MC or MV-105 Copper, TR-XLPE Insulated

Similar documents
MC, THHN/THWN-2 Copper

TC-RHH/RHW-2 USE-2 Copper

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

MEDIUM VOLTAGE

High Voltage Copper, Smooth Aluminum Shield/Sheath

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

C-L-X Aluminum Sheath Type IEC

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

Okoguard -Okoseal Type IEC

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs


CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

Medium Voltage Cable. marmonutility.com

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

UNSHIELDED MULTI CONDUCTOR

Medium Voltage Power Cables

Type MMV-WP Medium Voltage Wind Power Cable

Your Partner in Safe Power Solutions. About RESCAB

Medium Voltage Cables for PermaLife Nuclear Utility Applications

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

600/1000V, XLPE Insulated Cables according to IEC

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

INDUSTRIAL

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

Omni Cable is a master distributor of specialty wire and cable selling

Wired for Power Generation

Section 8. Portable Cordage & Power Cable

Easier! Faster! Safer!

TUNNELING POWER CABLES

IEEE 1580 TYPE T/N CABLE

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

Power & Control Cable IEC

E R C. R E R C ; ; W T E C

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables

Type P Drilmar 125-XE Signal & Instrumentation

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Type P Drilmar 125-XE Signal & Instrumentation

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

Variable Frequency Drive (VFD) Cable Solutions

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

Power & Control Cable IEC

Automotive Cables. The Global Cable Solutions Company

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Category # 1 - Overhead, Primary, & Secondary Conductors

NEC 2014 Code Changes

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

ELECTRICAL MATERIALS. Hot-dip galvanize the inside and outside surfaces of rigid steel conduit and fittings.

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

Airfield Ground Lighting

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

Company Profile. Caledonian Medium Voltage Cables

MEDIUM VOLTAGE POWER CABLES

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

Caledonian Fire Resistant Optic Fiber Cables

BS6724 SWA/LSZH Cable IEC /1000V

Any inquiries, please feel free to contact or Caledonian

STABILOY BRAND FeeDeR SOLuTIONS

SECONDARY 600 VOLT CABLES

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

All rights reserved. No part of this manual may be reproduced or utilized in any form or by any means, electronic or mechanical, including

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG

Quintas & Quintas Group

UNDERGROUND TRANSMISSION SOLUTIONS

Mecklenburg County Common Code Defects

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

Transcription:

MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with NEC meeting UL 1685 vertical-tray flame exposure. s 4/0 and larger are marked FT4 meeting vertical-tray test per IEEE 1202 at 70,000 BTU/hr. Cable with supplementary sunlight resistance jacket, and grounding conduct, is rated f Direct Burial. True Triple extrusion system and closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends. Application Primary power and distribution circuits in industrial and commercial installations. May be used in wet dry locations, where exposed concealed, installed in cable trays, raceways, duct, and open air, aerially directly buried. In hazardous (classified) locations Class I, Division 2, as permitted by NEC. Standards UL 1072 Medium Voltage Power Cables. ICEA S93-639/WC 74 Standard f Utility Shielded Power Cables rated 5 kv 46 kv. AEIC CS8 Specification f Extruded Dielectric, Shielded Power Cables rated 5 kv 46 kv. Specifications Maximum operating voltage: 5 kv to 35 kv 100% and 133% IL Maximum conduct operation temperature: 105 C wet and dry Engineering Infmation 1. Conduct: St annealed uncoated copper compacted Class B per ASTM B496. On request, compacted strand aluminum conduct. s: 8 up to 1000. 2. Conduct Shield: Semi conducting cross-linked polyethylene (XLPE). 3. Insulation: Thermoset tree retardant cross-linked polyethylene (TR-XLPE). 4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE). 5. Phase ID: Coled strings (black, red and white yarns.) On request, Other col yarns are available. 1 2 3 6. Metallic Shield: St annealed uncoated copper tape, 5 mil thick, 25% minimum overlap. 7. : One three stannealed bare copper conducts cabled with phase conducts. 7 8 9 10 11 8. Assembly: Conducts cabled with non hygroscopic fillers, as required and binder tape. 9. Inner (Optional): Black sunlight resistance and flame retardant polyvinyl chlide (PVC) compound. 10. : An aluminum galvanized steel interlocked arm, applied over the binder tape the optional inner jacket (25 mils to 30 mils thickness depending on cable construction.) 11. (Supplementary): Sunlight resistance and flame retardant polyvinyl chlide (PVC) compound. 5/8 kv 15 kv Rest Yellow Red Black 4 5 6 CME Wire and Cable 495 Hizon Drive NE, Suite 100, Suwanee, Gegia 30024 www.cmewire.com 770.623.0001 ed Cables

ed Cable / MC MV-105 Copper, TR-XLPE Insulated, 5 kv 35 kv, Shielded 5 kv Interlocked, TR-XLPE Insulated Conduct 100% and 133% Insulation Levels (90 mil) in mil in lb/kft lb/kft 8 7 0.13 8 50 1.27 1196 911 6 7 0.17 6 50 1.34 1393 1097 4 7 0.21 6 50 1.44 1655 1333 2 7 0.27 6 50 1.61 1959 1652 1 19 0.30 4 60 1.69 2253 1948 1/0 19 0.34 4 60 1.77 2557 2234 2/0 19 0.38 4 60 1.86 2925 2582 3/0 19 0.42 3 60 1.96 3399 3043 4/0 19 0.48 3 60 2.07 3959 3576 250 37 0.52 2 60 2.19 4476 4065 300 37 0.57 2 60 2.30 5112 4691 350 37 0.62 2 75 2.43 5796 5352 400 37 0.66 1 75 2.52 6398 5932 500 37 0.74 1 75 2.69 7607 7123 600 61 0.81 1/0 75 2.93 8945 8405 750 61 0.91 1/0 75 3.13 10710 10147 1000 61 1.06 2/0 85 3.48 13666 13026 8 kv Interlocked, TR-XLPE Insulated Conduct 100% Insulation Level (115 mil) 133% Insulation Level (140 mil) The above data are approximate and subject to nmal manufacturing tolerances. Where required, the compatibility with glands, connects and accessies should be verified using actual dimensions the product. Other sizes available upon request. Ampacities: Refer to beginning section. * At the option manufacturer, Ground Conduct can be divided in three, one in each interstice. in mil in lb/kft lb/kft mil in lb/kft lb/kft 8 7 0.13 8 50 1.38 1339 1023 6 7 0.17 6 50 1.45 1541 1214 6 50 1.61 1616 1309 4 7 0.21 6 50 1.55 1809 1456 6 60 1.73 1919 1589 2 7 0.27 6 60 1.74 2148 1816 6 60 1.85 2312 1953 1 19 0.30 4 60 1.80 2413 2083 4 60 1.91 2581 2224 1/0 19 0.34 4 60 1.88 2723 2373 4 60 1.99 2895 2520 2/0 19 0.38 4 60 1.97 3097 2727 4 60 2.08 3275 2879 3/0 19 0.42 3 60 2.07 3577 3195 3 60 2.18 3762 3354 4/0 19 0.48 3 60 2.18 4144 3735 3 60 2.29 4336 3901 250 37 0.52 2 60 2.30 4669 4232 2 75 2.44 4943 4480 300 37 0.57 2 75 2.44 5386 4939 2 75 2.55 5596 5123 350 37 0.62 2 75 2.54 6006 5535 2 75 2.65 6222 5725 400 37 0.66 1 75 2.63 6614 6121 1 75 2.74 6836 6318 500 37 0.74 1 75 2.85 7949 7427 1 75 2.96 8188 7640 600 61 0.81 1/0 75 3.04 9187 8621 1/0 75 3.15 9436 8844 750 61 0.91 1/0 85 3.26 11032 10443 1/0 85 3.37 11299 10684 1000 61 1.06 2/0 85 3.59 13945 13278 2/0 85 3.70 14231 13538 CME Wire and Cable 495 Hizon Drive NE, Suite 100, Suwanee, Gegia 30024 www.cmewire.com 770.623.0001

ed Cable / MC MV-105 Copper, TR-XLPE Insulated, 5 kv 35 kv, Shielded 15 kv Interlocked TR-XLPE Insulated 5 Conduct 100% Insulation Level (175 mil) 133% Insulation Level (220 mil) in mil in lb/kft lb/kft mil in lb/kft lb/kft 2 7 0.27 6 60 2.00 2552 2157 6 60 2.20 2882 2440 1 19 0.30 4 60 2.07 2827 2434 4 60 2.26 3165 2725 1/0 19 0.34 4 60 2.15 3149 2737 4 60 2.34 3496 3037 2/0 19 0.38 4 60 2.23 3537 3104 4 75 2.46 3969 3489 3/0 19 0.42 3 60 2.33 4033 3588 3 75 2.56 4479 3988 4/0 19 0.48 3 75 2.48 4692 4221 3 75 2.67 5080 4562 250 37 0.52 2 75 2.60 5239 4740 2 75 2.84 5756 5198 300 37 0.57 2 75 2.70 5902 5392 2 75 2.95 6435 5867 350 37 0.62 2 75 2.85 6653 6108 2 75 3.05 7085 6494 400 37 0.66 1 75 2.95 7279 6712 1 75 3.14 7722 7108 500 37 0.74 1 75 3.11 8529 7945 1 85 3.33 9060 8429 600 61 0.81 1/0 85 3.32 9865 9236 1/0 85 3.52 10353 9677 750 61 0.91 1/0 85 3.52 11679 11027 1/0 85 3.72 12191 11493 1000 61 1.06 2/0 85 3.85 14643 13914 25 kv Interlocked, TR-XLPE Insulated 100% Insulation Levels (260 mil) Conduct in mil in lb/kft lb/kft 1 19 0.30 4 75 2.47 3560 3078 1/0 19 0.34 4 75 2.55 3901 3401 2/0 19 0.38 4 75 2.64 4310 3789 3/0 19 0.42 3 75 2.74 4832 4298 4/0 19 0.48 3 75 2.90 5561 4990 250 37 0.52 2 75 3.02 6139 5539 300 37 0.57 2 75 3.13 6829 6219 350 37 0.62 2 85 3.25 7555 6922 400 37 0.66 1 85 3.34 8203 7548 500 37 0.74 1 85 3.51 9493 8821 600 61 0.81 1/0 85 3.69 10806 10089 750 61 0.91 1/0 85 3.90 12665 11926 The above data are approximate and subject to nmal manufacturing tolerances. Where required, the compatibility with glands, connects and accessies should be verified using actual dimensions the product. Other sizes available upon request. Ampacities: Refer to beginning section. * At the option manufacturer, Ground Conduct can be divided in three, one in each interstice. CME Wire and Cable 495 Hizon Drive NE, Suite 100, Suwanee, Gegia 30024 www.cmewire.com 770.623.0001

ed Cable / MC MV-105 Copper, TR-XLPE Insulated, 5 kv 35 kv, Shielded 35 kv Interlocked TR-XLPE Insulated Conduct 100% Insulation Levels (345 mil) in mil in lb/kft lb/kft 1/0 19 0.34 4 75 2.97 4789 4188 2/0 19 0.38 4 75 3.06 5220 4599 3/0 19 0.42 3 75 3.16 5767 5134 4/0 19 0.48 3 85 3.29 6475 5815 250 37 0.52 2 85 3.41 7081 6393 300 37 0.57 2 85 3.52 7797 7099 350 37 0.62 2 85 3.62 8481 7759 400 37 0.66 1 85 3.71 9149 8406 500 37 0.74 1 85 3.88 10475 9715 5 kv Interlocked, TR-XLPE Insulated, Inner Conduct 100% and 133% Insulation Levels (90 mil) in mil in lb/kft lb/kft 6 7 0.17 6 50 1.51 1676 1332 4 7 0.21 6 60 1.68 1904 1586 2 7 0.27 6 60 1.80 2302 1954 1 19 0.30 4 60 1.86 2573 2228 1/0 19 0.34 4 60 1.94 2890 2526 2/0 19 0.38 4 60 2.03 3273 2888 3/0 19 0.42 3 60 2.19 3907 3494 4/0 19 0.48 3 60 2.30 4492 4053 250 37 0.52 2 75 2.45 5111 4643 300 37 0.57 2 75 2.56 5774 5296 350 37 0.62 2 75 2.66 6410 5909 400 37 0.66 1 75 2.75 7033 6510 500 37 0.74 1 75 2.92 8279 7738 600 61 0.81 1/0 75 3.16 9944 9073 750 61 0.91 1/0 85 3.45 11772 11136 1000 61 1.06 2/0 85 3.77 14758 14045 The above data are approximate and subject to nmal manufacturing tolerances. Where required, the compatibility with glands, connects and accessies should be verified using actual dimensions the product.. Other sizes available upon request. Ampacities: Refer to beginning section. * At the option manufacturer, Ground Conduct can be divided in three, one in each interstice. CME Wire and Cable 495 Hizon Drive NE, Suite 100, Suwanee, Gegia 30024 www.cmewire.com 770.623.0001

ed Cable / MC MV-105 Copper, TR-XLPE Insulated, 5 kv 35 kv, Shielded 8 kv Interlocked TR-XLPE Insulated, Inner 5 Conduct 100% Insulation Level (115 mil) 133% Insulation Level (140 mil) in mil in lb/kft lb/kft mil in lb/kft lb/kft 4 7 0.21 6 60 1.79 2071 1726 2 7 0.27 6 60 1.91 2476 2102 6 60 2.02 2657 2257 1 19 0.30 4 60 1.97 2752 2380 4 60 2.14 3078 2665 1/0 19 0.34 4 60 2.05 3074 2683 4 60 2.22 3411 2978 2/0 19 0.38 4 60 2.20 3606 3180 4 60 2.31 3810 3357 3/0 19 0.42 3 60 2.30 4110 3671 3 75 2.44 4394 3929 4/0 19 0.48 3 75 2.44 4776 4311 3 75 2.55 4997 4505 250 37 0.52 2 75 2.56 5332 4838 2 75 2.67 5560 5040 300 37 0.57 2 75 2.67 6002 5498 2 75 2.78 6237 5707 350 37 0.62 2 75 2.77 6644 6117 2 75 2.88 6886 6332 400 37 0.66 1 75 2.86 7273 6724 1 75 2.97 7521 6945 500 37 0.74 1 75 3.08 8657 8078 1 85 3.27 9194 8574 600 61 0.81 1/0 85 3.35 10220 9581 1/0 85 3.46 10503 9838 750 61 0.91 1/0 85 3.56 12061 11399 1/0 85 3.67 12357 11670 1000 61 1.06 2/0 85 3.88 15068 14329 2/0 85 3.99 15385 14620 15 kv Interlocked, TR-XLPE Insulated, Inner Conduct 100% Insulation Level (175 mil) 133% Insulation Level (220 mil) in mil in lb/kft lb/kft mil in lb/kft lb/kft 2 7 0.27 6 60 2.23 3070 2618 6 75 2.46 3519 3020 1 19 0.30 4 60 2.30 3359 2909 4 75 2.53 3819 3322 1/0 19 0.34 4 60 2.38 3699 3230 4 75 2.61 4170 3654 2/0 19 0.38 4 75 2.49 4182 3693 4 75 2.69 4590 4053 3/0 19 0.42 3 75 2.60 4704 4202 3 75 2.79 5123 4575 4/0 19 0.48 3 75 2.71 5317 4789 3 75 2.91 5749 5174 250 37 0.52 2 75 2.83 5891 5334 2 75 3.07 6464 5849 300 37 0.57 2 75 2.93 6578 6011 2 85 3.27 7442 6801 350 37 0.62 2 75 3.08 7362 6761 2 85 3.37 8123 7458 400 37 0.66 1 85 3.26 8284 7644 1 85 3.46 8788 8101 500 37 0.74 1 85 3.43 9585 8928 1 85 3.62 10108 9405 600 61 0.81 1/0 85 3.61 10911 10209 1/0 85 3.81 11456 10708 750 61 0.91 1/0 85 3.82 12784 12060 1/0 85 4.02 13352 12582 The above data are approximate and subject to nmal manufacturing tolerances. Where required, the compatibility with glands, connects and accessies should be verified using actual dimensions the product. Other sizes available upon request. Ampacities: Refer to beginning section. * At the option manufacturer, Ground Conduct can be divided in three, one in each interstice. CME Wire and Cable 495 Hizon Drive NE, Suite 100, Suwanee, Gegia 30024 www.cmewire.com 770.623.0001

ed Cable / MC MV-105 Copper, TR-XLPE Insulated, 5 kv 35 kv, Shielded 25 kv Interlocked, TR-XLPE Insulated, Inner 100% Insulation Levels (260 mil) Conduct in mil in lb/kft lb/kft 1 19 0.30 4 75 2.70 4183 3644 1/0 19 0.34 4 75 2.78 4543 3985 2/0 19 0.38 4 75 2.87 4971 4393 3/0 19 0.42 3 75 2.97 5515 4925 4/0 19 0.48 3 75 3.13 6281 5653 250 37 0.52 2 85 3.33 7166 6494 300 37 0.57 2 85 3.44 7889 7207 350 37 0.62 2 85 3.54 8580 7875 400 37 0.66 1 85 3.63 9255 8527 500 37 0.74 1 85 3.80 10592 9848 600 61 0.81 1/0 85 3.99 11959 11170 35 kv Interlocked, TR-XLPE Insulated, Inner 100% Insulation Levels (345 mil) Conduct in mil in lb/kft lb/kft 1/0 19 0.34 4 85 3.29 5803 5129 2/0 19 0.38 4 85 3.38 6260 5566 3/0 19 0.42 3 85 3.48 6838 6132 4/0 19 0.48 3 85 3.59 7513 6781 250 37 0.52 2 85 3.71 8154 7393 300 37 0.57 2 85 3.82 8900 8130 350 37 0.62 2 85 3.91 9613 8819 400 37 0.66 1 85 4.01 10308 9492 The above data are approximate and subject to nmal manufacturing tolerances. Where required, the compatibility with glands, connects and accessies should be verified using actual dimensions the product. Other sizes available upon request. Ampacities: Refer to beginning section. * At the option manufacturer, Ground Conduct can be divided in three, one in each interstice. CME Wire and Cable 495 Hizon Drive NE, Suite 100, Suwanee, Gegia 30024 www.cmewire.com 770.623.0001