DUAL DISPLACEMENT HYDRAULIC MOTOR

Similar documents
IAC. Dual displacement hydraulic motors

Intermot Hydraulic Motors. Drum Brakes RC Series

GENERAL INFORMATION HYDRAULIC MOTORS ITALY

IAC. Dual displacement hydraulic motors

IAC SERIES TECHNICAL CATALOGUE INDEX 8 DRAIN RECOMMENDATIONS 12 SHAFT SEAL FEATURES 13 FORMULAS CONVERSIONS 14

INTERMOT DUAL DISPLACEMENT MOTORS

INTERMOT DUAL DISPLACEMENT MOTORS

TECHNICAL CATALOGUE FD/FDM FDM

Single displacement hydraulic motors High Cavitaton

W SERIES TECHNICAL CATALOGUE

Intermot Hydraulic Motors. Brakes

Low Speed High Torque Motors

BENT AXIS PISTON MOTORS SERIES HPM FLANGE ISO HPM. pag.3

HYDRAULIC-MOTORS. Radial Piston Motors with fixed displacement RM...X series V g = 250 cm 3 /rev cm 3 /rev

GM SERIES TECHNICAL CATALOG. Crankshaft Design Radial Piston Hydraulic Motors

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

SAI GM Series Piston Hydraulic Motor Crankshaft Design Radial Piston Motors

TMF 600 ( cm³/rev.)

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE

SCM M2. Other advantages:

PACKING, HANDLING, TRANSPORTING AND STORING MOTORS

TPV Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 501 / 1009 / E

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

TPF 60 (36,16 49,94 cm³/rev.)

Fixed Displacement Bent Axis Axial Piston Motors TMB 700

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

BENT AXIS PISTON MOTORS SERIES HPM FLANGE ISO HPM. pag.3

Axial Piston Fixed Motor A2FM

High Torque Low Speed Motors MR - MRE

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

MOTOR SCM M2

SCM ISO. SCM ISO is a range of robust axial piston motors especially suitable for mobile hydraulics.

OPERATING MANUAL. Black Bruin hydraulic motors S-series model D

High Torque Low Speed Motors MRT - MRTE - MRTF

Radial piston hydraulic motor Hägglunds CAb

Radial piston motor for integrated drives MCR-H

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMC 045. Staffa Fixed Displacement Hydraulic Motor

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps

IGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

RA / Radial Piston Motor Model MR, MRE Fixed Displacement. Table of Contents. Replaces: RA /10.95

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

MOTOR SCM ISO

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO

External gear motor High Performance AZMB

2.4 HEAVY DUTY SERIES

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

1.3 HIGH PRESSURE SERIES

SCM DIN. Other advantages:

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Fixed Displacement Radial Piston Hydraulic Motor Staffa, Series B

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

High Pressure Gear Pumps KP 5

VIS (Valve-In-Star) Hydraulic Motor

CONTENT Axial Piston Motors and Pumps Fixed Displacement. Technical Specification Guide...2. Hydraulic motor MAP Hydraulic motor MAP50...

Disc Valve Hydraulic Motors

Radial piston motor for track drives MCR-T

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

TPV 4000 (EX 28-41) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE TRANSMISSION LINE OF HANSA-TMP HT 16 / M / 280 / 1008 / E

Hydraulic Motor/Pump Series F11/F12 zp12

2.3 MEDIUM HEAVY DUTY SERIES

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Variable displacement axial piston pumps,

3.3 VARIABLE DISPLACEMENT MECHANICAL COMPENSATION

Radial piston motors for industrial applications MCR-D

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

HYDRAULICS VINCKE HYDRAULIC PUMPS

S T F. Ultra modern manufacturing facility were the best team work in harmony to produce very high quality hydraulic motors

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

521B0850 DKCFN.PD.013.FA5.02

Product Manual VIKING. EN397-3a 1999

Modular Unit 6MB HYDRANOR MODULAR UNIT 6MB GENERAL DESCRIPTION. 6MB-200-**-2C General Arrangement. Rev

Variable displacement axial piston pumps,

Axial Piston Variable Double Pump A8VO

PISTON MOTORS FOR CLOSED LOOP SYSTEMS types HMF/A/V/R-02

HPC. Dual Displacement Staffa Radial Piston Motors HT 18 / C / 150 / 1007 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Variable Displacement Open Loop Circuit Axial Piston Pumps AR Series

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

HEAVY DUTY HYDRAULIC MOTORS

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

External Gear Pumps Series F

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

Radial piston motor for frame integrated drives MCR-A

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

RS* /110 ED DOUBLE-ACTING THROTTLE FLOW CONTROL VALVE SERIES 30. Q max (see table of performances) THREADED PORTS CARTRIDGE TYPE

Radial piston motor for compact drives MCR-C

OML and OMM Orbital motors. Technical Information

Eaton Char-Lynn Low Speed, High Torque Motors. Orbit motor

Internal Gear Unit. for motor/pump function Series QXM. Reference: 100-P US-10 1/18. Issue:

Transcription:

R8 C O 2DISPLACEMENT U PL E ITALY DUAL DISPLACEMENT HYDRAULIC MOTOR

R8C SERIES TECHNICAL CATALOGUE The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 2018 ITALGROUP S.R.L. - ALL RIGHTS RESERVED - R8C rev.00 - Oct. 2018

GENERAL INDEX FORMULAS Pag. 3 INTRODUCTION - GENERAL INFORMATION Pag. 4-6 R8C ORDERING CODE Pag. 7 TECHNICAL DATA Pag. 8-15 HYDRAULIC FLUID RECOMMENDATIONS Pag. 9 DRAIN RECOMMENDATIONS - FLUSHING Pag. 18-19 STANDARD SHAFT SEAL FEATURES Pag. 20-21 MOTOR HANDLING AND STORAGE Pag. 22-23 MAINTENANCE OPERATION Pag. 23 MOTOR INSTALLATION AND STARTUP Pag. 24-32 SPECIAL FEATURES Pag. 33 TROUBLESHOOTING Pag. 34-35 UNIT CONVERSIONS Pag. 36 R8C H1 Pag. 37-50 R8C H3 Pag. 51-62 R8C H4 Pag. 63-74 R8C H5 Pag. 75-86 R8C H55 Pag. 87-96 R8C H6 Pag. 97-109 R8C H7 Pag. 111-124 MOTOR DISTRIBUTORS Pag. 126-127 TACHOMETERS Pag. 128-132 SPLINED BILLETS - SPLINED BARS Pag. 133-135 ADAPTOR FLANGES Pag. 136-137 VALVES Pag. 139-156 CONTACT US - REACH US Pag. 157 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden.

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8D rev.00 - Oct. 2018

FORMULAS Torque [Nm] = Specific torque [Nm/bar] * Pressure [bar] Torque [Nm] = Displacement [cc/rev] 62.8 * Pressure [bar] Power [kw] = Torque [Nm] * 9549 Speed [rpm] Power [CV] = Torque [Nm] * 7023 Speed [rpm] Speed [rpm] = Flow [l/min] * 1000 Displacement [cc/rev] Displacement [cc/rev] = Torque [Nm] * Pressure [bar] 62,8 Flow [l/min] = Displacement [cc/rev] * Speed [rpm] 1000 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 3

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE INTRODUCTION GENERAL INFORMATION Carefully read the use and maintenance manual before start-up the motor. The use and maintenance manual must be placed near to motor installation location in order to guarantee operators easy access to the instruction manual. For further information please contact Italgroup. MOTOR DESCRIPTION IAC series motors are dual displacement radial piston hydraulic motors (generally indicated as LSHT motors, low speed high torque motors) with a rotating shaft (1) and a stationary housing (2). The pistons (3) are located radially and the working fluid provide the mechanical force that push the pistons against the eccentric cam (4), providing the shaft ouput torque. The inlet and outlet flow to and from the pistons is regulated by a distributor (5) that provides the oil distribution correct timing. The pistons transfer the forces to the eccentric shaft through a connecting rod (6). Acting in the adequate way (increasing or reducing the oil flow coming from the pump) the motor rotational speed can be increased or reduced. In addition, there is an hydraulic mechanism (7) that control the motor displacement. 2 6 3 5 1 8 9 4 7 4 R8C rev.00 - Oct. 2018

R8C SERIES Hydraulic motors of the R8C series are single displacement crankshaft radial piston motors. Thanks to great variety of accessories R8C series can be used in a wide range of applications such as: marine equipments winches offshore equipments conveyors injection moulding machines steel bending machines fork lifts trucks skid steer loaders dumpers agricultural and forestry machines municipal vehicles airport machinery PRODUCT FEATURES: High volumetric and mechanical efficiencies Very smooth running at low speeds High starting torque / constant torque Wide speed range Compact Design Low maintenance and high reliability Bi-directional High radial and axial force allowed Speed sensor available Built-in valves available The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 5

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE INTRODUCTION - GENERAL INFORMATION Motor Max torque @275 bar [Nm] Continuous power with flushing [kw] [cc] Continuous power without flushing [kw] [Nm/bar] IAC 195 H1 765 45 36 IAC 250 H1 995 48 38 IAC 500 H3 1885 78 65 IAC 800 H4 3150 125 105 IAC 1600 H5 6350 172 142 IAC 2200 H55 8880 170 140 IAC 3000 H6 12800 270 180 IAC 4600 H7 19300 290 195 IAC 5400 H7 22200 265 195 Italgroup motor code Cross reference motor code R8C 500/B30 H3 HMC 30 R8C 800/B45 H4 HMC 45 R8C 1400 H5 HMC 80 R8C 2200 H55 HMC 125 R8C 3000 H6 HMC 200 R8C 4600 H7 HMC 270 R8C 5400 H7 HMC 325 R8C 500/C H3 MRD 450 - MRDE 500 R8C 800/C H4 MRD 700 - MRDE 800 R8C 1400/C H5 MRD 1100 - MRDE 1400 R8C 3000/C H6 MRD 2800 - MRDE 3100 R8C 800/MRH H4 MRH2-45 R8C 1400/MRH H5 MRH2-95 R8C 3000/MRH H6 R8C 4600/MRH H7 R8C 195-250/S H1 MRH2-190 MRH2-270 GM1 / M1 6 R8C rev.00 - Oct. 2018

R8C - ORDERING CODE R8C - - - - - - - - - - - - - - - - - - - - DISPLACEMENT INTERCHANGEABILITY SERIE 195 /S H1 250 /BH See pag. 37-50 /B30 500 /C H3 See pag. 51-62 /MRH /B45 800 /C H4 /MRH See pag. 63-74 SHAFT A0 A1 A11 A12 A13 A2 A21 A3 A31 A32 A4 TACHOMETER TA TB TT1 TQ1 EST EST30 EST31 EST32 EST33 See pag. 128-132 SPECIAL FEATURES MP SPSL HPS CCW See pag. 33 NIP See pag. 33 Z - - Italgroup internal code /C 1400 /MRH H5 /BD5 See pag. 75-86 2200 /MRH H55 See pag. 87-96 /MRH 3000 /GM6 H6 /MR1400 See pag. 97-109 4600 5400 /MRH H7 See pag. 111-124 DISTRIBUTOR D31B D31BJ D36B D36BJ D310B D310BJ D40 D40J D47 D47J D416 D416J D75 D75J D90 D90J See pag. 126-127 DISPLACEMENT CHANGE FITTING AND ACCESSORIES XY XY-SV C3-SV C3-12 SV C3-24 SV C3-HY SV C3-12 CSV C3-24 CSV C3-HY CSV See pag. 24-32 SPLINED BILLET SPLINED BAR SB3 SB6 SB9 SB14 SB21 SB27 SB32 SB5 SB7 SB10 SB16 SB24 SB30 B8076 See pag. 133-135 MAXIMUM AND MINIMUM DISPLACEMENTS The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 7

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H1 TECHNICAL DATA R8C 195 H1 Displacement (*) [cc] 195 175 150 125 100 95 75 69 Th. specific torque [Nm/bar] 3,1 2,8 2,4 2 1,6 1,5 1,2 1,1 Continuous speed [rpm] 850 850 1000 1000 1050 1050 1100 1100 Peak speed [rpm] 950 1050 1150 1150 1200 1200 1250 1250 Minimum speed [rpm] 3 3 3 4 4 4 5 5 Mechanical efficiency [%] 89,5 89,2 89 88,5 88 87,8 87 85,5 Starting efficiency [%] 84,5 84,2 84 83,5 83 82 80 77 Continuous power (**) [kw] 37 35 33 31 30 28 21 19 Cont. power with flushing [kw] 46 43 39 37 36 33 27 25 Continuous pressure [bar] 270 270 270 270 250 250 250 250 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 Flushing flow [l/min] 6 6 6 6 6 6 6 6 Dry weight [kg] 26 26 26 26 26 26 26 26 R8C 250 H1 Displacement (*) [cc] 257 232 195 175 150 125 100 95 Th. specific torque [Nm/bar] 4,1 3,7 3,1 2,8 2,4 2 1,6 1,5 Continuous speed [rpm] 810 810 850 850 1000 1000 1050 1050 Peak speed [rpm] 920 920 950 1050 1150 1150 1200 1200 Minimum speed [rpm] 3 3 3 3 3 4 4 5 Mechanical efficiency [%] 88,5 88,2 88 87,5 87 86,8 86 84,5 Starting efficiency [%] 83,5 83,2 83 82,5 82 81 79 76 Continuous power (**) [kw] 39 38 37 35 33 31 29 29 Cont. power with flushing [kw] 50 47 46 44 41 39 35 33 Continuous pressure [bar] 250 250 250 250 250 250 250 250 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 Flushing flow [l/min] 6 6 6 6 6 6 6 6 Dry weight [kg] 26 26 26 26 26 26 26 26 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 40 kw and starting efficiency is 90%, estimated required power is 40/0.9 = 44,44 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 8 R8C rev.00 - Oct. 2018

R8C H3 TECHNICAL DATA R8C 500 H3 Displacement (*) [cc] 492 442 393 344 292 Th. specific torque [Nm/bar] 7,8 7 6,3 5,5 4,7 Continuous speed [rpm] 500 550 600 630 630 Peak speed [rpm] 600 650 680 700 700 Minimum speed [rpm] 2 2 2 2 2 Mechanical efficiency [%] 87,5 86 85 83,6 82,4 Starting efficiency [%] 82,5 81 80 77,2 74,3 Continuous power (**) [kw] 67 67 67 62 52 Cont. power with flushing [kw] 80 80 80 72 62 Continuous pressure [bar] 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 Flushing flow [l/min] 8 8 8 8 8 Dry weight [kg] 68 68 68 68 68 Displacement (*) [cc] 255 197 147 98 Th. specific torque [Nm/bar] 4,1 3,1 2,3 1,6 Continuous speed [rpm] 650 700 700 700 Peak speed [rpm] 750 800 900 1000 Minimum speed [rpm] 3 3 3 4 Mechanical efficiency [%] 82 80 78 73,4 Starting efficiency [%] 69,6 62,1 52 30 Continuous power (**) [kw] 49 39 25 16 Cont. power with flushing [kw] 56 42 29 19 Continuous pressure [bar] 270 250 250 250 Intermittent pressure [bar] 310 310 310 310 Peak pressure [bar] 350 350 350 350 Flushing flow [l/min] 8 8 8 8 Dry weight [kg] 68 68 68 68 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 40 kw and starting efficiency is 90%, estimated required power is 40/0.9 = 44,44 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 9

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H4 TECHNICAL DATA R8C 800 H4 Displacement (*) [cc] 792 660 575 493 410 Th. specific torque [Nm/bar] 12,6 10,5 9,2 7,8 6,5 Continuous speed [rpm] 450 550 620 650 650 Peak speed [rpm] 550 700 720 750 800 Minimum speed [rpm] 2 2 2 2 2 Mechanical efficiency [%] 90,8 90,4 88,5 88 87,4 Starting efficiency [%] 84,8 84,4 82,6 79 75 Continuous power (**) [kw] 108 94 84 72 55 Cont. power with flushing [kw] 128 112 100 86 66 Continuous pressure [bar] 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 Flushing flow [l/min] 10 10 10 10 10 Dry weight [kg] 92 92 92 92 92 Displacement (*) [cc] 328 273 245 165 Th. specific torque [Nm/bar] 5,2 4,3 3,9 2,6 Continuous speed [rpm] 700 700 700 700 Peak speed [rpm] 800 850 850 900 Minimum speed [rpm] 2 2 3 3 Mechanical efficiency [%] 84,5 82,4 82 60,2 Starting efficiency [%] 70,2 68,3 60,8 43,3 Continuous power (**) [kw] 55 43 41 19 Cont. power with flushing [kw] 66 51 49 25 Continuous pressure [bar] 250 250 250 250 Intermittent pressure [bar] 310 310 310 310 Peak pressure [bar] 350 350 350 350 Flushing flow [l/min] 10 10 10 10 Dry weight [kg] 92 92 92 92 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 40 kw and starting efficiency is 90%, estimated required power is 40/0.9 = 44,44 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 10 R8C rev.00 - Oct. 2018

R8C H5 TECHNICAL DATA R8C 1400 H5 Displacement (*) [cc] 1600 1499 1393 1313 1235 1150 1070 980 900 820 Th. specific torque [Nm/bar] 24,5 23,9 22,2 20,9 19,7 18,3 17 15,6 14,3 13 Continuous speed [rpm] 370 400 410 435 440 460 480 490 495 520 Peak speed [rpm] 450 500 500 500 550 550 575 600 600 600 Minimum speed [rpm] 1 1 1 1 1 1 1 1 1 2 Mechanical efficiency [%] 94,2 94 93,9 93,7 93,5 93,4 93,2 93 92,6 92,3 Starting efficiency [%] 88,2 88 86,5 85,3 85,1 82,6 81,3 79,8 77,9 76 Continuous power (***) [kw] 145 142 137 132 132 127 122 116 111 106 Cont. power with flushing [kw] 174 172 167 157 157 152 147 139 133 127 Continuous pressure [bar] 270 270 270 270 270 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 350 350 Flushing flow [l/min] 12 12 12 12 12 12 12 12 12 12 Dry weight [kg] 173 173 173 173 173 173 173 173 173 173 Displacement (*) [cc] 737 655 574 492 410 328 246 164 82 0 Th. specific torque [Nm/bar] 11,7 10,4 9,1 7,8 6,5 5,2 3,9 2,6 1,3 0 Continuous speed [rpm] 545 600 600 600 600 600 600 600 1000 1000 Peak speed [rpm] 650 700 700 700 800 800 800 800 1200 1500 Minimum speed [rpm] 2 2 2 2 2 3 3 3 - - Mechanical efficiency [%] 91 89,3 87 83 81,7 75,5 65,7 60,5 0 0 Starting efficiency [%] 72,9 83,2 65 59,2 51 39 18 0 0 0 Continuous power (***) [kw] 106 106 96 71 56 41 26 19 0 0 Cont. power with flushing [kw] 127 127 111 91 76 56 36 23 0 0 Continuous pressure [bar] 250 250 250 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 12 12 12 12 12 12 12 12 15 15 Dry weight [kg] 173 173 173 173 173 173 173 173 173 173 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 120 kw and starting efficiency is 88,2%, estimated required power is 120/0.882 = 136 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 11

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H55 TECHNICAL DATA R8C 2200 H55 Displacement (*) [cc] 2200 2049 1970 1800 1640 1470 1310 1150 Th. specific torque [Nm/bar] 35 32,6 31,3 28,6 26,1 23,4 20,9 18,3 Continuous speed [rpm] 280 305 320 350 380 410 440 470 Peak speed [rpm] 320 340 360 400 430 470 500 540 Minimum speed [rpm] 1 1 1 1 1 1 1 1 Mechanical efficiency [%] 92,2 92,2 92,2 92,2 91 90 88 86,5 Starting efficiency [%] 81 80,6 79,6 77,5 74,6 71,5 67,5 62,2 Continuous power (***) [kw] 140 140 135 125 116 108 100 90 Cont. power with flushing [kw] 170 170 165 155 145 135 127 110 Continuous pressure [bar] 270 270 270 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 Flushing flow [l/min] 10 10 10 10 10 10 10 10 Dry weight [kg] 210 210 210 210 210 210 210 210 Displacement (*) [cc] 980 820 655 490 330 160 82 0 Th. specific torque [Nm/bar] 15,6 13,1 10,4 7,8 5,3 2,5 1,3 0 Continuous speed [rpm] 610 620 620 640 640 640 1000 1000 Peak speed [rpm] 700 700 720 720 800 800 1200 1500 Minimum speed [rpm] 1 2 2 2 3 5 - - Mechanical efficiency [%] 82,2 81,8 78,2 76 73 26 0 0 Starting efficiency [%] 55,3 45,8 31,5 0 0 0 0 0 Continuous power (***) [kw] 83 75 65 50 25 5 0 0 Cont. power with flushing [kw] 105 90 80 65 40 10 0 0 Continuous pressure [bar] 270 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 10 10 10 10 10 12 15 15 Dry weight [kg] 210 210 210 210 210 210 210 210 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 150 kw and starting efficiency is 86%, estimated required power is 150/0.86 = 174,4 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 12 R8C rev.00 - Oct. 2018

R8C H6 TECHNICAL DATA R8C 3000 H6 Displacement (*) [cc] 3085 2950 2790 2620 2460 2290 2130 1970 1800 1640 Th. specific torque [Nm/bar] 49,1 47 44,4 41,7 39,2 36,5 33,9 31,4 28,7 26,1 Continuous speed [rpm] 235 240 245 250 250 265 285 305 340 370 Peak speed [rpm] 280 280 300 300 300 320 340 350 400 420 Minimum speed [rpm] 1 1 1 1 1 1 1 1 1 1 Mechanical efficiency [%] 95 94,5 94,2 94 93,7 93,5 92,8 92,3 92 91 Starting efficiency [%] 86 85,4 84,4 83,6 82,4 82 80,2 78 76 73 Continuous power (***) [kw] 182 182 182 170 160 155 145 133 123 116 Cont. power with flushing [kw] 272 272 272 255 240 230 214 197 186 176 Continuous pressure [bar] 270 270 270 270 270 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 350 350 Flushing flow [l/min] 12 12 12 12 12 12 12 12 12 12 Dry weight [kg] 308 308 308 308 308 308 308 308 308 308 Displacement (*) [cc] 1470 1310 1150 980 820 670 490 330 160 82 0 Th. specific torque [Nm/bar] 23,4 20,9 18,3 15,6 13,1 10,7 7,8 5,2 2,5 1,3 0 Continuous speed [rpm] 400 425 455 490 520 600 600 600 600 1000 1000 Peak speed [rpm] 450 475 500 540 580 700 700 800 800 1200 1500 Minimum speed [rpm] 1 1 1 1 2 2 2 3 5 - - Mechanical efficiency [%] 90,5 88 86,2 82,3 81,7 78 76 73,2 25 0 0 Starting efficiency [%] 70 66,4 62 55,4 46,3 33 0 0 0 0 0 Continuous power (***) [kw] 107 100 100 100 90 80 70 40 8 0 0 Cont. power with flushing [kw] 161 150 150 150 135 96 90 60 11 0 0 Continuous pressure [bar] 270 250 250 250 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 12 12 12 12 12 12 12 12 12 15 15 Dry weight [kg] 308 308 308 308 308 308 308 308 308 308 308 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 120 kw and starting efficiency is 88,2%, estimated required power is 120/0.882 = 136 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 13

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 4600 H7 TECHNICAL DATA R8C 4600 H7 Displacement (*) [cc] 4617 4177 3650 3280 2950 2620 2290 1970 Th. specific torque [Nm/bar] 73,5 66,5 58,1 52,2 47 41,7 36,5 31,4 Continuous speed [rpm] 150 158 168 175 210 235 275 305 Peak speed [rpm] 170 185 210 230 255 280 330 380 Minimum speed [rpm] 1 1 1 1 1 1 1 1 Mechanical efficiency [%] 95,3 95,1 94,5 94,4 93,3 92,4 91,5 90,1 Starting efficiency [%] 85,1 84 83,3 82,5 81,2 80,1 78 75,2 Continuous power (***) [kw] 197 192 177 157 147 136 120 110 Cont. power with flushing [kw] 292 272 252 237 216 200 180 165 Continuous pressure [bar] 270 270 270 270 270 270 270 250 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 Flushing flow [l/min] 12 12 12 12 12 12 12 12 Dry weight [kg] 405 405 405 405 405 405 405 405 Displacement (*) [cc] 1640 1310 980 655 492 328 164 82 0 Th. specific torque [Nm/bar] 26,1 20,9 15,6 10,4 7,8 5,2 2,6 0 0 Continuous speed [rpm] 380 435 460 495 520 550 600 1000 1000 Peak speed [rpm] 470 530 550 600 600 650 700 1200 1500 Minimum speed [rpm] 1 1 1 2 2 3 6 - - Mechanical efficiency [%] 86,5 83 78,4 76,2 66 46,4 25 0 0 Starting efficiency [%] 72,4 67,2 58 41 23,7 0 0 0 0 Continuous power (***) [kw] 110 95 75 50 45 25 10 0 0 Cont. power with flushing [kw] 165 140 112 80 65 32 10 0 0 Continuous pressure [bar] 250 250 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 12 12 12 12 12 12 12 15 15 Dry weight [kg] 405 405 405 405 405 405 405 405 405 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 160 kw and starting efficiency is 85,1%, estimated required power is 160/0.851 = 188 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 14 R8C rev.00 - Oct. 2018

R8C 5400 H7 TECHNICAL DATA R8C 5400 H7 Displacement (*) [cc] 5326 5080 4915 4588 4097 3650 3280 2950 2620 Th. specific torque [Nm/bar] 84,8 80,9 78,2 73 65,2 58,1 52,2 47 41,7 Continuous speed [rpm] 130 135 140 150 160 170 190 215 230 Peak speed [rpm] 145 150 155 165 185 210 235 260 290 Minimum speed [rpm] 1 1 1 1 1 1 1 1 1 Mechanical efficiency [%] 95,2 95 95 95 95 94,4 94,3 93,2 92 Starting efficiency [%] 86 85,8 85,8 85,4 85,2 83 82,2 82 79,8 Continuous power (***) [kw] 197 197 197 192 180 165 155 145 135 Cont. power with flushing [kw] 265 262 262 256 245 230 230 215 200 Continuous pressure [bar] 250 250 250 250 250 250 250 250 250 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 350 Flushing flow [l/min] 12 12 12 12 12 12 12 12 12 Dry weight [kg] 405 405 405 405 405 405 405 405 405 Displacement (*) [cc] 2295 1640 1311 980 655 492 328 164 0 Th. specific torque [Nm/bar] 36,5 26,1 20,9 15,6 10,4 7,8 5,2 1,6 0 Continuous speed [rpm] 280 375 445 470 500 520 550 1000 1000 Peak speed [rpm] 335 450 530 550 600 600 650 1200 1500 Minimum speed [rpm] 1 1 1 1 2 2 3 - - Mechanical efficiency [%] 91,5 86 82,3 78,3 76,2 66,2 46,5 0 0 Starting efficiency [%] 77,7 72,1 67 58 41 24 0 0 0 Continuous power (***) [kw] 125 125 95 95 60 40 28 0 0 Cont. power with flushing [kw] 185 185 135 135 80 60 32 0 0 Continuous pressure [bar] 250 250 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 12 12 12 12 12 12 12 15 15 Dry weight [kg] 405 405 405 405 405 405 405 405 405 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 160 kw and starting efficiency is 86%, estimated required power is 160/0.86 = 186 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 15

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE HYDRAULIC FLUID RECOMMENDATIONS Fluid selection Optimal viscosity selection In general, we recommend the use of hydraulic oils with minimum viscosity index of 95, with anti-wear additives (ISO HM and HV). Once normal working temperature is reached, the drain oil viscosity must be at least 35-40 cst, preferably in the range from 40 to 60 cst. HE oils (ecological fluids) are allowed, but must be used with particular attention, because them can influence the motor seals compatibility, and can reduce motor performances and life. Please contact us in case of HE oils usage. Referring the first approximated selection to the room temperature, we advice the following: Room temperature -20 C/0 C BP ENERGOL HLP HM 22-15 C/+5 C BP ENERGOL HLP HM 32-8 C/+15 C BP ENERGOL HLP HM 46 0 C/+22 C BP ENERGOL HLP HM 68 +8 C/+30 C BP ENERGOL HLP HM 100 Oil -20 C/+5 C BP BARTRAN HV 32-15 C/+22 C BP BARTRAN HV 46 0 C/+30 C BP BARTRAN HV 68 ATF (automatic transmission fluid) oils, SAE 10-20-30 W oils, multigrade motor oils (SAE 15 W 40, 10 W 40), universal oils, can also be used. Always fill the motor (please refer to the DRAIN RECOMMENDATIONS section) with the selected hydraulic fluid before motor start-up. During cold start-up avoid high-speed operation until the system reach the working temperature, in order to provide an adequate lubrication. Every 5-8 C of increase respect to the optimal working temperature for the selected oil, the hydraulic fluid life decrease of about 40-50% (refer to OXIDATION section). Consequently, the motor lifetime will be affected by the working temperature increase respect to the optimal working temperature of the selected oil. The maximum continuous working temperature is 70 C, the temperature must be measured from motor drain line. If the motor doesn t have a drain line, the temperature must be evaluated at the return line port. Fire resistant oil limitations Max cont. Pressure [bar] Max int. Pressure [bar] Max Speed [rpm] HFA, 5-95% oil-water 103 138 50% HFB, 60-40% oil-water 138 172 100% HFC, water-glycol 103 138 50% HFD, ester phosphate 250 293 100% 16 R8C rev.00 - Oct. 2018

Filtration Hydraulic systems oil must always be filtered. The choice of filtration grade derives from needs of service life and money spent. In order to obtain stated service life it is important to follow our recommendations concerning filtration grade. When choosing the filter it is important to consider the amount of dirt particles that filter can absorb and still operate satisfactorily. For that reason we recommend filters showing when you need to substitute filtering cartridge. 25 μm filtration required in most applications 10 μm filtration in closed circuit applications Oxidation Hydraulic oil oxidizes with time of use and temperature. Oxidation causes changes in colour and smell, acidity increase or sludge formation in the tank. Oxidation rate increases rapidly at surface temperatures above 60 C, in these situations oil should be checked more often. The oxidation process increases the acidity of the fluid; the acidity is stated in terms of the neutralization number. Oxidation is usually slow at the beginning and then it increases rapidly. A sharp increase (by a factor of 2 to 3) in neutralization number between inspections shows that oil has oxidized too much and should be replaced immediately. Water content Oil contamination by water can be detected by sampling from the bottom of the tank. Most hydraulic oils repel the water, which then collects at the bottom of the tank. This water must be drained off at regular intervals. Certain types of transmission oils and engine oils emulsify the water; this can be detected by coatings on filter cartridges or a change in the colour of the oil. In such cases, obtain your oil supplier advice. Degree of contamination Heavy contamination of the oil causes wear rising in hydraulic system components. Contamination causes must be immediately investigated and remedied. Analysis It is recommended oil being analyzed every 6 months. The analysis should cover viscosity, oxidation, water content, additives and contamination. Most oil suppliers are equipped to analyze oil state and to recommend appropriate action. Oil must be immediately replaced if the analysis shows that it is exhausted. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 17

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE DRAIN RECOMMENDATIONS MOTOR AXIS HORIZONTAL Leakage line Leakage line Check valve 1 bar setting Plug Plug 50 min MOTOR AXIS VERTICAL, SHAFT DOWN 50 min Leakage line 50 min Plug Leakage line Plug 50 min 50 min 50 min 50 min Check valve 1 bar setting 50 min 50 min MOTOR AXIS VERTICAL, SHAFT UP Leakage line using an additional drain (on request) 50 min 50 min 50 min Leakage line using an additional drain (on request) Leakage line Plug Plug Plug Plug Check valve Plug 1 bar setting Check valve 1 bar setting LEAKAGE LINE CONNECTION Always fill the motor with hydraulic fluid before start-up. Arrange piping in a way that the motor cannot drain off and cannot generates air bubbles into the motor case. Under certain conditions may be is necessary to arrange a check valve in order to help avoiding the motor drain off. Always check carefully that the leakage line pressure doesn t overcome 10 bar pressure: therefore leakage lines must be shorter as possible and with a minimum flow resistance. 18 R8C rev.00 - Oct. 2018

FLUSHING Motor Flushing flow [l/min] R8C H1 6 R8C H3 8 R8C H4 10 R8C H5 12-15 (*) R8C H55 - R8C H6 12-15 (*) R8C H7 12-15 (*) Important note: the above value are approximated. The correct way to operate is the following: the flushing flow is adequate if during the motor operation the drain oil viscosity be at least 35-40 cst, preferably in the range from 40 to 60 cst. Maximum continuous case pressure 6 bar (10 bar peak pressure). Special seals for 20-25 bar continuous case pressure are available upon request (ordering code: HPS). (*) The flushing flow for lower displacements that are used for freewheeling at 1000 rpm, must be higher than flushing flow for normal working conditions, and around 15 l/min. FLUSHING OUTLET PORT Please note: the flushing outlet port must always be located in the highest possible position. MAXIMUM CASE PRESSURE 6 bar continuous 10 bar peak For standard R8C motors FLUSHING INLET PORT The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 19

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE STANDARD SHAFT SEAL FEATURES Features Type: BABSL Form: AS DIN 3760 Material: SIMRIT 72 NBR 902 SIMRIT 75 FKM 595 Material SIMMERRING radial shaft seal with rubber covered O.D., short, flexibility suspensed, spring loaded sealing lip and additional dust lip: see Part B/SIMMERRING, sections 1.1 and 2. Application Sealing lip and O.D.: Acrylonitrile-butadiene rubber with 72 Shore A hardness (designation: SIMRIT 72 NBR 902) Fluoro rubber with 75 Shore A hardness (designation: SIMRIT 75 FKM 595) Metal insert: Plain steel DIN 1624 Spring: Spring steel DIN 17223 Operating conditions See Part B/ SIMMERRING, sections 2. 4. Media: mineral oils, synthetic oils Temperature: -40 C to +100 C (SIMRIT 72 NBR 902) -40 C to +160 C (SIMRIT 75 FKM 595) Surface speed: up to 5 m/s Working pressure: see diagram on next page, pressure is function of surface speed (i.e. of rotating speed and shaft diameter) 20 R8C rev.00 - Oct. 2018

Housing and machining criteria See Part B/ SIMMERRING, sections 2. Shaft: Tolerance: ISO h11 Concentricity: IT 8 Roughness: Ra=0.2-0.8 μm Rz=1-4 μm Rmax=6 μm Hardness: 45-60 HRc Roughness: non oriented; preferably by plunge grinding Housing: Tolerance: Roughness: ISO H8 Rmax<25 μm Pressure diagram Special seals for 20-25 bar continuous case pressure are available upon request (ordering code: HPS). Refer to page 23 for more information. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 21

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE MOTOR HANDLING AND STORAGE Motor handling The motor must be correctly packed during transport and correctly stored into the warehouse in order to avoid eventual damages that can make the motor functioning not adequate. During handling operations, make sure that the motor shaft and tachometer shaft (if present) don t receive any hit, in order to avoid motor damage. During all operations of lifting and handling, never movimentate motors by hand but use adequate tools. In order to avoid that motor can falls, creating danger for authorized working persons in the nearings, use one of following methods: - use lifting slings of adequate capacity; - use adequate eyebolt using the thread hole in the shaft end. Refer to the following pictures. Storage Storage must be carefully made using adequate storing tools (for example boxes, pallets, etc...) that can guarantee that the motor is stable and cannot move without control, in order to avoid damage problems. Make sure that the weight of the motor doesn t be substained by the motor shaft or by the tachometer shaft (if present). R8C series motors are supplied together with plastic plugs, that keep the hydraulic oil (that was used during final test in Italgroup testing workbench) inside the motor. A thin oil film is present on the internal motor parts, whereas the external parts are covered with antirust oil that prevents damage from oxidation and corrosion. Therefore the motors can be safely stored into the customer warehouse without performance losses for long periods (up to 4-6 months). The storing location must has some important characteristics: - room temperature comprised between -15 C and +55 C without fast and/or excessives temperature excursions; - low relative humidity; - absence of aggressive and corrosive medias in the motor nearings. 22 R8C rev.00 - Oct. 2018

MAINTENANCE OPERATIONS In particular, if motor should be motionless for more than 4-6 months, it must be protected against internal rust. Proceed as follows: - fill the motor case with hydraulic oil. After that the motor case is full of oil, close it with a screw plug; - fill the motor also from inlet or outlet port. Turn the shaft by hand (the shaft must make about one revolution) and finally close the inlet and outlet ports. Maintenance operations Please note that the plastic plugs are necessary not only to keep the hydraulic oil inside the motor, but even to avoid that dirt and other fluids (like water for example) can enter into the motor and create damage during storing or during motor start-up. Therefore make sure all drain ports, supply ports and discharge ports are closed during motor handling and storing. If plugs are missing, use plastic plugs or adequate systems in order to guarantee that the motor is well protected by dirt and other fluids. All the assembly and maintenance works must be performed when the motor is stopped and not connected to any power source, in order to avoid an accidental start-up. In addition the pressure inside the motor must be set to zero (the motor must be depressurized) before to perform maintenance operations. The motor maintenance must be performed by instructed and experienced personnel only, following carefully Italgroup advices and procedures. R8C series motors are internally lubricated by the operating fluid, if the motors are used according to the technical data reported into the R8C catalogue, they need very limited maintenance operations. In order to achieve good performances, long bearings lifetime and safe working, the working fluid must be carefully selected in function of the operating parameters (a fundamental parameter is the ambient temperature range). In case of fire resistence fluid usage, some limitation on pressure and speed can be required. Refer to hydraulic fluid recommendations section for more information. If required please contact Italgroup technical department for further information. Motor parts Motor shaft, cam ring, rollers, pins, screws, distributor bush, rotating distributor, distributor joint, pistons, connecting rod, ring for rod Motor case, cylinders, motor flange, distributor body Distributor disk, piston shoes Slippers O-Rings Radial shaft seal rings Material Steel Cast iron Bronze Charged PTFE, PTFE Elastomer Elastomer / charged PTFE The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 23

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE MOTOR INSTALLATION AND STARTUP Motor installation and start-up The motor, after testing, it s packed in different ways that depends by customer and/or logistic requirements. The motor must be carefully moved from his box or pallet, with the assistance of correctly sized movimentation tools, like eyebolts (all the motors has a thread hole in the shaft end, please refer to the R8C general catalogue, shafts section) or lifting slings. When the motor is moved from one place to another always be very careful and act in a way that the motor is stable and under control during movimentation (refer to handling and storage section for more details). Before mount the motor, check carefully the absence of damage happened for example during transportation and/or storing. For mounting dimensions please refer to the R8C installation drawings. The motor must be installed using the correct screws size (we recommends the use of 10.9 and 12.9 class resistance fixing screws) and must be placed on a structure that is capable to correctly support the motor during functioning: for this reason the structure must not only be able to support the motor weight but must also assure the absence of vibration during operation and must win the reaction forces that are generated by the working torque. Regarding the motor fitting design, the concentricity between the centering diameter (spigot) and shaft (both splined or parallel) must be assured with a strict tolerance (please refer to the following general indication). If the concentricity between the shaft and the centering diameter and/or fixing holes is not respected, in the worst case the motor can have an unusual failure or can work only with low performances. Splined adaptors (splined billets) are available upon request. C Ø0,15 A B C D ØA H6 ØB 0,05 0,05 A 0,05 B ØB ØA D B 3.2 3.2 A F E E+1 +1 0 0.1 F+1 +1 0 24 R8C rev.00 - Oct. 2018

Hoses and piping must be clean and free from contamination. Use proper hoses for oil connection, both for inlet and outlet main ports, and for drain line. Refer to hoses and fitting constructors in order to correctly size and select hoses and fittings. In order to keep control on the oil compressibility keep hoses to the minimum recommended size and select pipelines most rigid as possible. The motor can be mounted in any position (refer also to drain recommendations section). In run-away conditions you must use counterbalance valves. When the motor is installed vertically with shaft pointing upwards, consult our technical department. If the motor is connected to high inertial loads, the hydraulic system must be designed to prevent peaks of pressure and cavitation. Consider the use of relief valves, possibly directly mounted on motor distributor in case the application can generates pressure peaks at the motor ports: the relief valve should be able to discharge all the flow (or at least a good part of it) with a limited pressure increase. Italgroup can provide differents valve types that can be placed directly on the motor distributor (please refer to Italgroup valves technical catalogue). Motor case and pistons must be completely filled with oil before starting. Do not load motor to maximum working pressure instantly. During cold start-up avoid high-speed operation until the system reach the working temperature. Connect the case drain directly to tank, and avoid excessive drain line pressure losses (the case drain pressure must not exceed 10 bar continuous pressure for R8C serie standard motors). The case drain port on the motor must be located on the highest point of the installation to ensure that the motor will always be full of oil. (See drain recommendations page for more details) Maximum oil temperature must not exceed 70 C. Heath exchangers must be used with higher temperatures. The operating fluid viscosity must always be higher than a certain minimum value (see fluid recommendation section) in order to guarantee an optimal motor internal lubrication. When the working conditions cause the motor case overheating above a critical value, the motor flushing is required. Flushing consists in the introduction of fresh oil (taken from the hydraulic circuit) into the motor case. Oil must be taken from the return line to avoid internal motor damage (the continuous motor case pressure must be maximum 6 bar). Flushing is an important operation that can be very effective to improve motor lifetime with heavy duty working conditions and improve the motor mechanical efficiency. The motor flushing, if the motor works in one direction only, can be easily performed connecting the motor return line to the lowest motor drain port. The highest motor drain port must be connected to the tank. For D75 and D90 flow distributors, the side 1/4 metallic plugs can be used for flushing circuit installation: infact the plug (corresponding to the return line port) can be removed and the connection between motor low pressure port and motor case can be correctly realized. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 25

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE MOTOR INSTALLATION AND STARTUP If the motor axis is not horizontal and/or the motor works in bidirectional operation, please contact Italgroup technical department, that can assist you to advice how to perform the desired operation in the best way. Just for your reference, Italgroup can provide you flushing valves in order to perform an effective flushing circuit. Minimum speed is very low and can reach values near to 1-2 rpm (depending on motor displacement). In case of low speed vibration a reasonable back pressure can eliminate or minimize the vibration and noise level (a general guideline value can be defined by 5-8 bar back pressure). For more information please contact our technical department. Back pressure limit for R8C series motors is 70-80 bar (back pressure occurs for example when hydraulic motors are installed in series circuit). High back pressure values are often responsible of motor overheating, so if drain temperature reach values that bring the oil viscosity under the recommended limit (refer to fluid recommendations section), perform appropriate motor flushing and/or reduce the back pressure. During start-up and in the period immediately after it, any hydraulic installation must be regurarly and carefully checked at frequent intervals. The working pressure must be checked in order to understand that it agrees with the design values. The drain line pressure for standard motors must not overcome 10 bar continuous. If leakage occurs, check the reason, correct it and carry out new measurements. Check all lines, connections, screws, etc, and tighten if necessary. Replace contaminated fluid immediately. The motor installation and start-up must be performed by instructed and experienced personnel only. Displacement change Please contact us freely to obtain further information. The displacement change can be performed in different ways. The user can use an internal or esternal pilot. In addition Italgroup can supply a cetop 3 fitting with or without Cetop 3 displacement change valve (with electric or hydraulic control). When the displacement change ports are not feeded with pressure, the motor remains at the maximum displacement: to perform the displacement change, the pilot pressure must be at least 2/3 of the motor working pressure. A minimum pressure of around 3,5 bar (the value is approximate and can have variations in function of the operating parameters) is needed in order to activate the displacement change mechanism. Please note that in freewheeling operation it is necessary supply the displacement control mechanism with an external supply pressure/flow source. This external supply source will assure that the motor displacement during the freewheeling operation remains fixed at the minimum value, avoiding IAC motor damage. 26 R8C rev.00 - Oct. 2018

The oil flow rate required to perform the displacement change can be estimated in function of many different parameters; the most important factor that determinate the required flow rate is the motor case internal leakage. The flow rate that is shown in the next table must be considered as an indicative value that depends by many system parameters and working conditions. Motor Required flow Displacement change delay IAC H1 8 l/min 0,2 s IAC H3 12 l/min 0,2 s IAC H4 15 l/min 0,25 s IAC H5 15 l/min 0,5 s IAC H6 15 l/min 0,5 s IAC H7 20 l/min 1 s The system components (pumps, motors ) present tear and wear phenomenons that are clearly variables during the system life, so the required flow rate is variable during the motor life, this variation is very difficult to estimate: for this reason the values reported must be considered as approximated and indicative values. Displacement change port configuration XY displacement change port configuration: when Y port is connected to the supply source (refer to displacement change section) the maximum displacement is activated. When the X port is connected to the supply source, the minimum displacement is activated. Please refer to the displacement change hydraulic circuit section for more details. X port 1/4 BSP Y port 1/4 BSP The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 27

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE MOTOR INSTALLATION AND STARTUP C3-SV displacement change port configuration: there is a cetop 3 standard fitting that can be used to fit a cetop 3 displacement change valve (solenoid or hydraulic operated). In addition a shuttle valve SV is integrated inside the motor distributor. Please refer to the displacement change hydraulic circuit section for more details. Pilot supply source port Cetop3 fitting C3-12 SV displacement change port configuration: the displacement change valve is solenoid operated, 12 V DC. C3-24 SV displacement change port configuration: the displacement change valve is solenoid operated, 24 V DC. C3-HY SV displacement change port configuration: the displacement change valve is hydraulic operated. Please refer to the displacement change hydraulic circuit section for more details. C3-12 SV C3-24 SV C3-HY SV 28 R8C rev.00 - Oct. 2018

Basic displacement change hydraulic circuits In all circuits, A and B identify the motor inlet/ outlet port (the motor is fully reversible, can work with same behavior in both directions), whereas L identify the motor drain port. The typical displacement change circuit is shown on the right; the displacement change pressure is taken from the higher pressure motor port (if motor works in a bidirectional way a shuttle valve, SV, is needed to make the selection between the higher and lower pressure port). To order the shown motor assembly the ordering code is XY (the displacement change port fittings are 1/4 BSP female thread). Italgroup can provide a special motor distributor with integrated shuttle valve (SV). The ordering code is XY- SV for displacement change fitting 1/4 BSP (female threads) or C3-SV for cetop 3 displacement change valve fitting. L A Y X IAC motor B SV XY-SV Y X C3-SV DCV if required Italgroup can supply solenoid or hydraulic operated displacement change valves, directly fitted on the motor (please refer to ordering code section and dimensional drawings for more information). The circuit on the right shows a complete assembly with displacement change valve and shuttle valve, included in the motor assembly. The ordering code in this case is C3-12 SV or C3-24 SV, in case the DCV is solenoid operated, or C3-HY SV if is hydraulic operated. A DCV L IAC motor Y X SV B C3-XX SV The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 29

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE MOTOR INSTALLATION AND STARTUP Advanced displacement change hydraulic circuits (with external supply source) When the working pressure can reach very low values, lower than the minimum pressure that is required for displacement change (approximatively 3,5 bar in normal conditions), an external displacement change pilot supply source is required. Please refer to the circuit on the right. The circuit on the right shows an integrated SV valve with external pilot supply: when the motor working pressure is lower than the external supply relief valve setting, the displacement change pressure is taken from the external supply source. When motor working pressure is higher than the external supply relief valve setting the displacement change pressure is taken from the motor ports. The circuit refer to the XY displacement change port configuration. A DCV Y L IAC motor Y X SV X P CV if required B XY-SV M The complete assembly with motor, displacement change valve DCV and integrated shuttle valve SV can be equipped with an external pressure supply source. Please refer to the circuit shown on the right. The ordering code in this case is C3-12 CSV or C3-24 CSV in case the displacement change valve is solenoid operated, or C3-HY CSV in case the displacement change valve is hydraulic operated (please refer to ordering code section and dimensional drawings for more information). A DCV IAC motor L B Y X SV CV P C3-XX CSV M 30 R8C rev.00 - Oct. 2018

Small displacement / freewheeling circuit A Y DCV L IAC motor Y X X SV AC XY C3 B Selecting a zero displacement IAC motor, the motor can run without load at high speed, resulting in a minimum motor torque requirement. The maximum working pressure shown in the motor technical data or the zero displacement code are relatives to a 1000 rpm shaft speed. if required M If the output shaft speed is less then 1000 rpm the maximum working pressure can be slightly increased. Consult Italgroup technical departement to obtain more details. For output shaft speed higher than 1000 rpm the application duty cycle must be considered by Italgroup. When the motor is running at high speed, a minimum pressure must exists at the motor ports (see boost pressure paragraph), but in all cases this pressure must not exceed the maximum working pressure reported in the zero displacement code motor technical data. To perform the boost circuit, an anticavitation valve (AC valve, referring to the diagram on the previous page) must be present, in order to avoid cavitation. Bearings A crankcase flushing flow is highly recommendend in freewheeling operation, to control and reduce the motor temperature rise during the freewheeling. If the motor running speed is between 1000 and 1500 rpm, a 15 l/min (indicative value) flushing flow is compulsory. The bearing life depends by different factors, like bearing type, motor speed, working pressure, external loads, duty cycle, fluid viscosity, oil cleanliness, type and temperature. Lifetime is measured by L 10 which is called theoretic lifetime. It represents the number of cycles that 90% of identical bearings can effort at the same load without showing wear and tear. Please refer to bearing lifetime diagrams reported in the following pages to obtain the theoretical bearing lifetime. The lifetimes diagrams shown the L 50, median or average lifetime, that can be considered as 5 times L 10. Please note that the theoretical lifetime can be different from the real lifetime, especially in case of heavy duty applications with continuous work cycle. Please contact Italgroup S.r.l. for more information. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 31

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE MOTOR INSTALLATION AND STARTUP Motor creep speed The hydraulic motor is able to hold the load acting as a brake (if proper valves or circuit are considered and installed), but a certain creep speed is always present: this is typical of all brands hydraulic motors. The motor creep speed depends by many factors, like operating conditions (motor displacement and type, pressure load on the shaft, oil viscosity, type and temperature) and are represented in the creep speed diagrams (see performance diagrams for each motor size). The creep speed diagrams are shown for an hydraulic oil at reference conditions of 40 cst. If creep speed is higher than desired value a negative brake can be considered: Italgroup can supply negative brakes that can be fitted to the hydraulic motor. Boost pressure Please contact Italgroup S.r.l. for more information. When the motor runs at a speed that can cause pumping effects, a positive pressure it is needed at the motor ports.the minimum required pressure at the motor ports can be estimated basing on different parameters, using the following formula: p = 1 + p C + C H n 2 V 2 Where p is the boost pressure, p C the case pressure, n the rotation speed, V the motor displacement, and C H is a constant, depending by the motor serie. Motor C H R8C H1 0,25 * 10-9 R8C H3 0,25 * 10-9 R8C H4 0,5 * 10-10 R8C H5 0,5 * 10-10 R8C H55 0,4 * 10-10 R8C H6 0,4 * 10-10 R8C H7 0,25 * 10-10 Example: We suppose (IAC H4 motor): n=400 [rpm], p C =3 [bar], V=800 [cm 3 ]; We can calculate the boost pressure as follows: p = 1 + 3 + 0,5 * 10-10 * 400 2 * 800 2 = 1 + 3 + 5,12 = 9,12 [bar] 32 R8C rev.00 - Oct. 2018

SPECIAL FEATURES Special features Marine painting If needed, special painting or primers are available in order to guarantee optimal protection against normal corrosion and marine environment corrosion. The ordering code is MP. Please contact Italgroup S.r.l. for more information. Speedy-sleeve A special inox sleeve is available upon request. In case the motor is used in aggressive medias or environments, this can be very useful in order to protect the motor shaft surface located in proximity of the motor shaft seal. This improves the shaft and seal endurance respect to wear and corrosion. The ordering code is SPSL. Please contact Italgroup S.r.l. for more information. High pressure shaft seal Standard R8C motors are supplied with high pressure shaft seals, the continuous drain pressure must be maximum 6 bar, whereas the peak drain pressure must be maximum 10 bar. In case the drain line can or must has a higher pressure, special shaft seals are available upon request. The ordering code is HPS. The drain pressure with HPS shaft seal can reach 20-25 bar continuous pressure and 30 bar peak pressure. The HPS shaft seal is bi-directional also, so it can be used for example in underwater applications. Please contact Italgroup S.r.l. for more information. Counterclockwise rotation Standard R8C motors are supplied with clockwise distributor timing. Please refer to the installation drawings of each section for more information. With ordering code CCW the motor is supplied with counterclockwise rotation timing. Contact Italgroup for more information. Standard timing CCW timing Oil inlet Oil outlet The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 33

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE TROUBLESHOOTING Problem Possible cause Solution Excessive noises Unit overheating Anomalous drainage flow Insufficient torque Insufficient speed Cavitation Mechanical vibrations Unstable motor displacement Irregular pressure or flow Air bubbles in the circuit Overflow Overpressure Oil viscosity too low Undersized cooling system Working without oil in the case Worn motor internal components Motor internal seals worn Excessive pressure in the motor case Pressure relief valve set incorrectly Undersized motor displacement Motor is in low displacement Pump not able to reach the design pressure Oversized motor displacement Motor is in high displacement Pump not able to reach the design flow Undersized pump Excessive drain flow Adopt an anti-cavitation system Check and fix damaged components Check the displacement change circuit Check other components (pump, valves, accumulators) and check drain flow Bleed circuit Check max allowed flow Check relief valve pressure setting Choose the appropriate oil according to the temperature Improve cooling system Overhaul the unit, fill with oil before start-up Overhaul the motor Overhaul the motor Check drain port size, pressure and flow, check piping connections Check relief valve pressure setting Replace with bigger displ. motor Check the displacement change circuit Check pump integrity Replace with smaller displ. motor Check the displacement change circuit Check pump integrity Improve pump output flow Overhaul the motor 34 R8C rev.00 - Oct. 2018

Problem Possible cause Solution Output shaft cannot rotate Oil leakage Incorrecte sense of rotation Seized motor flow distributor Motor internal seizure Motor internal seals worn Air in the circuit Undersized motor selection Insufficient inlet pressure Negative or positive brake is activate Worn seals Excessive pressure in the motor case Burst motor shaft seal Pipes incorrectly connected Incorrect rotating distributor timing Overhaul the flow distributor Overhaul the motor Check drain flow, overhaul the motor Bleed the circuit Replace with bigger size motor Check pump and circuit relief valves Deactivate the brake Replace seals Check drain port size, pressure and flow, check piping connections Check drain port size, pressure and flow, check piping connections Check pipe connections Change rotating distributor timing The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 35

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE UNIT CONVERSIONS LENGHT 1 m = 39,3701 in MASS 1 kg = 2,2046 lb POWER 1 kw = 1,341 HP = 3,2808 ft = 1,3596 CV = 1,0936 yd FORCE 1 N = 0,102 kgf 1 HP = 0,7457 kw = 1000 mm = 0,2248 lbf = 1,0139 CV 1 in = 0,0833 ft 1 kgf = 2,205 lbf = 25,4 mm = 9,806 N VOLUME 1 m 3 = 1000 l 1 ft = 0,3048 m 1 lbf = 0,4536 kgf 1 l = 61,023 in 3 = 0,3333 yd = 4,448 N = 0,264 galus = 12 in 1 in 3 = 0,01639 l 1 yd = 0,9144 m PRESSURE 1 bar = 14,223 psi = 16,39 cm 3 = 3 ft = 0,99 atm = 0,004326 galus = 36 in = 1,02 ata 1 galus = 3,7879 l 1 km = 1000 m = 100000 Pa =231,15 in 3 = 1093,6 yd = 100 kpa = 0,6214 mile = 0,1 MPa TORQUE 1 Nm = 0,102 kgm 1 mile = 1,609 km 1 psi = 0,0703 bar = 0,7376 lbf ft = 1760 yd 1 kgm = 9,806 Nm FLOW 1 l/min = 0,264 gpm = 7,2325 lbf ft SPEED 1 m/s = 3,6 km/h = 1000 cc/rev 1 lbf ft = 0,1383 kgm = 2,237 mph 1 gpm = 3,785 l/min = 1,3558 Nm = 3,2808 ft/s = 3785 cc/min 1 km/h = 0,2778 m/s 1 m 3 /s = 60000 l/min = 0,6214 mph = 15852 gpm = 0,9113 ft/s 1 mph = 1,609 km/h = 0,447 m/s = 1,467 ft/s 1 ft/s = 0,3048 m/s = 1,0973 km/h = 0,6818 mph 36 R8C rev.00 - Oct. 2018

R8C H1 TECHNICAL DATA Pag. 38 IAC 195-250 H1 - INSTALLATION DRAWING Pag. 39 IAC 195-250/S H1 - INSTALLATION DRAWING Pag. 40 IAC 195-250/BH H1 - INSTALLATION DRAWING Pag. 41 R8C H1 - NIP OPTION Pag. 42 R8C H1 - CETOP 3 FITTING Pag. 43 R8C 195 H1 - PERFORMANCE CURVES Pag. 44-46 R8C 250 H1 - PERFORMANCE CURVES Pag. 47-49 R8C H1 - ORDERING CODE Pag. 50 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 37

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H1 TECHNICAL DATA R8C 195 H1 Displacement (*) [cc] 195 175 150 125 100 95 75 69 Th. specific torque [Nm/bar] 3,1 2,8 2,4 2 1,6 1,5 1,2 1,1 Continuous speed [rpm] 850 850 1000 1000 1050 1050 1100 1100 Peak speed [rpm] 950 1050 1150 1150 1200 1200 1250 1250 Minimum speed [rpm] 3 3 3 4 4 4 5 5 Mechanical efficiency [%] 89,5 89,2 89 88,5 88 87,8 87 85,5 Starting efficiency [%] 84,5 84,2 84 83,5 83 82 80 77 Continuous power (**) [kw] 37 35 33 31 30 28 21 19 Cont. power with flushing [kw] 46 43 39 37 36 33 27 25 Continuous pressure [bar] 270 270 270 270 250 250 250 250 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 Flushing flow [l/min] 6 6 6 6 6 6 6 6 Dry weight [kg] 26 26 26 26 26 26 26 26 R8C 250 H1 Displacement (*) [cc] 257 232 195 175 150 125 100 95 Th. specific torque [Nm/bar] 4,1 3,7 3,1 2,8 2,4 2 1,6 1,5 Continuous speed [rpm] 810 810 850 850 1000 1000 1050 1050 Peak speed [rpm] 920 920 950 1050 1150 1150 1200 1200 Minimum speed [rpm] 3 3 3 3 3 4 4 5 Mechanical efficiency [%] 88,5 88,2 88 87,5 87 86,8 86 84,5 Starting efficiency [%] 83,5 83,2 83 82,5 82 81 79 76 Continuous power (**) [kw] 39 38 37 35 33 31 29 29 Cont. power with flushing [kw] 50 47 46 44 41 39 35 33 Continuous pressure [bar] 250 250 250 250 250 250 250 250 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 Flushing flow [l/min] 6 6 6 6 6 6 6 6 Dry weight [kg] 26 26 26 26 26 26 26 26 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 40 kw and starting efficiency is 90%, estimated required power is 40/0.9 = 44,44 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 38 R8C rev.00 - Oct. 2018

R8C 195-250 H1 XY DISPLACEMENT CHANGE CONFIGURATION N 2 PORTS 1" BSP 14 12 140 130 69 15 96 172-0,05-0,15 83 288 77 41 151 9 N 5 MTG HOLES 11 ON A 190 P.C.D. X - minimum displacement Y - maximum displacement 4 68 Ø190 DRAIN PORT 3/8" BSP X PORT 36 ANGLE BETWEEN X AND Y PORTS Y PORT 9 112,5 DRAIN PORT 3/8" BSP 4 A0 MOUNTING FACE 64 43 27 M12x20 28 UNI 221 UNI 8953-6x28x34 DIN ISO 14-6x28x34 A1 MOUNTING FACE 64 43 27 M12x20 W35x2x16-8e DIN 5480 Available spline billet: SB14 Available spline billet: SB32 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 39

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 195-250/S H1 XY DISPLACEMENT CHANGE CONFIGURATION N 2 PORTS 1" BSP 5 17,5 N 5 MTG HOLES 12,5 ON A 210 P.C.D. 140 130 3 DRAIN PORT 3/8" BSP X PORT 36 ANGLE BETWEEN X AND Y PORTS 130 69 175-0,05-0,15 210 235 83 288 77 41 168,5 X - minimum displacement Y - maximum displacement 4 68 Y PORT 9 DRAIN PORT 3/8" BSP 4 A0 MOUNTING FACE 46.5 43 27 M12x20 28 UNI 221 UNI 8953-6x28x34 DIN ISO 14-6x28x34 A1 MOUNTING FACE 46.5 43 27 M12x20 W35x2x16-8e DIN 5480 Available spline billet: SB14 Available spline billet: SB32 40 R8C rev.00 - Oct. 2018

R8C 195-250/BH H1 XY DISPLACEMENT CHANGE CONFIGURATION N 2 PORTS 1" BSP 14,5 4 N 5 MTG HOLES 10,5 ON A 210 P.C.D. 140 MOUNTING FACE 49.5 43 130 69 175-0,05-0,15 210 235 41 77 165,5 68 127 DRAIN PORT 3/8" BSP X PORT 36 ANGLE BETWEEN X AND Y PORTS 83 288 X - minimum displacement Y - maximum displacement 4 Y PORT 9 DRAIN PORT 3/8" BSP 4 A0 27 M12x20 28 UNI 221 UNI 8953-6x28x34 DIN ISO 14-6x28x34 MOUNTING FACE A1 49.5 43 27 M12x20 W35x2x16-8e DIN 5480 Available spline billet: SB14 Available spline billet: SB32 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 41

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H1 - NIP OPTION XY DISPLACEMENT CHANGE CONFIGURATION 62 (standard) 102 (NIP version) X PORT 36 ANGLE BETWEEN X AND Y PORTS Y PORT X - minimum displacement Y - maximum displacement 42 R8C rev.00 - Oct. 2018

R8C H1 - CETOP 3 FITTING CETOP 3 DISPLACEMENT CHANGE CONFIGURATION P X T CETOP 3 FITTING Y VIEW FROM Z X - minimum displacement Y - maximum displacement N 2 PORTS 1" SAE 3000 140 69 29 41 169 186.5 (/S VERSION) 183.5 (/BH VERSION) 246 263.5 (/S VERSION) 260.5 (/BH VERSION) 105 CETOP 3 SUPPLY PORT Z CETOP 3 SUPPLY PORT CETOP 3 DISPLACEMENT CHANGE VALVE C3-12 SV (12V DC) C3-24 SV (24V DC) C3 - HY SV (HYDRAULIC OPERATED) The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 43

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 195 H1 - PERFORMANCE CURVES 195 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 95 cc - WITHOUT FLUSHING 350 bar 310 bar 250 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 44 R8C rev.00 - Oct. 2018

R8C 195 H1 - PERFORMANCE CURVES 195 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 95 cc - WITH FLUSHING 350 bar 310 bar 250 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 45

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 195 H1 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 69 75 95 125 150 195 257 cc 40 35 30 25 20 15 10 creep speed [rpm] 5 0 0 1 2 3 external leakage [l/min] 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (257 cc): p=200 [bar], we obtain: external leakage 2,9 [l/min], shaft creep speed 13,5 [rpm]. If we suppose (257 cc): p=200 [bar] and n=300 [rpm] we obtain a volumetric efficiency of 96%; BEARING LIFE n=25 n=50 n=100 n=200 n=300 n=500 EX 2 EX 1 250 bar 180 bar 120 bar 60 bar L50h 100000 50000 20000 10000 5000 2000 1000 200000 3000 F r F r Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] 5 kn 10 kn 15 kn a=175 mm a=75 mm a=150 mm a=125 mm a=100 mm Shaft stress limit a=50 mm a 20 kn Reference viscosity: 40 cst Example: We suppose (EX1): p=180 [bar], n=100 [rpm]; we obtain an average lifetime of 20000 [h]. If we suppose (EX2): F r =5 [kn], a=125 [mm], p=250 [bar] and n=100 [rpm], we obtain an average lifetime of 4500 [h]. 46 R8C rev.00 - Oct. 2018

R8C 250 H1 - PERFORMANCE CURVES 257 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 125 cc - WITHOUT FLUSHING 350 bar 310 bar 250 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 47

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 250 H1 - PERFORMANCE CURVES 257 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 125 cc - WITH FLUSHING 350 bar 310 bar 250 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 48 R8C rev.00 - Oct. 2018

R8C 250 H1 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 69 75 95 125 150 195 257 cc 40 35 30 25 20 15 10 creep speed [rpm] 5 0 0 1 2 3 external leakage [l/min] 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (257 cc): p=200 [bar], we obtain: external leakage 3 [l/min], shaft creep speed 13,5 [rpm]. If we suppose (257 cc): p=200 [bar] and n=300 [rpm] we obtain a volumetric efficiency of 96%; BEARING LIFE n=25 n=50 n=100 n=200 n=300 n=500 EX 2 250 bar 180 bar 120 bar 60 bar EX 1 L50h 100000 50000 20000 10000 5000 2000 1000 200000 3000 F r F r 5 kn 10 kn a=175 mm a=150 mm a=125 mm a=100 mm Shaft stress limit Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] a 15 kn 20 kn a=75 mm Example: We suppose (EX1): p=60 [bar], n=500 [rpm]; we obtain an average lifetime of 55000 [h]. If we suppose (EX2): F r =5 [kn], a=100 [mm], p=180 [bar] and n=100 [rpm], we obtain an average lifetime of 7500 [h]. a=50 mm Reference viscosity: 40 cst The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 49

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H1 - ORDERING CODE R8C - - - - H1 - - - - - - - - - - - - - - DISPLACEMENT 195 250 INTERCHANGEABILITY /S /BH SERIE H1 SHAFT A0 A1 TACHOMETER TA TB TT1 TQ1 EST EST30 EST31 EST32 EST33 See pag. 128-132 SPECIAL FEATURES MP SPSL HPS CCW See pag. 33 NIP See pag. 33 Z - - Italgroup internal code DISTRIBUTOR D31B D31BJ D36B D36BJ D310B D310BJ D40 D40J D47 D47J D416 D416J See pag. 126-127 DISPLACEMENT CHANGE FITTING AND ACCESSORIES XY XY-SV C3-SV C3-12 SV C3-24 SV C3-HY SV C3-12 CSV SPLINED BILLET SPLINED BAR SB14 SB32 See pag. 133-135 MAXIMUM AND MINIMUM DISPLACEMENTS C3-24 CSV C3-HY CSV See pag. 24-32 EXAMPLES: R8C 195/S H1 A0 D40 (195-95) R8C 250 H1 A1 D47 C3-SV (257-125) R8C 195 H1 A0 D40 J CCW (195-75) 50 R8C rev.00 - Oct. 2018

R8C H3 TECHNICAL DATA Pag. 52 R8C 500 H3 - INSTALLATION DRAWING Pag. 53 R8C 500/B30 H3 - INSTALLATION DRAWING Pag. 54 R8C 500/C H3 - INSTALLATION DRAWING Pag. 55 R8C 500/MRH H3 - INSTALLATION DRAWING Pag. 56 R8C H3 - NIP OPTION Pag. 57 R8C H3 - CETOP 3 FITTING Pag. 58 R8C 500 H3 - PERFORMANCE CURVES Pag. 59-61 R8C H3 - ORDERING CODE Pag. 62 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 51

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H3 TECHNICAL DATA R8C 500 H3 Displacement (*) [cc] 492 442 393 344 292 Th. specific torque [Nm/bar] 7,8 7 6,3 5,5 4,7 Continuous speed [rpm] 500 550 600 630 630 Peak speed [rpm] 600 650 680 700 700 Minimum speed [rpm] 2 2 2 2 2 Mechanical efficiency [%] 87,5 86 85 83,6 82,4 Starting efficiency [%] 82,5 81 80 77,2 74,3 Continuous power (**) [kw] 67 67 67 62 52 Cont. power with flushing [kw] 80 80 80 72 62 Continuous pressure [bar] 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 Flushing flow [l/min] 8 8 8 8 8 Dry weight [kg] 68 68 68 68 68 Displacement (*) [cc] 255 197 147 98 Th. specific torque [Nm/bar] 4,1 3,1 2,3 1,6 Continuous speed [rpm] 650 700 700 700 Peak speed [rpm] 750 800 900 1000 Minimum speed [rpm] 3 3 3 4 Mechanical efficiency [%] 82 80 78 73,4 Starting efficiency [%] 69,6 62,1 52 30 Continuous power (**) [kw] 49 39 25 16 Cont. power with flushing [kw] 56 42 29 19 Continuous pressure [bar] 270 250 250 250 Intermittent pressure [bar] 310 310 310 310 Peak pressure [bar] 350 350 350 350 Flushing flow [l/min] 8 8 8 8 Dry weight [kg] 68 68 68 68 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 40 kw and starting efficiency is 90%, estimated required power is 40/0.9 = 44,44 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 52 R8C rev.00 - Oct. 2018

R8C 500 H3 XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Y PORT 144,25 8,5 X - minimum displacement Y - maximum displacement N 2 PORTS 1" BSP 19 14 Ø254 190 DRAIN PORT 1/2" BSP Ø140 69 24 Ø150 Ø230-0,05-0,15 95 77 41 210 10 N 5 Ø15 ON A Ø254 P.C.D. DRAIN PORT 1/2" BSP 68 36 ANGLE BETWEEN X-Y PORTS A0 90 63 43 M14x28 36 UNI 221 UNI 8953-8x36x42 DIN ISO 14-8x36x42 A3 26 N40x3x12-9H DIN 5480 60 Z Available spline billet: SB3 Available splined bar: B8076 6 39 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 53

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 500/B30 H3 XY DISPLACEMENT CHANGE CONFIGURATION Y PORT VIEW FROM Z X PORT 144,25 8,5 X - minimum displacement Y - maximum displacement N 2 PORTS 1" BSP 19 Ø260 190 DRAIN PORT 1/2" BSP Ø140 69 24 Ø122 Ø180-0,05-0,15 95 77 41 210 11 N 5 Ø18 ON A Ø260 P.C.D. DRAIN PORT 1/2" BSP 68 36 ANGLE BETWEEN X-Y PORTS 130 100 71 A1 A11 A2 1/2"-20 UNF 2B ASA SPLINE BS 3550-1963 Z=17, PITCH 8/16 130 100 71 1/2"-20 UNF 2B W55x3x17-8e DIN 5480 130 100 90 Z 14 58.3 1/2"-20 UNF 2B 55 +0,011-0,019 32 32 32 54 Available spline billet: SB21 Available spline billet: SB30 R8C rev.00 - Oct. 2018

R8C 500/C H3 XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Y PORT 156,25 8,5 Available distributor flange: FL2 Refer to page 136-137 (distributor fitting D47) X - minimum displacement Y - maximum displacement N 2 PORTS 1" BSP 12 Ø266 190 DRAIN PORT 1/2" BSP Ø140 69 36 Ø190-0,05-0,15 Ø285 95 77 41 222 12 N 5 Ø13 ON A Ø266 P.C.D. DRAIN PORT 1/2" BSP 68 36 ANGLE BETWEEN X-Y PORTS Z A0 A11 97 74 56 97 74 56 M12x25 46 UNI 221 M12x25 UNI 8953-8x46x54 DIN ISO 14-8x46x54 46 UNI 221 UNI 8953-8x46x54 DIN ISO 14-8x46x54 97 74 56 97 74 56 M12x25 W55x3x17-8e M12x25 DIN 5480 W55x3x17-8e DIN 5480 Available spline billet: SB5 Available spline billet: SB30 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 55

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 500/MRH H3 XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Y PORT 144,25 8,5 X - minimum displacement Y - maximum displacement N 2 PORTS 1" BSP 20 Ø260 190 DRAIN PORT 1/2" BSP Ø140 69 24 Ø224-0,05-0,15 95 77 41 210 N 5 Ø19 ON A Ø260 P.C.D. DRAIN PORT 1/2" BSP 68 36 ANGLE BETWEEN X-Y PORTS N 2 3/8"-24 UNF 2B DEPTH 20 A1 28 130 100 71 1/2"-20 UNF 2B ASA SPLINE BS 3550-1963 Z=17, PITCH 8/16 Z 32 Available spline billet: SB30 56 R8C rev.00 - Oct. 2018

R8C H3 - NIP OPTION XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Y PORT 73 (standard) 113 (NIP version) X - minimum displacement Y - maximum displacement 36 ANGLE BETWEEN X-Y PORTS Z The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 57

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H3 - CETOP 3 FITTING CETOP 3 DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z P X Y T CETOP 3 FITTING X - minimum displacement Y - maximum displacement N 2 ports 1" SAE 3000 Ø140 69 CETOP 3 SUPPLY PORT 29 105 41 210 222 (/C VERSION) 287 299 (/C VERSION) CETOP 3 SUPPLY PORT 65 Z CETOP 3 DISPLACEMENT CHANGE VALVE C3-12 SV (12V DC) C3-24 SV (24V DC) C3 - HY SV (HYDRAULIC OPERATED) 58 R8C rev.00 - Oct. 2018

R8C H3 - PERFORMANCE CURVES 492 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 255 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 59

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H3 - PERFORMANCE CURVES 492 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 255 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 60 R8C rev.00 - Oct. 2018

R8C H3 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 100 200 300 600 30 147 197 255 292 393 492 cc 25 20 15 10 5 creep speed [rpm] 50 25 10 rpm 0 0 1 2 3 4 external leakage [l/min] 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (393 cc): p=200 [bar], we obtain: external leakage 3,3 [l/min], shaft creep speed 11.5 [rpm]. If we suppose (393 cc): p=200 [bar] and n=300 [rpm] we obtain a volumetric efficiency of 97%; BEARING LIFE n=50 n=100 EX 2 EX 1 n=200 n=400 n=600 120 bar 60 bar 250 bar 180 bar L50h 5 4 3 200000 9 8 7 6 5 4 3 2 10 4 10 5 5000 a=150 mm a=100 mm a=75 mm F r F r 10 kn Shaft stress limit Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] 20 kn 30 kn a=50 mm a 35 kn Reference viscosity: 40 cst Example: We suppose (EX1): p=120 [bar], n=400 [rpm]; we obtain an average lifetime of 53000 [h]. If we suppose (EX2): F r =9 [kn], a=75 [mm], p=180 [bar] and n=100 [rpm], we obtain an average lifetime of 42000 [h]. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 61

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H3 - ORDERING CODE R8C - - - - H3 - - - - - - - - - - - - - - DISPLACEMENT 500 INTERCHANGEABILITY /S /BH /MRH SERIE H3 SHAFT A0 A1 A11 A2 A3 TACHOMETER TA TB TT1 TQ1 EST EST30 EST31 EST32 EST33 See pag. 128-132 SPECIAL FEATURES MP SPSL HPS CCW See pag. 33 NIP See pag. 33 Z - - Italgroup internal code DISTRIBUTOR D31B D31BJ D36B D36BJ D310B D310BJ D40 D40J D47 D47J D416 D416J See pag. 126-127 DISPLACEMENT CHANGE FITTING AND ACCESSORIES XY XY-SV C3-SV C3-12 SV C3-24 SV C3-HY SV C3-12 CSV C3-24 CSV SPLINED BILLET SPLINED BAR SB3 SB21 B8076 SB5 SB30 See pag. 133-135 MAXIMUM AND MINIMUM DISPLACEMENTS C3-HY CSV See pag. 24-32 EXAMPLES: R8C 500/B30 H3 A1 D47 (492-255) R8C 500/MRH H3 A1 D40 CCW (492-292) R8C 500/C H3 A0 D47 FL2 EST31 (492-255) 62 R8C rev.00 - Oct. 2018

R8C H4 TECHNICAL DATA Pag. 64 R8C 800 H4 - INSTALLATION DRAWING Pag. 65 R8C 800/B45 H4 - INSTALLATION DRAWING Pag. 66 R8C 800/C H4 - INSTALLATION DRAWING Pag. 67 R8C 800/MRH H4 - INSTALLATION DRAWING Pag. 68 R8C H4 - NIP OPTION Pag. 69 R8C H4 - CETOP 3 FITTING Pag. 70 R8C 800 H4 - PERFORMANCE CURVES Pag. 71-73 R8C H4 - ORDERING CODE Pag. 74 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 63

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H4 TECHNICAL DATA R8C 800 H4 Displacement (*) [cc] 792 660 575 493 410 Th. specific torque [Nm/bar] 12,6 10,5 9,2 7,8 6,5 Continuous speed [rpm] 450 550 620 650 650 Peak speed [rpm] 550 700 720 750 800 Minimum speed [rpm] 2 2 2 2 2 Mechanical efficiency [%] 90,8 90,4 88,5 88 87,4 Starting efficiency [%] 84,8 84,4 82,6 79 75 Continuous power (**) [kw] 108 94 84 72 55 Cont. power with flushing [kw] 128 112 100 86 66 Continuous pressure [bar] 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 Flushing flow [l/min] 10 10 10 10 10 Dry weight [kg] 92 92 92 92 92 Displacement (*) [cc] 328 273 245 165 Th. specific torque [Nm/bar] 5,2 4,3 3,9 2,6 Continuous speed [rpm] 700 700 700 700 Peak speed [rpm] 800 850 850 900 Minimum speed [rpm] 2 2 3 3 Mechanical efficiency [%] 84,5 82,4 82 60,2 Starting efficiency [%] 70,2 68,3 60,8 43,3 Continuous power (**) [kw] 55 43 41 19 Cont. power with flushing [kw] 66 51 49 25 Continuous pressure [bar] 250 250 250 250 Intermittent pressure [bar] 310 310 310 310 Peak pressure [bar] 350 350 350 350 Flushing flow [l/min] 10 10 10 10 Dry weight [kg] 92 92 92 92 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 40 kw and starting efficiency is 90%, estimated required power is 40/0.9 = 44,44 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 64 R8C rev.00 - Oct. 2018

XY DISPLACEMENT CHANGE CONFIGURATION 158,25 8,5 Y PORT Y PORT VIEW FROM Z X PORT R8C 800 H4 VIEW FROM Z X PORT 158,25 8,5 16 28 Ø452 224 X - minimum displacement Y - maximum DRAIN PORT displacement 1/2" BSP N 2 PORTS 1" BSP 16 28 Ø300 Ø452 224 DRAIN PORT 1/2" BSP Ø140 69 N 2 PORTS 1" BSP 26 Ø160 Ø256-0,05-0,15 114 Ø300 Ø140 69 77 41 77 41 A3 26 224 14 224 14 Ø160 Ø256-0,05-0,15 N 5 Ø16.5 ON A Ø300 P.C.D. DRAIN PORT 1/2" BSP 114 N 5 Ø16.5 ON A Ø300 P.C.D. DRAIN PORT 1/2" BSP 68 36 ANGLE BETWEEN X-Y PORTS 68 36 ANGLE ZBETWEEN X-Y PORTS 44 53X58 DIN 5482 75 Z 10 40 44 53X58 DIN 5482 75 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 65 10 40

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 800/B45 H4 XY DISPLACEMENT CHANGE CONFIGURATION 158,25 158,25 8,5 8,5 Y PORT Y PORT VIEW FROM Z X PORT VIEW FROM Z X PORT 158,25 8,5 N 2 PORTS 1" BSP 12 12 36 36 Ø452 Ø452 Ø452 224 224 X - minimum displacement Y - maximum DRAIN displacement PORT 1/2" BSP DRAIN PORT 1/2" BSP N 2 PORTS 1" BSP Ø140 Ø140 69 69 41 77 41 77 A1 133 100 224 133 71 100 224 71 26 26 M16 M16 ASA SPLINE ASA SPLINE BS 3550-1963 BS 3550-1963 Z=17, PITCH 8/16 Z=17, PITCH 8/16 Ø180 Ø180 Ø225,4-0,05-0,15 Ø225,4-0,05-0,15 114 114 N 5 N 5 ON ON A A Ø18 Ø18 ON ON A A Ø305 Ø305 P.C.D. P.C.D. DRAIN PORT 1/2" BSP N 5 ON A Ø18 ON A Ø305 P.C.D. DRAIN PORT 1/2" BSP 58.3 58.3 A2 133 100 133 90 68 100 90 30 30 36 68 ANGLE BETWEEN X-Y PORTS 36 ANGLE BETWEEN X-Y PORTS Z 14 14 M16 M16 Z 55 +0,011 55 +0,011-0,019-0,019 66 Available spline 30billet: SB21 30 R8C rev.00 - Oct. 2018

Y PORT Y PORT XY DISPLACEMENT CHANGE CONFIGURATION 174,25 8,5 174,25 8,5 VIEW FROM VIEW Z FROM Z Y PORT X PORT X PORT R8C 800/C H4 VIEW FROM Z X PORT PORTS 1" BSP Available distributor flange: Refer 16to page 136-137 16 (distributor fitting D47) FL2 16 174,25 8,5 Ø290 Ø452 224 Ø290 Ø452 224 DRAIN PORT 1/2" BSP Ø452 224 DRAIN PORT 1/2" BSP X - minimum displacement Y - maximum displacement DRAIN PORT 1/2" BSP Ø140 69 42 N 2 PORTS 1" BSP 42 Ø220-0,05-0,15 Ø324 Ø220-0,05-0,15 114 Ø324 114 Ø290 41 101 84 Ø140 41 77 240 69 M16x30 101 52 UNI 221 77 84 A0 240 41 UNI 8953-8x52x60 DIN ISO 14-8x52x60 15 M16x30 101 84 240 42 15 52 UNI 221 UNI 8953-8x52x60 DIN ISO 14-8x52x60 Available spline billet: M16x30 SB16 N 5 Ø13 ON A Ø290 P.C.D. 52 UNI 221 UNI 8953-8x52x60 DIN ISO 14-8x52x60 15 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. Ø220-0,05-0,15 Ø324 N 5 Ø13 ON A Ø290 P.C.D. DRAIN PORT DRAIN PORT 1/2" BSP 1/2" BSP 9 A3 28 40 114 N 5 Ø13 ON A Ø290 P.C.D. N55x3x17-9H DIN 5480 75 9 68 DRAIN PORT 1/2" BSP 28 40 36 N55x3x17-9H DIN 5480 9 75 28 40 68 36 ANGLE BETWEEN ANGLE BETWEEN X-Y PORTS X-Y PORTS Z 9 A31 28 N55x3x17-9H DIN 5480 40 75 68 Z 36 ANGLE BETWEEN X-Y PORTS 50x45 DIN 5482 75 Z 67

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 800/MRH H4 XY DISPLACEMENT CHANGE CONFIGURATION 158,25 8,5 Y PORT Y PORT VIEW FROM Z X PORT VIEW FROM Z X PORT 158,25 8,5 36 N 2 PORTS 1" BSP 12 36 12 Ø452 Ø452 224 224 X - minimum displacement DRAIN PORT Y - maximum displacement 1/2" BSP DRAIN PORT 1/2" BSP N 2 PORTS 1" BSP Ø140 Ø140 69 69 41 77 41 77 26 26 224 224 Ø180 Ø180 Ø225,4-0,05-0,15 Ø225,4-0,05-0,15 114 114 N 5 ON A Ø18 ON A Ø305 P.C.D. DRAIN PORT 1/2" BSP N 5 ON A Ø18 ON A Ø305 P.C.D. DRAIN PORT 1/2" BSP 68 68 36 36 ANGLE BETWEEN X-Y PORTS ANGLE BETWEEN X-Y PORTS Z A1 Z N 2 3/8"-24 UNF 2B DEPTH 20 N 2 3/8"-24 UNF 2B DEPTH 20 32 32 141 103 71 141 103 71 ASA SPLINE BS 3550-1963 ASA SPLINE Z=20, PITCH BS 8/16 3550-1963 Z=20, PITCH 8/16 Available spline billet: SB21 68 R8C rev.00 - Oct. 2018

R8C H4 - NIP OPTION XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Y PORT X - minimum displacement Y - maximum displacement 16 28 73 (standard) 113 (NIP version) 36 ANGLE BETWEEN X-Y PORTS Z The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 69

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H4 - CETOP 3 FITTING CETOP 3 DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z P X Y T CETOP 3 FITTING X - minimum displacement Y - maximum displacement N 2 PORTS 1" SAE 3000 Ø140 69 CETOP 3 SUPPLY PORT 29 105 41 224 240 (/C VERSION) 301 317 (/C VERSION) CETOP 3 SUPPLY PORT 65 Z 70 CETOP 3 DISPLACEMENT CHANGE VALVE C3-12 SV (12V DC) C3-24 SV (24V DC) C3 - HY SV (HYDRAULIC OPERATED) R8C rev.00 - Oct. 2018

R8C H4 - PERFORMANCE CURVES 792 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 410 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 71

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H4 - PERFORMANCE CURVES 792 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 410 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 72 R8C rev.00 - Oct. 2018

R8C H4 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 20 50 100 200 300 600 328 410 493 660 792 cc 15 10 5 creep speed [rpm] 25 10 rpm 0 0 1 2 3 4 5 external leakage [l/min] 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (660 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 8 [rpm]. If we suppose (660 cc): p=200 [bar] and n=300 [rpm] we obtain a volumetric efficiency of 97%; BEARING LIFE n=25 n=50 n=100 n=200 n=400 n=600 EX 2 EX 1 250 bar 120 bar 60 bar 180 bar L50h 200000 300000 100000 50000 20000 30000 10000 5000 3000 2000 1000 10 kn a=200 mm a=150 mm F r F r 20 kn a=100 mm Shaft stress limit Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] a 30 kn 40 kn a=50 mm Reference viscosity: 40 cst Example: We suppose (EX1): p=180 [bar], n=100 [rpm]; we obtain an average lifetime of 33000 [h]. If we suppose (EX2): F r =10 [kn], a=150 [mm] and p=180 [bar] we obtain an average lifetime of 18000 [h]. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 73

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H4 - ORDERING CODE R8C - - - - H4 - - - - - - - - - - - - - - DISPLACEMENT 800 INTERCHANGEABILITY /B45 /C /MRH SERIE H4 SHAFT A0 A1 A2 A3 A31 TACHOMETER TA TB TT1 TQ1 EST EST30 EST31 EST32 EST33 See pag. 128-132 SPECIAL FEATURES MP SPSL HPS CCW See pag. 33 NIP See pag. 33 Z - - Italgroup internal code DISTRIBUTOR D31B D31BJ D36B D36BJ D310B D310BJ D40 D40J D47 D47J D416 D416J D75 D75J D90 D90J See pag. 126-127 DISPLACEMENT CHANGE FITTING AND ACCESSORIES XY XY-SV C3-SV C3-12 SV C3-24 SV C3-HY SV C3-12 CSV C3-24 CSV C3-HY CSV See pag. 24-32 SPLINED BILLET SPLINED BAR SB16 SB21 See pag. 133-135 MAXIMUM AND MINIMUM DISPLACEMENTS EXAMPLES: R8C 800 H4 A3 D40 (792-492) R8C 800/C H4 A0 D47 J C3-SV (660-328) R8C 800/MRH H4 A1 D47 SB21 (792-245) 74 R8C rev.00 - Oct. 2018

R8C H5 TECHNICAL DATA Pag. 76 R8C 1400 H5 - INSTALLATION DRAWING Pag. 77 R8C 1400/C H5 - INSTALLATION DRAWING Pag. 78 R8C 1400/MRH H5 - INSTALLATION DRAWING Pag. 79 R8C 1400/BD5 H5 - INSTALLATION DRAWING Pag. 80 R8C H5 - NIP OPTION Pag. 81 R8C H5 - CETOP 3 FITTING Pag. 82 R8C 1400 H5 - PERFORMANCE CURVES Pag. 83-85 R8C H5 - ORDERING CODE Pag. 86 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 75

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H5 TECHNICAL DATA R8C 1400 H5 Displacement (*) [cc] 1600 1499 1393 1313 1235 1150 1070 980 900 820 Th. specific torque [Nm/bar] 24,5 23,9 22,2 20,9 19,7 18,3 17 15,6 14,3 13 Continuous speed [rpm] 370 400 410 435 440 460 480 490 495 520 Peak speed [rpm] 450 500 500 500 550 550 575 600 600 600 Minimum speed [rpm] 1 1 1 1 1 1 1 1 1 2 Mechanical efficiency [%] 94,2 94 93,9 93,7 93,5 93,4 93,2 93 92,6 92,3 Starting efficiency [%] 88,2 88 86,5 85,3 85,1 82,6 81,3 79,8 77,9 76 Continuous power (***) [kw] 145 142 137 132 132 127 122 116 111 106 Cont. power with flushing [kw] 174 172 167 157 157 152 147 139 133 127 Continuous pressure [bar] 270 270 270 270 270 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 350 350 Flushing flow [l/min] 12 12 12 12 12 12 12 12 12 12 Dry weight [kg] 173 173 173 173 173 173 173 173 173 173 Displacement (*) [cc] 737 655 574 492 410 328 246 164 82 0 Th. specific torque [Nm/bar] 11,7 10,4 9,1 7,8 6,5 5,2 3,9 2,6 1,3 0 Continuous speed [rpm] 545 600 600 600 600 600 600 600 1000 1000 Peak speed [rpm] 650 700 700 700 800 800 800 800 1200 1500 Minimum speed [rpm] 2 2 2 2 2 3 3 3 - - Mechanical efficiency [%] 91 89,3 87 83 81,7 75,5 65,7 60,5 0 0 Starting efficiency [%] 72,9 83,2 65 59,2 51 39 18 0 0 0 Continuous power (***) [kw] 106 106 96 71 56 41 26 19 0 0 Cont. power with flushing [kw] 127 127 111 91 76 56 36 23 0 0 Continuous pressure [bar] 250 250 250 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 12 12 12 12 12 12 12 12 15 15 Dry weight [kg] 173 173 173 173 173 173 173 173 173 173 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 120 kw and starting efficiency is 88,2%, estimated required power is 120/0.882 = 136 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 76 R8C rev.00 - Oct. 2018

XY DISPLACEMENT CHANGE CONFIGURATION Available distributor flanges: FL5 For S03 and S04, refer to page 136-137 (distributor fitting D75) FL6 186,25 10,5 Y PORT R8C 1400 H5 VIEW FROM Z X PORT X - minimum displacement Y - maximum displacement N 2 PORTS 1"1/2 SAE 3000 40,5 19 263 DRAIN PORT 1/2" BSP Ø39 69,85 Ø327 133 Ø170 92 72 35,71 A0 83 N 4+4 M12 133 92 55 107 255 72 62 UNI 221 M16x35 UNI 8953-8x62x72 62 UNI 221 DIN ISO 14-8x62x72 M16x35 UNI 8953-8x62x72 30 1/2"-20 65 UNF-2B 16 Ø230 Ø301.6-0,05-0,15 146 N 5 Ø20,5 ON A Ø327 P.C.D. DRAIN PORT 1/2" BSP Available spline 132 132billet: SB6 Available 132 132spline billet: SB7 72 72 72 72 30 55 55 30 65 65 30 39 132 132 132 132 72 132 132 72 72 72 55 72 72 65 55 55 65 65 39 39 M16x35 1/2"-20 UNF-2B 62 UNI 221 133 92 UNI 8953-8x62x72 DIN ISO 14-8x62x72 72 W70x3x22-8e DIN 5480 M16x35 1/2"-20 UNF-2B 1/2"-20 UNF-2B W70x3x22-8e 1/2"-20 DIN UNF-2B 5480 DIN ISO 14-8x62x72 62 UNI 221 UNI 8953-8x62x72 DIN ISO 14-8x62x72 132 62 UNI 221 UNI 8953-8x62x72 DIN ISO 14-8x62x72 1/2"-20 UNF-2B 72 W70x3x22-8e DIN 18 65 5480 1/2"-20 UNF-2B 132 60 +0,01-0,01 65 18 18 1/2"-20 UNF-2B 1/2"-20 UNF-2B 60 +0,01-0,01 18 30 30 30 30 55 72 55 ASA SPLINE BS 3550-1963 Z=14, PITCH 6/12 30 1/2"-20 UNF-2B 1/2"-20 UNF-2B Z=14, PITCH 1/2"-20 6/12 UNF-2B Z=14, PITCH 6/12 ASA SPLINE BS 3550-1963 60 +0,01-0,01 8 18 1/2"-20 80 UNF-2B N65x3x20-9H DIN 5480 50 8 92 30 ANGLE BETWEEN X-Y PORTS N65x3x20-9H DIN 5480 A11 39 A2 A3 133 92 72 W70x3x22-8e DIN 5480 133 92 72 W70x3x22-8e DIN 5480 M16x35 A1 132 72 55 132 72 55 ASA SPLINE BS 3550-1963 30 132 1/2"-20 UNF-2B ASA SPLINE BS 3550-1963 Z=14, PITCH 6/12 72 55 60 +0,01-0,01 1/2"-20 UNF-2B ASA SPLINE BS 3550-1963 Z=14, PITCH 6/12 N65x3x20-9H DIN 5480 60 +0,01-0,01 50 80 N65x3x20-9H 80 DIN 5480 Z 80 39 Ø545 N65x3x20-9H DIN 5480 80 65 65 30 30 30 30 30 30 8 50 8 50 8 50 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 77

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 1400/C H5 XY DISPLACEMENT CHANGE CONFIGURATION Available distributor flange: Refer to page 136-137 (distributor fitting D75) FL4 202,25 10,5 Y port Y port 202,25 10,5 VIEW FROM Z VIEW FROM Z X port X port X - minimum displacement Y - maximum displacement N 2 PORTS N 2 1"1/2 PORTS SAE 3000 1"1/2 SAE 3000 16 16 Ø545 Ø545 263 263 DRAIN PORT DRAIN 1/2" PORT BSP 1/2" BSP Ø39 Ø39 69,85 69,85 Ø170 35,71 Ø170 83 35,71 N 4+4 M12 A0 83 N 4+4 M12 117 92 72 46 55 55 107 271 107 271 117 92 72 M16x35 46 62 UNI 221 UNI M16x35 8953-8x62x72 DIN ISO 14-8x62x72 16 62 UNI 221 UNI 8953-8x62x72 DIN ISO 14-8x62x72 16 Ø250-0,05-0,15 Ø360 Ø250-0,05-0,15 146 Ø360 Ø330 146 Ø330 DRAIN PORT DRAIN PORT 1/2" BSP 1/2" BSP N 5 Ø15 ON A Ø330 N 5 Ø15 P.C.D. ON A Ø330 P.C.D. A3 37 N65x3x20-9H DIN 5480 37 92 30 ANGLE BETWEEN ANGLE BETWEEN X-Y PORTS X-Y PORTS 80 N65x3x20-9H DIN 5480 92 80 30 Z Z Available spline billet: SB6 8 8 50 50 78 R8C rev.00 - Oct. 2018

R8C 1400/MRH H5 XY DISPLACEMENT CHANGE CONFIGURATION X - minimum displacement Y - maximum displacement 186,25 10,5 N 2 PORTS 1"1/2 SAE 3000 N 2 PORTS 1"1/2 SAE 3000 69,85 Ø39 186,25 10,5 Y port Y port VIEW FROM Z VIEW FROM Z X port X port 40,5 19 40,5 19 Ø545 Ø545 263 263 DRAIN PORT 1/2" BSP DRAIN PORT 1/2" BSP Ø39 69,85 Ø327 Ø170 35,71 Ø170 35,71 83 N 4+4 M12 83 N 4+4 M12 N 2 1/2"-20 UNF 2B DEPTH 20 50.8 55 55 107 255 107 255 A1 30 30 132 72 55 30 MTG FACE 1/2"-20 UNF-2B 16 16 ASA SPLINE BS 3550-1963 Z=14, PITCH 6/12 Ø301.6-0,05-0,15 Ø230 Ø230 Ø301.6-0,05-0,15 146 146 Ø327 N 5 Ø20,5 ON A Ø327 P.C.D. N 5 Ø20,5 ON A Ø327 P.C.D. DRAIN PORT DRAIN 1/2" BSPPORT 1/2" BSP 92 92 30 30 ANGLE BETWEEN X-Y PORTS ANGLE BETWEEN X-Y PORTS Z Z Available spline billet: SB7 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 79

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 1400/BD5 H5 XY DISPLACEMENT CHANGE CONFIGURATION 228,25 10,5 Y PORT Y PORT VIEW FROM Z X PORT VIEW FROM Z X PORT N 2 PORTS 1"1/2 SAE 6000 N 2 PORTS 1"1/2 SAE 6000 X - minimum displacement Y - maximum displacement Ø40 79,4 79,4 42 42 8 8 228,25 10,5 N 5 MTG HOLES 20 EQUISPACED ON A 310 P.C.D. N 5 MTG HOLES 20 EQUISPACED ON A 310 P.C.D. 263 263 DRAIN PORT 1/2" BSP DRAIN PORT 1/2" BSP 190 36,7 Ø40 100 190 36,7 100 N 4+4 M16 N 4+4 M16 59 113 59 113 297 297 6 6 Ø265-0,05-0,15 Ø265-0,05-0,15 Ø310 Ø310 Ø372 Ø372 146 146 DRAIN PORT 1/2" BSP DRAIN PORT 1/2" BSP 95 30 95 ANGLE BETWEEN X-Y PORTS 30 Ø545 Ø545 ANGLE BETWEEN Z X-Y PORTS Z A3 37 37 N55x3x17-9H N55x3x17-9H DIN 5480 DIN 5480 80 80 10 43 80 10 43 R8C rev.00 - Oct. 2018

R8C H5 - NIP OPTION XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Y PORT X - minimum displacement Y - maximum displacement 83 (standard version) 123 (NIP version) 30 ANGLE BETWEEN X-Y PORTS Z The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 81

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H5 - CETOP 3 FITTING CETOP 3 DISPLACEMENT CHANGE CONFIGURATION CETOP 3 SUPPLY PORT P X Y T 9 107 N 2 PORTS 1"1/2 SAE 6000 100 190 CETOP 3 FITTING CETOP 3 SUPPLY PORT 59 259 272 (/C VERSION) 372 388 (/C VERSION) 95 X - minimum displacement Y - maximum displacement CETOP 3 DISPLACEMENT CHANGE VALVE C3-12 SV (12V DC) C3-24 SV (24V DC) C3 - HY SV (HYDRAULIC OPERATED) 82 R8C rev.00 - Oct. 2018

R8C H5 - PERFORMANCE CURVES 1600 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 820 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 83

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H5 - PERFORMANCE CURVES 1600 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 820 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 84 R8C rev.00 - Oct. 2018

R8C H5 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 15 50 100 300 410 492 655 980 10 5 creep speed [rpm] 25 10 rpm 200 600 1536 cc 0 1 2 3 4 5 external leakage [l/min] 0 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (980 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 5,5 [rpm]. If we suppose (980 cc): p=200 [bar] and n=100 [rpm] we obtain a volumetric efficiency of 94,5%; BEARING LIFE n=25 n=50 n=100 n=200 n=300 n=450 n=600 EX 2 EX 1 250 bar 180 bar 120 bar 60 bar L50h 100000 50000 20000 30000 10000 5000 3000 2000 1000 10 kn a=200 mm a=150 mm F r F r 20 kn 30 kn a=100 mm Shaft stress limit Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] a 40 kn 50 kn 60 kn a=50 mm Reference viscosity: 40 cst Example: We suppose (EX1): p=180 [bar], n=100 [rpm]; we obtain an average lifetime of 40000 [h]. If we suppose (EX2): F r =15 [kn], a=150 [mm], n=200 [rpm] and p=180 [bar] we obtain an average lifetime of 11000 [h]. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 85

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H5 - ORDERING CODE R8C - - - - H5 - - - - - - - - - - - - - - DISPLACEMENT 1400 INTERCHANGEABILITY /C /MRH /BD5 SERIE H5 SHAFT A0 A1 A11 A12 A2 A31 TACHOMETER TA TB TT1 TQ1 EST EST30 EST31 EST32 EST33 See pag. 128-132 SPECIAL FEATURES MP SPSL HPS CCW See pag. 33 NIP See pag. 33 Z - - Italgroup internal code DISTRIBUTOR D31B D31BJ D36B D36BJ D310B D310BJ D40 D40J D47 D47J D416 D416J D75 D75J D90 D90J See pag. 126-127 DISPLACEMENT CHANGE FITTING AND ACCESSORIES XY XY-SV C3-SV C3-12 SV C3-24 SV C3-HY SV C3-12 CSV C3-24 CSV C3-HY CSV See pag. 24-32 SPLINED BILLET SPLINED BAR SB6 SB7 See pag. 133-135 MAXIMUM AND MINIMUM DISPLACEMENTS EXAMPLES: R8C 1400 H5 A1 D75 SB7 (1499-737) R8C 1400/C H5 A0 D75 FL4 (1600-820) R8C 1400/BD5 H5 A3 D90 CCW C3-SV (1070-492) 86 R8C rev.00 - Oct. 2018

R8C H55 TECHNICAL DATA Pag. 88 R8C 2200 H55 - INSTALLATION DRAWING Pag. 89 R8C 2200/MRH H55 - INSTALLATION DRAWING Pag. 90 R8C H55 - NIP OPTION Pag. 91 R8C H55 - CETOP 3 FITTING Pag. 92 R8C 2200 H55 - PERFORMANCE CURVES Pag. 93-95 R8C H55 - ORDERING CODE Pag. 96 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 87

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H55 TECHNICAL DATA R8C 2200 H55 Displacement (*) [cc] 2200 2049 1970 1800 1640 1470 1310 1150 Th. specific torque [Nm/bar] 35 32,6 31,3 28,6 26,1 23,4 20,9 18,3 Continuous speed [rpm] 280 305 320 350 380 410 440 470 Peak speed [rpm] 320 340 360 400 430 470 500 540 Minimum speed [rpm] 1 1 1 1 1 1 1 1 Mechanical efficiency [%] 92,2 92,2 92,2 92,2 91 90 88 86,5 Starting efficiency [%] 81 80,6 79,6 77,5 74,6 71,5 67,5 62,2 Continuous power (***) [kw] 140 140 135 125 116 108 100 90 Cont. power with flushing [kw] 170 170 165 155 145 135 127 110 Continuous pressure [bar] 270 270 270 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 Flushing flow [l/min] 10 10 10 10 10 10 10 10 Dry weight [kg] 210 210 210 210 210 210 210 210 Displacement (*) [cc] 980 820 655 490 330 160 82 0 Th. specific torque [Nm/bar] 15,6 13,1 10,4 7,8 5,3 2,5 1,3 0 Continuous speed [rpm] 610 620 620 640 640 640 1000 1000 Peak speed [rpm] 700 700 720 720 800 800 1200 1500 Minimum speed [rpm] 1 2 2 2 3 5 - - Mechanical efficiency [%] 82,2 81,8 78,2 76 73 26 0 0 Starting efficiency [%] 55,3 45,8 31,5 0 0 0 0 0 Continuous power (***) [kw] 83 75 65 50 25 5 0 0 Cont. power with flushing [kw] 105 90 80 65 40 10 0 0 Continuous pressure [bar] 270 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 10 10 10 10 10 12 15 15 Dry weight [kg] 210 210 210 210 210 210 210 210 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 150 kw and starting efficiency is 86%, estimated required power is 150/0.86 = 174,4 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 88 R8C rev.00 - Oct. 2018

XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z R8C 2200 H55 X PORT Available distributor flange: FL7 For S04, refer to page 136-137 (distributor fitting D90) 229 10,5 Y PORT X - minimum displacement Y - maximum displacement N 2 PORTS 1"1/2 SAE 6000 Ø40 79,4 34 24 285 DRAIN PORT 3/4" BSP Z=20, PITCH 6/12 Ø190 A0 153 120 36,7 100 N 4+4 M16 97 35 91 M20 59 113 296 82 UNI 221 UNI 8953-10x82x92 DIN ISO 14-10x82x92 M20 3/4"-16 UNF-2B 35 W85x3x27-8e 91 DIN 5480 30 82 UNI 221 M20 UNI 8953-10x82x92 DIN ISO 14-10x82x92 82 UNI 221 M20 UNI MTG 8953 FACE - 10x82x92 DIN ISO 14-10x82x92 35 24 3/4"-16 UNF-2B 85 +0,011-0,009 35 24 23 143 97 76 35 3/4"-16 UNF-2B 24 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. Ø248 3/4"-16 UNF-2B 85 +0,011-0,009 Ø381-0,05-0,15 Ø148 Ø419,1 N 5 Ø20,5 ON A Ø419,1 P.C.D. ASA SPLINE BS 3550-1963 Z=20, PITCH 6/12 3/4"-16 UNF-2B 143 97 76 35 3/4"-16 UNF-2B 74 +0,5-0,7 DRAIN PORT 3/4" BSP ASA SPLINE 3/4"-16 BS UNF-2B 3550-1963 Z=20, PITCH 6/12 3/4"-16 UNF-2B Available spline billet: SB9 35 Available spline billet: 35 SB10 143 143 143 97 97 90 90 97 A11 A2 143 A4 90 97 143 90 97 76 35 153 153 120 120 97 153 97 120 35 91 97 91 82 UNI 221 UNI 8953-10x82x92 DIN ISO 14-10x82x92 35 A1 3/4"-16 UNF-2B 24 130 85,3 22,22 143 9,525 +0,05 0 97 76 Z=20, PITCH 6/12 35 85,3 95 95 30 ANGLE BETWEEN X AND Y PORTS 3/4"-16 UNF-2B MTG W85x3x27-8e FACE DIN 5480 143 97 76 KEY SUPPLIED: 22.22 WIDE x 15.9 THICK 35 TAPER 1:10 TAPER M30x60 1:10 M30x60-0,7 HEX HEAD SCREW 185 74 +0,5 TAPER 1:10-0,7 12 185 12 185 TAPER 12 1:10 74 +0,5 130 85,3 22,22 9,525 +0,05 0 Z 3/4"-16 UNF-2B 95 W85x3x27-8e 3/4"-16 DIN UNF-2B 5480 KEY SUPPLIED: 22.22 WIDE KEY SUPPLIED: x 15.9 THICK 22.22 WIDE x 15.9 THICK KEY SUPPLIED: 22.22 WIDE x 15.9 THICK HEX HEAD M30x60 SCREW HEX HEAD SCREW 89 E 35 85 +0,011-0,009 143 97 143 76 97 76 85 +0,011-0,009 35 ASA SPLINE BS 3550-1963 Z=20, PITCH 6/12 ASA SPLINE BS 3550-1963 74 +0,5-0,7 130 22,22 130 85,3 143 97 76 143 97 76 9,525 +0,05 22,22 0 185 12 35 9,525 +0,05 0 95 35 W85x3x27-8e 3/4"-16 DIN UNF-2B 5480 95 W85x3x27-8e DIN 5480 M30x60 HEX HEAD SCREW,22 5

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 2200/MRH H55 XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Y PORT X - minimum displacement Y - maximum displacement 229 10,5 N 2 PORTS 1"1/2 SAE 6000 Ø40 79,4 34 24 285 DRAIN PORT 3/4" BSP Ø190 36,7 100 30 Ø248 Ø381-0,05-0,15 Ø148 N 4+4 M16 59 113 296 23 Ø419,1 N 5 Ø20,5 ON A Ø419,1 P.C.D. DRAIN PORT 3/4" BSP 95 30 ANGLE BETWEEN X AND Y PORTS Z A1 A4 N 2 1/2"-20 UNF 2B N 2 DEPTH 1/2"-20 24 UNF 2B DEPTH 24 130 130 100 100 76 76 ASA SPLINE BS 3550-1963 ASA SPLINE Z=23, BS PITCH 3550-1963 6/12 Z=23, PITCH 6/12 130 130 8 +0,05 8 +0,05 0 0 24 24 1 3/4" - 5 UNC 1 3/4" - 5 UNC 50.8 50.8 Available spline billet: SB10 37,4 +0,5 37,4 +0,5-0,7-0,7 95 95 TAPER 1:10 TAPER 1:10 183 70 183251 70 251 105 105 90 R8C rev.00 - Oct. 2018

R8C H55 - NIP OPTION XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Y PORT X - minimum displacement Y - maximum displacement 93 (standard version) 133 (NIP version) 30 ANGLE BETWEEN X AND Y PORTS Z The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 91

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H55 - CETOP 3 FITTING CETOP 3 DISPLACEMENT CHANGE CONFIGURATION CETOP 3 SUPPLY PORT P X Y T 9 118 N 2 PORTS 1"1/2 SAE 6000 Ø190 100 CETOP 3 FITTING CETOP 3 SUPPLY PORT 59 113 301 95 X - minimum displacement Y - maximum displacement CETOP 3 DISPLACEMENT CHANGE VALVE C3-12 SV (12V DC) C3-24 SV (24V DC) C3 - HY SV (HYDRAULIC OPERATED) 92 R8C rev.00 - Oct. 2018

R8C H55 - PERFORMANCE CURVES 2200 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 1150 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 93

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H55 - PERFORMANCE CURVES 2200 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 1150 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 94 R8C rev.00 - Oct. 2018

R8C H55 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 820 7 25 50 100 200 2200 1150 980 1310 1640 6 5 4 3 2 1 creep speed [rpm] 10 rpm 0 0 1 2 3 4 5 external leakage [l/min] 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (2200 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 2 [rpm]. If we suppose (2200 cc): p=200 [bar] and n=50 [rpm] we obtain a volumetric efficiency of 96%; BEARING LIFE n=25 n=50 n=100 n=175 n=300 n=450 EX 2 n=600 EX 1 120 bar 180 bar 250 bar 60 bar L50h 100000 50000 20000 10000 5000 2000 1000 30000 3000 F r Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] F r 20 kn 40 kn 60 kn a=200 mm a=150 mm a=100 mm Shaft stress limit a=50 mm a 80 kn Reference viscosity: 40 cst Example: We suppose (EX1): p=120 [bar], n=300 [rpm]; we obtain an average lifetime of 34000 [h]. If we suppose (EX2): F r =20 [kn], a=100 [mm], n=50 [rpm] and p=250 [bar] we obtain an average lifetime of 12000 [h]. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 95

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H55 - ORDERING CODE R8C - - - - H55 - - - - - - - - - - - - - - DISPLACEMENT 2200 INTERCHANGEABILITY /MRH SERIE H55 SHAFT A0 A1 A11 A2 A4 TACHOMETER TA TB TT1 TQ1 EST EST30 EST31 EST32 EST33 See pag. 128-132 SPECIAL FEATURES MP SPSL HPS CCW See pag. 33 NIP See pag. 33 Z - - Italgroup internal code DISTRIBUTOR D31B D31BJ D36B D36BJ D310B D310BJ D40 D40J D47 D47J D416 D416J D75 D75J D90 D90J See pag. 126-127 DISPLACEMENT CHANGE FITTING AND ACCESSORIES XY XY-SV C3-SV C3-12 SV C3-24 SV C3-HY SV C3-12 CSV C3-24 CSV C3-HY CSV See pag. 24-32 SPLINED BILLET SPLINED BAR SB9 SB10 See pag. 133-135 MAXIMUM AND MINIMUM DISPLACEMENTS EXAMPLES: R8C 2200 H55 A1 D90 SB10 (2200-1150) R8C 2200 H55 A1 D90 C3-24 SV (2049-820) R8C 2200/MRH H55 A4 D90 C3-SV (2049-0) 96 R8C rev.00 - Oct. 2018

R8C H6 TECHNICAL DATA Pag. 98 R8C 3000 H6 - INSTALLATION DRAWING Pag. 99 R8C 3000/C H6 - INSTALLATION DRAWING Pag. 100 R8C 3000/MRH H6 - INSTALLATION DRAWING Pag. 101 R8C 3000/GM6 H6 - INSTALLATION DRAWING Pag. 102 R8C 3000/MR1400 H6 - INSTALLATION DRAWING Pag. 103 R8C H6 - NIP OPTION Pag. 104 R8C H6 - CETOP 3 FITTING Pag. 105 R8C 3000 H6 - PERFORMANCE CURVES Pag. 106-108 R8C H6 - ORDERING CODE Pag. 109 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 97

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H6 TECHNICAL DATA R8C 3000 H6 Displacement (*) [cc] 3085 2950 2790 2620 2460 2290 2130 1970 1800 1640 Th. specific torque [Nm/bar] 49,1 47 44,4 41,7 39,2 36,5 33,9 31,4 28,7 26,1 Continuous speed [rpm] 235 240 245 250 250 265 285 305 340 370 Peak speed [rpm] 280 280 300 300 300 320 340 350 400 420 Minimum speed [rpm] 1 1 1 1 1 1 1 1 1 1 Mechanical efficiency [%] 95 94,5 94,2 94 93,7 93,5 92,8 92,3 92 91 Starting efficiency [%] 86 85,4 84,4 83,6 82,4 82 80,2 78 76 73 Continuous power (***) [kw] 182 182 182 170 160 155 145 133 123 116 Cont. power with flushing [kw] 272 272 272 255 240 230 214 197 186 176 Continuous pressure [bar] 270 270 270 270 270 270 270 270 270 270 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 350 350 Flushing flow [l/min] 12 12 12 12 12 12 12 12 12 12 Dry weight [kg] 308 308 308 308 308 308 308 308 308 308 Displacement (*) [cc] 1470 1310 1150 980 820 670 490 330 160 82 0 Th. specific torque [Nm/bar] 23,4 20,9 18,3 15,6 13,1 10,7 7,8 5,2 2,5 1,3 0 Continuous speed [rpm] 400 425 455 490 520 600 600 600 600 1000 1000 Peak speed [rpm] 450 475 500 540 580 700 700 800 800 1200 1500 Minimum speed [rpm] 1 1 1 1 2 2 2 3 5 - - Mechanical efficiency [%] 90,5 88 86,2 82,3 81,7 78 76 73,2 25 0 0 Starting efficiency [%] 70 66,4 62 55,4 46,3 33 0 0 0 0 0 Continuous power (***) [kw] 107 100 100 100 90 80 70 40 8 0 0 Cont. power with flushing [kw] 161 150 150 150 135 96 90 60 11 0 0 Continuous pressure [bar] 270 250 250 250 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 12 12 12 12 12 12 12 12 12 15 15 Dry weight [kg] 308 308 308 308 308 308 308 308 308 308 308 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 120 kw and starting efficiency is 88,2%, estimated required power is 120/0.882 = 136 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 98 R8C rev.00 - Oct. 2018

XY DISPLACEMENT CHANGE CONFIGURATION Available distributor flange: FL7 For S04, refer to page 136-137 (distributor fitting D90) VIEW FROM Z R8C 3000 H6 X - minimum displacement Y - maximum displacement 34 24 237,75 10,5 Y PORT X PORT 328 DRAIN PORT 3/4" BSP N 2 PORTS 1"1/2 SAE 6000 Ø40 79,4 Ø667 Ø190 36,7 100 N 4+4 M16 153 120 153 97 120 35 M20 59 35 113 306 82 UNI 82 221 UNI 221 UNI 8953 UNI - 8953 10x82x92-10x82x92 DIN ISO DIN 14 ISO - 10x82x92 14-10x82x92 23 133 97 133 76 97 76 35 Ø248 Ø381-0,05-0,15 174 Ø419,1 N 5 Ø20,5 ON A Ø419,1 P.C.D. 3/4"-16 3/4"-16 UNF-2B UNF-2B ASA SPLINE ASA SPLINE BS 3550-1963 BS 3550-1963 Z=20, Z=20, PITCH PITCH 6/12 6/12 DRAIN PORT 3/4" BSP A0 A1 A11 97 M20 133 97 76 133 97 76 35 95 30 ANGLE BETWEEN X AND Y PORTS 3/4"-16 3/4"-16 UNF-2B UNF-2B W85x3x27-8e W85x3x27-8e DIN 5480 DIN 5480 Z Available spline billet: 35 SB9 Available spline 35 billet: SB10 130 166 A12 A2 A21 133 97 134 97 13090 166 130 133 76 97 134 97 90 130 76 35 3/4"-16 3/4"-16 UNF-2B UNF-2B ASA SPLINE BS 3550-1963 Z=16, PITCH 5/10 ASA SPLINE BS 3550-1963 Z=16, PITCH 5/10 91 91 35 24 24 3/4"-16 3/4"-16 UNF-2B UNF-2B 85 +0,011-0,009 85 +0,011-0,009 91 91 35 35 24 24 3/4"-16 3/4"-16 UNF-2B UNF-2B 85 +0,011 85 +0,011-0,009-0,009 35 35 35 Available spline billet: SB27 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 99

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 3000/C H6 XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT Available distributor flange: Refer to page 136-137 (distributor fitting D75) FL10 237,75 10,5 Y PORT X - minimum displacement Y - maximum displacement 34 328 DRAIN PORT 3/4" BSP N 2 PORTS 1"1/2 SAE 6000 Ø40 79,4 Ø667 Ø190 36,7 100 35 Ø248 Ø335-0,05-0,15 174 N 4+4 M16 59 113 306 23 Ø440 N 5 Ø19 ON A Ø440 P.C.D.. DRAIN PORT 3/4" BSP 95 30 ANGLE BETWEEN X AND Y PORTS Z A0 153 120 97 M20 82 UNI 221 UNI 8953-10x82x92 DIN ISO 14-10x82x92 35 Available spline billet: SB9 100 R8C rev.00 - Oct. 2018

XY DISPLACEMENT CHANGE CONFIGURATION X - minimum displacement Y - maximum displacement 237,75 10,5 R8C 3000/MRH H6 Y PORT VIEW FROM Z X PORT 34 24 328 DRAIN PORT 3/4" BSP N 2 PORTS 1"1/2 SAE 6000 Ø190 Ø40 N 2 PORTS 1"1/2 SAE 6000 Ø190 Ø40 36,7 36,7 100 100 N 4+4 M16 N 4+4 M16 79,4 79,4 35 35 59 11359 306 113 306 34 24 23 237,75 10,5 Y PORT VIEW FROM Z X PORT 23 Ø248 Ø248 Ø381-0,05-0,15 Ø667 Ø381-0,05 174-0,15 Ø667 174 N 5 Ø20,5 ON A Ø419,1 P.C.D. DRAIN PORT DRAIN PORT 3/4" BSP 3/4" BSP N 5 Ø20,5 ON A Ø419,1 P.C.D. 328 Ø419,1 Ø419,1 95 30 DRAIN PORT 3/4" BSP 95 30 ANGLE BETWEEN X ANGLE BETWEEN AND Y XPORTS AND Y PORTS Z Z A0 A13 133 97 76 3/4"-16 UNF-2B ASA SPLINE BS 3550-1963 Z=20, PITCH 6/12 N 2 1/2"-20 UNF 2B DEPTH 24 130 100 76 ASA SPLINE BS 3550-1963 Z=23, PITCH 6/12 35 50.8 Available spline billet: SB10 Available spline billet: SB24 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 101

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 3000/GM6 H6 VIEW FROM Z XY DISPLACEMENT CHANGE CONFIGURATION Y PORT VIEW FROM Z X PORT X - minimum displacement Y - maximum displacement N 2 PORTS 1"1/2 SAE 6000 Ø190 36,7 Ø40 100 N 4+4 M16 79,4 113 356 59 113 356 50 30 287,75 10,5 Y PORT X PORT N 2 PORTS 1"1/2 SAE 6000 Ø190 36,7 Ø40 100 N 4+4 M16 79,4 59 50 30 287,75 10,5 15 15 N 5 MTG HOLES 20.5 EQUISPACED ON A 419,1 P.C.D. N 5 MTG HOLES 20.5 EQUISPACED ON A 419,1 P.C.D. Ø381-0,05 Ø381-0,05-0,15-0,15 Ø419,1 Ø419,1 Ø462 Ø462 174 174 DRAIN PORT 3/4" BSP DRAIN PORT 3/4" BSP 328 328 95 30 DRAIN PORT 3/4" BSP 95 ANGLE BETWEEN X AND Y PORTS 30 DRAIN PORT 3/4" BSP ANGLE BETWEEN X AND Y PORTS Z Ø667 Ø667 A32 Z 20 20 N80x3x25-9H N80x3x25-9H DIN 5480 DIN 5480 105 105 8 68 8 68 102 R8C rev.00 - Oct. 2018

R8C 3000/MR1400 H6 XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z X PORT 292,75 10,5 Y PORT X - minimum displacement Y - maximum displacement N 2 PORTS 1"1/2 SAE 6000 Ø40 79,4 55 15 N 5 MTG HOLES 15 EQUISPACED ON A 330 P.C.D. 328 DRAIN PORT 3/4" BSP Ø190 36,7 100 Ø250-0,05-0,15 Ø330 Ø480 174 N 4+4 M16 59 113 361 10 DRAIN PORT 3/4" BSP 95 30 ANGLE BETWEEN X AND Y PORTS Ø667 Z A0 117 92 72 M16x35 62 UNI 221 UNI 8953-8x62x72 DIN ISO 14-8x62x72 Available spline billet: SB6 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 103

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H6 - NIP OPTION XY DISPLACEMENT CHANGE CONFIGURATION Y PORT VIEW FROM Z X PORT X - minimum displacement Y - maximum displacement 93 (standard version) 133 (NIP version) 30 ANGLE BETWEEN X AND Y PORTS Z 104 R8C rev.00 - Oct. 2018

CETOP 3 DISPLACEMENT CHANGE CONFIGURATION R8C H6 - CETOP 3 FITTING P X T 9 CETOP 3 SUPPLY PORT Y 118 N 2 PORTS 1"1/2 SAE 6000 190 100 CETOP 3 FITTING CETOP 3 SUPPLY PORT 59 310 95 423 X - minimum displacement Y - maximum displacement CETOP 3 DISPLACEMENT CHANGE VALVE C3-12 SV (12V DC) C3-24 SV (24V DC) C3 - HY SV (HYDRAULIC OPERATED) The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 105

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H6 - PERFORMANCE CURVES 3085 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 1470 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 106 R8C rev.00 - Oct. 2018

R8C H6 - PERFORMANCE CURVES 3085 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 1470 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 107

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H6 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 980 1470 1800 2290 3085 cc 7 6 5 4 3 2 1 creep speed [rpm] 10 rpm 25 50 100 200 0 0 1 2 3 4 5 external leakage [l/min] 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (2290 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 2,2 [rpm]. If we suppose (2290 cc): p=200 [bar] and n=50 [rpm] we obtain a volumetric efficiency of 96%; BEARING LIFE n=25 n=50 n=100 n=175 n=300 n=450 EX 2 n=600 EX 1 120 bar 180 bar 250 bar 60 bar L50h 100000 50000 20000 10000 5000 2000 1000 30000 3000 F r Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] F r 20 kn 40 kn 60 kn a=200 mm a=150 mm a=100 mm Shaft stress limit a=50 mm a 80 kn Reference viscosity: 40 cst Example: We suppose (EX1): p=120 [bar], n=300 [rpm]; we obtain an average lifetime of 34000 [h]. If we suppose (EX2): F r =20 [kn], a=100 [mm], n=50 [rpm] and p=250 [bar] we obtain an average lifetime of 12000 [h]. 108 R8C rev.00 - Oct. 2018

R8C H6 - ORDERING CODE R8C - - - - H6 - - - - - - - - - - - - - - DISPLACEMENT 3000 INTERCHANGEABILITY /MRH /GM6 /MR1400 SERIE H6 SHAFT A0 A1 A11 A12 A13 A2 A21 A32 TACHOMETER TA TB TT1 TQ1 EST EST30 EST31 EST32 EST33 See pag. 128-132 SPECIAL FEATURES MP SPSL HPS CCW See pag. 33 NIP See pag. 33 Z - - Italgroup internal code DISTRIBUTOR D31B D31BJ D36B D36BJ D310B D310BJ D40 D40J D47 D47J D416 D416J D75 D75J D90 D90J See pag. 126-127 DISPLACEMENT CHANGE FITTING AND ACCESSORIES XY XY-SV C3-SV C3-12 SV C3-24 SV C3-HY SV C3-12 CSV C3-24 CSV C3-HY CSV See pag. 24-32 SPLINED BILLET SPLINED BAR SB6 SB10 SB27 SB9 SB24 See pag. 133-135 MAXIMUM AND MINIMUM DISPLACEMENTS EXAMPLES: R8C 3000 H6 A1 D90 (3085-1470) R8C 3000/C H6 A0 D90J C3-12 SV (2620-980) R8C 3000/GM6 H6 A32 D90 CCW (2620-0) The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 109

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE 110 R8C rev.00 - Oct. 2018

R8C H7 TECHNICAL DATA Pag. 112-113 R8C 4600-5400 H7 - INSTALLATION DRAWING Pag. 114 R8C 4600-5400/MRH H7 - INSTALLATION DRAWING Pag. 115 R8C H7 - NIP OPTION Pag. 116 R8C H7 - CETOP 3 FITTING Pag. 117 R8C 4600 H7 - PERFORMANCE CURVES Pag. 118-120 R8C 4600 H7 - PERFORMANCE CURVES Pag. 121-123 R8C H7 - ORDERING CODE Pag. 124 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 111

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H7 TECHNICAL DATA R8C 4600 H7 Displacement (*) [cc] 4617 4177 3650 3280 2950 2620 2290 1970 Th. specific torque [Nm/bar] 73,5 66,5 58,1 52,2 47 41,7 36,5 31,4 Continuous speed [rpm] 150 158 168 175 210 235 275 305 Peak speed [rpm] 170 185 210 230 255 280 330 380 Minimum speed [rpm] 1 1 1 1 1 1 1 1 Mechanical efficiency [%] 95,3 95,1 94,5 94,4 93,3 92,4 91,5 90,1 Starting efficiency [%] 85,1 84 83,3 82,5 81,2 80,1 78 75,2 Continuous power (***) [kw] 197 192 177 157 147 136 120 110 Cont. power with flushing [kw] 292 272 252 237 216 200 180 165 Continuous pressure [bar] 270 270 270 270 270 270 270 250 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 Flushing flow [l/min] 12 12 12 12 12 12 12 12 Dry weight [kg] 405 405 405 405 405 405 405 405 Displacement (*) [cc] 1640 1310 980 655 492 328 164 82 0 Th. specific torque [Nm/bar] 26,1 20,9 15,6 10,4 7,8 5,2 2,6 0 0 Continuous speed [rpm] 380 435 460 495 520 550 600 1000 1000 Peak speed [rpm] 470 530 550 600 600 650 700 1200 1500 Minimum speed [rpm] 1 1 1 2 2 3 6 - - Mechanical efficiency [%] 86,5 83 78,4 76,2 66 46,4 25 0 0 Starting efficiency [%] 72,4 67,2 58 41 23,7 0 0 0 0 Continuous power (***) [kw] 110 95 75 50 45 25 10 0 0 Cont. power with flushing [kw] 165 140 112 80 65 32 10 0 0 Continuous pressure [bar] 250 250 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 12 12 12 12 12 12 12 15 15 Dry weight [kg] 405 405 405 405 405 405 405 405 405 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 160 kw and starting efficiency is 85,1%, estimated required power is 160/0.851 = 188 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. 112 R8C rev.00 - Oct. 2018

R8C H7 TECHNICAL DATA R8C 5400 H7 Displacement (*) [cc] 5326 5080 4915 4588 4097 3650 3280 2950 2620 Th. specific torque [Nm/bar] 84,8 80,9 78,2 73 65,2 58,1 52,2 47 41,7 Continuous speed [rpm] 130 135 140 150 160 170 190 215 230 Peak speed [rpm] 145 150 155 165 185 210 235 260 290 Minimum speed [rpm] 1 1 1 1 1 1 1 1 1 Mechanical efficiency [%] 95,2 95 95 95 95 94,4 94,3 93,2 92 Starting efficiency [%] 86 85,8 85,8 85,4 85,2 83 82,2 82 79,8 Continuous power (***) [kw] 197 197 197 192 180 165 155 145 135 Cont. power with flushing [kw] 265 262 262 256 245 230 230 215 200 Continuous pressure [bar] 250 250 250 250 250 250 250 250 250 Intermittent pressure [bar] 310 310 310 310 310 310 310 310 310 Peak pressure [bar] 350 350 350 350 350 350 350 350 350 Flushing flow [l/min] 12 12 12 12 12 12 12 12 12 Dry weight [kg] 405 405 405 405 405 405 405 405 405 Displacement (*) [cc] 2295 1640 1311 980 655 492 328 164 0 Th. specific torque [Nm/bar] 36,5 26,1 20,9 15,6 10,4 7,8 5,2 1,6 0 Continuous speed [rpm] 280 375 445 470 500 520 550 1000 1000 Peak speed [rpm] 335 450 530 550 600 600 650 1200 1500 Minimum speed [rpm] 1 1 1 1 2 2 3 - - Mechanical efficiency [%] 91,5 86 82,3 78,3 76,2 66,2 46,5 0 0 Starting efficiency [%] 77,7 72,1 67 58 41 24 0 0 0 Continuous power (***) [kw] 125 125 95 95 60 40 28 0 0 Cont. power with flushing [kw] 185 185 135 135 80 60 32 0 0 Continuous pressure [bar] 250 250 250 250 250 250 250 17(**) 17(**) Intermittent pressure [bar] 310 310 310 310 310 310 310 17(**) 17(**) Peak pressure [bar] 350 350 350 350 350 350 350 17(**) 17(**) Flushing flow [l/min] 12 12 12 12 12 12 12 15 15 Dry weight [kg] 405 405 405 405 405 405 405 405 405 (*) Different displacements can be available on request. Please contact Italgroup S.r.l. for more information. (**) Pressure limits at 1000 rpm. For lower speeds the values can be increased. Contact Italgroup for more information. (***) The continuous power and the continuous power with flushing are the output maximum power. To estimate the input power divide the output power by the mechanical efficiency. For example: if required output power is 160 kw and starting efficiency is 86%, estimated required power is 160/0.86 = 186 kw. Hydrostatic pressure test: 420 bar. Temperature range: -30 / 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 113

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 4600-5400 H7 XY DISPLACEMENT CHANGE CONFIGURATION VIEW VIEW FROM FROM Z Z VIEW FROM Z Y PORT Y PORTAvailable distributor flange: FL16 1/4" 1/4" Y BSP PORT BSP For S04, refer to page 136-137 (distributor fitting D90) N 2 PORTS N 2 1"1/2 PORTS N 2 SAE PORTS 6000 1"1/2 SAE 1"1/2 6000SAE 6000 79,4 X - minimum displacement Y - maximum displacement Ø190 36,7 139 Ø40 100 Ø190 Ø190 36,7 36,7 100 100 N 4+4 M16 N 4+4 M16 N 4+4 M16 100 76 A1 Ø40 Ø40 59 113 139 139 100 100 76 76 3/4"-16 UNF-2B 79,4 79,4 59 59 113 113 35 328 32 25 328 328 ASA 3/4"-16 3/4"-16 SPLINE UNF-2B UNF-2B BS 3550-1963 Z=20, PITCH 6/12 ASA ASA SPLINE BS BS 3550-1963 35 35 Z=20, PITCH 6/12 6/12 32 25 32 25 20 MTG FACE 20 20 248 A11 76-0,15 457,15 248 248-0,05 Z Ø520,7 DRAIN PORT DRAIN 3/4" PORT BSP DRAIN PORT 3/4" BSP 3/4" BSP N 7 Ø20 ON A Ø520,7 P.C.D. 139 139 139 100 100 100 76 76 3/4"-16 UNF-2B -0,15 457,15-0,05 457,15-0,05-0,15 X PORT X PORT X 1/4" PORT BSP Z Z Ø520,7 Ø520,7 N 7 Ø20 ON A Ø520,7 P.C.D. N 7 Ø20 ON A Ø520,7 P.C.D. 3/4"-16 UNF-2B W90x4x21-8e DIN 5480 W90x4x21-8e W90x4x21-8e DIN DIN 5480 5480 Ø748 Ø748 Ø748 367 A12 367 95 95 95 139 139 100 139 100 76 100 76 76 367 DRAIN PORT DRAIN PORT 3/4" DRAIN 3/4" BSP BSPPORT 3/4" BSP 3/4"-16 UNF-2B 3/4"-16 UNF-2B 3/4"-16 UNF-2B 178 178 178 ASA SPLINE ASA SPLINE BS 3550-1963 BS ASA 3550-1963 SPLINE Z=16, Z=16, PITCH BS 3550-1963 PITCH 5/10 5/10 Z=16, PITCH 5/10 114 91 Available spline billet: 36 91 91 188.5 149 140 35 36 36 188.5 149 140 24 3/4"-16 UNF-2B 35 35 24 24 3/4"-16 UNF-2B 85 +0,011-0,009 SB10 85 +0,011-0,009 10 55 10 10 67 ASA SPLINE BS 3550-1963 55 67 67 36 Z=20, PITCH ASA 6/12 SPLINE BS 3550-1963 130 Z=20, PITCH 6/12 36 130 10 10 10 MTG MTG FACE FACE 51 75 Available spline 36 billet: A2 A3 A31 A4 N75x3x24-9H DIN 5480 N75x3x24-9H N75x3x24-9H 105 DIN 5480 DIN 5480 105 105 51 51 75 75 58,6 58,6 0-1,6 0 58,6 0-1,6 36 36-1,6 146,5 146,5 146,5 133 99,4 99,4 99,4 SB27 133 10,5 10,5 183 183 67 67 250 250 TAPER 1:10 R8C rev.00 - Oct. 2018 183 67 250 133 10,5 25,4 25,4 TAPER TAPER 1:10 1:10 1"1/2-12 UNF 1"1/2-12 2A UNF 2A 1"1/2-12 UNF 2A 25,4 95.5 95.5 95.5

R8C 4600-5400/MRH H7 XY DISPLACEMENT CHANGE CONFIGURATION VIEW FROM Z VIEW FROM Z Y PORT Y PORT X - minimum displacement Y - maximum displacement 32 32 25 25 X PORT X PORT 367 DRAIN PORT DRAIN 3/4" PORTBSP 3/4" BSP 367 178 178 N 2 N 2 PORTS PORTS 1"1/2 1"1/2 SAE SAE 6000 6000 79,4 79,4 Z Z Ø40 Ø40 35 Ø190 Ø190 36,7 100 36,7 100 N 4+4 N 4+4 M16 M16 59 59 113 113 328 328 MTG FACE 20 20 248 248 457,15-0,05 457,15-0,05-0,15-0,15 Ø520,7 Ø520,7 N 7 Ø20 ON A Ø520,7 P.C.D. DRAIN PORT DRAIN 3/4" BSP PORT 3/4" BSP N 7 Ø20 ON A Ø520,7 P.C.D. Ø748 Ø748 95 95 A1 A13 139 100 76 3/4"-16 UNF-2B ASA SPLINE BS 3550-1963 Z=20, PITCH 6/12 N 2 1/2"-20 UNF 2B DEPTH 24 139 100 76 ASA SPLINE BS 3550-1963 Z=23, PITCH 6/12 35 50.8 Available spline billet: SB10 Available spline billet: SB24 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 115

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H7 - NIP OPTION XY DISPLACEMENT CHANGE CONFIGURATION ANGLE BETWEEN X-Y PORT DRAIN PORT 3/4" BSP VIEW FROM Z 259,25 10,5 Z 46 Y PORT X PORT DRAIN PORT 3/4" BSP X - minimum displacement Y - maximum displacement ANGLE BETWEEN X-Y PORT DRAIN PORT 3/4" BSP VIEW FROM Z Z 46 93 (standard version) 133 (NIP version) Y PORT DRAIN PORT 3/4" BSP X PORT 116 R8C rev.00 - Oct. 2018

CETOP 3 DISPLACEMENT CHANGE CONFIGURATION R8C H7 - CETOP 3 FITTING P X T 118 CETOP 3 SUPPLY PORT Y N 2 PORTS 1"1/2 SAE 6000 190 100 CETOP 3 FITTING CETOP 3 SUPPLY PORT 59 445 332 95 9 X - minimum displacement Y - maximum displacement CETOP 3 DISPLACEMENT CHANGE VALVE C3-12 SV (12V DC) C3-24 SV (24V DC) C3 - HY SV (HYDRAULIC OPERATED) The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 117

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 4600 H7 - PERFORMANCE CURVES 4617 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 2290 cc - WITHOUT FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 118 R8C rev.00 - Oct. 2018

R8C 4600 H7 - PERFORMANCE CURVES 4617 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar 2290 cc - WITH FLUSHING 350 bar 310 bar 270 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 119

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 4600 H7 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 1310 5 10 rpm 25 50 100 200 3650 4617 cc 1640 2290 4 3 2 1 creep speed [rpm] 0 0 1 2 3 4 5 external leakage [l/min] 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (3650 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 1,5 [rpm]. If we suppose (3650 cc): p=200 [bar] and n=50 [rpm] we obtain a volumetric efficiency of 97,5%; BEARING LIFE n=25 n=50 n=75 n=100 n=125 n=200 n=300 n=450 EX 1 EX 2 120 bar 60 bar 250 bar 180 bar L50h 100000 50000 20000 10000 5000 2000 1000 30000 3000 F r Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] F r 20 kn 40 kn 60 kn a=200 mm a=150 mm Shaft stress limit a=100 mm a 80 kn a=50 mm Reference viscosity: 40 cst Example: We suppose (EX1): p=120 [bar], n=200 [rpm]; we obtain an average lifetime of 25000 [h]. If we suppose (EX2): F r =20 [kn], a=100 [mm], n=50 [rpm] and p=250 [bar] we obtain an average lifetime of 6500 [h]. 120 R8C rev.00 - Oct. 2018

R8C 5400 H7 - PERFORMANCE CURVES 5326 cc - WITHOUT FLUSHING 350 bar 310 bar 250 bar 180 bar 120 bar 60 bar 2620 cc - WITHOUT FLUSHING 350 bar 310 bar 250 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 121

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C 5400 H7 - PERFORMANCE CURVES 5326 cc - WITH FLUSHING 350 bar 310 bar 250 bar 180 bar 120 bar 60 bar 2620 cc - WITH FLUSHING 350 bar 310 bar 250 bar 180 bar 120 bar 60 bar Continuous operation Intermittent operation: permitted for a 15% of duty cycle, for 3 minutes maximum period Peak operation: permitted for very short periods (3-5 seconds every 10-15 minutes) The above diagrams are referring to the hydraulic motor working with a fluid in ideal conditions (viscosity at 40 cst). In case the working temperature increases and viscosity reach values under the recommended values (see hydraulic fluid recommendations) flushing must be performed or ISO oil grade must be changed. The working temperature must not overcome 70 C. 122 R8C rev.00 - Oct. 2018

R8C 5400 H7 - PERFORMANCE CURVES CREEP SPEED - VOLUMETRIC EFFICIENCY 1310 1640 2620 3650 5 4 3 2 creep speed [rpm] 10 rpm 25 50 100 200 5326 cc 1 0 0 1 2 3 4 5 external leakage [l/min] 60 70 80 90 100 volumetric efficiency [%] 0 50 100 150 200 250 pressure [bar] Reference viscosity: 40 cst Example: We suppose (3650 cc): p=200 [bar], we obtain: external leakage 4,3 [l/min], shaft creep speed 1,5 [rpm]. If we suppose (3650 cc): p=200 [bar] and n=50 [rpm] we obtain a volumetric efficiency of 97,5%; BEARING LIFE n=25 n=50 n=75 n=100 n=125 n=200 n=300 n=450 EX 2 250 bar 120 bar 180 bar EX 1 60 bar L50h 100000 50000 20000 30000 10000 5000 3000 2000 1000 20 kn a=200 mm F r F r 40 kn a=150 mm Shaft stress limit a=100 mm Fr=radial load a=distance of radial load from mounting face n=shaft speed [rpm] a 60 kn 80 kn a=50 mm Reference viscosity: 40 cst Example: We suppose (EX1): p=120 [bar], n=100 [rpm]; we obtain an average lifetime of 31000 [h]. If we suppose (EX2): F r =20 [kn], a=100 [mm], n=75 [rpm] and p=180 [bar] we obtain an average lifetime of 6000 [h]. The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 123

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE R8C H7 - ORDERING CODE R8C - - - - H7 - - - - - - - - - - - - - - DISPLACEMENT 4600 5400 INTERCHANGEABILITY /MRH SERIE H7 SHAFT A1 A11 A12 A13 A2 A3 A31 A4 TACHOMETER TA TB TT1 TQ1 EST EST30 EST31 EST32 EST33 See pag. 128-132 SPECIAL FEATURES MP SPSL HPS CCW See pag. 33 NIP See pag. 33 Z - - Italgroup internal code DISTRIBUTOR D31B D31BJ D36B D36BJ D310B D310BJ D40 D40J D47 D47J D416 D416J D75 D75J D90 D90J See pag. 126-127 DISPLACEMENT CHANGE FITTING AND ACCESSORIES XY XY-SV C3-SV C3-12 SV C3-24 SV C3-HY SV C3-12 CSV C3-24 CSV C3-HY CSV See pag. 24-32 SPLINED BILLET SPLINED BAR SB10 SB27 SB24 See pag. 133-135 MAXIMUM AND MINIMUM DISPLACEMENTS EXAMPLES: R8C 5400 H7 A1 D90 SB10 (5326-0) R8C 4600/MRH H7 A13 D90 SB24 (4617-2290) R8C 4600 H7 A12 D90 C3-12 SV (4177-655) 124 R8C rev.00 - Oct. 2018

The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 125

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE MOTOR DISTRIBUTORS D40-D416-D31B-D310B-D36B-D316B N 2 PORTS F 105 D N 5 MTG HOLES 12,5 ON A 105 P.C.D. E N 2 PORTS R O G N T A C B D47-D75-D90 S N 4+4 V x W mm deep U H L N 5 MTG HOLES P ON A Q P.C.D. M 126 R8C rev.00 - Oct. 2018

D40 D416 D31B D310B D36B D316B D47 D75 D90 A [mm] 69 69 56 56 56 56 B [mm] 41 41 39 39 39 39 C [mm] 77 77 67 67 67 67 D [mm] 130 130 125 125 125 125 E [mm] 68 68 65 65 65 65 F [] 1 BSP 1 SAE 3/4 BSP MOTOR DISTRIBUTORS 1 BSP 3/4 SAE 1 SAE G [mm] 69 83 100 H [mm] 77 107 113 L [mm] 41 55 59 M [mm] 65 92 95 N [mm] 130 170 190 O [mm] 105 145 149 P [mm] 12,5 14,5 14,5 Q R [] 1 SAE 3000 1 1/2 SAE 3000 S [mm] 52,4 69,85 79,4 T [mm] 26,2 35,7 36,7 U [mm] 25 39 40 V [mm] M10 M12 M16 W [mm] 19 22 22 1 1/2 SAE 6000 D31B D310B D36B D40 D416 D47 D75 D90 MAX. CONT. FLOW [l/min] 200 300 200 300 300 300 600 700 MAX. FLOW [l/min] 400 400 400 400 400 400 1000 1200 MAX. CONT. PRESSURE [bar] 300 300 300 300 300 300 300 300 PEAK PRESSURE [bar] 500 500 500 500 500 500 500 500 R8C H1 R8C H3 R8C H4 R8C H5 R8C H55 R8C H6 R8C H7 Standard version Special version: available on request. Please contact Italgroup for more details The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 127

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE TACHOMETERS J Tacho drive plug 1/2 BSP DISTRIBUTOR TYPE A D40/D416/D47 75,5 D31B/D310B/D36B/D316B 63,5 D75 101 D90 107 10,5 A Tachometer predisposition ONLY TA M18x1 3 20 17 22 DISTRIBUTOR TYPE A D40/D416/D47 114,5 D31B/D310B/D36B/D316B 102,5 D75 140 D90 146 A 128 R8C rev.00 - Oct. 2018

TACHOMETERS TB 22 20 H8 3 M8 10 DISTRIBUTOR TYPE A D40/D416/D47 125,5 D31B/D310B/D36B/D316B 113,5 D75 151 D90 157 26,5 32 A TT1 DETAIL X 7,5 6 N 2 M8 DEPTH 12 mm 2,6-0 0,1 + 5 DISTRIBUTOR TYPE A D40/D416/D47 90,5 64 22 H7 X 48 D31B/D310B/D36B/D316B 78,5 D75 116 D90 122 7 12 A The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 129

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE TACHOMETERS TQ1 N 2 M8 DEPTH 12 mm 8 h8 5 DISTRIBUTOR TYPE A 64 22 H7 48 D40/D416/D47 90,5 D31B/D310B/D36B/D316B 78,5 D75 116 D90 122 15 12 A EST 9 76 120 DISTRIBUTOR TYPE A D40/D416/D47 87,5 85 6 f7 46 D31B/D310B/D36B/D316B 75,5 D75 113 D90 119 N 3 M4 DEPTH 9 mm 10 A N 4 M3 DEPTH 6 mm 40 130 R8C rev.00 - Oct. 2018

TACHOMETERS EST 30 M5x1 29 8 DISTRIBUTOR TYPE A D40/D416/D47 93,5 D31B/D310B/D36B/D316B 81,5 D75 119 D90 125 89 60 28 A EST 30 ELECTRIC DATA POWER SUPPLY 10-30 VDC IMPULSE / RPM 30 PROTECTION DEGREE IP67 OUTPUT NPN / PNP (*) (*) Customer has to select it at the order stage. In case of non-indication by customer, NPN version will be supplied as standard. EST 31 TACHOMETER TACHOMETER WIRE WIRE DISTRIBUTOR TYPE A D40/D416/D47 93,5 89 58 89 58 D31B/D310B/D36B/D316B 81,5 D75 119 D90 125 54 54 A A EST 31 ELECTRIC DATA POWER SUPPLY 8-24 VDC IMPULSE / RPM 500 PROTECTION DEGREE IP65 OUTPUT PUSH-PULL The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 131

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE TACHOMETERS EST 32 HOLE FOR M16x1,5 CABLE GLAND IP68 DISTRIBUTOR TYPE A D40/D416/D47 93,5 D31B/D310B/D36B/D316B 81,5 D75 119 D90 125 69 34 A EST 32 ELECTRIC DATA POWER SUPPLY 8-24 VDC IMPULSE / RPM 4096 PROTECTION DEGREE IP67 OUTPUT SSI interface EST 33 M12x1 THREAD FOR TACHOMETER FITTING 89 DISTRIBUTOR TYPE A B D40/D416/D47 99,5 88 D31B/D310B/D36B/D316B 87,5 76 D75 125 113,5 D90 131 119,5 SENSOR NOT INCLUDED B A 132 R8C rev.00 - Oct. 2018

SPLINED BILLETS SB3 69 36 UNI 221 SB5 94 66 42,3 98 54,3 64 46 UNI 221 22 For: R8C 500 H3 A0 30 3 For: R8C 500/C H3 A0 SB6 93 62 UNI 221 SB7 75 98 72,5 82 88 62,5 BS 3550 1963 ASA B.5.15.1960 PITCH 6/12 Z=14 88 26 3 18 3 For: R8C 1400 H5 A0 R8C 3000/MR1400 H6 A0 For: R8C 1400 H5 A1 SB9 124 82 UNI 221 SB10 100 148 92,1 BS 3550 1963 ASA B.5.15.1960 PITCH 6/12 Z=14 148 90 26 40 40 For: R8C 2200 H55 A0 R8C 3000 H6 A0 25 For: R8C 2200 H55 A1 R8C 3000 H6 A1 R8C 4600 H7 A1 R8C 5400 H7 A1 R8C 2200/MRH H55 A1 R8C 4600/MRH H7 A1 R8C 5400/MRH H7 A1 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 133

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE SPLINED BILLETS SB14 SB16 46 28 UNI 221 80 98 60,1 52 UNI 222 58 34,5 18 For: R8C 195 H1 A0 R8C 195/S H1 A0 R8C 195/BH H1 A0 R8C 250 H1 A0 R8C 250/S H1 A0 R8C 250/BH H1 A0 16 For: R8C 800/C H4 A0 148 98 58,6 BS 3550 1963 ASA B.5.15.1960 PITCH 5/10 Z=16 87 31 SB21 137 105 57 30 SB27 57 89 BS 3550 1963 ASA B.5.15.1960 PITCH 8/16 Z=17 For: R8C 500/B30 H3 A1 R8C 800/B45 H4 A1 R8C 800/MRH H4 A1 148 BS 3550 1963 ASA B.5.15.1960 PITCH 6/12 Z=23 87 88 55,5 SB24 137 28 113 SB30 79 10 57 102 For: R8C 3000/MRH H6 A13 R8C 4600/MRH H7 A13 R8C 5400/MRH H7 A13 N55x3x17-9H DIN 5480 72 28 113 10 For: R8C 3000 H6 A12 R8C 4600 H7 A12 R8C 5400 H7 A12 17 3 For: R8C 500/B30 A11 R8C 500/C A11 134 R8C rev.00 - Oct. 2018

SPLINED BILLETS - SPLINED BARS SB32 46 58 N35x2x16-9H DIN 5480 35,5 18 For: R8C 195 H1 A1 R8C 195/S H1 A1 R8C 195/BH H1 A1 R8C 250 H1 A1 R8C 250/S H1 A1 R8C 250/BH H1 A1 B8076 W40x3x12-7e DIN 5480 100 For: R8C 500 H3 A3 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 135

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE ADAPTOR FLANGES FL2 FL4 38 N 6 M10 25 mm DEEP 60 40 76 40 N 6 M12 21 mm DEEP 73 60 60 90 50 N 2 25 142 68 68 N 2 31 162 Connection block, fitting D47 distributor, for motor MR350/450/500/600/700/800 Connection block, fitting D75 distributor, for motor MR1100/1400/1600/1800/2100 FL5 FL6 N 6 3/8"-24 UNF 2B, 16 mm DEEP 60 90 44 90 44 45 45 N 6 3/8"-24 UNF 2B, 16 mm DEEP 51 N 2 28 with OR 4137 housing 51 148 51 N 2 31 with OR 4150 housing 48 148 48 Connection block, fitting D75 distributor, for motor HMB 60/80/100 - S03 Connection block, fitting D75 distributor, for motor HMB 60/80/100 - S04 136 R8C rev.00 - Oct. 2018

ADAPTOR FLANGES FL7 FL10 58 N 6 3/8"-24 UNF 2B, 16 mm DEEP 50,8 110 44,4 N 2 32 with OR 4150 housing 47,6 165 47,6 FL16 110 50,8 58 40 N 6 M14 28 mm DEEP 86 90 62 N 2 37 90 210 90 Connection block, fitting D90 distributor, for motor HMB 125/150/200 - S04 Connection block, fitting D75 distributor, for motor MR 2400/2800, MRE 3100 N 6 3/8"-24 UNF 2B, 16 mm DEEP 66,7 N 2 35 with O-Ring housing 45x2,8 mm DEEP 60 165 60 Connection block, fitting D90 distributor, for motor HMB 270/325 - S04 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 137

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE 138 R8C rev.00 - Oct. 2018

R8C - VALVES SINGLE OVERCENTER - OVSA 160 Pag. 140 DOUBLE OVERCENTER - OVDA 160 Pag. 141 FLUSHING - AP 40 Pag. 142 DOUBLE RELIEF - RVDA 80 Pag. 143 ANTICAVITATION - AC 80 Pag. 144 DOUBLE RELIEF AND ANTICAVITATION - RVDAC 80 Pag. 145 DOUBLE RELIEF AND FLUSHING - RVDAP 80 Pag. 146 SINGLE RELIEF AND ANTICAVITATION - RVSAC 200 Pag. 147 DOUBLE OVERCENTER - OVDA 300 Pag. 148 DOUBLE RELIEF - RVDA 200 Pag. 149 SINGLE RELIEF AND OVERCENTER - ORVSA 200 Pag. 150 DOUBLE RELIEF AND SINGLE OVERCENTER - DRVSO200EP Pag. 151 DOUBLE OVERCENTER - OVDA 480 Pag. 152 DOUBLE RELIEF - RVDA 380 Pag. 153 SINGLE RELIEF AND OVERCENTER - ORVSA 480 Pag. 154 DOUBLE RELIEF AND FLUSHING - RVDAP 90 Pag. 155 VALVES ORDERING CODE Pag. 156 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 139

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE SINGLE OVERCENTER - OVSA 160 (225) 75 150 78 55 C1 F C2 25 195 106 69 O-ring 4137 (2-220) PORTS DIMENSION V1, V2 1 BSP F 1/4 BSP C1, C2 O-Ring 4137 Parker code 2-220 78 52.4 V1 26.2 52.4 V2 26.2 N 4+4 10.5 MTG HOLES SPOT FACING 16.5 DEPTH 10.5 TECHNICAL DATA OVSA.160.1.D47 OVSA.160.2.D47 OVSA.160.3.D47 NOMINAL FLOW [l/min] 120 120 120 MAXIMUM FLOW [l/min] 160 160 160 MAXIMUM PRESSURE [bar] 350 350 350 PILOT RATIO [] 1 (3:1) 2 (4.5:1) 3 (10:1) RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350 STANDARD RELIEF SETTING [bar] 210 210 210 BLOCK MATERIAL [] steel steel steel DISTRIBUTOR FITTING [] D47 D47 D47 Pressure loss [bar] 30 20 10 Cartridge characteristic pilot opening 0 0 30 60 90 120 Flow [l/min] free flow Hydraulic circuit C1 C2 V1 F V2 140 R8C rev.00 - Oct. 2018

DOUBLE OVERCENTER - OVDA 160 (240) 120 120 F 78 55 25 ~305 143 69 O-ring 4137 (2-220) PORTS DIMENSION 78 V1 C1 52.4 C2 V2 52.4 V1, V2 1 BSP F 1/4 BSP 26.2 26.2 C1, C2 O-Ring 4137 Parker code 2-220 N 4+4 10.5 MTG HOLES SPOT FACING 16.5 DEPTH 10.5 TECHNICAL DATA OVDA.160.1.D47 OVDA.160.2.D47 OVDA.160.3.D47 NOMINAL FLOW [l/min] 120 120 120 MAXIMUM FLOW [l/min] 160 160 160 MAXIMUM PRESSURE [bar] 350 350 350 PILOT RATIO [] 1 (3:1) 2 (4.5:1) 3 (10:1) RELIEF VALVE SETTING RANGE [bar] 70-280 40-350 140-350 STANDARD RELIEF SETTING [bar] 210 210 210 BLOCK MATERIAL [] steel steel steel DISTRIBUTOR FITTING [] D47 D47 D47 Pressure loss [bar] 30 20 10 Cartridge characteristic 0 0 30 60 90 120 Flow [l/min] pilot opening free flow Hydraulic circuit C1 C2 V1 F V2 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 141

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE FLUSHING - AP 40 152 PORTS DIMENSION V1, V2 1 BSP F 1/4 BSP C1, C2 O-Ring 4137 Parker code 2-220 80 103 52 52.4 V1 C1 26.2 69 F C2 26.2 V2 52.4 N 4+4 10.5 MTG HOLES SPOT FACING 16.5 DEPTH 10.5 AP40.D47 MAXIMUM FLUSHING FLOW [l/min] 80 MAXIMUM PRESSURE [bar] 350 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D47 25 O-ring 4137 (2-220) TECHNICAL DATA Cartridge characteristic Hydraulic circuit Return line pressure [bar] 30 24 18 12 6 0 0 20 40 60 80 Flow [l/min] C1 C2 V1 F V2 142 R8C rev.00 - Oct. 2018

DOUBLE RELIEF - RVDA 80 ~230 142 78 25 C1 C2 26.2 26.2 O-ring 4137 (2-220) PORTS DIMENSION 78 52.4 V1 V2 52.4 V1, V2 1 BSP C1, C2 O-Ring 4137 Parker code 2-220 69 N 4+4 10.5 MTG HOLES SPOT FACING 16.5 DEPTH 10.5 TECHNICAL DATA RVDA.80.C.D47 NOMINAL FLOW [l/min] 150 MAXIMUM FLOW [l/min] 200 MAXIMUM PRESSURE [bar] 350 RELIEF VALVE SETTING RANGE [bar] C (20-350) STANDARD RELIEF SETTING [bar] 20 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D47 Cartridge typical pressure rise C1 Hydraulic circuit C2 Differential pressure [bar] 400 300 200 100 0 0 50 100 150 Flow [l/min] V1 V2 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 143

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE ANTICAVITATION - AC 80 142 58 AC 25 C1 26.2 26.2 C2 19 O-ring 4137 (2-220) PORTS DIMENSION 78 52.4 V1 V2 52.4 V1, V2 1 BSP AC 1/4 BSP C1, C2 O-Ring 4137 Parker code 2-220 69 N 4+4 10.5 MTG HOLES SPOT FACING 16.5 DEPTH 10.5 TECHNICAL DATA AC80.D47 NOMINAL FLOW [l/min] 150 MAXIMUM FLOW [l/min] 200 MAXIMUM PRESSURE [bar] 350 MAXIMUM ANTICAVITATION FLOW (FROM AC TO C1 OR C2) [l/min] 50 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D47 Check valve flow/pressure curve Delta pressure [bar] 8 6 4 2 0 0 10 20 30 Flow [l/min] 40 50 C1 V1 AC C2 V2 144 R8C rev.00 - Oct. 2018

RELIEF & ANTICAVITATION - RVDAC80 ~230 AC 108 C1 C2 69 25 O-Ring 4137 (2-220) N 4+4 Ø10.5 MTG HOLES 142 PORTS DIMENSION V1, V2 1 BSP 52.37 V1 V2 52.37 78 AC 1/4 BSP C1, C2 O-Ring 4137 Parker code 2-220 N 4+4 SPOT FACING Ø16.5 10.5 mm DEEP 26.19 69 26.19 TECHNICAL DATA RVDAC80.C.D47 NOMINAL FLOW [l/min] 150 MAXIMUM FLOW [l/min] 200 MAXIMUM PRESSURE [bar] 350 RELIEF VALVE SETTING RANGE [bar] C (20-350) STANDARD RELIEF SETTING [bar] 20 MAXIMUM ANTICAVITATION FLOW (FROM AC TO C1 OR C2) [l/min] 50 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D47 C1 C2 Relief cartridge typical pressure rise Check valve flow/pressure curve Differential pressure [bar] 400 300 200 100 0 0 50 100 150 Flow [l/min] Delta pressure [bar] 8 6 4 2 0 0 20 30 Flow [l/min] The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 10 40 50 V1 AC V2 145

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE RELIEF & FLUSHING - RVDAP80 ~230 142 F 78 25 C1 C2 26.2 26.2 O-ring 4137 (2-220) PORTS DIMENSION V1, V2 1 BSP 118 39 52.4 V1 V2 52.4 F 1/4 BSP C1, C2 O-Ring 4137 Parker code 2-220 69 N 4+4 10.5 MTG HOLES SPOT FACING 16.5 DEPTH 10.5 RVDAP80.C.D47 RELIEF VALVE MAXIMUM FLOW [l/min] 200 RELIEF VALVE SETTING RANGE [bar] C (20-350) STANDARD RELIEF SETTING [bar] 70 MAXIMUM FLUSHING FLOW [l/min] 80 MAXIMUM PRESSURE [bar] 350 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D47 TECHNICAL DATA Hydraulic circuit C1 C2 Relief cartridge typical pressure rise Flushing valve characteristic Differential pressure [bar] 400 300 200 100 0 0 50 100 150 Flow [l/min] Return line pressure [bar] 30 24 18 12 6 0 0 20 40 60 80 Flow [l/min] V1 F V2 146 R8C rev.00 - Oct. 2018

RELIEF & ANTICAVITATION - RVSAC200 M2 57 M1 98 (70.5) 69 (70.5) 22 40 130 C1 C2 O-ring 4137 (2-220) 39 V1 V2 52.4 128 PORTS DIMENSION V1, V2 1 BSP M1, M2 1/4 BSP C1, C2 O-Ring 4137 Parker code 2-220 26.2 210 26.2 ~55 N 4+4 10.5 MTG HOLES SPOT FACING 16.5 DEPTH 10.5 TECHNICAL DATA RVSAC200.C.D47 RELIEF VALVE MAXIMUM FLOW [l/min] 200 MAXIMUM PRESSURE [bar] 350 RELIEF VALVE SETTING RANGE [bar] C (70-420) STANDARD RELIEF SETTING [bar] 70 CHECK VALVE MAXIMUM FLOW [l/min] 160 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D47 Hydraulic circuit C1 C2 Relief cartridge typical pressure rise Differential pressure [bar] 400 300 200 100 0 0 100 200 300 Flow [l/min] (C2-C1) pressure drop [bar] [bar] Oil supply flow (from C2 to C1) 12 9 6 3 0 0 40 80 120 160 Flow [l/min] M1 V1 V2 M2 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 147

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE DOUBLE OVERCENTER - OVDA 300 35.7 35.7 N 4+4 MTG HOLES Ø12.5 98 69.85 C1 C2 69.85 93.5 83 93.5 (270) 18.5 98 12.5 F 74 PORTS DIMENSION 25 170 O-ring 4187 (2-225) V1, V2 1 1/4 BSP F 1/4 BSP C1, C2 O-Ring 4187 Parker code 2-225 V1 V2 ~360 TECHNICAL DATA OVDA.300.1.D75 OVDA.300.4.D75 OVDA.300.2.D75 NOMINAL FLOW [l/min] 240 240 240 MAXIMUM FLOW [l/min] 300 300 300 MAXIMUM PRESSURE [bar] 350 350 350 PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1) RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350 STANDARD RELIEF SETTING [bar] 210 210 210 BLOCK MATERIAL [] steel steel steel DISTRIBUTOR FITTING [] D75 D75 D75 Pressure loss [bar] Cartridge characteristic 30 20 pilot opening 10 free flow 0 0 60 120 180 240 Flow [l/min] Hydraulic circuit C1 C2 V1 F V2 148 R8C rev.00 - Oct. 2018

DOUBLE RELIEF - RVDA 200 N 4+4 12.5 18.5 ~260 12.5 28 98 C1 83 150 C2 O-ring 4187 (2-225) SPOT FACING Ø18.5 DEPTH 12.5 mm (33.5) 83 (33.5) PORTS DIMENSION V1, V2 1 1/4 BSP C1, C2 O-Ring 4187 Parker code 2-225 98 69.85 V1 N 4+4 Ø12.5 35.7 35.7 V2 69.85 RVDA.200.C.D75 RELIEF VALVE MAXIMUM FLOW [l/min] 200 MAXIMUM PRESSURE [bar] 350 RELIEF VALVE SETTING RANGE [bar] C (70-420) STANDARD RELIEF SETTING [bar] 70 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D75 Differential pressure [bar] Cartridge typical pressure rise 400 300 200 100 0 0 100 200 300 Flow [l/min] TECHNICAL DATA Hydraulic circuit C1 C2 V1 V2 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 149

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE RELIEF & OVERCENTER - ORVSA 200 ~45 228 ~43 85 F 72 C1 C2 83 O-Ring 4187 (Parker 2-225) PORTS DIMENSION 69.85 V1 V2 69.85 98 V1, V2 1 1/4 BSP F 1/4 BSP C1, C2 O-Ring 4187 Parker code 2-225 SPOT FACING 18.5 DEPTH 12,5 35.71 35.71 44.5 131.5 N 4+4 12.5 MTG. HOLES TECHNICAL DATA ORVSA.200.1.C.D75 ORVSA.200.4.C.D75 ORVSA.200.2.C.D75 NOMINAL FLOW [l/min] 240 240 240 MAXIMUM FLOW [l/min] 300 300 300 MAXIMUM PRESSURE [bar] 350 350 350 PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1) OVC RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350 OVC STANDARD RELIEF SETTING [bar] 210 210 210 RELIEF VALVE SETTING RANGE [bar] C (70-420) C (70-420) C (70-420) RELIEF STANDARD SETTING [bar] 70 70 70 BLOCK MATERIAL [] steel steel steel DISTRIBUTOR FITTING [] D75 D75 D75 Pressure loss [bar] OVC cartridge characteristic 30 20 pilot opening 10 free flow 0 0 60 120 180 240 Flow [l/min] 150 Differential pressure [bar] Relief cartridge typical pressure rise 400 300 200 100 0 0 100 200 300 Flow [l/min] C1 C2 V1 F V2 R8C rev.00 - Oct. 2018

RELIEF & OVERCENTER - DRVSO200EP ~49 223.5 ~285 P 25 85 40 C1 100 240 C2 O-Ring 4187 (Parker 2-225) 36.7 36.7 PORTS DIMENSION V1, V2 1 1/4 BSP P 1/4 BSP C1, C2 O-Ring 4137 Parker code 2-220 108 79.4 V1 40 150 240 V2 N 4+4 16.5 MTG HOLES SPOT FACING 24.5 DEPTH 16.5 TECHNICAL DATA DRVSO200EP.1.C.D75 DRVSO200EP.4.C.D75 DRVSO200EP.2.C.D75 NOMINAL FLOW [l/min] 240 240 240 MAXIMUM FLOW [l/min] 300 300 300 MAXIMUM PRESSURE [bar] 350 350 350 PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1) OVC RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350 OVC STANDARD RELIEF SETTING [bar] 210 210 210 RELIEF VALVE SETTING RANGE [bar] C (70-420) C (70-420) C (70-420) RELIEF STANDARD SETTING [bar] 70 70 70 BLOCK MATERIAL [] steel steel steel DISTRIBUTOR FITTING [] D75 D75 D75 OVC cartridge characteristic Relief cartridge typical pressure rise C1 C2 Pressure loss [bar] 30 20 pilot opening 10 free flow 0 0 60 120 180 240 Flow [l/min] Differential pressure [bar] 400 300 200 100 0 0 100 200 300 Flow [l/min] P V1 V2 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 151

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE DOUBLE OVERCENTER - OVDA 480 170 118 39 C1 F C2 89 100 O-ring 4187 (2-225) ~60 340 ~60 36.7 36.7 PORTS DIMENSION V1, V2 1 1/2 BSP F 1/4 BSP 118 79.4 V1 V2 79.4 C1, C2 O-Ring 4187 Parker code 2-225 (63.5) 213 (63.5) N 4+4 16.5 MTG HOLES SPOT FACING 24.5 DEPTH 16.5 TECHNICAL DATA OVDA.480.1.D90 OVDA.480.4.D90 OVDA.480.2.D90 NOMINAL FLOW [l/min] 480 480 480 MAXIMUM FLOW [l/min] 600 600 600 MAXIMUM PRESSURE [bar] 350 350 350 PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1) RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350 STANDARD RELIEF SETTING [bar] 210 210 210 BLOCK MATERIAL [] steel steel steel DISTRIBUTOR FITTING [] D90 D90 D90 Pressure loss [bar] Cartridge characteristic 30 pilot opening 20 10 free flow 0 0 120 240 360 480 Flow [l/min] Hydraulic circuit C1 C2 V1 F V2 152 R8C rev.00 - Oct. 2018

DOUBLE RELIEF - RVDA 380 ~75 ~75 118 C1 C2 (42,5) (42,5) 100 O-ring 4187 (2-225) V2 PORTS DIMENSION V1, V2 1 1/2 BSP 118 79,4 V1 C1, C2 O-Ring 4187 Parker code 2-225 36,7 185 N 4+4 16.5 MTG HOLES SPOT FACING 24.5 DEPTH 16.5 TECHNICAL DATA RVDA.380.C.D90 RELIEF VALVE MAXIMUM FLOW [l/min] 380 MAXIMUM PRESSURE [bar] 350 RELIEF VALVE SETTING RANGE [bar] C (70-420) STANDARD RELIEF SETTING [bar] 70 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D90 Cartridge typical pressure rise Hydraulic circuit C1 C2 Differential pressure [bar] 400 300 200 100 0 0 100 200 300 400 Flow [l/min] V1 V2 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 153

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE RELIEF & OVERCENTER - ORVSA 480 ~(391) ~60 250 ~81 118 25 F 85 90 C2 100 C1 O-Ring 4187 (Parker 2-225) PORTS DIMENSION V1, V2 1 1/2 BSP 118 79.4 V2 V1 79.4 F 1/4 BSP C1, C2 O-Ring 4187 Parker code 2-225 N 4+4 16.5 MTG HOLES 36.7 36.7 150 35 SPOT FACING 21.5 DEPTH 16.5 TECHNICAL DATA ORVSA.480.1.D90 ORVSA.480.4.D90 ORVSA.480.2.D90 NOMINAL FLOW [l/min] 480 480 480 MAXIMUM FLOW [l/min] 600 600 600 MAXIMUM PRESSURE [bar] 350 350 350 PILOT RATIO [] 1 (3:1) 4 (10:1) 2 (4.5:1) OVC RELIEF VALVE SETTING RANGE [bar] 70-280 140-350 140-350 OVC STANDARD RELIEF SETTING [bar] 210 210 210 RELIEF VALVE SETTING RANGE [bar] C (70-420) C (70-420) C (70-420) RELIEF STANDARD SETTING [bar] 70 70 70 BLOCK MATERIAL [] steel steel steel DISTRIBUTOR FITTING [] D90 D90 D90 OVC cartridge characteristic Relief cartridge typical pressure rise C1 C2 Pressure loss [bar] 154 30 pilot opening 20 10 free flow 0 0 120 240 360 480 Flow [l/min] Differential pressure [bar] 400 300 200 100 0 0 100 200 300 400 Flow [l/min] V1 F V2 R8C rev.00 - Oct. 2018

RELIEF & FLUSHING - RVDAP 90 119.5 64.5 92.5 38 F ~139.65 C1 C2 ~75 185 ~75 36.7 36.7 O-ring 4187 (2-225) PORTS DIMENSION V1, V2 1 BSP 120 79.4 V1 V2 79.4 F 3/8 BSP C1, C2 O-Ring 4187 Parker code 2-225 (42.5) 100 (42.5) RVDAP90.C.D90 RELIEF VALVE MAXIMUM FLOW [l/min] 380 RELIEF VALVE SETTING RANGE [bar] C (70-420) STANDARD RELIEF SETTING [bar] 70 MAXIMUM FLUSHING FLOW [l/min] 80 MAXIMUM PRESSURE [bar] 350 BLOCK MATERIAL [] steel DISTRIBUTOR FITTING [] D90 TECHNICAL DATA C1 Hydraulic circuit C2 Relief cartridge typical pressure rise Oil supply flow (from C2 to C1) Differential pressure [bar] 400 300 200 100 0 0 100 200 300 400 Flow [l/min] (C2-C1) pressure drop [bar] [bar] 12 9 6 3 0 0 40 80 120 160 Flow [l/min] V1 F V2 The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 155

ITALGROUP MOTORS R8C SERIES TECHNICAL CATALOGUE VALVES - ORDERING CODE - - - - - - - - - - - - - - - D - - VALVE TYPE SIZE RATIO OVC REQUESTED SETTING (OPTIONAL) RELIEF SETTING RANGE RELIEF REQUESTED SETTING (OPTIONAL) DISTRIBUTOR FITTING OVSA 160 1 2 3 - - - D47 OVDA 160 1 2 3 - - - D47 300 1 2 3 - - - D75 480 1 2 3 - - - D90 ORVSA 200 1 2 3 - - - C 480 1 2 3 - - - C DRVSO 200 EP 1 2 3 - - - C RVDA 80 C 200 C 380 C - - - - - - - - - - - - - - - - - - D75 D90 D75 D47 D75 D90 RVDAP 80 C - - - D47 90 C - - - D90 RVSAC 200 C - - - D47 RVDAC 80 C - - - D47 AP 40 D47 AC 80 D47 EXAMPLES: OVDA 160 1 200 D47 AP 40 D47 ORVSA 480 3 250 C 200 D90 ORVSA 200 1 C D75 156 R8C rev.00 - Oct. 2018

CONTACT US The data specified into the catalogue are for product description purpose only and must not be interpreted as warranted characteristics in legal sense. Italgroup S.r.l. reserves the right to implement modifications without notice. All partial or total reproduction and copy without written authorization of Italgroup S.r.l. is strictly forbidden. 157

Europe Austria Belgium Croatia Czech Republic Cyprus Denmark Faroe Islands France Finland Germany Greece Iceland Italy Netherland Norway Poland Portugal Russia Slovenia Spain Sweden Switzerland Turkey Ukraina United Kingdom Asia Oceania China Hong Kong India Indonesia Iran Israel Philippines Russia Belarus Singapore South Korea Thailand Taiwan United Arab Emirates Vietnam Australia New Zeland Africa America Egypt South Africa Tunisia Argentina Brazil Canada Chile Mexico Peru USA Colombia salvioli.it R8C rev. 00 Italgroup S.r.l. - Via Pacinotti 20/22-41013 Gaggio di Piano - CASTELFRANCO EMILIA (MODENA) - Italy R8D rev.00 - Oct. 2018 Tel. +39 059.924257 - Fax +39 059.920113 - Email: italgroup@italgroup.eu - www.italgroup.eu