GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

Similar documents
YFC. Limit switch. Ex d. 24 operating head types

PY, SPY; FSQC, FP; EPC; AP

Junction boxes for control, monitoring and control panel Ex tb

CCAI, CCAIF, CCAIF..H

M-0. M-0... series control, monitoring and signalling devices. Ex e

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

FHL. Ex d. Body in aluminium

EWE. Ex de. Cooling fins

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

EWE. Cooling fins. Ex de

EVE. Silicon gasket. Ex de

EXEL-L. Detail of the internal side. Transparent polycarbonate

P, I, A. Command and control stations Ex e

SLEE. - Suitable for high (+55 C) and low (-50 C) temperatures - Elevated degree of protection IP67 - IIB + H2 marking (hydrogen) - Zones 1, 2, 21, 22

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

CTB. Ex e. Captive screws B.67. Detail of TIG welding of walls. Earth stud with cable anti-rotation bracket

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

ExBin-P Pressure switches 5 Pa Pa

L-3000, L-5, L-5R. - High efficiency - Smart energy saving - IP67 protection rating - Exceptional ergonomic design - Zone 0, 1, 2 L-5R L-5 L-3000

Emergency Light Fitting for Fluorescent Lamps Series 6009

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Linear Luminaire with LED Series EXLUX 6402/2

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Floodlight LED Series 6125

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

Sensor boxes SRBE Key features and product range overview

Compact Sheet-Steel Light Fittings Series 6114/1

Floodlight LED Series 6525

Terminal Boxes in Stainless Steel SLS**.T

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

Floodlight Series 6121

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

New products Ex Equipment 2015

LED Linear Luminaire Series EXLUX 6402

Solenoid coils VACF Type codes

Terminal Boxes Series 8125

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

ADVANCE- GRP[ GD] S ERIES OP TIMA- EX[ GD] S ERIES

Compact Sheet-steel Emergency Light Fitting Series 6118/1

VALIADIS S.A. HELLENIC MOTORS

PRE Series 63 Amp Plugs and Sockets Increased Safety

Floodlight LED Series 6525

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

ATX PRE Series 63 Amp Plugs and Sockets Increased Safety

Plug and Socket Devices SolConeX 16 A Series 8570

Panelboards & Motor Starters

Thermocouple For additional thermowell Model TC10-B

Position Switches Series 8074/2

OPERATING INSTRUCTIONS

ATX DPD Series Distribution Panelboards Flameproof

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Operating Instructions

Ex m Solenoid Operator Type 0519

A good connection. International approvals.

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Compact pressure switch Model PCS

Position Switches Series 8060/2

EX-D ENCLOSURES AND DISTRIBUTIONS

Glass Reinforced Polyester Enclosures

ATX PRE Series 125 Amp Plugs and Sockets Increased Safety

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

I Ex-safety switches I

Junction box for EKL light

Operating Instructions

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Compact differential pressure switch Models DC, DCC

COMBUSTION AND ENERGY

SERIES 54 Inductive Proximity Sensor

Mini pressure switch Stainless steel switch enclosure Model PXS

Position Switches Series 8070/2

Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

Flameproof Enclosures

Transcription:

Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2 LED indicators Polyester coating RAL7035 Control lever 8m connection cable Connection pliers F.1 ED.2018

GRD-4200 Electronic earthing system Ex d The GRD-4200 series electronic earthing system ensures grounding of tankers and tank trucks during the transfer of flammable liquids, preventing the formation of electrostatic charges. During the entire loading and unloading phase, the device checks that the equipotentiality of the earthing system is maintained. In fact, the electronic system is equipped with a protection circuit that checks the resistance value and compares it to the set parameter and, if this value falls within the preset range, closes the electrical circuit between the two systems that are equipotential. Vice versa, it removes the operating consent from the loading pump and closes the loading valve. The GRD-4200 electronic earthing system has obtained SIL (Safety Integrity Level) Level 2 certification in compliance with IEC-61508 and EN-50495 standards, which guarantees that the system is able to perform its safety function. Cortem Group applies a tamper-evident holographic security label to its products, complete with a unique authentication numeric code, to combat the illegal sale of imitations and counterfeits, as well as guarantee the authenticity of its products. Failure to observe international standards creates serious risks for the environment and, above all, for the personnel who work with the systems on a daily basis. Sectors of application: Petroleum refineries Chemical and petrochemical Onshore Offshore Petroleum load-agribusinesing/unloading pontoons Fuel storage 100% produced by Cortem CERTIFICATION DATA Classification: Group II Category 2GD Installation: EN 60079.14 zone 1 - zone 2 (Gas) zone 21 - zone 22 (Dust) Marking: II 2(1) G - Ex d [ia Ga] ia IIB T6 Gb Certificate: ATEX CESI 04 ATEX 129 II 2(1) D - Ex tb [ia Da] ia IIIC T85 C Db Standards: Temperature class: Ambient Temperature: Degree of protection: IEC Ex IECEx CES 14.0035X For all IEC Ex certification data, download the certificate from www.cortemgroup.com CENELEC EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-11: 2012, EN 60079-31:2009 and the European Directive 2014/34/UE. IEC 60079-0: 2011, IEC 60079-1: 2007, IEC 60079-11: 2011, IEC 60079-31: 2008 RoHS Directive 2002/95/EC. 85 C (T6) -20 C +55 C IP66 A QR reader is required to access the information contained in the QRCode. Centre the QR code in the frame of your Smartphone camera. Your Smartphone will open the corresponding address. ATEX Certificate IECEx Certificate Use and maintenance instructions ED.2018 F.2

Ex d GRD-4200 Electronic earthing system MECHANICAL FEATURES Body and lid: Gasket: Certificate label: Screws, bolts and nuts: Earthing screw: Fastening brackets: Lever on lid: Waring lights: Coating: Inputs: Cable gland: Cable: Pliers: Bracket for pliers: Low copper content aluminium alloy Acid, hydrocarbon and high temperature resistant silicone positioned between the body and the lid Riveted aluminium on lid Stainless steel Stainless steel M6. Stainless steel M6. Inside and outside the body and on the lid, complete with antirotation brackets Electrolytically galvanized steel In coated aluminium Impact and UV resistant polycarbonate Polyester RAL 7035 (Light grey) : The STANDARD of the aluminium alloy used by Cortem has passed the tests required by standards EN60068-2-30 (hot-humid cycles) and EN60068-2-11 (salt fog test) 2 3/4 fittings. Complete with a PLG2G plug For non-armored cable, internally sealed, thread Ø 3/4 ISO7/1 Yellow with trim in rubber resistant to oil and chemical substances. Suitable for extremely high mechanical stresses. Length 8 m. Bipolar, casting with aluminium with handles in neoprene, jaws with steel tips, auto-releasing. 16 mm opening. In stainless steel. ELECTRICAL FEATURES Rated voltage: Rated frequency: 230 Vca o 110 Vac o 24 Vac dc max. 50/60 Hz GRD-4200 Status: Block Consent GRD-4200/110 Status: Block Consent Current draw: 12 ma 24 ma Current draw: 22 ma 45 ma Power: 1.64 W 4.32 W Power: 1.52 W 4.18 W Power factor: 0.57 0.82 Power factor: 0.62 0.84 ACCESSORIES UPON REQUEST / SPECIAL REQUESTS GRD-4200/24 Status: Block Consent Voltage: 24 Vac 24 Vdc 24 Vac 24 Vdc Current draw: 64 ma 24 ma 64 ma 24 ma Power: 1.64 W 4.32 W 1.64 W 4.32 W Power factor: 0.57 0.82 0.57 0.82 Cable gland Cable reel Pliers PMT-B2 F.3 ED.2018

GRD-4200 Electronic earthing system Ex d DIMENSIONAL DRAWING The cable reel is a suitable accessory for the GRD- 4200 earthing system. The cable reel in reinforced die-cast aluminium is resistant to impact, temperature peaks and atmospheric agents. Dimensions in mm SELECTION TABLE Codice Code Alimentazione Power supply Frequenza Rated frequency nominale Weight Peso Kg GRD-4200 230 Vac 50-60 Hz 20 GRD-4200/110 110 Vac 50-60 Hz 20 GRD-4200/24 24 Vac dc 0 / 50-60 Hz 20 Detail of connection pliers ED.2018 F.4

Ex d GRD-4200 Accessories upon request and spare parts ILLUSTRATION DESCRIPTION MODEL CODE LEGEND Special switch GRD... SEA10X2/12EZ16R GRD-4200 LC-4200S Monitoring logic GRD-4200/110 LC-4200S/110 GRD-4200/24 LC-4200S/24 Zener barrier GRD... BZ-4200 Earthing pliers GRD... PZCC-4209 Yellow cable Length: 8 metres GRD... NSSHOU-02X2,5 Barrier cable gland GRD... FB2BK/3 ACCESSORIO F.5 ED.2018

GRD-4200 Electronic earthing system Ex d WIRING DIAGRAM Internal view GRD-4200 ED.2018 F.6