HOW TO TELL HAND OF DOOR:

Similar documents
*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions

*29268* 4600CS Electronic Low Energy Operator 4630CS PULL SIDE MOUNT 4640CS PUSH SIDE MOUNT. Table of Contents. Customer Service

*28101* 4600 Electronic Low Energy Operator Installation Instructions 4630 PULL SIDE MOUNT 4640 PUSH SIDE MOUNT. Table of Contents.

4031 Series Door controls

4040XPT Series Door controls

4040XP Series Door controls

1461 Series Door controls

TS93 EMF T/PT/TDE. Surface applied door closer

Electro-Mechanical Swing Operator. Table of Contents

Standard closer offers 3 installation options. - Regular (Pull side) - Top Jamb (Push side) - Parallel Arm (Push side)

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

FIRE/LIFE SAFETY SERIES PRODUCT SELECTION GUIDE

NON-SIZED SIZED HANDED

NON-SIZED SIZED HANDED

LCN 4040SE SERIES FEATURES HINGE (PULL) SIDE MOUNTING

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T*

5600 Series Power Operator Installation and Instruction Manual

Installation Instructions Series 78-B/FHA Hold Open

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

5300 Series 5300 SERIES

LCN 9140 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

*70954* 240V Senior Swing Control Box Installation Instructions CAUTION WARNINGS. Table of Contents

*HINGE (pull) side mount shown

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

4310ME Series. Features E25. Special Templates. Certifications. Cover Fasteners Mounting Arms

LCN 4310ME SERIES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled. closer/holder designed to provide

CONCEALED CLOSER SERIES

ASSA ABLOY Universal Door Closers

Metal, Standard Wood and machine screw pack Top jamb (Push Side) Body Construction. Finishes/Colors/ Powder Coat. Wiring NON-SIZED SIZED

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

LCN 4310ME SERIES FEATURES HINGE (PULL) SIDE MOUNTING. The 4310ME SENTRONIC is a. heavy duty, electrically controlled

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

Allegion LCN Benchmark AU9100 Series

*4110 HCUSH mount shown

NON-SIZED SIZED HANDED

7100SZ Series SafeZone Installation and Instruction Manual

1450 Series. Key Features. LCN quality and value, backed by a 25-year warranty. Medium duty cast aluminum door closer

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

HIGH SECURITY CLOSERS SERIES

4640 shown POWER OPERATOR HOLD-OPEN ACCESSIBILITY* NON-HANDED NON-SIZED

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

D O O R C L O S E R S

Finishes/Colors/ Powder Coat

*HINGE (pull) side mount shown COVER ACCESSIBILITY NON-HANDED NON-SIZED AVB**

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

HIGH SECURITY SERIES

D o o r C l o s e r s

M400 Series Double Locks. Features

* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

Door Controls DOOR CLOSERS

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

CONCEALED CLOSER SERIES

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED

Characteristics for guide rail G195 Height-adjustable by 2 mm for tolerance Concealed fastening screws Installation dimensions: see diagram

High Security Closers Series

Model 2300JL Installation Guide

1000 SERIES SURFACE MOUNTED CLOSERS

LCN 4040 SERIES. CLOSER MOUNTS HINGE (PULL SIDE) (Shown) TOP JAMB (PUSH SIDE) PARALLEL ARM (PUSH SIDE)

Model 2300DL Installation Guide

LCN 4010T SERIES HINGE (PULL) SIDE

The 4040XP is LCN s most durable and flexible heavy duty closer designed for institutional and other demanding high traffic applications.

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

*HINGE (pull) side mount shown

PUSH SIDE M O U N T E D PULL SIDE M O U N T E D D O U B L E LEVER ARM LEVER ARM P D O U B L E LEVER ARM S I N G L E LEVER ARM

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

Closer with traditional styling for low to moderate traffic openings 78-B/F DOOR CLOSER CATALOG

Product Catalog. hardwaresuppliers.com

4310ME Series. Features E25. Special Templates. Grade 1 - ANSI A156.15, UL 10C, ADA, 100 Hour Salt Spray, Meets BAA - Buy American Act, NFPA 101

1000 Series surface mounted closers

ASSA ABLOY DC700. Characteristics of standard guide rail G193 Without protective cover Visible fastening screws

*ININST.1039* 2390 Touchbar

High Security Closers Series

Power drill Center punch Wire stripper

Door Closer Cycle. How to Select the Proper Closer. Things to Consider

Product Catalog Phone: Fax:

LCN Super Smoothie Adjustable Closer Super Smoothie Adjustable Closer

Installation Instructions CAUTION

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

Installation Instructions (07-08) CAUTION

51 Series Door Closers. An ASSA ABLOY Group brand

SAFETY REASONABLE EFFORT. ANY BINDING, SAGGING, LOOSE HINGES, OR DAMAGED HINGES MUST BE REPAIRED BEFORE CONTINUING WITH THIS INSTALLATION!

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

*HINGE (pull) side mount shown

JACKSON CORPORATION Series

KEANE MONROE a member of the record group

MA-5200 Series MA-5300 Series

Transcription:

*15022* 4410ME Series 15022 Door closer with electronic release & Multi-point hold open Installation Instructions 1 Closer Installation 1a Closer Information Closer is handed at the factory. The hand of the closer must match the hand of the door (see the door handing diagram below). Determine the closer mounting template to use - Standard or Flush- Ceiling (see page 4). Refer to the proper template for the entire installation 1b Voltage Voltage supplied to the door frame MUST match voltage of the solenoid. 1c Before beginning this step, determine which type of wiring option will be used, and follow the corresponding instructions: Concealed Wiring: see Figure 3 on page 3. a. Prepare the frame per the proper template on page 4. Be sure all the holes are dimensioned correctly before drilling and tapping. b. Assemble the conduit connector provided to the flexible conduit, then attach to the hole in the mounting plate. c. Secure the mounting plate to the frame with the screws provided. Warning HAZARDOUS VOLTAGE CAN SHOCK AND CAUSE SEVERE INJURY Disconnect power before making any electrical connections or performing maintenance. Surface Wiring: see Figure 4 on page 3. LL NOTE: Remove the knockout in the top of the cover. a. Prepare the frame per the proper template on page 4. Be sure all the holes are dimensioned correctly before drilling and tapping. b. Secure the mounting plate to the frame with the screws provided. c. Attach the surface run Z\x EMT conduit to the hole in the bracket on the mounting plate. Be sure the conduit is securely attached to the bracket. 1d Wiring Connections Make the wiring connections at this time. Connect the two black wires to the input voltage (polarity is not important). The green wire MUST be connected to an earth ground (see Figures 3 & 4 on page 3). 1e Main Place the main arm onto the shaft, approximately 90 to the closer body, and secure with the arm shaft screw. 1f Rod & Shoe Attach the rod and shoe to the door, per the proper template on page 4, with the provided screws. 1g Insert the Rod Open the door partway and insert the rod into the forearm, then close the door. Pull the Main to a right angle (90 ) to the door, insert the arm set screw, and tighten securely. 1h Regulate the Closer Regulate the closer and perform the electrical checkout, as instructed on page 2, before installing the closer cover. HOW TO TELL HAND OF DOOR: LEFT HAND DOOR RIGHT HAND DOOR = 33 ft-lbs 45 N-m 58 N MAXIMUM OPENING FORCE Customer Service 1-877-671-7011 www.allegion.com/us Allegion 2014 Printed in U.S.A. 15022 Rev. 01/14-h

2 Regulation Instructions See Figure 2 on the opposite page for regulating screw location, door control diagram & spring power adjustment 2a Spring Power Adjustment DO NOT ALLOW THE DOOR TO SLAM INTO THE FRAME. The spring power should be adjusted only if more power is needed to close the door. Turning the spring adjustment B\cx Allen Wrench clockwise will increase the spring power. Maximum adjustment is six (6) turns. 2b Regulation A normal closing time from a 90 position is five (5) to seven (7) seconds, equally divided between the MAIN and LATCH SPEED. If adjustments are needed, use a C\cx Allen Wrench. To adjust the MAIN SPEED, turn the regulating screw clockwise to slow the door speed, or counterclockwise to increase the door speed. LATCH SPEED is adjusted the same way. When adjusting the BACKCHECK, use the least amount of force necessary to sufficiently slow the swing of the door.to adjust the closer BACKCHECK, turn the regulating screw clockwise to increase the amount of force, or counterclockwise to reduce the amount of force. DO NOT USE THE ABRUPT BACKCHECK SETTING OR EXPECT THE CLOSER TO ACT AS A STOP! Caution Improper installation or regulation may result in personal injury or property damage. Follow all instructions carefully. For questions, call LCN at 877-671-7011 4 Electrical Data for Door Holder Solenoid 24V AC-DC Nominal +10% - 15% @ 0.075 Amp. Max. 120V AC-DC Nominal +10% - 15% @ 0.030 Amp. Max. 24 V Hold Open Force Adjustment If the door is hard to pull out of the hold open position, adjust as shown. Important The closer leaves the factory set at a maximum holding force. The holding force may be decreased and increased again, but it cannot be increased beyond the original setting. Turn counterclockwise to decrease the holding force + 3 Electrical Checkout After completion of installation & wiring, and with the unit properly powered, perform the following tests: 3a Hold Open the Door With power on, open the door any position and release. The door should remain in the hold-open position within 10. For a bypass model to hold open, the door must be opened beyond the degree of the door swing indicated on the label. 3b Door If the door does not remain in the hold open position, push the on/ off switch. If the door still does not hold open, verify the proper voltage input at the solenoid leads. 3c Power Release Turn the power off. The door should close completely. 3d Manual Release To release manually, pull firmly on the door. The door should close completely. 3e Rechecking the System The system should be checked at regular intervals. It is recommended that steps 3a-3c be repeated every 90 days.

Figure 1 Cover Mounting Bracket For Surface Run Conduit Spring Power Adjust. Hole For Concealed Conduit Connection Assy. Shaft Screw Cover Screws Rod & Shoe Assembly Set Screw Figure 2 Latch Main 1 Backcheck 2 3 Main Latch 6 Turns Max. Backcheck To Increase Closing Power Figure 3 Figure 4 Connect Green Wireto Earth Ground Connect Black Wires to Input Voltage Leads (Polarity Not Important) Connect Black Wires to Input Voltage Leads (Polarity Not Important) Connect Greenwire To Earth Ground

4410 ME HOLD OPEN ANY POINT TO 150 HOLD OPEN ANY POINT TO 170 HOLD OPEN ANY POINT TO 150 HOLD OPEN ANY POINT TO 170! WARNING HAZARDOUS VOLTAGE CAN SHOCK AND CAUSE SEVERE INJURY Disconnect power before making any electrical connections or performing maintenance. NOTES- 1. Voltage supplied to unit must match voltage shown on Sentronic label. 2. Locate closer and shoe from C L of pivot when pivots are used. For use with swing clear hinges, consult factory. 3. Auxiliary stop is recommended. For use with overhead stops, shoe must be lowered to clear holder. 4. Long arm required for opening beyond 160. Reveal not exceed 3 7/8" (5 3/4" FRAME). 5. Maximum stop thickness is 5/8". 6. 7. Electric connector provided by LCN. Reinforcing per ANSI\SDI - 100 is recommended for hollow metal door and frames.

Front 17.00 Back 4.25 Page 1 Page 2 Page 3 Page 4 11.000 11.000 BEGINNING SHEET folded SHEET Additional Notes: Revision History Revision Description: h > Revised artwork 1. None G H J K L M 038791 043228 Material Notes 1. printed two sides 2. printed black 3. tolerance ±.13 4. printed in country may vary 5. drawings not to scale White Paper Edited By Approved By EC Number Release Date D. Myers M. Sasso 043228 01-01-14 Title Creation Date 05-10-10 Created By N/A Software: InDesign CS6 4410ME Series Instruction Sheet Number 15022 Revision h Activity 3899 Hancock Expwy Security, CO 80911 Allegion 2014