Electrically operated spool valve. The manual override is detent and is operated by screw driver.

Similar documents
Series MI-01, MI-02, MI-03

NAMUR Technical details

NAMUR Technical details

Electrically operated poppet valve. The manual override is detent and is operated by screw driver.

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Electrically operated valves Series KM-09, 5/2- and 5/3-way G1/8 680 to 950 Nl/min (0.691 to Cv)

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series KN-05 acc. to NAMUR, 3/2-way G1/4 780 Nl/min (0.792 Cv)

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv)

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

BM-01. Electrically operated valves 3/2-way G 1/8, Nl/min ( Cv) Technical data for series. Order code BM HNR-162

BM-02. Electrically operated valves 3/2-way G 1/4, Nl/min ( Cv) Technical data for series. Order code BM HNR-162

COILS, CONNECTORS, SOLENOID VALVES

Series PD directly operated solenoid valves

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

Series PD directly operated solenoid valves

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

Series P directly operated solenoid valves

3/2-way Solenoid Valve for pneumatics

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

SOLENOID VALVES AND PNEUMATIC VALVES

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Nugget 40, V08 series

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

0322, 0324, Pilot Solenoid Valve, Plastic

Series 581 ISO Pneumatic Directional Control Valves

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

10 mm solenoid valves on manifold with multiconnection D-SUB

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

Valves and Solenoid valves Series 7

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

Valve terminal systems Valve terminal systems Series TC08. Brochure

Valve terminal systems Valve terminal systems Series TC15. Brochure

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Pneumatic Valve 4V100 Series

2/2-way Solenoid Valve with servo diaphragm

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Table of contents. Technical informations > ATEX Page Technical informations Page Mechanically operated valves Page 13-06

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

VALVES ISO 5599/1, SERIES IPV-ISV

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm

C 50 μm filtered air, with or without lubrication spool 10 bar G/18 6,5 G1/4 8,5

3/2-way Solenoid Valve, direct-acting, NC or NO

Valves and Solenoid valves Series E 2/

Pilot-Operated Directional Control Valves Series D3 - D11

series UK Poppet valves pilot and solenoid actuated G 1/8 - G 1/4 - G 1/2 - G 1 DESCRIPTION MATERIALS TECHNICAL DATA Poppet valves series UK

400 SERIES MANIFOLD MOUNT VALVES PENTAIR CLEAN AIR SYSTEMS

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Valve: brass guiding tube plunger and core made by a magnetic stainless steel specially designed for solenoid applications polyester valve body

Direct-acting 3/2 way plunger valve

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Pneumatically actuated valves 3/2 NC become NO when the supply is on connection 3.

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

Solenoid directional valves type DPHI, DPHU

200 SERIES THREADED VALVES PENTAIR CLEAN AIR SYSTEMS

HERION SERIES Indirect solenoid actuated soft seal

Servo-operated 2/2-way solenoid valves Type EV220A

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

VALVES SERIES 70, SOLENOID/PNEUMATIC

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

600/700 SERIES FLANGED VALVES PENTAIR CLEAN AIR SYSTEMS

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Solenoid System FLANGE MOUNTING VERSION

Series 77 & 78. Compact & Modular Valves. solutions. Series 77 - Compact Valves. Series 77 - Sub-D. Series 77 - Fieldbus

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

Complete Range of Movement Solutions

Directional valves Electrically operated CL03 series-ev. Brochure

Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

Solenoid/pneumatic valves, Tiger Classic

Transmitters: Relay Valve VR4151/4152

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

300 SERIES DRESSER NUT VALVES PENTAIR CLEAN AIR SYSTEMS

Control Valve Specifications

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

5/2 and 5/3 Way Valves

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

2/2 Pressure operated valves

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Solenoid directional valves type DPHI and DPHE two stage, ISO 4401 size 10, 16, 25 and 32

COMPACT VALVE - 1/4 Series DS2

97105 Inline. Ordering information. Technical data. Accessories See page 5

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

On-off Valves MS-EE, Inch Series Overview

Solenoid Valve Island Type 3965

Transcription:

Valves > electrically operated valves > Series M-07 Technical details Connection G1/ Nominal size Temperature range Medium Series M-07 page Materials 9 mm -10 C... +70 C Filtered, oil-free and dried compressed air according to ISO 8573-1:010, Class 7::, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 10 C below lowest occurring ambient temperature. Body: Al (anodized), plastic, seals: NBR, inner parts: Al, steel and plastic IP 65 according to EN 6059 Valves in accordance with 01/3/EU (ATEX) available. (Chapter 13) Electrically operated spool valve. The manual override is detent and is operated by screw driver. 3/-way-valves 10 10 10 Please complete: xxx = electrical option M-07-310-HN-xxx 3/-way, single solenoid, air spring return, NC MO-07-310-HN-xxx 3/-way, single solenoid, air spring return, NO M-07-311-HN-xxx 3/-way, single solenoid, mechanical spring return, NC MO-07-311-HN-xxx 3/-way, single solenoid, mechanical spring return, NO ME-07-311-HN-xxx 3/-way, single solenoid, external pilot pressure, mechanical spring return M-07--HN-xxx 3/-way, double solenoid ME-07--HN-xxx 3/-way, double solenoid, external pilot pressure 5/- and 5/3-way-valves 1 1 1 1 1 1 1 1 1 1 1 M-07-510-HN-xxx 5/-way, single solenoid, air spring return M-07-511-HN-xxx 5/-way, single solenoid, mechanical spring return ME-07-511-HN-xxx 5/-way, single solenoid, external pilot pressure, mechanical spring return M-07-50-HN-xxx 5/-way, double solenoid ME-07-50-HN-xxx 5/-way, double solenoid, external pilot pressure M-07-5-HN-xxx 5/3-way, center position closed +1 M-07-53-HN-xxx 5/3-way, center position safety M-07-533-HN-xxx 5/3-way, center position exhausted M-07-53-HN-xxx 5/3-way, center position pressurized Electrical options -xxx Manual override on same side of ports Nominal voltage Power consumption Specifics Plug connection *1 or and 1, 3 or 1, 3 and 5 V DC. W Form B industrial norm -1-11 V DC. W max. 8 bar Form B industrial norm -61-31 V DC. W Form B industrial norm - - V DC.8 W M -O -O V DC. W max. 8 bar Form B industrial norm -6-3 V DC.5 W max. 8 bar M -O6 -O3 V AC 7/ VA Form B industrial norm -5-115 V AC 7/ VA Form B industrial norm -56-6 V AC 7/ VA Form B industrial norm -57-7 * 1 Plug socket not included, suitable plug sockets see page 5. Subject to change 01

Valves > electrically operated valves > Series M-07 Technical data Model-no.: M-07-310 MO-07-310 M-07-311 MO-07-311 ME-07-311 M-07- ME-07- Operating pressure* (bar) 1.5... 10 1.5... 10.5... 10.5... 10 0... 10 1.5... 10 0... 10 Pilot pressure* (bar) 1.5... 10 1.5... 10.5... 10.5... 10.5... 10 1.5... 10 1.5... 10 Flow rate (Nl/min) 1580 1580 1580 1580 1580 1580 1580 Response time (ms) at 6 bar Weight (kg) 0.375 0.375 0.380 0.380 0.50 0.50 0.578 Model-no.: M-07-510 M-07-511 ME-07-511 M-07-50 ME-07-50 Operating pressure* (bar) 1.5... 10.5... 10 0... 10... 10 0... 10 Pilot pressure* (bar) 1.5... 10.5... 10.5... 10... 10... 10 Flow rate (Nl/min) 1580 1580 1580 1580 1580 Response time (ms) at 6 bar Weight (kg) 0.55 0.65 0.5 0.60 0.650 Model-no.: M-07-5 M-07-53 M-07-533 M-07-53 Operating pressure* (bar) 3... 8 3... 8 3... 8 3... 8 Pilot pressure* (bar) 3... 8 3... 8 3... 8 3... 8 Flow rate (Nl/min) 10 80 10 10 Response time (ms) at 6 bar on: 35 off: Weight (kg) 0.60 0.60 0.60 0.60 * max. 8 bar at. W and.5 W Model-no.: M-07-310 MO-07-310 M-07-311 MO-07-311 ME-07-311 M-07- ME-07- Operating pressure* (bar) 1.5... 10 1.5... 10.5... 10.5... 10 0... 10 1.5... 10 0... 10 Pilot pressure* (bar) 1.5... 10 1.5... 10.5... 10.5... 10.5... 10 1.5... 10 1.5... 10 Flow rate (Nl/min) 1580 1580 1580 1580 1580 1580 1580 Response time (ms) at 6 bar Weight (kg) 0.375 0.375 0.380 0.380 0.50 0.50 0.578 Model-no.: M-07-510 M-07-511 ME-07-511 M-07-50 ME-07-50 M-07-5 M-07-533 M-07-53 Operating pressure* (bar) 1.5... 10.5... 10 0... 10... 10 0... 10 3... 10 3... 10 3... 10 Pilot pressure* (bar) 1.5... 10.5... 10.5... 10... 10... 10 3... 10 3... 10 3... 10 Flow rate (Nl/min) 1580 1580 1580 1580 1580 10 10 10 Response time (ms) at 6 bar Weight (kg) 0.55 0.65 0.5 0.60 0.650 0.60 0.60 0.60 Accessories * max. 8 bar at. W and.5 W Plug sockets: page -3 Manifolds: page 0 0 Subject to change

Valves > electrically operated valves > Series M-07 Dimensions M-0-310-HN, M-07-31x-HN, MO-07-31x-HN*, MO-0-310-HN ME-07-31x-HN M-07--HN, ME-07-3 Ø 5.5 3 50 36 73 3 1 113 6 170 189 G1/8 *For the NO version MO-07 the ports 1 and 3 are inverted. M-0-310-HN. M-07-51x-HN, ME-07-511-HN MO-0-310-HN M-07-50-HN, ME-07-50-HN, M-07-53x-HN 15 Ø 5.5 66 50 36 73 5 135 6 191 11 G1/8 1 = pressure inlet, = outlets 3,5 = exhausts 6 = external pilot pressure supply (only at ME-valves) M-07-53-HN Plug socket (not included in scope of delivery) can be repositioned by 180. Solenoid coil can be repositioned by x 90. 0 9 Subject to change 03

Valves > electrically operated valves > accessories > Series M-07 General information The R-11/n manifold is suitable for the M-07 valve series. As well available are blind plates R-11-V for blank stations and mounting brackets R-11-W (pair). Hollow bolts and gaskets are included. The manifold is as well suitable for the pneumatically operated valve series P-07. Dimensions 135 50 73 R-11/n R-11-V G1/ 9 0 R-11-W A SW19 93.3 C B 10 1 1 G 3/8 6 18 6.5 93 M-07-510 M-07-50 8 1 = Pressure inlet Model-no.: A B C Weight (kg) R-11/ 96.6.3 100 0.165 R-11/3 6.9 60.6 1 0.7 R-11/ 157. 90.9 160 0.87 R-11/5 187.5 1. 190 0.39 R-11/6 17.8 151.5 0 0. R-11/8 8.1 181.8 50 0.73 R-11/ 399.6 333.3 00 0.781 0 Subject to change

Valves > electrically operated valves > accessories > Plug sockets Form A according to DIN EN 1751-803 Accessories Contact distance 7 mm 18 mm P + E IP 65 according to EN 6059 requires a profile gasket Model-no.: 8-ST-03 8-ST-11-1 Voltage (AC/DC) 0-50 V V Status indicator no yes Protective circuit no yes (Varistor) Connecting cable without without Wire cross section max. 1.5 mm² max. 1.5 mm² Ø Connecting cable 6-8 mm 6-8 mm Form B according to DIN EN 1751-803 Contact distance mm 10 mm P + E IP 65 according to EN 6059 requires a flat gasket Model-no.: Voltage (AC/DC) Status indicator Protective circuit Connecting cable Wire cross section Ø Connecting cable 0-50 V no no without max. 1.5 mm² 6-8 mm 8-ST-01-G Form B industrial norm Contact distance mm 11 mm P + E IP 65 according to EN 6059 requires a flat gasket M-0, M-05, M-07, M-, KM-09, KM-10, MS-18, KN-05, MN-06, MI-01, MI-0, MI-03 Model-no.: 8-ST-01 8-ST-0-1 8-ST-0-7 8-ST-06-1 8-ST-06-7 8-ST-06-K3-1* 8-ST-06-K3-7* Voltage (AC/DC) 0-50 V 10-50 V 70-50 V V V V V Status indicator no yes yes yes yes yes yes Protective circuit no no no yes (varistor) yes (varistor) yes (varistor) yes (varistor) Connecting cable without without without without without 3 m 3 m Wire cross section max. 1.5 mm² max. 1.5 mm² max. 1.5 mm² max. 1.5 mm² max. 1.5 mm² 3 x 0.75 mm² 3 x 0.75 mm² Ø Connecting cable 6-8 mm 6-8 mm 6-8 mm 6-8 mm 6-8 mm * These plug sockets are fitted with integrated flat gaskets. Subject to change 05

Valves > electrically operated valves > accessories > Plug sockets Dimensions M-0-310-HN, Form A according MO-0-310-HN to DIN EN 1751-803 5.5 6.8 18 1 18 7.7 7.7 Form B according to DIN EN 1751-803 Form B industrial norm 5.5 8.8 10 5.5 8.8 11 1. 1. 5.5 9 8.6 8.5 1.5 8.6 1.5 1.5 06 Subject to change

Valves > electrically operated valves > spare parts > Solenoid coils Form A according to DIN EN 1751-803 mm Spare parts Contact distance 18 mm P + E IP 65 according to EN 6059 with connected plug socket Duty cycle 100 % Temperature range* -0 C... +50 C Voltage tolerance ± 10 % * The max. applicable operating temperature, depends on the temperature specification of the used valve. Model-no.: 3-SP-016-7 3-SP-016-7 3-SP-016-76 3-SP-016-77 Voltage V DC V AC 110/115 V AC V AC/ 110 V DC Power consumption DC.5 W - - 5.3 W Power consumption AC - 8.0 VA 7.6 VA/ 8.6 VA 7.9 VA Specifics Enhanced humidity resistance. Form B according to DIN EN 1751-803 mm Contact distance 10 mm P + E IP 65 according to EN 6059 with connected plug socket Duty cycle 100 % Temperature range* -0 C... +50 C Voltage tolerance ± 10 % * The max. applicable operating temperature, depends on the temperature specification of the used valve. Model-no.: 3-SP-011-G- 3-SP-011-G-7 Voltage V DC V AC Power consumption DC. W - Power consumption AC -.0 VA Subject to change 07

Valves > electrically operated valves > spare parts > Solenoid coils Form B industrial norm Contact distance mm 11 mm P + E Duty cycle 100 % Temperature range* Voltage tolerance ± 10 % IP 65 according to EN 6059 with connected plug socket -0 C... +50 C M-0, M-05, M-07, M-, KM-09, KM-10, MS-18, KN-05, MN-06, MI-01, MI-0, MI-03 * The max. applicable operating temperature, depends on the temperature specification of the used valve. Model-no.: 3-SP-011-1-SP-011-3-SP-011-3-SP-011-6 3-SP-011-7 3-SP-0-3-SP-0-3 Voltage V DC V DC V AC 115 V AC V AC V DC V DC Power consumption DC. W. W - - -. W. W Power consumption AC - - VA VA VA Model-no.: 3-SP-011-1-71-SP-011-1-7 3-SP-011-1-75 3-SP-011-1-77 3-SP-011-1-73 Voltage V DC/ V AC V DC/ 8 V AC 110/115 V AC V AC V DC Power consumption DC.6 W.8 W - -.5 W Power consumption AC 7.1 VA 7.7 VA 6.0 VA/ 7.6 VA 7.9 VA - Specifics Enhanced humidity resistance. M connection mm Contact distance - P IP 65 according to EN 6059 with connected plug socket Duty cycle 100 % Temperature range* -0 C... +50 C Voltage tolerance ± 10 % * The max. applicable operating temperature, depends on the temperature specification of the used valve. Model-no.: 3-SP-011-5-O 3-SP-0-5-O3 Voltage V DC V DC Power consumption DC.8 W.5 W Power consumption AC - - Specifics Mounting on manifold not allowed. With integrated LED and protective circuit. Min. mounting distance for manifold mounting is 0 mm. With integrated LED and protective circuit. 08 Subject to change

Valves > electrically operated valves > spare parts > Solenoid coils Dimensions M-0-310-HN, Form A according MO-0-310-HN to DIN EN 1751-803 Form B according to DIN EN 1751-803 35.5 Ø9.1 Ø9.1 8.5.5 Ø8.1 Ø16 1.5 Ø8.1 Ø16 1.5 Form B industrial norm M connection 8.5 Ø9.1 10 Ø9.1 3.5 Ø8.1 Ø16 1.5 9.5 Ø8.1 Ø16 1.5.5 9.5 Subject to change 09

Valves > electrically operated valves > technical information > Voltage code - HN * - * * * Manual override HN detent HNR detent HNT non-detent 0 Technical information Coil and plug options ATEX GD, encapsulated with casting compound width mm Coil type 3-SP-037 1 with coil and plug according to valve 3 with coil, without plug according to valve 5 without coil no 6 without pilot valve no 7 8 9 with coil, with enhanced humidity resistance, without plug with coil, with enhanced humidity resistance, with plug ATEX GD, intrinsically safe, with plug width mm according to valve according to valve 3-SP-038 A ATEX 3GD, without plug, width mm 3-SP-00 B ATEX 3GD, with plug, width mm 3-SP-00 C ATEX 3GD, without plug, width mm 3-SP-01 D E F G H I J K L M ATEX GD, encapsulated with casting compound width mm with coil, with enhanced humidity resistance, without plug, low temperature version with coil shape B according to DIN EN 1751-803, with plug with coil shape B according to DIN EN 1751-803, without plug with coil shape A according to DIN EN 1751-803, without plug (if not standard) with coil shape A according to DIN EN 1751-803, with plug (if not standard) with coil, with plug with LED and protective circuit with coil, with plug with LED, without protective circuit 3-SP-036 3-SP-060-1 3-SP-011-G 3-SP-011-G 3-SP-016 3-SP-016 according to valve according to valve N with coil with M connection according to valve O P with coil with M connection with LED and protective circuit without connector bridge, without plug according to valve Q with coil with with cable according to valve R with cable up to 1 m length according to valve S T with connector bridge, without plug U ATEX GD, without coil (for coil 3-SP-036) no V W X ATEX GD, Flame proof enclosuresand encapsulated with casting compound ATEX GD / 3GD, without coil (for coil 3-SP-01 and 3-SP-05) ATEX 3GD, without coil (for coil 3-SP-00 in V AC and 115V AC) Y ATEX GD, without coil (for coil 3-SP-038) no Z ATEX GD / 3GD, without coil (for coil 3-SP-00 in V DC and 3-SP-037) 3-SP-05 no no no 0 1 3 5 6 7 Manual override position on side of without indication ports 1/3/(5) DC ports 1/3/(5) AC ports 1/3/(5) DC, low power consumption ports 1/3/(5) DC ports /() AC ports /() DC, low power consumption ports /() without indication ports /() 0 Voltage without indication 1 V V 3 V 8 V 5 110 V 6 115 V 7 V 8 0 V 9 A B C D E F V 6 V 8 V 61 V 36 V 9 V Not all options are suitable for all valve series 10 Subject to change