User Instruction SUPER-PM ATEX. Note! Before installation and use in application follow the instructions

Similar documents
Pneumatic Axial Fan Type Tech. Doc. No. 802

Product manual Extraction arm KUA

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 SYSTEM 100 AL. Alsident System100. Aluminium (AL) Product Information

Operating Instructions

Control and Terminal Box Type A21-**-*****

Operating Instructions

Operating instructions

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Flameproof Enclosures

INSTRUCTION MANUAL MAGNA RAIL

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75. Alsident System 100. Chemical Resistant (CR) Product Information SYSTEM 100 CR

Chargestar T26 / T45. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Instruction Manual ATEX Addendum to STP Manual

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Instruction Manual. Back Pressure Regulator (Low Shear ¾ ) Bar Pilot Control

Operating instructions

Operating instructions. METTLER TOLEDO MultiRange Floor scales/pit scales

DC Master 24/ A

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics

How to Use a Chemical Fume Hood Safely

Instruction Manual. Ex-Time 40 / 50

Alsident System 50 Flex

ALSIDENT SYSTEM 75. Easily positioned all-round fume extraction arm

FlexPAK 800 DX. The leading extraction solution. Always the right capacity.

MANUAL. Single charger

SYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 PP SYSTEM 100 ALSIDENT SYSTEM 75. Chemical Resistant (CR) Product Information

Lighting series JSNEVW Lighting series JLEDW LEUCHTEN 2011/09

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Number: TEPEx.RS.067 Rev : 02 Date: Manufacturer General safety information s Purpose Degree of protection 2.

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

ILED Dorado. User Manual

Operating Instructions

IQL Helios Area-/Streetlight. User Manual

Ex m Solenoid Operator Type 0519

ALFRA Akku-Compact Flex Handstanze Art.-Nr / Prod.-No / N art / Nº de prod

US - UP2/OIL 12V US - UP2/OIL 24V

INSTRUCTION MANUAL IS2.003

Extraction arm FX100 Original

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Battery Charger. Series EASY Charger. User s manual

Extraction Arms. Capturing fumes at the source

Operating Instructions

AXIAL FANS Axis / Tubo OPERATION MANUAL

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PUA574 / PUA579(x)

Installation Instructions. Install Hubs Set Spacing Install Element FINISHED BORE INTERFERENCE FIT. Step 1 - HUB INSTALLATION

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

Operating Instructions

Ex e, ia Junction boxes TNCN. Features

Proportional Solenoid for Hydraulics ATEX + IECEX

SUBMERSIBLE WATER PUMP

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Centrifugal fan with highly efficient EC drive motor

MULTI FUNCTION POWER PAK PLUS

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

Original Operating Manual

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

DIAMOND POINT VIBRATING PROBES

Pumps and pumping units SL i & Micro C

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

FTM-TECHNOLOGIES : 78, rue Raymond Poincaré Nanterre FRANCE Tél Fax:

OPERATION MANUAL FLG-G5-14 Transtech Gravity Spraygun

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Pneumatic Rotary Actuator DSO-P. Hydro-Pneumatic Actuator DSO-H

BOXAIR M2 Mobile Filter Unit. User s Manual.

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

SCOPELITE TIMING LIGHT OPERATING MANUAL

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Pendant Light Fitting IEC

HST-BL-2830MS & HST-BL-2830MS-USA

FilterBox Wall. Automatically or manually cleaned for dust & fume applications.

Battery Charger Series EASY Charger

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

Operating Instructions Inline Detonation Flame Arrester and

SPARK PLUG CLEANING KIT OPERATING MANUAL

Industrial Vacuums ATEX IECEX certified

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Small Geared Motors Series G2

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Swing Piston Compressors and Vacuum Pumps

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

EXTRACTION ARMS. Capturing fumes at the source

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

BATTERY CHARGER-STARTER

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Solenoid Operator 0516 / 1216

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

12V OIL & DIESEL PUMP MODEL NO: CFTP12

Solenoid Operator 0513 / 1213

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

manual addendum ROBUS Ex

Operation Manual Cobra 1 Automatic Spray Gun

Transcription:

User Instruction SUPER-PM ATEX Note! Before installation and use in application follow the instructions PLYMOTH-PLYMEX GmbH Zilzkreuz 14 53 604 Bad Honnef Tel.: 02224/98853-0 Fax: 02224/98853-22 e-mail: info@plymoth.de Internet: www.plymoth.de Geschäftsführer Jan Plymoth HRB 8705

List of Contents 1. User regulations 2. Safety 3. User instructions 4. Installation Instructions 5. Ensure of the electric ground connection 6. Additional control before use the product 7. Spare part 8. Maintenance 9. Declaration of conformity

1. User regulations The earthed Super PM in combination with an antistatic hose for extraction of explosive gas in zone 1 and 2 as well as dust for zone 21 and 22. Equipment group II Equipment category 2 Apart from the general given in our instructions it is necessary to perform a risk analysis for the particular work processes that going to be done in each individual case. If this is not done the safety of the workplace can not be guaranteed. The final responsibility for safety can only be taken by the owner of the installation 2. Safety The product is designed to meet the requirements of the relevant EC directives. To maintain this status all installations, repair and maintenance work must be carried out by qualified personnel using only original spare parts. Contact you nearest authorised dealer or Plymoth Plymex GmbH for advise WARNING! Ignition risk for some dust or solvents Check that no objects which can cause sparking or fire are sucked into the arm. Avoid impacts against hood. Avoid mixing dust from different processes. 3. User instruction Super PM are designed for capture dust, fumes and gases and the arm can easily be positioned at any point within the working area. For the best capture efficiency, the hood should be positioned as near the fume or dust generating process as possible. Always dimension your systems so the airflow is sufficient for the application in question Recommended airflow Maximum: 950 m³/h for models with hose diameter 110 mm and 1600 m³/h for models with hose diameter 160 mm For additional advise contact authorized dealer or Plymoth Plymex GmbH

4. Installation instructions Mounting Instruction Extraction Arm 2 x bakelit washer Bolt M10 Spring washer Assembly 1. Mount the wall bracket 2. Mount the parallelogram arm 3. Mount the hood 4. Fasten the hose Spring washer Steel washer Nut M10 Nut M8 Spring washer 2x Bakelit washer Bolt with U-washer = M8 Note! The frame is factory balanced. No adjustments should be done.

5. Ensure of the electric ground connection The earthling of hose material should be done over the contact surfaces between the hose and the ducting. On the contact surfaces 1.see below, expose both the ends of the spiral and earth them to the duct and hood points. 1. 1. 6.Additional control before using the product Test the electrical potential.

7. Spare part Spare parts Super-PM Ø 110/160mm With mirror polished acid proof stainless steel hood and handle Only use original Spare parts to maintain the status of the installation 7:1+2 4 1 8 2 5 3 6:1 6:2 6:3 6:4 No Description 1,5 m 2 m 3 m 4 m 1 Wallbracket 0,25 m OM-002 OM-002 OM-002 2 Wallbracket 0,5 m OM-003 OM-003 OM-003 OM-003 3 Horizontalboom 0,5 m OM-005 4 Parallelogramarm R-131 R-132 R-133 R-133 5 Set of 2 Hydraulic springs R-087 R-088 R-089 R-089 6:1 Hood straight ø110 mm (stainless) R-112 R-112 R-112 R-112 6:2 Hood 67 ø 110 mm- (stainless) R-113 R-113 R-113 R-113 6:3 Hood 150 ø 110 mm (stainless) R-114 R-114 R-114 R-114 6:4 Hood ø 160 mm (stainless) R-115 R-115 R-115 R-115 7:1 Hose ATEX ø 110 mm R-119 R.120 R-121 R-122 7:2 Hose ATEX ø 160 mm R-123 R-124 R-125 R-126 8 Handle (stainless) R-134 R-134 R-134 R-134

8. Maintenance We recommend regular safety controlat least once a year on following points: Control the hose,no damages etc. Control bakelite washers,screws Control of the earthing 9. Declaration of conformity The Plymoth Plymex GmbH ATEX Super PM Models confirm the following directives,underlying Standards and other Normative documents. EN 292-1:1991,EN 292-2 :1991, following the Provisions of Directive 98/37/EG,ATEX 94/9/EC. PLYMOTH-PLYMEX GmbH Zilzkreuz 14 53 604 Bad Honnef Tel.: 02224/98853-0 Fax: 02224/98853-22 e-mail: info@plymoth.de Internet: www.plymoth.de Geschäftsführer Jan Plymoth HRB 8705