Linear fittings EVDL LED fitting - zones 21, & 22

Similar documents
Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVTL Weatherproof LED fitting - Industrial applications

Linear fittings EVNL LED fitting - zones 2, & 22

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Linear fittings EVN Fluorescent fitting - zones 2 & 22

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Linear fittings EVD Fluorescent fitting - zones 21 & 22

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Linear fittings EVT Weatherproof fluorescent fitting - Industrial applications

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Luminaire with LED Series EXLUX 6409/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Floodlight LED Series 6125

Linear Luminaire with LED Series EXLUX 6002

EXEL-L. Detail of the internal side. Transparent polycarbonate

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

Linear luminaire with LED Series EXLUX 6002

Floodlight LED Series 6525

Floodlight LED Series 6525

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

LED Linear Luminaire Series EXLUX 6402

Compact Sheet-Steel Light Fittings Series 6114/1

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Easy and safe installation

Floodlight fittings HPS, MH or Halogen Floodlight fitting XSF, XQF, XEF - Zones 1, 2

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Start Waterproof LED G3 fixed output START WATERPROOF LED G3 1500MM T 4K

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

FL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22

Linear fluorescent luminaire LED V-CG-S

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Lighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Floodlight Series 6121

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

ATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

PROTECTA III. Construction Tough glass reinforced polyester body

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

7 Lighting Technology

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Tubular Light Fitting with LED Series 6036

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Operating Instructions

Zone 1 Linear Range - Installation Guide

TUNNEL54. Safety and fire resistance VENTILATION LIGHTING

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

EX-REPAIR AND MAINTENANCE RECEPTACLES

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

explosive environments Lighting

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

Compact Sheet-Steel Light Fittings Series 6114

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Areamaster LED Flood/High Bay Luminaires For Hazardous Locations. 250 W, 400 W, 750 W, 1000 W HID Light Level Equivalent

ATX DPD Series Distribution Panelboards Flameproof

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

PRODUCT BROCHURE. Light fittings, floodlights & beacons LED range for explosive atmospheres

HTSB system System overview

FHL. Ex d. Body in aluminium

Panelboards & Motor Starters

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

The ultimate low voltage temporary LED lighting solution

A good connection. International approvals.

TECHNICAL DATASHEET. Weatherproof LED luminaire DUNA FLEX High Efficiency. 70,000 h product life IK C. Applications recommendation

The ultimate low voltage temporary LED lighting solution

Start Waterproof LED START WATERPROOF LED 1265MM TWIN 4000K PRODUCT OVERVIEW

Sheet-Steel Light Fittings Series 6014 / 6414

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

ABG Cable Glands Installation Procedure

Transcription:

ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted on hinged and removable gear tray which gives easy access for maintenance Including accessories (cable gland, plugs & fixing brackets) EVDL LED fitting Approvals & certifications Extb IIIC D GROUP II ZONE 21 ZONE 22 Specifications Main body constructed of glass-reinforced polyester for high impact strength UV protected polycarbonate diffuser to resist harsh environments Rated voltage 100-240Vac 50-60Hz Wiring configuration: 5 wires 3x entries M20 Approved to: ATEX Directive (2014/34/EU) Photobiological safety EMC Directive (2014/30/EU) Standards EN 60079-0: General requirements EN 60079-31: Enclosure t LCIE 11 ATEX 3092X IEC Ex LCI 11.0064X II 2 D Ex tb IIIC T85 C Db for -40 C to +60 C Ex tb IIIC T65 C Db for -40 C to +35 C IEC62471 Exempt group EN 55015: Conducted emission test and radiated emission test EN 61547: CEM immunity EN 61000-3-2: Harmonic current Emissions Class C IP 66 IK 10 EN 61000-3-3: Limitation of voltage changes and flickers Low voltage Directive (2014/35/EU) EN 60598-1: Luminaire general requirements and tests, including dielectric strength and isolation resistance Glow wire test: 960oC Operating temperature: -20 C to +55oC 01 Hinged & removable gear tray IP test: Impact protection index: IEC 60529: IP66 IEC 62262: IK10 01

78 ABB DTS LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Linear fittings EVDL LED fitting - zones 21 & 22 EVDL Linear LED fitting 5 wires Glass Diffuser Suitable for use in Zones 21 & 22 Dimensions 2 x M8 hole 20mm depth 2 trous M8 prof. 20mm 2xM8 holes 20mm depth C B C B EVDL 5 wires: Equipped with 1 cable gland & 2 plugs A A 137 mm 137 170 mm 170.5 Type For Operating life Dimensions mm Wiring Light Current A Lumen Efficiency Weight non armored cable armored cable Configuration Rating W @ 230V Output lm at C at 55 C Lm/W A B C kg EVDL120-0000 EVDL120-D000 5 wires* 12 0.07 1287 100000 45000 107 785 432 400 4.00 EVDL140-0000 EVDL140-D000 5 wires* 0.12 08 90000 75000 100 1370 900 700 6.80 EVDL165-0000 EVDL165-D000 5 wires* 31 0.16 2799 80000 60000 90 1670 900 700 8.20 EVDL220-0000 EVDL220-D000 5 wires* 19 0.10 1755 80000 35000 92 785 432 400 4.40 EVDL240-0000 EVDL240-D000 5 wires* 56 0.27 4421 70000 50000 79 1370 900 700 7.60 EVDL265-0000 EVDL265-D000 5 wires* 71 0.34 5262 70000 50000 74 1670 900 700 8.80 EVDL 5 wires through: Equipped with 2 cable glands & 1 plug EVDL120-B000 EVDL120-E000 5 wires** 12 0.07 1287 100000 45000 107 785 432 400 4.00 EVDL140-B000 EVDL140-E000 5 wires** 0.12 08 90000 75000 100 1 370 900 700 6.80 EVDL165-B000 EVDL165-E000 5 wires** 31 0.16 2799 80000 60000 90 1 670 900 700 8.20 EVDL220-B000 EVDL220-E000 5 wires** 19 0.10 1755 80000 35000 92 785 432 400 4.40 EVDL240-B000 EVDL240-E000 5 wires** 56 0.27 4421 70000 50000 79 1 370 900 700 7.60 EVDL265-B000 EVDL265-E000 5 wires** 71 0.34 5262 70000 50000 74 1 670 900 700 8.80 Note. * For armored cable with 1 continuity plate. ** For armored cable with 2 continuity plates. Technical information LED installed Set of LED modules with integrated diffuser Colour temperature 4000 K L70/B10 at C (70% lumen output/ 90% active LED) according to operating life Photometric curve See page 182 Rated voltages Electronic driver: 100-4Vac 50/60Hz Power factor 0.9 CRI 84 Wiring Configuration Electrical protection class Inrush current 5 wires for the part EVDL240 I peak = 60A @230Vac delta t = 275µs Max. light fittings per circuit breaker Type 10A 16A 20A A B 4 7 9 11 C 7 12 15 18 I Technical information Grounding system Terminal block (screws plug in terminal block) Cable entries For non-armoured cable: For armoured cable: Housing Fixing (included with product) TNS, TNC, TT, IT neutral system 2.5mm² rigid or flexible Terminals supplied L1, L2, L3, N, PE (looping possible with one additional cable gland) Three entries M20 Included two M20 nylon plugs (EX-M20) and one M20 nylon cable gland, diameter 6-12mm (EXCGM20S) and three nylon locknuts included continuity plate - two M20 nylon plugs (EX-M20) and one M20 nickel plated brass cable gland, diameter 6-12/ 8.5-16mm (EXN04MMC1K) Glass reinforced polyester housing for high impact strength, UV protected polycarbonate diffuser to resist harsh environments, White painted steel gear tray & 2x M8 Stainless steel 316L insert V015-2x Two zinc-plated steel brackets for ceiling mounting

ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 79 Fluorescent fitting to a LED fitting 01 ht source : 2 x L36W/840 OSRAM Lumilux Coolwhite 20mx20m ht 5m 01 T8 fluorescent lamp 3d photometric data 02 LED module 3d photometric data 03 Remove existing fluorescent gear tray What are the LED benefits? The benefits of the LED technology consist in a significant improvement in the life expectancy of your product, lower power consumption and the improvement of the photometric features. 02 2,50 5 7,50 10 15 20 40 60 80 lx Light source : 1 x LED 04 Replace with LED gear tray with driver 05 Connect LED gear tray to power supply T8 fluorescent lamp - EVD240-000J0 3D view Lumen output (light fitting): 4493 lm Lumen output (lamp): 5878 lm Yield: 76.4% Rating per light fitting: 63.5% Light source: 2x L36W/840 OSRAM Lumilux Cool White (corrector factor 1.00) LED module - EVDL240-00000 3D view Lumen output (light fitting): 4421 lm Lumen output (lamp): 4511 lm Yield: 98% Rating per light fitting: 56.8W Light source: 1x LED module (corrector factor 1.00) MRO benefits How can I upgrade my current light fitting? Tubular fittings could be switched from fluorescent to LED technology by easy sliding gear tray without any specific tool. The fixture with 1 or 2 fluorescent tubes T8 could be replaced by only one LED module fixed on the new gear tray. 2,50 5 7,50 10 15 20 40 60 80 lx 20mx20m ht 5m How is my upgraded LED light fitting certified? ATEX and IECEx certificates, EU declaration and the installation notice of the fluorescent fitting remain valid for all the LED fittings (more details on demand). Gear trays parts to upgrade from a fluorescent to a LED fitting - LED gear tray with driver 100-240Vac 50/60Hz: V0041X20WEL - To upgrade EVD120 to EVDL120 V0041X40WEL - To upgrade EVD140 to EVDL140 V0041X65WEL - To upgrade EVD165 to EVDL165 V0042X20WEL - To upgrade EVD220 to EVDL220 V0042X40WEL - To upgrade EVD240 to EVDL240 V0042X65WEL - To upgrade EVD265 to EVDL265 03 04 05

80 ABB DTS LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Linear fittings - accessories EVDL - zones 21 & 22 Fixing accessories* Brackets Type Specifications V015 2 x pair of zinc plated steel for ceiling mounting (Included with product) ø9 V016 Stainless steel 316L brackets for ceiling mounting 160 200 Hook Type Specifications 20 V024 2x Zinc plated steel suspension hook M Mounting bracket clip Type Specifications V014 2x Rapid ceiling mounting with stainless steel clip 60, 2 Ø 8.5 Fixing bracket and flange Type Specifications V018 2x zinc plated steel pole mounted brackets for ø1 ¼ & 1 ½ 100 M8 V019 2x zinc plated steel pole mounted brackets for ø2 V021 2x Stainless steel 316L pole mounted brackets for ø1 ¼ & 1 ½ V022 2x Stainless steel 316L pole mounted brackets ø2 α ø9 ~70 41 * Screws and locknuts supplied

ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 2 & 22 81 Linear fittings - spare parts EVDL - zones 21 & 22 Spare parts Type Specifications V001 V004 V00120W V00140W V00165W V0041X20WEL V0041X40WEL V0041X65WEL V0042X20WEL V0042X40WEL V0042X65WEL 20W diffuser with gasket for EV. range 40W diffuser with gasket for EV. range 65W diffuser with gasket for EV. range Gear tray 12W with driver 100-4Vac 50-60Hz and bracket kit of gear tray for EVDL120 Gear tray W with driver 100-4Vac 50-60Hz and bracket kit of gear tray for EVDL140 Gear tray 31W with driver 100-4Vac 50-60Hz and bracket kit of gear tray for EVDL165 Gear tray 19W with driver 100-4Vac 50-60Hz and bracket kit of gear tray for EVDL220 Gear tray 56W with driver 100-4Vac 50-60Hz and bracket kit of gear tray for EVDL240 Gear tray 71W with driver 100-4Vac 50-60Hz and bracket kit of gear tray for EVDL265 V020x40W Brass continuity plate for EV. 120, EV. 220, EV. 140, EV. 240 V065W Brass continuity plate for EV. 165, EV. 265 EXCGM20S EXN04MMC1K M20 Exe IIC nylon cable gland for non armoured cable diameter 6-12mm, locknut available separately as LNPB/M20 Kit M20 Ex-d IIC Ex-e II Ex-td double compression nickel plated cable gland for armoured cable diameter inner 6-12 outer 8.5-16mm locknut, sealing gasket