator air flow m 3 /min (cfm) 3334 (117739) 3334 (117739) 3334 (117739) 3334 (117739) Engine coolant capacity L (gal) 440 (116.2) 440 (116.2) 440 (116.2) 440 (116.2) Radiator coolant capacity L (gal) 845 (223.2) 845 (223.2) 845 (223.2) 845 (223.2) Total coolant capacity L (gal) 1285 (339.5) 1285 (339.5) 1285 (339.5) 1285 (339.5) Inlet Air Combustion air inlet flow rate m 3 /min (cfm) 267.0 (9428.2) 267.0 (9428.2) 254.0 (8970.4) 232.5 (8210.7) Exhaust System Exhaust stack gas temperature C ( F) 421.7 (791.1) 421.7 (791.1) 416.4 (781.6) 410.7 (771.3) Exhaust gas flow rate m 3 /min (cfm) 652.1 (23025.5) 652.1 (23025.5) 596.5 (21063.9) 541.3 (19113.8) Exhaust system backpressure (maximum allowable) kpa (in. water) 6.7 (27.0) 6.7 (27.0) 6.7 (27.0) 6.7 (27.0) Heat Rejection Heat rejection to jacket water kw (Btu/min) 1613 (91740) 1613 (91740) 1399 (79558) 1250 (71076) Heat rejection to exhaust (total) kw (Btu/min) 2762 (157061) 2762 (157061) 2530 (143895) 2293 (130397) Heat rejection to aftercooler kw (Btu/min) 372 (21174) 372 (21174) 309 (17588) 258 (14685) Heat rejection to atmosphere from engine kw (Btu/min) 183 (10426) 183 (10426) 176 (10030) 172 (9795) Heat rejection from alternator kw (Btu/min) 133 (7593) 133 (7593) 120 (6813) 108 (6130) Emissions (Nominal) NOx mg/nm 3 (g/hp-h) 4168.7 (7.87) 4168.7 (7.87) 4215.3 (7.90) 4296.5 (7.97) CO mg/nm 3 (g/hp-h) 61.8 (0.13) 61.8 (0.13) 59.2 (0.12) 66.7 (0.14) HC mg/nm 3 (g/hp-h) 21.0 (0.05) 21.0 (0.05) 23.4 (0.06) 26.6 (0.06) PM mg/nm 3 (g/hp-h) 6.2 (0.05) 6.2 (0.05) 8.6 (0.02) 14.6 (0.03) Emissions (Potential Site Variation) NOx mg/nm 3 (g/hp-h) 5002.5 (9.45) 5002.5 (9.45) 5058.4 (9.48) 5155.8 (9.56) CO mg/nm 3 (g/hp-h) 112.2 (0.23) 112.2 (0.23) 106.5 (0.22) 120.1 (0.24) HC mg/nm 3 (g/hp-h) 27.9 (0.07) 27.9 (0.07) 31.1 (0.07) 35.4 (0.08) PM mg/nm 3 (g/hp-h) 8.7 (0.02) 8.7 (0.02) 12.0 (0.03) 20.4 (0.05) LEHE1219-01 Page 3 of 5

Package Performance Low Emissions Performance Standby Mission Critical Prime Continuous Frequency 50 Hz 50 Hz Gen set power rating with fan 3120 ekw 3120 ekw Gen set power rating with fan @ 0.8 power factor 3900 kva 3900 kva Emissions Low Emissions Low Emissions Performance number EM1364-02 EM1366-02 Fuel Consumption 100% load with fan L/hr (gal/hr) 828.5 (218.9) 828.5 (218.9) 75% load with fan L/hr (gal/hr) 658.5 (173.9) 658.5 (173.9) 50% load with fan L/hr (gal/hr) 454.4 (120.0) 454.4 (120.0) 25% load with fan L/hr (gal/hr) 261.2 (69.0) 261.2 (69.0) Radiator air flow restriction (system) kpa (in. water) 0.12 (0.48) 0.12 (0.48) Radiator air flow m 3 /min (cfm) 3334 (117739) 3334 (117739) Engine coolant capacity L (gal) 440 (116.2) 440 (116.2) Radiator coolant capacity L (gal) 845 (222.2) 845 (222.2) Total coolant capacity L (gal) 1285 (338.4) 1285 (338.4) Inlet Air Combustion air inlet flow rate m 3 /min (cfm) 305.5 (10786.9) 305.5 (10786.9) Exhaust System Exhaust stack gas temperature C ( F) 460.7 (861.2) 460.7 (861.2) Exhaust gas flow rate m 3 /min (cfm) 704.5 (24877.4) 704.5 (24877.4) Exhaust system backpressure (maximum allowable) kpa (in. water) 6.7 (27.0) 6.7 (27.0) Heat Rejection Heat rejection to jacket water kw (Btu/min) 1732 (98480) 1732 (98480) Heat rejection to exhaust (total) kw (Btu/min) 3034 (172533) 3034 (172533) Heat rejection to aftercooler kw (Btu/min) 374 (21288) 374 (21288) Heat rejection to atmosphere from engine kw (Btu/min) 196 (11145) 196 (11145) Heat rejection from alternator kw (Btu/min) 133 (7586) 133 (7586) Emissions (Nominal) NOx mg/nm 3 (g/hp-h) 2346.1 (4.99) 2346.1 (4.99) CO mg/nm 3 (g/hp-h) 255.0 (0.54) 255.0 (0.54) HC mg/nm 3 (g/hp-h) 43.0 (0.11) 43.0 (0.11) PM mg/nm 3 (g/hp-h) 4.6 (0.01) 4.6 (0.01) Emissions (Potential Site Variation) NOx mg/nm 3 (g/hp-h) 2815.3 (5.99) 2815.3 (5.99) CO mg/nm 3 (g/hp-h) 459.1 (0.98) 459.1 (0.98) HC mg/nm 3 (g/hp-h) 57.2 (0.14) 57.2 (0.14) PM mg/nm 3 (g/hp-h) 6.5 (0.02) 6.5 (0.02) LEHE1219-01 Page 4 of 5

Weights and Dimensions C A B Dim A Dim B Dim C Dry Weight kg (lb) 8397 (330.6) 3244(127.7) 3827 (150.7) 30 000 (66,200) Note: For reference only. Do not use for installation design. Contact your local Cat dealer for precise weights and dimensions. Ratings Definitions Standby Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby power rating. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Mission Critical Output available with varying load for the duration of the interruption of the normal source power. Average power output is 85% of the mission critical power rating. Typical peak demand up to 100% of rated power for up to 5% of the operating time. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year. Prime Output available with varying load for an unlimited time. Average power output is 70% of the prime power rating. Typical peak demand is 100% of prime rated ekw with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year. Continuous Output available with non-varying load for an unlimited time. Average power output is 70-100% of the continuous power rating. Typical peak demand is 100% of continuous rated kw for 100% of the operating hours. Applicable Codes and Standards AS1359, CSA C22.2 No100-04, UL142, UL489, UL869, UL2200, NFPA37, NFPA70, NFPA99, NFPA110, IBC, IEC60034-1, ISO3046, ISO8528, NEMA MG1-22, NEMA MG1-33, 2014/35/EU, 2006/42/EC, 2014/30/EU. Note: Codes may not be available in all model configurations. Please consult your local Cat dealer for availability. Data Center Applications Tier III/Tier IV compliant per Uptime Institute requirements. ANSI/TIA-942 compliant for Rated-1 through Rated-4 data centers. Fuel Rates Fuel rates are based on fuel oil of 35º API [16 C (60ºF)] gravity having an LHV of 42,780 kj/kg (18,390 Btu/lb) when used at 29ºC (85ºF) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.) C175-20 EL LEHE1219-01 (10-17) www.cat.com/electricpower 2017 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, ADEM, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.