FINANCIAL BID NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH

Similar documents
SCHEDULE OF QUANTITY

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

sl. No Description Unit Qty Rate (Rs) Amount (Rs)

STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA. ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ)

SCHEDULE OF QUANTITIES FOR THE ELECTRIFICATION STRUCTURED / DATA CABLING WORKS FOR THE FEDERAL BANK'S

1 SITC of Surge protector OBO BETTERMAN V25-B+C/3+NPE with manufacturer's enclosure, 3 phase 415 V. no 1. No 1

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

ESTIMATE FOR ELECTRICAL WORKS AT CHINCHOLI BRANCH

M. C. B. / D. B./MCCB : MDS/Schneider/Siemens/havells

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH

B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH

PART B: FINANCIAL BID

STATE BANK OF INDIA INFRA MANAGEMENT SOLUTION (P) LTD BOQ- ELECTRICAL WORKS OF KATKOL BRANCH, RBO-2, AO-7

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB /

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. CIRCLE OFFICE, AHMEDABAD STATE BANK OF INDIA, RBO-II, C.N. VIDYALAYA CAMPUS, AMBAWADI, AHMEDABAD

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.

Estimate For Electrical Works PROPOSED RUDSET INSTITUTE AT BERHAMPUR

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises

PART A: FINANCIAL BID

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu.

ESTIMATE PROPOSED ELECTRICAL & ALLIED WORKS FO INDIA ONE AVIGHNA PARK, CURREY ROAD BRANCH AT C MUMBAI

TENDER DOCUMENT PART-II

SCHEDULE OF QUANTITIES OF ELECTRICAL WORKS FOR BOI, ZO, JODHPUR. PART - II

SBI, DHROLL BRANCH, DIST. JAMNAGAR - ELE. INST. WORK - OCT. 2018

Corrigendum-I. Bill of Quantity

ESTIMATE: ELECTRICAL AND DATA CABLING WORK SBI Panchanan Bhawan Bhopal (M.P)

SBI INFRA MANAGEMENT SOLUTIONS PVT.LTD. PART B: FINANCIAL BID. Proposed Electrical Work For SBI Ramdaspeth Branch, Nagpur. S. NANDEDKAR & ASSOCIATES

STATE BANK OF INDIA BOQ FOR THE ELECTRICAL 74 JANPATH BRANCH. S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT

TENDER DOCUMENTS FOR ELECTRICAL WORKS STATE BANK OF INDIA

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

FORMAT-III B - ANNEXURE-III

FORMAT B (Annexure-III)

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

Amount (Rs) 1.5 sq. mm ISI marked, FR

FORMAT-III B - ANNEXURE-IV

PUNE EAST ZONE - BANK OF MAHARASHTRA Kesari Wada, Narayan Peth, Pune

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm

Annexure- II (Price Bid) SCHEDULE B LIST OF ELECTRICAL ITEMS TO BE SUPPLIED

STATE BANK OF INDIA ESTIMATE FOR THE ELECTRICAL

Electrical BOQ for P Block Connaught Place Branch S.No. DESCRIPTION OF WORKS UNIT QTY RATE AMOUNT

ZONAL OFFICE KEONJHAR ZONE

T. No 03/ /Eldb

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO

Section VI: List of Requirements (REVISED)

Rate. Sl No. Description of item Unit Qty

List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole

INDIAN INSTITUTE OF TECHNOLOGY GUWAHATI Guwahati Phone : (0361) , Fax : (0361)

KERALAM MUSEUM OF HISTORY & HERITAGE

TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION. DG Sets & Sychronising Panel

Set /

Rate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes.

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI

TENDER DOCUMENTS SUPPLY OF ELECTRICAL EQUIPMENT FOR BHADRAK MUNICIPALITY FOR THE YEAR LAST DATE OF RECEIVED OF TENDER DOCUMENTS :

MAIN INCOMER -1 (500 KVA TRF.)

ENGINEERING PROJECTS INDIA LIMITED HAL PROJECT, NASIK BOQ FOR ELECTRICAL WORKS IN PACKAGE II

PONDICHERRY UNIVERSITY ELECTRICAL WING Schedule

BILL OF QUANTITIES - ABSTRACT

Hkkjrh; izca/k lalfkku dksf"kddksm

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

TENDER SPECIFICATION. Rayalaseema Thermal Power Project (Muddanur) V.V.Reddy Nagar, Kalamalla Post,Cuddapah Dt, AP

NOTICE INVITING QUOTATIONS

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR


MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

SCHEDULE OF QUANTITIES ITEM DESCRIPTION

Price List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

GRAMIN BANK OF ARYAVART

: Material Description Quantity UOM

I N D I A N S T A T I S T I C A L I N S T I T U T E

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

SPECIFICATIONS FOR TRAILER MOUNTED SELF-CONTAINED COMPACTOR COMPAK

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

SNO DESCRIPTION QTY UNIT RATE AMOUNT MAIN PUMP 1

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city

(C)- ABSTRACT OF COST AR&M-

Zucchini Low-Medium Power

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

S P E C I F I C A T I O N

Miniature Circuit Breaker

LOT Kwp Solar PV Power Solution with Battery Backup

Earthing UNIT. Learning Objectives. Introduction. To understand purpose of Earthing. To learn system of earthing.

Polycab, Havell's pair Mtr

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

SOR-I: FOR SUPPLY PORTION

Item Code Description Unit Qty Total

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

XL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A

S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836

LB - LIGHTING BUSWAY 25-40A

Transcription:

FINANCIAL BID S. No. 1 2 3 4 5 6 7 8 9 10 11 12 NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH DESCRIPTION QTY UNITS RATE AMOUNT SETC of a KSEB Metering board fabricated out of 16 SWG CRCA sheet steel with lockable front door, CT and meter cabinets and glass window for meter mount consisting of a 125A 4P SFU, of 80A HRC fuse links, 80A neutral link all fully wired with 10 Sq. mm. multistrand cu. Wire. Supply and installation of Class 1 + 2 surge protection devise of OBO BETTERMAN MakeV25- B+C/3+NPE with manufacturers own enclosure as per its schematic layout between KSEB incoming and dedicated earth pit. SETC of 3 phase 4 way vertical MCCB DB double door consisting of 80A 4P MCCB as incomer, 2 Nos. 40A 3 pole MCBs as outgoing for lighting DB & 1 No. as spare, and 1 No. 63A TPMCB for power DB SETC of 3 phase 4 way vertical MCB DB double door consisting of 63A 4P MCB + ELCB 100mA as incomer and 6 Nos. of 6/16 A SP MCBs & 6 Nos. of 25 A SP MCBs as outgoing for PDB (DBs in banking hall should be concealed) SETC of 3 phase 4 way vertical MCB DB double door concealed on wall consisting of 40A 4P MCB + ELCB 30mA as incomer and 12 Nos. of 6A SP MCBs as outgoing as lighting DB. SETC of 3 phase 4 way vertical MCB DB double door consisting of 80A 4P Isolator + ELCB 100mA as incomer and 6Nos. of 6/16A SP MCBs & 6 Nos. 25A SP MCBs as outgoing for AC DB (DBs in banking hall should be concealed) SETC of 32A 4P Isolator in a suitable Metallic enclosure for controlling UPS power input in UPS Room SETC of 40A DP MCB in a suitable Metallic enclosure for controlling UPS power output in UPS Room SETC of UPS splitter DB single phase 8 way with 63A DP isolator as incomer and 2 Nos. 40A DP MCBs as outgoing to 2 Nos. UPS DBs. SETC of single phase MCB DB double door 12 way concealed on wall consisting of 1 No. 40A DP isolator as incomer 1 6/16A SP MCBs as outgoing as UPS DB Supply and installation of 25A 2Pole ELCB 100mA in manufacturers own enclosure in a rain proof area for Board light circuit & for AC units Supply and installation of 20/25A motor starter (accessible height) with 20A socket (Modular type) and 20A 3 pin top(near to AC indoor unit) for single phase air conditioners in BM s cabin, discussion room and in hall 5 Nos.

13 14 15 16 17 18 19 20 21 22 Supply and installation of 32A 4P ELCB of 100mA in manufacturers own enclosure for the protection of 3 phase air conditioners. Supply and installation of 25/32A 4P isolator in a weather proof enclosure near the location of condensing units of 3 phase air conditioners for isolating the AC units for periodical servicing. A. SETC of 100A 16KA TP MCCB in the existing MSB Panel for VDB. B. SETC of 63/80A 16KA TP MCCB in the existing MSB Panel for PDB / AC DB. Supply of all materials and wiring through wall / floor / recessed / surface for computer power point equipped with 5A 3 pin plug socket in one modular box and controlled by one 15A switch with indicator (modular type) enclosed in manufacturers own separate enclosure with matching face plate. In single window counters and work station cabins. Rate including supply and laying of 3R x 2.5 Sq.mm. copper wire as circuit from UPS DB to point (maximum point in one circuit shall be 2 stations), all SW counters and cash officer cabins to be arranged with only one unit. Supply of all materials and wiring through wall / floor / recessed/ surface for computer power point equipped with 5A 3 pin plug socket controlled by one 15A switch in the same modular box with matching face plate in locations other than wood work. Rate including supply and laying of 3R x 2.5 Sq.mm. Copper wire as circuit from UPS DB/PDB to points in Server room & BMs cabin (max. point in one circuit shall be 2 stations) Supply of all materials and wiring through wall / floor / recessed / surface for computer power point equipped with 5A 3 pin plug socket in one modular box and controlled by one 15A switch with indicator (modular type) enclosed in manufacturers own separate enclosure with matching face plate. In single window counters and work station cabins. Rate including supply and laying of 3R x 2.5 Sq.mm. copper wire as circuit from PDB to point (maximum point in one circuit shall be 2 stations), all SW counters and cash officer cabins to be arranged with only one unit. Supply and wiring of 5/15A power plug with indicator (modular type). Switched socket enclosed in manufactures own enclosure with matching faceplate. Rate including supply and laying of 3R x 2.5 sq. mm. FRLS Cu. Wire as circuit from power DB/ UPS DB to kitchen point in pantry, 1 points in server room, 1 in BM s Cabin and 1 No. to the front of locker room Supply and laying of 5R x 4 sq.mm. FRLS stranded copper wire through 25 mm ISI marked PVC conduit with all accessories, from AC DB to 3 Phase AC units Supply and laying of 3R x 6 sq.mm. FRLS stranded copper wire through 25mm ISI marked PVC conduit with all accessories from UPS output to UPS DB Supply and laying of 3R x 4 sq.mm. FRLS stranded copper wire through 20mm ISI marked PVC conduit with all accessories from PDB to Board lighting/ups input 1 1 60 Mtrs. 40 Mtrs.

23 24 25 26 27 28 29 30 31 32 33 34 35 36 Supply and laying of 3R x 2.5 sq.mm. FRLS stranded copper wire through 20mm ISI marked PVC conduit with all accessories from AC DB to single phase air conditioners Supply and laying of 3 Core 1.5 sq. mm. Copper cable of up to 2 mtr. Length with 6/16A plug top for records/ stationery/strong rooms Supply and wiring with 2 x 6 Sq.mm. copper wire through ISI mark PVC conduit from the earth bench of UPS to the dedicated earth of UPS system and also from the Surge Protection Device to its dedicated earth pit. Supply, laying and dressing of 3 Core 2.5 Sq. mm. Copper conductor PVC sheathed 1.1 KV grade armoured control cables on wall, ceiling, trench etc. with necessary MS clamps from DG Set to COS. Circuit wiring from LDB for 4/5 Nos. LED security lights connected in parallel, the rate shall be including of supply and laying of 3R x 2.5 sq.mm. FRLS stranded copper Wire through 20mm ISI marked PVC conduit with all accessories required, up to a length of 40 mtrs. Point wiring for 6/8 Nos. 15W LED down lighters in parallel connected the UPS supply in single control with a differently coloured plate type switch and face plate located in BMs cabin. SETC of 16A raw Power plug with indicator (modular type) Switched socket enclosed in manufactures own enclosure with matching faceplate. Rate including supply and laying of 3R x 2.5 sq. mm. cu. FRLS wire up to a length of 40 mtrs. as circuit from power DB to DG Set location for charger unit Supply and installation of modular type 16A one way Switch in suitable enclosure with matching face plate and frame, for DG set operation from inside of Branch. Supply and fixing of switch operated calling bell in manager s Cabin Supply & installation of of LED indication lamps (R,Y,B) in a suitable enclosure of modular type for the indication of KSEB incoming supply at convenient position by controlling with of 6A modular type one way switch in a suitable enclosure for controlling the indication lamps, rate shall be including of supply and laying of 4 x 1.5 sq. mm. PVC insulated copper wire through 20mm dia rigid PVC conduit up to a length of 30 mtrs. Supply and fixing of 20 pair Krone box with necessary connections to individual intercom lines and located in the system room Supply and laying of one run of 2 pair telephone wire from the location of EPABX to telephone point locations through 20mm PVC pipe with RJ 11 jack modular 2 plate with suitable box. Supply and laying of one run of 5 pair telephone wire through 20mm PVC pipe with all accessories required for installation Supply and installation of Ahuja make 50W Amplifier with USB port. Model: Ahuja DPA 570. 160 Mtrs. 0 Mtrs. 0 Mtrs. 2 Nos. 0 LS 1 30 Mtrs.

37 38 39 40 41 42 43 44 45 46 Supply and fixing of ceiling mounting speakers of 9W, CS 663 T Ahuja make including supply and laying of 2C x 1.5 sq. mm. PVC insulated stranded copper wire through PVC Pipe Supply and laying of 25 mm ISI marked PVC conduit with one run of 16 SWG GI wire from the location of hub to computer nodes Supply & fixing of 230 mm light duty exhaust fans in the toilet rooms Supply and fixing of 305 mm heavy duty exhaust fan including frame grouting/fixing, connected civil work etc. in battery room Supply and fixing of wall fan (Crompton Greaves) in Banking Hall Supply & Fixing of 48 white colour Crompton Greaves High Breeze ceiling fans from the ceiling with Anchor fastener hooks and adequate length of fan rods. SITC of all materials and wiring through wall, floor, ceiling concealed using color coded 1.5 sq. mm. PVC insulated FRLS stranded copper wire for point and same size wire with green color as continuous earth for points with independent earth wire for each circuit through ISI grade 25mm PVC conduit including all accessories as per IS code including circuit wiring using 2.5 sq. mm. size wire of same material and quality as above and factory made MS boxes, 2 plate modular switches and three plate ceiling rose/ connectors etc., of approved make for controlling one light/fan/exhaust fan/calling bell etc., number of wires to be used in the conduit should be limited to the IS standards. Check nuts, rubber/pvc bushing should be provided at the edges of MS conduit/switch boxes to avoid damage to insulation of the wires. Rate includes circuit wiring, cost of chipping floor/wall using machine and replastering to original form. All switch/socket/switch boards shall be of modular type. A. One light pt. controlled by one switch B. Two light point controlled by one switch (In Banking / Conference Hall) C. 5A socket with switch (combined) D. 5A socket with switch (independent position) for each SW counter E. Fan points controlled by Step type Electronic regulator F. 5A Socket near to device and switch separately at accessible height Chipping the wall for laying the PVC pipes, replastering and bringing back it original finish for concealing the existing vertical drops/switch boards. Charges for stickering of all DBs and boards with nice stickers for identification switch Supply and fixing of 18 / 20 W, 4 Ft. LED tube set with all accessories required for installation. (Philips, Wipro, Crompton) 6 Nos. 50 Mtrs. 2 Nos. 9 Nos. 2 1 5 Nos. 5 Nos. 1 50 Mtrs.

47 SETC of LED spot lights of approved make 6 Nos. 48 49 50 51 52 53 54 SETC of 2 Ft.x2 Ft. recess mounting Pure LED luminaire with Suitable supporting frame of approved one with fully wired on the fall ceiling with the chain /GI wire fasteners complete also with all accessories required for installation Supply & Fixing of 12/15W LED down lighters on to the false ceiling. Supply and fixing of bulb holder with 7W, 230V LED lamps (Philips, Wipro, Crompton) Supply & Fixing of LED bulk head fittings as security lights from approved make. (Philips, Wipro, GE) SETC of LED strip lights (Blue color LED lights) with IP 20 protection, rate shall be including of driver cost (Philips, Wipro, GE) SETC of LED strip lights (White or Worm color LED lights) with IP 20 protection, rate shall be including of driver cost (Philips, Wipro, GE) Supply, laying, dressing, connecting and commissioning of the following lengths of aluminium conductor PVC sheathed 1.1KV grade armoured power cables on wall, ceiling, trench etc. with necessary MS clamps including charges for making trench (if any) by supplying necessary fixing materials, proper cable glands, Sockets etc., including cable termination 18 Nos. 26 Nos. 50 Mtrs. A. 3.5C x 70 Sq.mm. 0 Mtrs. B. 3.5C x 50 Sq.mm. 55 56 C. 3.5C x 35 Sq.mm. D. 4C x 25 Sq.mm. E. 4C x 16 Sq.mm. F. 4C x 10 Sq.mm. Supply and installation of 25x3 mm. tinned Copper strip of 30 cm. length as earth bench Supply, laying & giving termination using bare cu. Wire for effective earthing of equipments. 20 Mtrs. 20 Mtrs. 20 Mtrs. 1 Mtrs. A. No.10 SWG Cu 120 Mtrs. B. No.4 SWG Cu C. No.6 SWG Cu D. 25 x 3 mm. Cu. Strip 2 Mtrs.

57 Supply & providing the following 58 59 60 61 62 63 64 65 A. Rubber floor mats B. Shock treatment chart C. Rubber gloves D. Caution Board Supply and laying of 40/60 mm heavy gauge water pvc pipe for the protection of cables / Service wire. Supply and installation of Legrand make 24 hr. timer in manufacturer s own enclosure for operational control of Exhaust fan SITC of earth electrode 40mm dia 3 Mtr. Long GI pipe electrode as per IS 3043-1987 for DG set earth points including neutral, Brass nuts, bolts and washers to be used. The rate shall include excavation back filling with salt and charcoal mix, ramming and consolidation, brick work, cover slab etc. A. Same as above but using 60cm x 60cm copper plate for UPS earthing. B. Same as above but using 60cm x 60cm GI plate for Surge earthing. Expenses for preparation of necessary drawings for scheme approval, correction of defects as mentioned by Electrical Inspectorate, submission of defect rectification report, arranging for inspection of Electrical Inspectorate officials and getting approval for energization of 125 KVA DG set (all statutory payments towards KSEB / EI which could be receipted for will be paid by the bank) Expenses for computing the total connected load of the Branch, A. For preparing the new fitted electrical layout and submission of work completion report to the Branch for processing of Additional Power allocation from KSEB B. For obtaining sanction and energizing of the installation including all incidental charges for obtaining sanction from KSEB (all statutory payments towards KSEB which could be receipted for will be paid by the bank) Charges for preparation of single line diagram on a sheet of A3 size using AutoCAD, laminating the sheet and displaying it in the UPS room for, A. Electrical layout of the whole Electrical installation B. Physical layout of all Electrical installations including Earth pits. Charges for Dismantling, Servicing, shifting and Refixing of ceiling or wall fans/ Tube Lights/Recessed mounted light fittings with supply of all the accessories required for installation (If any). 20 Sq. ft. 4 Mtrs. 2 Nos. 5 LS

66 67 68 69 70 71 Charges for dismantling the existing panel boards, switch boards, M.S. and conduit wiring, lights, fans etc. and clearing the premises of all old electrical fixtures and depositing as directed by the Manager of the branch (641/028/651) with GU10 Non- dimmable of up to 5/10W LED lamp (White/Warm Color) in Philips or its equivalent in Wipro & GE (641/028/651) with MR16 Non- dimmable of up to 5/10W LED lamp (Warm Color) in Philips or its equivalent in Wipro & GE (024/026/027) with GU10 Non- dimmable of up to 5/10W LED lamp (Warm Color) in Philips or its equivalent in Wipro & GE (024/026/027) with MR16 Non- dimmable of up to 5/10W LED lamp (Warm Color) in Philips or its equivalent in Wipro & GE Supply & Fixing of 10W LED Square down lighters on to the false ceiling. (Philips DN 097B or its equivalent in Wipro & GE) TOTAL AMOUNT GST @ 18% GRAND TOTAL AMOUNT GRAND TOTAL AMOUNT IN WORDS: FOR STATE BANK OF INDIA Signature and Stamp of the Contractor