SAFTRONICS DF8 PLUS SERIES

Similar documents
1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Boston Gear Ratiotrol DC Motor Speed Control

Snap-Trol 183 Nema 1 Series

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Filtered PWM Speed Control for Permanent Magnet DC Motors

Boston Gear Ratiotrol DC Motor Speed Control

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

Boston Gear Ratiotrol DC Motor Speed Control

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

CONTROL FEATURES AVAILABLE OPTIONS

MaxPak Plus Analog DC V S Drive

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

Boston Gear Ratiotrol

Installation & Operation Manual

Fincor Series 2230 MKII/2240

CABINET REEL OPERATING INSTRUCTIONS

Boston Gear Ratiotrol

CABINET REEL OPERATING INSTRUCTIONS

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC


TABLE OF CONTENTS STANDARD FEATURES

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

Boston Gear Ratiotrol

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

17429X.00 SERIES MODELS:

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

5001TCP SPEED CONTROLLER

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

IDP100 SERIES MOTOR CONTROL. Instruction Manual Models IDP IDP102-BC1 IDP102-BC2 IDP102-RC1 IDP102-RC2 IDP IDP105-BC2 IDP105-RC2

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

5001TCP SPEED CONTROLLER

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

DC3N Non-Regenerative DC Drives

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

Copyright 2013 Automationdirect.com Incorporated All Rights Reserved

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

PALLET MASTER (PMD) OPERATING INSTRUCTIONS

MELLTRONICS DRIVES. Single Phase Regenerative DC Drives ¼ HP TO 7½ HP INSTALLATION OPERATION MAINTENANCE

Clif Mock. CD20 (12VDC) Sampler Drive. User Manual. Manual No A

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

BC141, BC142, BC142-5 & BC142-6 DC Control

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

BLAZER D.C. MOTOR CONTROL

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

KBIC SCR DC Motor Speed Controls

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

KBMD-240D MULTI-DRIVE

Dayton DC Motor Control

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

CD-20A Sample Probe Controller User Manual

Boston Gear. Adjustable-Speed Regenerative DC Motor Controllers. Installation and Operation Manual. Doc. No RBA-RG VEA-RG Series

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

Excel [XL] Series USER S MANUAL

Model 616 Rotating Disk Electrode Instruction Manual

WarninG TraDeMarkS Copyright 2013, 2018 Automationdirect.com Incorporated All Rights Reserved

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

TABLE OF CONTENTS WARRANTY. 1 INTRODUCTION. 2 CONTROL FEATURES. 2 HEATSINK DIMENSIONS. 2 SPEEDPOT KIT ASSEMBLY. 3 MOUNTING PROCEDURE.

II DISTRIBUTION & SUBSTATION TYPE C

Boston Gear Ratiotrol

Installation and Operation Manual. *See page 6 for CE Information

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

Installation and Operating Manual

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

Owner s Manual. Features

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

Model A Switching Logic Board. User s Manual. For Use With Minarik Full-Wave Regenerative Drives

RG500 SERIES USER S MANUAL. SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors

XP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.

DC Drive Selection Guide

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

An American Control Electronics Brand. RG6xU SERIES USER MANUAL RG60U RG61U.

Transcription:

DF8 PLUS SERIES ¼ to 5 HP Full Wave Regenerative Reversing SCR Speed Controls for DC Motors CAUTION Equipment is at possibly lethal AC line voltage when AC power is connected. Pressing the STOP pushbutton does not remove AC line voltage. Both phases must be disconnected before it is safe to touch motor terminals or control equipment parts. Saftronics, Inc. 5580 Enterprise Pkwy., Ft. Myers, Fl 33905 Telephone: (941) 693-7200 Fax: (941) 693-2431 P/N X010034 REV:5

DF8 PLUS INSTRUCTION MANUAL CONTENTS Eff Date: 25Aug97 Section 1.0: Description 1.1 Overview... 1 1.2 Standard Features... 2 Section 2.0: Specifications 2.1 Electrical... 2 2.2 Electrical protection... 3 2.3 Mechanical... 3 2.4 Adjustments... 4 2.5 Jumper selections... 5 Section 3.0: Receiving & Installation 3.1 Installation... 6 3.2 Derating data... 6 3.3 Wiring... 6 Section 4.0: Startup 4.1 Inspection... 7 4.2 Pre-start adjustments... 7 4.3 Starting... 7 Section 5.0: Troubleshooting... 8 Section 6.0: Wiring diagrams 6.1 DF8P-10 & DF8P-15... 9 6.2 DF8P-25... 10 6.3 Typical torque control connection... 11 6.4 Motor connections... 12 Section 7.0: Dimensional outlines 7.1 DF8P-10 & DF8P-15 Chassis... 13 7.2 DF8P-25 Chassis... 14 7.3 NEMA 1 Enclosed with operators... 15 Section 8.0: Spare parts... 16 Section 9.0: Warranty... 17

1.0 DESCRIPTION 1.1 Overview DF8 "Plus" series fully regenerative four quadrant thyristor controllers are designed to control the speed of wound field or permanent magnet dc motors from ¼ to 5 hp. These drives can also be modified to become torque control regulators. DF8 "Plus" drives are supplied in either chassis or Nema 1 enclosed formats. Control block diagram Four quadrant operation Motor rotation Torque Note: Arrows same direction Motoring Arrows opposite Braking 1

1.2 Standard Features 2.0 SPECIFICATIONS 2.1 Electical Isolated current feedback AC current transformers sense current in each bridge. Impedance-isolated armature voltage feedback High impedance resistive voltage divider network used for armature voltage feedback. Tachogenerator feedback 50 volt/1000 rpm tachometers may only be used for speed feedback. Dual AC line voltage 120 or 240 vac line voltages are plug selectable. Dual field voltage 100/50 or 200/100 volt field supplies for 120 or 240 ac line voltages. Matched +12V and -12V reference supply Regenerative braking to zero speed with signal contact output LED indication Power on (DS8 red) Forward speed reference (DS5 green) Reverse speed reference (DS4 red) Forward amplifier output (DS7 green) Reverse amplifier output (DS6 red) Run relay energized (DS2 red) Inhibit (DS3 red) Zero speed (DS1 red) Power Single phase 120 or 240 vac, 50/60 Hz., (±10%). Speed range 30:1 with armature feedback, 50:1 with tachometer feedback. Load regulation ±3% with armature voltage, (±10% line voltage change). Acceleration/Deceleration Adjustable: 0.1-30 seconds from 0 to full speed. Temperature range 32 F - 104 F (0-40 C). Altitude 2000 feet (600m) maximum without derating. Regenerative braking Upon application of a stop signal the drive will regeneratively brake and stop at zero speed. This feature depends on the setting of jumper P1 (see page 5). 2

2.1 Electrical cont'd Rectifier configuration The DF8 "Plus" employs two single phase, full-wave, fully controlled, (4 SCR) bridges to allow extremely rapid motor armature reversing. HP & Current rating MODEL HP AMPS 120 VAC 240 VAC INPUT OUTPUT DF8P-10 1 2 18 10 DF8P-15 1.5 3 25 15 DF8P-25 2.5 5 37 25 Voltage rating OUTPUT VDC INPUT ARMATURE FIELD 120 VAC (J6) 90 0 90 100/50 240 VAC (J5) 180 0 180 200/100 2.2 Electrical Protection Short circuit rating Suitable for use on a circuit capable of delivering not more than 5000 rms symmetrical amperes, 240 V maximum. Fusing One fast-acting fuse in each AC leg. Current limit Adjustable current limit circuit for each bridge. Surge suppression MOV surge suppressor. 2.3 Mechanical For dimensional information see pages 13 & 14. 3

4 2.4 Adjustments CAUTION: Adjusting RV6 to over 50% clockwise rotation, may cause drive instability which cannot be corrected by RV7 voltage stability. In such a case, back off slightly from the position where RV6 causes instability. This may result in a slight decrease in speed holding. RV1 +12V reference This factory preset adjustment will very seldom need adjustment. It is used to match the +12 volt reference supply to the -12 volt supply. RV2 Current stability This control, which has been factory preset, adjusts the stability of the current loop. The normal position of this trimpot is approximately 1/2 turn clockwise. RV3 Acceleration/Deceleration This control adjusts both acceleration and deceleration time. In the fully clockwise position, acceleration/deceleration time is 0.1 seconds, and in the fully counterclockwise position, acceleration/ deceleration time is 30 seconds. RV4 Maximum speed This adjustment is used to set the maximum armature voltage or motor speed. RV5 Zero speed offset This adjustment is used to minimize creeping of the motor with the speed reference set to "zero". RV6 IR Compensation Factory set to CCW for Tach Feedback, this control rarely needs to be used. However, when using armature voltage feedback with cyclical loading applications where there is a speed drop due to operation from high to low load, the IR Comp adjustment corrects for voltage changes inside the DC motor when load is applied. If speed variations with load are a problem, set the SPEED control knob to the desired operating speed. Now load the drive. Adjust RV6 until the motor speed returns to its unloaded speed. Remove the load and ensure motor speed is stable. RV7 Voltage stability This is factory preset and very seldom needs adjustment. If the motor should hunt, rotate this trimpot until the motor runs smoothly. The normal position of this trimpot is approximately 1/2 turn clockwise. RV8 I Forward This adjustment is factroy preset for the maximum allowable DC current in the forward motoring direction. This trimpot will adjust the current limit setting from 20-150% of the drive rating. RV9 I Reverse This adjustment is factroy preset for the maximum allowable DC current in the reverse motoring direction. This trimpot will adjust the current limit setting from 20-150% of the drive rating.

2.5 Jumper Selections Note: If P1 is in the IN position, the drive will still regenerate when the speed reference command is reduced. J5 & J6 AC Input selection This jumper is used to select the correct AC line input voltage. J5: 240 vac (factory default) J6: 120 vac P1 Stopping mode IN Motor coasts to zero speed on stop command. Connect P1 on the AA1152 control card to the IN position. Motor regenerates to zero speed on stop command. ("OUT" position, factory default). OUT Caution: This drive can not be configured to accept tachometer feedback and an auxiliary speed command together. JP1 Programmable input This jumper is used to select either tachometer feedback 50v/1000 rpm) or auxiliary speed reference input. The auxiliary speed input will allow the user to trim (±) the main speed reference. The auxiliary input is not affected by the accel/decel circuit. Auxiliary speed input With JP1 in the "AUX SPD" position, the drive is configured to accept an auxiliary speed command. The speed input will AUX SPD then be accepted on input terminals J1-1 and J1-2. Tachometer feedback With JP1 in the "TACH" position, the drive is configured to accept a 50v/1000 rpm analog DC tachometer only. The tachometer input will be accepted on input terminals J1-1 and J1-2. Locate jumpers E1 and E2 above the control transformer T1. These jumpers will be connected to a black wire TACH terminal. Separate the plug from the socket for tachometer feedback. To set the drive back to armature feedback, insert the plug into the socket and remove the tach wires from terminals J1-1 and J1-2. 5

3.0 RECEIVING & INSTALLATION 3.1 Installation The cabinet containing the DF8 Plus must be installed in an area where the following conditions exist: Ambient temperature does not exceed 40ºC (104ºF). Ambient temperature is not less than 10ºC (50ºF). Altitude above sea level is 2000 feet (600m) or less. Ambient air is reasonably clean, dry and free of flammable or combustible vapors, steam, or corrosive gases, etc. The cabinet must be installed away from any heat source, and a minimum of 1 foot (30.48 cm) is required around the air inlet and outlet, on ventilated units. The DF8 Plus has been designed for 50ºC maximum inside the enclosure. 3.2 Derating Data When the unit is installed in poor environmental conditions, it must be derated as follows: 1.5% per Cº above 40ºC, or 0.75% per Fº above 104ºF. 15% per 1000 feet (300m) above 2000 feet (600m). 3.3 Wiring The DF8 Plus is to be connected according to the NEC and any other applicable Electrical Codes in the customer's area. The chassis must be bonded to earth ground. Section 6 pages 8, 9, and 10 show typical connections for speed controlled wound field motors. For permanent magnet motors, there will be no connections to F+ and F-. See page 11 for typical torque control connections. Note: For motor field connections of 100/50 or 200/100, refer to page 12. 6

4.0 STARTUP 4.1 Inspection Ensure that the drive has been installed according to the previous guidelines. Also, ensure that the unit has been wired according to the schematics. Check that all connections are tight and that the motor can rotate freely. 4.2 Pre-start adjustments Before power is applied, confirm that the voltage selection plug (J5, J6) on the AA1152 card matches the supply voltage. Factory default setting is 240 vac. Note: When tachometer feedback is used, the auxiliary input is not available. 4.3 Starting The DF8 Plus drive has been preset for armature voltage feedback. To use tachometer feedback refer to page 5, section 2.5, for complete details. Confirm that all jumper selections have been made correctly to ensure proper drive performance (i.e. P1, JP1, JP5, JP6, see page 5). All controls have been preset at the factory and should not require further adjustment. Before applying power, refer to section 6.0 and ensure that all control and power wiring is correct, the power source, motor, and drive are matched, and that all links are properly set. Turn the speed pot to the zero reference position and ensure that the run circuit is disabled. 1. Apply power and observe that LED DS8 is illuminated. Press the start button. LED's DS2 (Run) and DS3 (Inh) should turn on and the motor should not rotate. If the motor rotates, see troubleshooting. 2. Slowly rotate the speed pot so that a negative reference is applied to J1-5 (see section 6.0). LED DS5 (Fwd ref) and DS7 (Fwd out) will intensify as the speed pot is increased to full and the motor should rotate in the forward direction. If motor rotation is incorrect, remove power completely and interchange the motor armature connections. With link P1 in the bottom position, LED DS1 (ZSA) will illuminate when the motor is above zero speed. 3. With a positive reference applied to J1-5 (see section 6.0), LED's DS4 (Rev ref) and DS6 (Rev out) will intensify as the speed pot is increased to full and the motor should rotate in the reverse direction. 4. With the speed reference set at maximum, the motor should rotate at rated speed and/or voltage. If not, adjust RV4 for the correct setting. 5. Press the stop button. With link P1 in the IN position, the motor will coast to rest. If P1 is in the OUT position, the motor will regenerate to zero speed. 6. If the acceleration and deceleration rates are not suitable, see section 2.4, p.4, for adjustment. 7

5.0 TROUBLESHOOTING SYMPTOM Motor does not run AC line fuse/fuses blown Motor runs at slow speed with the speed pot set fully cw. Motor unstable. Motor overspeeds with low speed reference Motor drifts at zero speed PROBABLE CAUSE - No Run command. - Speed reference at 0 volts. - Blown fuses or no AC source. - SCR shorted. - Field diodes shorted (D18). - Grounded motor armature or field. - Max speed set too low. - Drive in current limit. - Tach feedback resistor incorrect (if used). - Bad speed pot. - IR comp turned too high - Voltage stability set incorrectly. - Current stability set incorrectly. - Max speed set too high. - Fwd/Rev current limits set differently. - Max speed set too high. - Tach input reversed (if used). - No tach feedback if in tach mode. -Adjust RV5 potentiometer. 8

6.0 WIRING DIAGRAMS 6.1 DF8P-10 & DF8P-15 9

6.0 WIRING DIAGRAMS CONT'D 6.2 DF8P-25 10

6.0 WIRING DIAGRAMS CONT'D 6.3 Typical Torque control connection 11

6.0 WIRING DIAGRAMS CONT'D 6.4 MOTOR CONNECTIONS 12

7.0 DIMENSIONAL OUTLINES 7.1 DF8P-10 & DF8P-15 CHASSIS DF8P-10 DF8P-15 13

7.0 DIMENSIONAL OUTLINES CONT'D 7.2 DF8P-25 CHASSIS 14

7.0 DIMENSIONAL OUTLINES CONT'D 7.3 NEMA 1 ENCLOSED WITH OPERATORS 15

8.0 SPARE PARTS SPARE PART MODEL DF8P-10 DF8P-15 DF8P-25 QTY Controller card AA1152-1 AA1152-1 AA1152-1B 1 SCR N610016 N610016 4 SCR N10SP03B 8 Fuse FU1, FU2 F601005-34 F601005-36 F601005-31 2 Field Bridge D1010-04 D1010-04 D1010-04 1 Fuse FU3, FU4 F602003-05 2 Note: When replacing the controller card AA1152-1, ensure that all jumpers are configured the same way as the card being replaced. 16

9.0 WARRANTY Saftronics warrants to buyer that products, and any services furnished hereunder will be free from defects in material, workmanship and title, and will be of the kind and quality specified in the quotation. The foregoing shall apply only to failures to meet said warranties (excluding any defects in title) which appear within one year from the date of shipment hereunder, provided, however, that if buyer, in the course of its regular and usual business, transfers title to or leases such products (including equipment incorporating such products) to a third party, such period shall run until one year from such transfer or lease or eighteen months from shipment by Saftronics whichever occurs first. The warranties and remedies set forth herein are conditioned upon (a) proper storage, installation, use and maintenance, and conformance with any applicable recommendations of Saftronics and, (b) buyer promptly notifying Saftronics of any defects and, if required, promptly making the product available for correction. If any products or services fails to meet the foregoing warranties (except title), Saftronics shall thereupon correct any such failure either, at its option, (i) by repairing any defective or damaged part or parts of the products, or (ii) by making available FOB Saftronics plant or other point of shipment, any necessary repaired or replacement parts. The preceding paragraph sets forth the exclusive remedies for claims (except as to title) based on defect in or failure of products or services, whether claim in contract or tort (including negligence) and however instituted. Upon expiration of the warranty period, all such liability shall terminate. The foregoing warranties are exclusive and in lieu of all other warranties, whether written, oral, implied or statutory. No implied statutory warranty of merchantability or fitness for particular purpose shall apply and Saftronics will not be liable for any consequential damage arising from any product defect or failure to deliver on time. Saftronics does not warrant any products or services of others which buyer has designated. 17

Saftronics, Inc. 5580 Enterprise Pkwy., Ft. Myers, Fl 33905 Telephone: (941) 693-7200 Fax: (941) 693-2431