Burst-Firing 74B5 LISTED INDUSTRIAL CONTROL EQUIPMENT. User Manual

Similar documents
Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

EUROTHERM FLEXIBLE SOLUTIONS SERIES POWER UNITS a choice for all load configurations

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Thyristor power units TC3000. Three-phase load control. User Manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

TC abc. Three phase thyristor for resistive, inductive and temperature dependent (complex) loads CONTROLS DATA MANAGEMENT PROCESS AUTOMATION

Packing Data Installation Instructions

INDUSTRIAL POWER SUPPLIES SFL-SERIES

CD3000S-1PH Thyristor Unit Heater Break version

EFit User Guide. Power Controller

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

CD3000S-1PH Thyristor Unit Analog Input version

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

The High Power Stack Horizon

SOLSTART Instruction Manual

SBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions

Switching DC Power Supply

LINE CONDITIONERS USER'S GUIDE

Solid State Relays contactor with Integrated Fuse Type RGC1F

Compact System NRGS 11-2 NRGS Original Installation Instructions English

GTS 15/25/40/50/60/75/90/120A

J TS 7090 Thyristor power switch

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Electromotoric Actuators

GTS-L4 5 / 10 / 15 TECHNICAL DATA

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

RVS-AX Instruction Manual

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Model Number Structure

Thick Film Chip Resistors

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

SAV Electronic Valve Actuator

Solid State Relays, 3-phase

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Sentronic LP IO-Link CLASS A 617 Series. 617 Series IO-Link CLASS A with Display and Controls Installation Manual

Electromotoric Actuators

DC/DC converters - MINI-PS DC/ 5-15DC/

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Appendix: Safety and application notes for... 15

DC POWER SUPPLY ALIMENTATION C.C.

Appendix: Safety and application notes for 19

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

REVO SSR, S1PH & A1PH up to 40A The solid-state relay evolution

SAX Electronic Valve Actuator

MC 1% Series Thick Film Chip Resistors

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

1204 Terminator. Instructions 1204 T F B2. (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used. What this Option Contains

Power Switching Principles

DX³ RCCBs - ID 4P up to 100 A

Declaration of Conformity

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

HIB Enclosed Inverter User Guide

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

SentronicPLUS IO-Link CLASS A Electronic Pressure Regulator. Installation Manual

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

771, 772, 773 Series Servovalves

1329I Integrated Drive/Motor CE Filter Option Kit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

SIRIUS 3RU2 Thermal Overload Relays

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Industrial Chargers and

film capacitors QUICK REFERENCE DATA Pilkor components FEATURES APPLICATIONS 10 and 15mm 22.5 and 27.5mm

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Technical Documentation

MINI MCR-SL-UI-UI(-SP)(-NC)

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

Differential pressure sensor

DIN EN UL 508 / CSA 3RF A A 0 2

UView Mini Transilluminator

AN INNOVATIVE ALTERNATIVE TO INDUSTRY STANDARDS

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Industrial Power Supplies

QF(19) - Series Miniature Circuit Breakers

MINI MCR-SL-UI-UI(-SP)

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Dimensions WxHxD [mm] Weight [kg]

D661-G...A Series Servovalve With Bushing and Integrated 24 Volt Electronics ISO 4401 Size 05

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

631 Series Servovalves ISO 4401 Size 05

Actuators for air dampers and control valves of oil burners

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

GQ 15 / 25 / 50 / 90 A SINGLE PHASE SOLID STATE RELAYS

D633/D634 SERVOVALVES FOR ELECTROHYDRAULIC POSITION, VELOCITY, PRESSURE OR FORCE CONTROL SYSTEMS WITH HIGH DYNAMIC RESPONSE REQUIREMENTS

530 Power. Grounding. Line voltage. Caution. A proper earth ground is required for GC operations.

Rental Industry Safety Tester Safe Check 5s

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Technical Data Sheets

Transcription:

TE10A Thyristor Power Controller Burst-Firing UL 74B5 C UL LISTED INDUSTRIAL CONTROL EQUIPMENT User Manual

TE10A Industrial thyristor power controller Burst-firing, Single-cycle or advanced Single-cycle CONTENTS SAFETY DURING INSTALLATION AND USE......... 3 EUROPEAN DIRECTIVES.......................... 4 TECHNICAL SPECIFICATION...................... 6 PRODUCT CODE.................................. 8 FUSES........................................... 8 CURRENT DERATING (as a function of ambient temperature)....................................... 8 INSTALLATION AND DIMENSIONAL DETAILS....... 9 FRONT FACIA................................... 10 TERMINALS AND CONNECTORS.................. 11 WIRING........................................ 12 Control of TE10A by temperature controller............ 12 Local control by potentiometer....................... 13 Local control by contacts............................ 13 Auxiliary power supply (option)...................... 14 INPUT SIGNAL.................................. 15 FIRING MODES.................................. 16 Burst firing....................................... 16 Single-cycle...................................... 17 Advanced Single-cycle............................. 18 CONFIGURATION OF FIRING MODE............... 19 Burst firing and standard Single-cycle (codes FC and FC1). 19 Advanced Single-cycle (code SCA)................... 20 For any further information, or if in doubt, please contact Eurotherm Controls wh e re qualified staff are ava i l able to advise or assist you with the commissioning of your installation. 2 User manual TE10A

SAFETY DURING INSTALLATION AND USE This symbol means that failure to take note of the information given in this manual may have serious consequences for the safety of personnel and may even result in electrocution. DANGER! Units must be installed in fan-cooled electrical cabinets to ensure that condensation and pollution are excluded. The cabinet must be closed and bonded to the safety earth in accordance with Standards NFC15-100, IEC 364 or current national Standards. It is the responsibility of the user to install and wire the installation in accordance with current professional practice. Before any connection or disconnection, make sure that power and control cables and leads are isolated from voltage sources. The safety earth must be connected before any other connection is made during wiring and should be the last cable to be disconnected. Thyristors are not isolating devices. The high-speed fuse recommended is used only to protect the thyristors: under no circumstances can it be used to protect the installation. For this reason it is very important to fit a suitable device guaranteeing protection for, and electrical isolation of, the installation in compliance with current practice. Access to the internal components of the product is prohibited to users Disconnect the TE10A completely before dismantling. The temperature of the heatsink fins may exceed 100 C. Avoid all contact, even occasional, with the heatsink while the TE10A is operational. The heatsink remains hot for approximately 15mins after the TE10A has been switched off. User manual TE10A 3

EUROPEAN DIRECTIVES CE MARKING TE10A products carry the CE mark in compliance with the essential requirements of the Low Voltage Directive 73/23EC of 19/2/73 (amended by the Directive 93/68/EC of 22/7/93). For safety reasons, TE10A products installed and used in compliance with this user manual meet the essential requirements of the European Directives mentioned above. CE DECLARATION OF CONFORMITY A CE Declaration of conformity is available on request. ELECTROMAGNETIC COMPATIBILITY (EMC) (For an industrial environment only, must not be used in domestic environments) Eurotherm certifies that TE10A Burst firing and Single Cycle fired products, installed and used in compliance with their manual, meet the following EMC standards and enable the system which incorporates them to comply with the EMC Directive as far as those TE10A products are concerned. EMC STANDARDS Immunity Generic standard: EN 50082-2 Test standards : EN 61000-4-2, EN 61000-4-4,EN 61000-4-5 ENV 50140, ENV 50141, ENV 50204 Emission Generic standard: EN 50081-2 Test standard : EN 55011 Product standard : IEC 1800-3 4 User manual TE10A

INTERNAL EMC FILTER An EMC filter is incorporated into the Burst firing and Single Cycle firing TE10A to reduce conducted emission in accordance with the EMC Directive. VALIDATION BY INDEPENDENT BODY Eurotherm has validated the compliance of these TE10A controllers with the Low Voltage Directive mentioned above and with EMC standards through product design and laboratory testing. The controls carried out on TE10A products are listed in a Technical Construction File validated by the LCIE (Central Laboratory for the Electrical Industries), a Recognised Competent Body. PRECAUTIONS Before installation, please read this manual thoroughly. Eurotherm cannot be held responsible for any damage to persons or property, or for any financial loss or costs arising from incorrect use of the product or failure to observe the instructions given in this manual. PERSONNEL The installation, configuration, commissioning and maintenance of the power unit should only be carried out by personnel qualified and trained to work with low voltage electrical equipment in an industrial environment. INDEPENDENT SAFETY DEVICE Given the value of the equipment controlled by TE10A, it is the responsibility of the user, and it is highly recommended, that an independent safety device (alarm) should be installed. This alarm must be tested regularly. Eurotherm can supply suitable equipment. 'ELECTROMAGNETIC COMPATIBILITY' INSTALLATION GUIDE In order to help you reduce the effects of electromagnetic interference depending on the product installation, Eurotherm can supply you with the 'Electromagnetic Compatibility' Installation Guide (ref. HA025464). User manual TE10A 5

TECHNICAL SPECIFICATION Power Nominal current at 45 C 16, 25 or 40A. Nominal voltage 100Vac to 500Vac +10%, -15% Supply frequency 50 or 60Hz (nominal) ±2Hz Current in off state Below 30mA typically Regulation Type of regulation The load power is proportional to the control input Linearity Stability Firing modes Firing indicator Control Inputs External signal type Input impedance Local control CE marking Electrical safety 6 Better than ±2% of the full range Automatic compensation for supply variations from ±10% of the nominal voltage. Stability better than ± 2% of the full range on constant resistance Thyristor firing at zero voltage Burst mode: firing and non-firing over a whole number of mains cycles Single-cycle: firing or non-firing for one mains cycle Advanced Single-cycle: firing over a whole number of mains cycles, non-firing over a whole number of half cycles Green LED on front facia Analogue, DC voltage or current: 0-5V, 0-10V or 4-20mA Voltage 100KΩ, current 250Ω External potentiometer 10k 'Dry' contact: logic operation - 'all or nothing' A '5V user' voltage is available The CE Mark in accordance with the Low Voltage Directive 73/23/EC amended by the Directive 93/68/EC of 22/7/93 User manual TE10A

EMC Environment Operating temperature Operating atmosphere These TE10A products comply with Electromagnetic Compatibility test standards (see page 4) 0 to 60 C, (see derating curves) at maximum altitude of 2000m Storage: -10 to +70 C Non-conductive, non-explosive and noncorrosive RH: 5 to 95%, non-condensing Humidity Pollution Pollution degree 2 permissible (IEC 664) Thyristor protection External fuse, internal MOV (varistor) and RC snubber Protection degree IP20 (in accordance with IEC 529; 11.4, table 5) Isolation distances according to IEC 664 Insulation (1 minute test) Cooling Mounting Option Auxiliary power supply Wiring Guarantee 2000Vac between power and earth 3600Vac between power and control inputs Natural convection Vertical on DIN rail 115Vac or 230Vac used in the case of nonstandard mains or if independent power supply required The separate auxiliary power supply must be in phase or anti-phase with the load supply Two years for parts and labour (return to factory) In order to maintain its leading edge Eurotherm may have to make changes to its specifications without advance notice. For any further information, or if in doubt, please contact Eurotherm Controls. User manual TE10A 7

PRODUCT CODE Model / Current / Voltage / Input / Firing /Option / 00 TE10A 16A 100V 415V 0V5 Separate 25A 115V 440V 0V10 Single-cycle: power 40A 200V 480V 4mA20 FC1 Supply 230V 500V Advanced 115V 240V Single-cycle: 230V 277V SCA* 380V Burst-firing: 400V FC * SCA mode uses different firing board THYRISTOR PROTECTION FUSES (Thyristor protection except for short-wave infrared application) Current Rating Code (Fuse & fuse-holder) Dimensions (mm) 16A 20A FU1038 / 16A / 00 81 x 17.5 x 68 25A 32A FU1038 / 25A / 00 81 x 17.5 x 68 40A 50A FU1451 / 40A / 00 95 x 26 x 86 CURRENT DERATING (as a function of ambient temperature) Dotted line ( ): limit of recommended fuse 50 40 30 20 10 I eff(a) IN = 25 A I N = 16 A I N : nominal current at 45 C IN = 40 A Ambient temperature ( C) 0 20 25 30 35 40 45 50 55 60 8 User manual TE10A

INSTALLATION AND DIMENSIONAL DETAILS Minimum spacing between 2 TE10A units: 10mm up to 45 C 17 5mm over 45 C Dimensions (in mm) DIN rail clip mounting (EN 50022-35 x 7 5 and 35 x 15) Ground continuity: For reasons of electromagnetic compatibility ensure that the metal DIN rail of the TE10A installation is electrically bonded to the reference ground (panel or bulkhead). User manual TE10A 9

FRONT FACIA 10 User manual TE10A

TERMINALS AND CONNECTORS Power terminal block: cage terminals for 1.5 to 16mm 2 cables, strip insulation by 16 mm, tightening torque 1.2 Nm. Safety earth wiring: same section as power conductor, tightening torque 2 Nm. Control connection to terminals 5 & 6, and separate auxiliary power supply connection (option) to terminals 8 & 10: use 0.5 to 1.5 mm 2 wire, strip insulation by 7 mm, tightening torque 0.4 Nm (0.25 Nm for terminals 8 & 10). View from below User manual TE10A 11

WIRING Control of TE10A by temperature controller L N Line protection circuit breaker (installed by user) 1A fuse Thyristor protection fuse Controlled phase Neutral Temperature controller EUROTHERM 2216 L N E V+ 1A 1B V- Firing indicator EUROTHERM ON - + 5V 1 2 1 TE10A 5 6 7 3 ε 2 4 3 4 Analogue output Thermocouple input Analogue input 5 6 7 0V + Example of wiring for TE10A (240V nominal, input 0 to 10V) controlled by Eurotherm 2000 series temperature controller. 12 Load Safety earth User manual TE10A

Local control by potentiometer The input must be configured as 0 to 5V (code 0V5). Local control by contacts The input must be configured as 0 to 5V (code 0V5). User manual TE10A 13

Auxiliary power supply (option) Use of TE10A with non-standard mains. Example of separate auxiliary power supply wiring (option). The auxiliary power supply must be in phase or in anti-phase with the load supply. 14 User manual TE10A

FIRING MODES Three firing modes are possible: Burst firing, Single-cycle and advanced Single-cycle. Thyristor firing and quenching occurs at zero voltage which minimises interference to the supply network. Burst firing Burst firing mode consists of supplying a series of whole mains cycles to the load. The load power is proportional to the ratio of the firing time (T F ) to the modulation time (T M ). The OFF time (T NF ) is also a series of whole mains cycles. T M = T F + T NF The period of modulation is variable according to the output power demand. At 50% of nominal power the thyristors are on for 300ms ±100ms and are off for 300ms ±100ms (at 50 Hz) For a setpoint less than 50%, the non-firing period increases, and the firing period is fixed (300ms ±100ms) For a setpoint greater than 50%, the firing period increases, and it is the non-firing period which is fixed (300ms ±100ms) 16 User manual TE10A

Single-cycle The mode of firing with only one firing or non-firing mains cycle is called Single-cycle. At 50% of nominal power the thyristors are on for 20ms and are off for 20ms (at 50Hz) For a setpoint less than 50% the non-firing period increases and the firing period is fixed at 20ms For a setpoint greater than 50% the firing period increases and it is the non-firing period which is fixed at 20ms. User manual TE10A 17

Advanced Single-cycle (Uses different board) In order to minimise power fluctuation during the modulation period, the advanced Single-cycle mode uses half-cycles for non-firing. Examples of firing in Single-cycle (a) and in advanced Single-cycle (b) modes at 66.6% of nominal power. For a setpoint less than 50%, firing is effected on mains halfcycles. The firing time is fixed at one cycle (20ms at 50Hz) For a setpoint greater than 50%, non-firing is reduced to one halfcycle. Firing is effected over whole cycles. The use of half-cycles for non-firing is the reason for the reduction in flicker and brightness of infrared elements compared with Singlecycle. 18 User manual TE10A

Solid State Contactors TE10S Power Controllers TE10A ε E U R O T H E R M ADDENDUM TE10S User Manual Part N : HA174780ENG, HA174782ENG, HA174784ENG, HA175436ENG TE10A User Manual Part N : HA175247ENG, HA175548ENG NOMINAL CURRENT UP TO 50 A and SHORT WAVE INFRARED APPLICATIONS Copyright Eurotherm Automation S.A. 1997 All rights strictly reserved. No part of this document may be stored in a retrieval system, or any form or by any means without prior written permission from Eurotherm Automation SA. Part N. HA175600 ENG - Issue 2.0-12/98

TECHNICAL SPECIFICATION MAXIMUM CURRENT In order to take into account supply voltage variations and heating element resistance dispersion (all types of heating elements including short wave infrared), a 0.8 safety coefficient must be used on the thyristor unit current rating to determine the maximum value of the load nominal current which the unit can safely control. SHORT WAVE INFRARED (SWIR) APPLICATIONS Applications using short wave infrared heaters in Single Cycle, Fast Cycle or Advanced Single Cycle are reserved to 16 A, 25 A and 40 A current rating. With a safety coefficient of 0.8 the maximum current for SWIR which can be controlled is: TE10 rating SWIR maximum controlled current 16 A 13 A 25 A 20 A 40 A and 50 A 32 A 2 Addendum TE10 (50A/SWIR)

RANGE DIMENSIONS AND WEIGHT Height 115 mm / Depth 92.5 mm Models Nominal current Width (mm) Weight (g) TE10S/DC, TE10S/AC TE10S/PDSIO 16 A 25 A 40 A 50 A 35 52.5 87.5 105 350 500 850 1100 TE10S/PLF TE10A/Burst TE10A/PA 16 A 25 A 40 A 50 A 52.5 70 105 122.5 550 700 900 1200 THYRISTOR PROTECTION FUSE TE10 rating 16 A 25 A 40 A 50 A Fuse rating 20 A 32 A 50 A 63 A Fuse & fuse-holder Code Dimensions(mm) FU1038/16A/00 81 x 17.5 x 68 FU1038/25A/00 81 x 17.5 x 68 FU1451/40A/00 95 x 26 x 86 FU2258/50A/00 140 x 35 x 90 Attention! Addendum TE10 (50A/SWIR) For SWIR applications, the high-speed fuse must not be used 3

60 I RMS (A) IN = 50 A 50 IN = 40 A 40 30 IN = 25 A 20 IN = 16 A 10 0 20 25 30 35 40 45 50 55 60 Operation tempereature ( C) Current derating as a fonction of ambient temperature (I N = nominal current at 45 C) Dotted line : limit due to recommended fuse 65 70 4 Addendum TE10 (50A/SWIR)

Eurotherm: International sales and service AUSTRALIA Sydney T (+61 2) 9838 0099 E info.au@eurotherm.com AUSTRIA Vienna T (+43 1) 7987601 E info.at@eurotherm.com BELGIUM & LUXEMBOURG Moha T (+32) 85 274080 E info.be@eurotherm.com BRAZIL Campinas-SP T (+5519) 3707 5333 E info.br@eurotherm.com DENMARK Copenhagen T (+45 70) 234670 E info.dk@eurotherm.com FINLAND Abo T (+358) 22506030 E info.fi@eurotherm.com FRANCE Lyon T (+33 478) 664500 E info.fr@eurotherm.com GERMANY Limburg T (+49 6431) 2980 E info.de@eurotherm.com HONG KONG & CHINA T (+85 2) 28733826 E info.hk@eurotherm.com Guangzhou Office T (+86 20) 8755 5099 E info.cn@eurotherm.com Beijing Office T (+86 10) 6567 8506 E info.cn@eurotherm.com Shanghai Office T (+86 21) 6145 1188 E info.cn@eurotherm.com INDIA Chennai T (+91 44) 24961129 E info.in@eurotherm.com IRELAND Dublin T (+353 1) 4691800 E info.ie@eurotherm.com ITALY Como T (+39 031) 975111 E info.it@eurotherm.com KOREA Seoul T (+82 31) 2738507 E info.kr@eurotherm.com NETHERLANDS Alphen a/d Rijn T (+31 172) 411752 E info.nl@eurotherm.com NORWAY Oslo T (+47 67) 592170 E info.no@eurotherm.com POLAND Katowice T (+48 32) 2185100 E info.pl@eurotherm.com SPAIN Madrid T (+34 91) 6616001 E info.es@eurotherm.com SWEDEN Malmo T (+46 40) 384500 E info.se@eurotherm.com SWITZERLAND Wollerau T (+41 44) 7871040 E info.ch@eurotherm.com UNITED KINGDOM Worthing T (+44 1903) 268500 E info.uk@eurotherm.com www.eurotherm.co.uk U.S.A. Leesburg VA T (+1 703) 443 0000 E info.us@eurotherm.com www.eurotherm.com Equipment made in a certified ISO9001 factory. Copyright Eurotherm Automation SAS 1996 All rights reserved. User Manual TE10A/BUR - HA175247ENG