W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

Similar documents
W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

COMBINATION CIRCUIT BREAKERS RCBO

Residual current devices

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

and other modular devices for low voltage installation

Modular contactor for installation into distribution boards

DSE201 Compact design with enhanced protection

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

W Datasheet: DIN Rail Contactors, series AMPARO

Residual current circuit breakers with conditional shortcircuit

BETA Switching Switches and Light Indicators

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

max pole for t=15 ms

MS25, MST25, MS20, MST20

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Technical Data Accessories MCBs Ex9B.

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Miniature Circuit-Breakers (MCBs)

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

3VU13, 3VU16 Circuit-Breakers

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

MS25, MST25, MS20, MST20

Low Voltage A GE Power Controls Company. General catalogue

Btdin RCBO 6000A up to 63A (2P)

Control Circuit Protection

3NP1 Fuse Switch Disconnectors up to 630 A

MS General Information Extended Product Type: MS

ABB STOTZ-KONTAKT GmbH

TX³ RCCBs 2P up to 100 A

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

For Info: Phone: Fax:

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Electronic overload relays EF205 and EF370

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DX³ RCCBs - ID 4P up to 100 A

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Miniature Circuit-Breakers (MCBs)

RESIDUAL CURRENT CIRCUIT BREAKER

CA Z-EN Overload relays, CT-operated overload relays

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

SIRIUS 3RU2 Thermal Overload Relays

Protection Equipment

DX³ 4-pole RCBO 6000 A/10 ka

cor Long Run Experience

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

NH DIN Dual Indication Fuse Links

INNOZED D0 fuse-bases with touch protection

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left


Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Technical data. Miniature Circuit Breakers. System pro M. System pro M

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Technical data for manual motor starters Type MS325

R.C.B.O. SP / 1 module

Thermal overload relay TF65 and TF96

Thermal overload relay TF140DU and TF140DU-V1000

Electronic overload relay EF65, EF96 and EF146

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Magnetic and Hydraulic-Magnetic Circuit Breaker

MC FRAME SIZE 1 / UP TO 160A

Control switch/load disconnect switch Series 8008

Thermal Overcurrent Circuit Breaker 3120-F...

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Application Mini Contactors for Motors and Resistive Loads

LINOCUR Size D02 63A 230VAC/440VAC

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

INNOZED D0 fuse-bases with touch protection

Overloadrelay,10-16A,1N/O+1N/C. Articleno

abb.ch ABB Switzerland Ltd. Low Voltage Products Fulachstrasse 150 CH-8201 Schaffhausen Telefon +41 (0) Telefax +41 (0)

Thermal Overcurrent Circuit Breaker 3120-F...

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

4 - Miniature controls

Components for EEx e Panels

Thermal Overcurrent Circuit Breaker 3120-F...

The effective choice The benefits of a product with the highest quality standards

1489-M Circuit Breakers

DPX earth leakage DPX 3 -I earth leakage

Transcription:

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B W SCHRACK-INFO All-current sensitive RCCB ( type B, B+ and Bfq) B+ types also meet the requirements of superior fire-protection systems No monthly test required Residual current indicator with 3 LED Warning before the RCD trips in case of leakage currents with an integrated auxiliary contact 4-pole types can also be used as 2-pole devices for photovoltaic applications Real contact position indicator Fault current tripping indicator Automatic re-setting possible W Technical datas Standards Types B and Bfq acc. to IEC/EN 61008, IEC/EN 62423 Type B+ acc. to VDE 0664-400 Type G/B and G/B+ additional acc. to ÖVE E 8601 Poles 4-pole Type B, B+, Bfq Sensitivity Alternating, pulsed and direct currents Rated current I n 25A, 40A, 63A Rated voltage U n 240/415 VAC, 50 Hz PAGE 1/11

Operation voltage electronic 50 456 VAC Voltage range test circuit 30mA 196-264V AC Rated tripping current I Δn 300mA 196-456V AC 30mA, 300mA Tripping time Type G IΔn 10ms and 300ms No tripping residual current I Δno Rated insulation voltage U i Rated impulse withstand voltage U imp Rated short circuit capacity I cn 2 xiδn 10ms and 150ms 5 x IΔn 10ms and 40ms Type S IΔn 130ms and 500ms 2 xiδn 60ms and 200ms 5 x IΔn 50ms and 150ms 0,5 IΔn 440V 4kV (1.2/50µs) 10kA Bemessungsschaltvermögen I m 25A - type 500A 40A - type 500A 63A - type 630A Bemessungsfehlerschaltvermögen I m 25A - type 500A Peak withstand current 40A - type 63A - type Type G/B, G/B+ and G/Bfq Type S/B, S/B+ and S/Bfq 500A 630A 3kA (8/20µs) surge current proof typ. 5kA (8/20µs) selective + surge current proof Electrical isolation > 4mm contact space Maximum back-up fuse short circuit protection I n = 25A 63A gg/gl I n = 40A 63A gg/gl I n = 63A 63A gg/gl Maximum back-up fuse overload protection I n = 25A 63A gg/gl Power loss I n = 40A I n = 63A 63A gg/gl 63A gg/gl according to the following diagram PAGE 2/11

Prevents nuisance tripping caused by switching electronic light: delayed G,S 30mA delayed G,S 100mA with commercially available ballast according to the manufacturer max. 30 EVG each phase, max. 90 each RCCB delayed G,S with commercially available ballast according to the manufacturer max. 90 EVG each phase Endurance electrical components > 4,000 operating cycles mechanical components > 20,000 operating cycles Tripping temperature Storage- and transport temperature Resistance to climatic conditions Dimensions Frame size 45mm Mounting Device height Device width Polution degree 2 Degree of protection Upper and lower terminals Terminal protection Terminal capacity Terminal screw Terminal torque Busbar thickness Terminal capacity warning contact Contact position indicator Tripping indicator -25 C to +40 C -35 C to +60 C 25-55 C/90-95% relative humidity acc. to IEC 60068-2 80mm 70mm (4MW) quick fastening with 2 lock-in positions on DIN rail IEC/EN 60715 IP20 built-in IP40 open mouthed/lift terminals finger and hand touch safe, BGV A3, ÖVE- EN 6 1.5-35mm² single wire 2 x 16mm² multi wire M5 (Pozidriv PZ2) 2-2.4Nm 0.8-2mm 0.25-1.5 mm2 (plug in terminals) red / green white / blue PAGE 3/11

W Tripping diagram PAGE 4/11

W Power loss Order no. Pole I N I Δn Type Power loss BC822103-- 4-pole 25 A 30 ma G/B 4,6 W BC822130-- 4-pole 25 A 300 ma G/B 4,6 W BC824103-- 4-pole 40 A 30 ma G/B 6,2 W BC824130-- 4-pole 40 A 300 ma G/B 6,2 W BC826103-- 4-pole 63 A 30 ma G/B 10 W BC826130-- 4-pole 63 A 300 ma G/B 10 W BC832103-- 4-pole 25 A 30 ma G/B+ 4,6 W BC832130-- 4-pole 25 A 300 ma G/B+ 4,6 W BC834103-- 4-pole 40 A 30 ma G/B+ 6,2 W BC834130-- 4-pole 40 A 300 ma G/B+ 6,2 W BC836103-- 4-pole 63 A 30 ma G/B+ 10 W BC836130-- 4-pole 63 A 300 ma G/B+ 10 W BC852130-- 4-pole 25 A 300 ma S/B 4,6 W BC854130-- 4-pole 40 A 300 ma S/B 6,2 W BC856130-- 4-pole 63 A 300 ma S/B 10 W BC862130-- 4-pole 25 A 300 ma S/Bfq 4,6 W BC864130-- 4-pole 40 A 300 ma S/Bfq 6,2 W BC866130-- 4-pole 63 A 300 ma S/Bfq 10 W BC872103-- 4-pole 25 A 30 ma G/Bfq 5 W BC872130-- 4-pole 25 A 300 ma G/Bfq 4,6 W BC874103-- 4-pole 40 A 30 ma G/Bfq 7 W BC874130-- 4-pole 40 A 300 ma G/Bfq 6,2 W BC876103-- 4-pole 63 A 30 ma G/Bfq 11 W BC876130-- 4-pole 63 A 300 ma G/Bfq 10 W BC882130-- 4-pole 25 A 300 ma S/B+ 4,6 W BC884130-- 4-pole 40 A 300 ma S/B+ 6,2 W BC886130-- 4-pole 63 A 300 ma S/B+ 10 W PAGE 5/11

W Wiring diagram W LED signal and auxiliary contact PAGE 6/11

W Test Circuit W Instruction RCCB must be tested by PUSHING the TEST BUTTON 1x yearly. A test is further needed if red and yellow LED are on together. The switch must trip immediately. The testing is the responsibility of the user! The yearly test interval is only valid for residential and similar applications. Under all other conditions (e.g. damply or dusty environment), it is recommended to test in shorter intervals. PAGE 7/11

W Possible connections PAGE 8/11

W Dimensions W Articles Residual current circuit breaker, series PRIORI, 10kA, Typ B, G, 30mA Residual current circuit breaker 25A, 4-p, 30mA, type B, G Residual current circuit breaker 40A, 4-p, 30mA, type B, G Residual current circuit breaker 63A, 4-p, 30mA, type B, G BC822103-- BC824103-- BC826103-- Residual current circuit breaker, series PRIORI, 10kA, Typ B, G, 300mA Residual current circuit breaker 25A, 4-p, 300mA, type B, G Residual current circuit breaker 40A, 4-p, 300mA, type B, G Residual current circuit breaker 63A, 4-p, 300mA, type B, G BC822130-- BC824130-- BC826130-- PAGE 9/11

Residual current circuit breaker, series PRIORI, 10kA, Typ B, S, 300mA Residual current circuit breaker 25A, 4-p, 300mA, type B, S Residual current circuit breaker 40A, 4-p, 300mA, type B, S Residual current circuit breaker 63A, 4-p, 300mA, type B, S BC852130-- BC854130-- BC856130-- Residual current circuit breaker, series PRIORI, 10kA, Typ B+, G, 30mA Residual current circuit breaker 25A, 4-p, 30mA, type B+, G Residual current circuit breaker 40A, 4-p, 30mA, type B+, G Residual current circuit breaker 63A, 4-p, 30mA, type B+, G BC832103-- BC834103-- BC836103-- Residual current circuit breaker, series PRIORI, 10kA, Typ B+, G, 300mA Residual current circuit breaker 25A, 4-p, 300mA, type B+, G Residual current circuit breaker 40A, 4-p, 300mA, type B+, G Residual current circuit breaker 63A, 4-p, 300mA, type B+, G BC832130-- BC834130-- BC836130-- Residual current circuit breaker, series PRIORI, 10kA, Typ B+, S, 300mA Residual current circuit breaker 25A, 4-p, 300mA, type B+, S Residual current circuit breaker 40A, 4-p, 300mA, type B+, S Residual current circuit breaker 63A, 4-p, 300mA, type B+, S BC882130-- BC884130-- BC886130-- Residual current circuit breaker, series PRIORI, 10kA, Typ B-fq B for frequncy converters, G, 30mA Residual current circuit breaker 25A, 4-p, 30mA,type B-fq,G Residual current circuit breaker 40A, 4-p, 30mA,type B-fq,G Residual current circuit breaker 63A, 4-p, 30mA,type B-fq,G BC872103-- BC874103-- BC876103-- PAGE 10/11

Residual current circuit breaker, series PRIORI, 10kA, Typ B-fq B for frequncy converters, G, 300mA Residual current circuit breaker 25A, 4-p, 300mA,type B-fq,G Residual current circuit breaker 40A, 4-p, 300mA,type B-fq,G Residual current circuit breaker 63A, 4-p, 300mA,type B-fq,G BC872130-- BC874130-- BC876130-- Residual current circuit breaker, series PRIORI, 10kA, Typ B-fq B for frequncy converters, S, 300mA Residual current circuit breaker 25A, 4-p, 300mA,type B-fq,S Residual current circuit breaker 40A, 4-p, 300mA,type B-fq,S Residual current circuit breaker 63A, 4-p, 300mA,type B-fq,S BC862130-- BC864130-- BC866130-- PAGE 11/11