The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Similar documents
27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Elmdene International Ltd

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

PSUPS10A12C. PSUPS 13,8V/12V/10A/17Ah. Buffer power supply for 8 HD cameras and recorder. v.1.0. Supercedes the edition: 1 from

PSU EN54-4 Power Supplies

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PSDCB161220E. v.1.0. PSDCB 13,8V/20A/16x1A/65Ah. Buffer power supply for up to 16 HD cameras. EN** Edition: 3 from

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

HPP1 MK5 Owner s Manual

K25000 & KD25000 Series

Lithium Power Supply

Uninterruptible Power System

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

AWZ 110. AWZ 13,8V/1A/7Ah/LM

HPP1 MK5 Owner s Manual

PURE SINE WAVE DC TO AC POWER INVERTER

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

EMIU 720W Mini Inverter

c-go 24V/6A 24V/8A 24V/12A

Phoenix Inverter

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

BNC08128C. BNC 13,8V/8x1A/17Ah. Switch mode buffer power supply unit for CCTV. v.1.0 EN** Edition: 1 from Supersedes the edition:

AWZ 200. AWZ 13,8V/2A/7Ah/L

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

USER S MANUAL SOLAR POWER INVERTER KW-6KW

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

New Batteries Directive Version 4 December 2009

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Eclipse Plus VA UPS and Surge Suppressor User s Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

EASY CHARGE Weather-resistant fixed mount Battery Charger

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Compact Sine Inverter

BS20 BATTERY CHARGER For lead-acid batteries

12VDC TO 230VAC INVERTERS

PSU1 Power Supply Unit

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Installation and Operation Manual Back-UPS BR800/1100CI-IN

HPP1 MK6-15A/20A R00 Owners Manual

Installation Instructions


7 Stage Automatic Smart Battery Charger (FOR CHARGING 12V / 24V AGM, GEL,SLA AND WET BATTERIES) USER MANUAL

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Uninterruptible Power System

Battery Power Inverters

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Installation and Operation Manual Back-UPS BR1000-CH

24V 3A EN54 Ancillary Power Supply

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

POWER-HUB 12 VOLT PORTABLE POWER STATION

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Liebert PowerSure PSI UPS

POE1824B. PoE 27,6V/4x0,4A/2x7Ah/PoE

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Uninterruptible Power System

Pure Sine Wave Inverter Charger

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

Language specific user manuals are available on

Installing Power Components

EC400 Power Control System

IMPORTANT SAFEGUARDS

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

Caution Wear protective glasses and turn your face away when connecting or disconnecting from the battery.

12 amp RMS Battery Charger

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

POWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service

BC12M248 7 Stage Automatic Smart Battery Charger, Desulfator & Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Pan and Tilt Head CDD2416-T

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Language specific user manuals are available on

OPERATION & MAINTENANCE INSTRUCTIONS

Mass Sine 24/10000 Mass Sine 24/15000

1000-Watt Energy Center

Liebert PSA VA. Installer/User Guide

EC225 Power Control System

CX-SERIES ADVANCED BATTERY CHARGER

U n i n t e r r u p t i b l e P o w e r S y s t e m

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

User Manual. Solar Charge Controller 3KW

POWERSOURCEPURE INSTRUCTIONS. Pure Sine Wave Inverter. RINV1200P REINV1200P RINV2200P REINV2200P

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Transcription:

1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL FOR CCTV CAMERA SYSTEMS Models: 4HR-UPS-8CAM 4HR-UPS-16CAM 4HR-UPS-32CAM FEATURES The Elmdene s 4HR-UPS range is available in 3 models, each designed to provide 220V ac with standby battery capability for CCTV systems consisting of up to 32 cameras. Designed with the security industry in mind, the range provides extended backup times of typically 4 hours to a complete PoE CCTV system, whilst utilising readily available, cost effective, industry standard 12V SLA batteries. In the event of a mains failure, the 12V batteries seamlessly continue to provide standby power to the system until the mains power is restored or the batteries reach their deep discharge protection limit. Mains fail volt-free contacts are also available to signal a mains failure, if required. The range is offered in 3 models, based on the typical size of the CCTV system: 4HR-UPS-8CAM Ideal for up to 8 cameras (100W(VA) max*) 4HR-UPS-16CAM Ideal for 9 to 16 cameras (200W(VA) max*) 4HR-UPS-32CAM Ideal for 17 to 32 cameras (220W(VA) max*) All models consist of a 19 rack (4U height) head unit, and an additional floor standing battery cabinet provided for the 16 & 32 camera variants. Mains powered, they provide a 220V ac output to power the connected device(s) such as a PoE NVR or a Power over Coax CCTV system & monitor. The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries. Continuous full rated power to load Battery Deep Discharge Protection Mains input voltage 200 240V ac Volt-free contact signalling mains failure Volt-free contact signalling lid tamper and PSU faults 4U 19 rack enclosure Rear battery access (2 x 12V 18Ah batteries) Reverse battery protection Blue LED indicates Inverter health Red LED indicates running in standby (battery) mode Provides extended standby times Supplied with 2m IEC input power cord (UK plug) C13 IEC socket outlet Floor standing battery cabinet (16& 32 Camera variants) *Maximum load stated is based on a unity power factor (1). To determine power factor contact the equipment manufacturer OR test system load to determine the actual VA using a power meter, alternatively you must de-rate the UPS Max load by 50%

2 SPECIFICATION Input Specification Voltage (rated) Max Current 220V ac Output Specification Voltage 220V ac +/-5% Frequency 50 60Hz Wave form Pure Sine Wave 220-240V ac 50 60Hz 8CAM - 4A (T4A HRC fused) /16/32CAM - 5A (T5A HRC Fused) Max load Power 4HR-UPS-8CAM - 100W(VA) * 4HR-UPS-16CAM - 200W(VA) * 4HR-UPS-32CAM - 220W(VA) * *Maximum load stated is based on a unity power factor (1). To determine power factor contact the equipment manufacturer OR test system load to determine the actual VA using a power meter, alternatively you must derate the UPS Max load by 50% Standby Battery Battery Type Battery Capacity Battery Cut-off (Deep discharge protection) 2 x 12V Valve Regulated Sealed Lead Acid See table below 21V Standby time examples (utilising 2 x batteries): Model reference Continuous Load Batteries Approximate Standby time** (hours) Recharge Time (hours) 4HR-UPS-8CAM (100W max*) 4HR-UPS-16CAM (200W max*) 4HR-UPS-32CAM (220W max*) 40W 7.5 70W 2 x 12V 18Ah 4 100W 2.5 145W 4 175W 2 x 12V 38Ah 3 200W 2.5 110W 10 175W 2 x 12V 65Ah 6 220W 4 <24 <48 <100 *Maximum load stated is based on a unity power factor (1). To determine power factor contact the equipment manufacturer OR test system load to determine the actual VA using a power meter, alternatively you must de-rate the UPS Max load by 50% **Standby times are approximate and can vary dependant on battery age and condition and are calculated based on Yuasa s technical data.

3 Extended Standby time examples (utilising 4 x batteries***): Model reference Continuous Load Batteries (12V SLA) Approximate standby time** (hours) Recharge Time (hours) 4HR-UPS-16CAM (200W max*) 175W 2 x 12V 18Ah + 4 200W 2 x 12V 38Ah 3 <72 4HR-UPS-32CAM (220W max*) 220W 2 x 12V 18Ah + 2 x 12V 65Ah 5 <100 *Maximum load stated is based on a unity power factor (1). To determine power factor contact the equipment manufacturer OR test system load to determine the actual VA using a power meter, alternatively you must de-rate the UPS Max load by 50% **Standby times are approximate and can vary dependant on battery age and condition and are calculated based on Yuasa s technical data. ***Ensure the specially designed battery link cable is used in accordance with connection diagram when connecting 4 batteries together. It is important that all the batteries are of a similar age, condition and preferably from the same manufacturer to preserve their life expectancy. When changing batteries ensure they are changed as a pair. Standby Time rating Curves

4 Example CCTV system power requirements: System Components Approximate Load* 4 Camera + NVR/HDD 44W 8 Camera + NVR/HDD 68W 16 Camera + NVR/HDD 116W 32 Camera + NVR/HDD 212W *Check equipment manufacturer details for actual power requirements. Figures above based on 6W PoE cameras and 20W NVR with HDD installed. We recommend where specific standby times are required that you over specify the UPS battery choice to take into account natural battery degradation. Maximum load stated is based on a unity power factor (1). To determine power factor contact the equipment manufacturer OR test system load to determine the actual VA using a power meter, alternatively you must de-rate the UPS Max load by 50%

5 Mechanical Model Enclosure Dimensions (mm) Weight (kg) [Excluding batteries] 4HR-UPS-x (4U 19 Rack) 400L x 483W x 172H 14 KG* Floor standing battery cabinet (Supplied with 16 and 32 camera models) 450W x 535H x 245D 13 KG *Due to the weight of the 4U 19 UPS enclosure and 2 x 12V 18Ah batteries ensure suitable rack fixings and rails are used when securing in 19 rack Environmental Temperature -10 to +40 C (operating) 75% RH non-condensing -20 to +80 C (storage) FAULT SIGNALLING OUTPUTS General Fault Mains Fault 0.1 A @ 60V dc N/O volt-free contact. Open if Mains failed and battery voltage < 23 V, lid tamper activated or fault PSU fault condition, (see below) 0.1A @ 60V dc N/O volt-free contact. Open when loss of mains for more than 8s. SIGNALLING AND DIAGNOSTICS MAINS Fault GEN Fault Condition Possible Cause Action CLOSED CLOSED Normal operation Mains present Battery healthy OPEN CLOSED Standby Mains lost Mode Battery driving load CLOSED OPEN Fault Present Blown fuses Battery fault Internal fault Lid tamper activated OPEN OPEN PSU Mains lost Shutdown Standby battery exhausted CONNECTIONS None (No fault) Investigate loss of mains Investigate fault source using diagnostic LED Rectify fault where possible Restore mains as soon as possible MAINS INPUT UPS OUTPUT MAINS FAULT GEN FAULT IEC C14 Socket 2m UK mains Lead supplied ON/OFFF switch with 10A Fuse Protection IEC C13 Outlet No extension lead supplied Mains Input Lost UPS or Tamper Fault

6 INSTALLATION INSTRUCTIONS This unit is only suitable for installation as permanently connected equipment. The 4HR-UPS is suitable only for indoor installation. This unit must be fed from a mains power source having a separate (approved) disconnect device suitable for the installation site and fitted with a fuse or other over-current protection device rated at 5A maximum. Ensure that the disconnect device used has appropriate earth fault protection to the applicable standard. EQUIPMENT MUST BE EARTHED. Before installation, ensure that on/off switch is OFF. The PSU should be installed according to all relevant safety regulations applicable to the application. 4HR-UPS 19 Rack Mounting 1) Mount securely in correct orientation ensuring suitable rack, fixings and supports are used to suit the weight of the product with batteries installed 2) Ensure appropriate access is possible for future battery maintenance 3) Use IP66 bushes and cable glands rated to UL94 HB minimum. Mains Power Up 4) Attach supplied power cord or correctly rated mains cord (minimum 0.5mm 2 [3A], 300/500Vac). Connect other end to 230Vac socket and Turn mains switch on the switch should illuminate. 5) Check PSU Green Mains LED is ON. Check Inverter Blue LED is ON (check switch is in ON position). Load Output 6) Connect correctly rated v or extension lead to UPS output and connect CCTV devices. 7) Check PSU Module Green Mains LED is ON. Check Inverter Blue LED is on. Check connected device power LED is ON. 8) NOTE: Yellow Fault LED on internal PSU module may flash to indicate no battery has been connected. This is normal. 9) Verify PD is operating correctly. 10) Turn power switch to off position and disconnect load output power strip PSU Module Signalling Outputs 11) Connect EPS and GEN fault outputs to appropriate inputs of control equipment (if used). Standby Battery 2x 18Ah Battery Compartment 12) Remove battery compartment cover, if not already done so 13) Attach supplied battery cables to batteries. NOTE: ensure correct polarity! Red lead to +ve of battery 1, Black lead to -ve of battery 2. Connect -ve of battery 1 to +ve of battery 2 using short link lead provided 14) Turn mains switch to on. Check Green Mains LED is ON and Blue Inverter LED is ON 15) Note an internal amber PSU LED will flash, signalling battery charging for at least 24 hours from when the mains is applied this is normal. 16) Turn the mains switch to off. Check PSU Module Green Mains LED is OFF. Check Blue Inverter LED is on and Red Standby operation LED is on. NOTE: Batteries must have sufficient charge to supply the load 17) Turn mains switch to On and reconnect output power strip and connected devices still have power. 18) Check Green Mains LED is ON. Check Blue Inverter LED is on. Check connected devices power LED is ON. 19) Turn the mains switch to off. Check PSU Module Green Mains LED is OFF. Check Blue Inverter LED is on and Red Standby operation LED is on and connected load remains powered. 20) Turn Mains switch to ON. Commission complete.

7 FLOOR STANDING BATTERY CABINET ASSEMBLY AND USE 1) Remove the battery box from the packaging. 2) Remove the shelves. 3) With the door open, remove the lid. Lid removed Both shelves removed

8 4) If not fitted, install the wall mounting bracket to the rear panel, using 4 off M5 pan head screws and plain washers M5 screws and washers Wall bracket 4 screw positions. 5) Position the case in its installation position. 6) Spot through 4 fixing screw positions. 7) Withdraw the unit, and fit required plugs as appropriate. 8) Reposition the unit, and secure with appropriate fixing screws.

9 BATTERIES AND CABLE INSTALLATION 9) Remove knock outs on either the side or rear of the case. Earth cable: 10) Connect the earth (green and yellow) lead in the 3 metre cable to the top right hand (interior) fastener as shown. 11) Use a M5 washer and M5 plain nut 12) Ensure the abutting face on the rivet nut is free from paint. Earth cable M5 plain nut and washer 13) Replace both shelves in the case.

10 14) Install the batteries in the orientation shown, with the terminals to the front, and the positive terminal to the left hand side. +ve terminal 15) Fit positive and negative ends of 3m cable to the batteries as shown (crimped ring terminals): +ve Link -ve cable

11 16) Route the positive (red lead) of the 3m cable to the positive terminal of the upper battery 17) Route the negative (black) lead of the 3m cable to the negative terminal of the lower battery 18) Connect the black 600 mm link cable to the negative terminal of the upper battery 19) Connect the other end of the black link wire to the positive terminal on the lower battery. 20) For connection to the power supply, refer to the relevant installation instruction 21) Replace the lid and secure the door shut with the 2 off M4 screws and washers. OPERATING INSTRUCTIONS This unit is intended for use by Service Personnel only - There are NO USER SERVICEABLE parts inside. The Front LED window will illuminate and to show the status of the outputs. In the event of a PSU fault condition, an internal Yellow Fault LED will be illuminated and the fault outputs will open. An internal Amber Battery Charging LED will be illuminated when the batteries is not fully charged and is charging normally. When the battery is fully charged, this LED will be extinguished. MAINTENANCE There is no regular maintenance required of the unit other than periodic testing and replacement of the standby batteries. Reference should be made to the battery manufacturer s documentation to determine typical/expected battery life with a view to periodic replacement of the battery. If the output of the unit fails the cause of the failure should be investigated e.g. short circuit load. The fault should be rectified before restoring power to the unit. If fuses need to be replaced ensure the correct fuse rating and type is used. PRODUCT IMAGES Front panel LED indication label

12 WARNING: ALWAYS FIT 2 BATTERIES and wire in series, the product will NOT work with a single 12 V battery

13 2X BATTERY WIRING DIAGRAM FOR 16/32CAM WARNING: ALWAYS FIT 2 BATTERIES (2x 12V 38Ah or 2x 12V 65Ah) and wire in series, the product will NOT work with a single 12 V battery

14 WARNING: ALWAYS FIT BATTERIES IN PAIRS (2x 12V 38Ah or 2x 12V 65Ah + 2x 12V 18Ah) and wire in accordance with this diagram, the product will NOT work with less than 4 batteries

15 INTERNAL PSU MODULE LOCAL INDICATORS MAINS LED (GREEN) FAULT LED (YELLOW) CHARGE LED (ORANGE) STATUS ON OFF OFF NORMAL - battery fully charged ON OFF ON NORMAL - battery charging ON 1s ON, 1s OFF ON or OFF FAULT - see Signalling Outputs OFF 0.1s ON, 3s OFF OFF FAULT - Mains Loss PSU operating on battery standby OFF OFF OFF FAULT - No Output Mains and Battery loss

16 Fault Diagnostic table Internal diagnostic LED Service Engineer use only Green Orange LED LED Condition Possible Cause Action Diagnostic Mains Normal Mains present ON None operation Battery fully charged OFF FLASH CONTINUOUS OFF ON or OFF 1 PULSE ON 2 PULSES ON OFF Standby Operation No output Battery Charging No Battery Low Battery Volts 3 PULSES ON or OFF Battery Fault 4 PULSES ON or OFF Charger Fault 5 PULSES ON or OFF ON CONTINUOUS ON or OFF INVERTER LOCAL INDICATORS POWER LED (GREEN) Battery Temperature Probe Fault Internal Fault FAULT LED (RED) Mains Lost. No faults present Battery driving load Output fuse blown Output overload Output short circuit No faults active Battery charging normally but < 90% of full charge Battery disconnected Battery fuse blown Battery heavily discharged Standby Mode Battery almost discharged High impedance in battery connection Battery internal fault Internal failure of battery charger Battery temperature monitor disconnected or damaged PSU running in Safe Mode Software fault detected PSU running in Safe Mode STATUS Investigate loss of mains Check and replace output fuse Disconnect output load and test load None Check battery connections Check battery fuse Check battery condition Replace battery if aged Restore mains Check battery connections for corrosion. Replace battery if aged Return to manufacturer Check temperature sensor connections and condition of sensor. Replace if suspect Return to manufacturer ON OFF NORMAL ON ON FAULT Check: Environment temperature is not too high Check the load power is not too high Check for short circuits and remove OFF OFF FAULT - Mains Loss, Check Battery condition AUDIBLE ALARM ON FAULT CONDITION Low Battery Voltage Overload Condition High Internal Temperature Short Circuit WHAT TO CHECK Mains is on, battery condition UPS is suitable for System load Environmental temp is below 40 C Output Power strip for damage

17 COMPLIANCE This power supply unit meets the essential requirements of the following European Directives: Low Voltage: 2014/35/EU WEEE: 2012/19/EU EMC: 2014/30/EU RoHS2: 2011/65/EU DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Directives 2012/19/EU Waste Electrical and Electronic Equipment (WEEE) and 2013/56/EU (Battery). At the end of life, the product must be separated from the domestic waste stream and disposed via an appropriate approved WEEE disposal route in accordance with all national and local regulations. Before disposal of the product, any batteries must be removed, and disposed separately via an appropriate approved battery disposal route in accordance with all national and local regulations. Package used batteries safely for onward transport to your supplier, collection point or disposal facility. Caution: Risk of fire or explosion if bare battery wires are allowed to touch. See Specification for battery type information. The battery is marked with the crossed out wheelie bin symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For more information see: www.recyclethis.info 3

18 The packaging supplied with this product may be recycled. Please dispose of packaging accordingly.