Electrical Options Booklet. Table of Contents

Similar documents
*ININST.1002* 1690 Touchbar. Index:

OPTIONAL EQUIPMENT EL WIRING. If other 873 logic board, refer to Von Duprin instructions Solenoid

*ININST.1039* 2390 Touchbar

* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION

9827/9927 Surface mounted vertical rod device. 9827/9927 Surface mounted vertical rod device. Specifications Device functions

Recessed. Touch bar exit devices

98/99 Dogging options

33A/35A Series Exit Devices

33A/35A Series. Exit devices

4500 Series Electric Exit Devices Request to Exit (RX) Installation Instruction Grade 1 I-ED00368

33A/35A Series. Exit devices

Dor-O-Matic Exit Devices

KAWNEER 1686 EL CONCEALED EXIT DEVICE

33A/35A Series. Exit devices

33A/35ATM. Series. Exit Devices

9700/F9700 SERIES RIM EXIT DEVICE

Recessed. Exit Device Series

*D-1015* D PARTS CHECK F-XX-V & XX-V EXIT DEVICES INSTALLATION INSTRUCTIONS. Customer Service

Adams rite. Exit Devices & parts exit devices series exit device parts

9849/9949 Concealed Vertical Cable Device

Motorized Electric Latch Retraction

98/99 Series. Exit devices

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

ABS-AMERICAN BUILDING SUPPLY, INC. Von Duprin

22 Series. Exit device

22 Series. Exit device

98/99 Series. Exit devices

22 Series. Exit device

22 Series. Exit device

98/99 Series Rim Exit Devices

Door control and security hardware

Senior Swing Control Box. Table of Contents

Endcap P/N: Pushpad Wrap P/N: X (3-0) P/N: X (4-0)

Standard Plastic Template P/N: (3-0) P/N: (4-0)

98/99 Series. Exit devices

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

The following changes were made to the Von Duprin Price Book 3 Rev 10/15:

22 Series Rim Exit Device. Service manual

SmartLock Accessories

98/99 Series Exit Devices

VON DUPRIN 2720 TOBEY DRIVE INDIANAPOLIS, IN CERTIFIED EXIT DEVICES

33A/35A Series Rim Exit Device

2227 Series Vertical Rod Exit Device. Service manual

PARTS MANUAL 98/99 SERIES RIM EXIT DEVICES. May RIM 98 RIM PM9899_G VD-GN Copyright 2013 Ingersoll Rand

98/99 Series. Exit device

Spectra Class. N6000 Series Exit Devices SECURITY DOOR CONTROLS. N6100 Rim Mount Exit Device. N6200 Surface Vertical Rod Exit Device.

TABLE OF CONTENTS StrikeForce Electric Strikes MAX HOLD Electromagnetic Locks Electrical Accessories Additional Information

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

98/99TM. Series. Exit Devices

1 of 6. Installation Instructions. ED3200/ED3200A Series Rim Exit Device ASSA ABLOY. Plug FM362 (05/15) Inactive Case. Chassis. Inactive Case.

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

KAWNEER 1686 CONCEALED EXIT DEVICE

22 Series Exit Devices

VLP-UL-KIT INSTALLATION INSTRUCTIONS. The VLP-UL-KIT for 36 or 48 is a field installable solenoid latch pullback for the Von Duprin 33/35 &

I-BFV.KIT Butterfly Valve Gear Operator Replacement

INSTALLATION INSTRUCTIONS MODEL 1550K-VD ELR FIELD INSTALLABLE KIT

98/9947, 98/9949, & 98/9950 Series Exit Devices

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ADDITIONAL INFORMATION

ADAMS RITE. ADAMS RITE MANUFACTURING COMPANY Sliding Hardware/Exit Devices Series Turns

55 Series Exit devices

PARTS MANUAL 33A/35A SERIES RIM EXIT DEVICES JUNE A RIM 35A RIM. PM33A35A_Rim_B VD Copyright 2005 Ingersoll-Rand. All rights reserved.

INSTALLATION INSTRUCTIONS CRL JACKSON 2085E

3327A/3527A Series Exit Device

PARTS MANUAL 98/9927 SERIES EXIT DEVICES MAY 2013 PM989927_G VD-GN Copyright 2013 Ingersoll Rand

ADDITIONAL INFORMATION

PARTS MANUAL 98/9947 & 98/9949 SERIES EXIT DEVICES OCTOBER / /9949 VD-GN Ingersoll Rand Rev.

Spectra Class - Specification Grade Exit Devices for superior Architectural Style & Performance

II E INSTALLATION INSTRUCTIONS MODEL 1550K-VD ELR FIELD INSTALLABLE KIT

ED5470 Panic-Listed Surface Vertical Rod Exit Device ED5470B 1-1/2 Hour Fire-Listed Surface Vertical Rod Exit Device

PD18-RIM INSTALLATION INSTRUCTIONS

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

PARTS MANUAL 3327A/3527A SERIES EXIT DEVICES JUNE A SHOWN. PM3327A3527A_b VD Copyright 2005 Ingersoll-Rand. All rights reserved.

22 Series Exit Devices

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

DOOR CONTROL AND SECURITY HARDWARE

Precision List Prices

PRICE LIST. Table of Contents

2904 Power Supply Installation Instructions I-EA00041

* * Maintenance Kit

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

99 Series Exit devices

Chexit/RCM/DE5300. Chexit/RCM/DE5300 Service Parts. Chexit Field Wiring Cable. DE5300/RCM Field Wiring Cable. Table of Contents

55 Series Exit Devices. Service manual

PD10-M-RIM INSTALLATION INSTRUCTIONS. The PD10-M-RIM is a storefront grade 1 exit device equipped with motor drive latch retraction.

9700FL SERIES PANIC LATCH

TS93 EMF T/PT/TDE. Surface applied door closer

GENSET CONTROL MODULE A121A / A241A

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

8500 Narrow Design Rim Exit Device 80 Series

MA Series. Mortise Lockset Functions. MA101 FO1 Passage Latchset Latchbolt by knobs/levers at all times.

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

D3375 SERIES INSET EXIT DEVICE HARDWARE METAL DOOR OPERATIONAL HARDWARE SPECIFICATIONS FEATURES. D3375 Series Certifications

Concealed Vertical Rod Features

8800 Rim Exit Device 80 Series

Vehicle Security System

5000 & F5000 Rim Type Panic And Fire Exit Devices 5000V & F5000V Vertical Rod Panic And Fire Exit Devices ANSI A156.3, Grade 2

PARTS MANUAL 3327A/3527A SERIES EXIT DEVICES FEBRUARY A SHOWN. PM3327A3527A_d VD Copyright 2013 Ingersoll Rand

IMPORTANT SAFEGUARDS

5/8" Radius Corner Hinges

Transcription:

*24228413* 24228413 Electrical Options Booklet Table of Contents EL Wiring... EL Troubleshooting... SD/EL 98/99 Cylinder Dogging... SS Wiring... 330, 350, RX-330 and RX-350 Push Bar Trim Mechanical Installation... RX or RX-LC/S1 Switch Wiring... LX or LX-LC Switch Wiring... QEL Wiring & Configuration... QEL Troubleshooting... 2-3 3-5 6 7 8-9 10 11 12-14 15-16

EL Wiring (page 1 of 2)! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board Tools for Installation 1 Drill Wire Access Hole ⁵ ₈" Drill Bit ⁵ ₁₆" Drill ⁵ ₈" dia. access hole through device side of door. 2 Route Two Wires from EL Exit Device to Power Supply Voltage: Current: EL Electrical Load 24 VDC 16 A inrush (0.3 sec.) 0.25 A holding PS914 power supply with 900-2RS or 900-4RL option board installed EL Exit Device 2 EL device used with EPT or Door Loop Electric Hinge/Pivot Distance (one way) 200' or less 0-100' 150' or less 0-75' Wire Gauge 12AWG required 14AWG permitted 12AWG required 14AWG permitted EPT shown. A door loop or electric hinge/pivot may also be used.

EL Wiring (page 2 of 2) 3 Review LED Functions (For devices purchased after 8/15/12) Normal Operation LED will flash "ON" briefly when +24V DC is applied. This is when potted module is operational and power is being applied to the exit device. LED then goes into a steady "OFF" state and holds there, even with +24V continuing to be applied to the module. Fault Condition LED will turn "ON" and remain illuminated when over-voltage is detected. The potted module will remain in this state until power is removed from the module. NOTE: Input voltage greater than 30V will cause an over-voltage condition. LED Potted Module 4 Check EL Device Operation 4 Activate input and verify that EL device operates properly. Solenoid should retract latch bolt(s). If device does not operate properly, see EL Troubleshooting section. EL Troubleshooting (page 1 of 3) A If the motor fails to retract the latch bolt when power is applied, recheck wiring for proper connections. If motor retracts latch bolt momentarily but will not remain in energized position: 1. Check wiring for proper connections, gauge, and distances. 2. Make sure PS914-2RS or PS914-4RL power supply is installed. 3. Check for latch bolt binding caused by improper strike installation, warped door, etc. 4. If device still does not function properly, continue to Section B. 3

EL Troubleshooting (page 2 of 3) B Check For Proper Function 33A/35A Rim 33A/3527A 33A/3547A 98/99 Rim 98/9927 98/9947 98/9947WDC 98/9957 98/9975 33/3549A 98/9949 98/9949WDC 1. Make sure device is not dogged for SD/HD-EL. 2. Depress pushbar and make sure latch bolt retracts and extends fully (see Figure 1). If latch bolt does not retract or extend fully, adjustment may be required per the device installation instructions. 3. Electrically energize solenoid and hold. 4. Check latch bolt(s) for full retraction (must clear strike, see Figure 1). 5. Release solenoid and check latch bolt extension (see Figure 1) 6. Continue to Section C if device does not function electrically. 33A/35A Rim, 98/99 Rim, 98/9957 extended retracted ³ ₄" Flush within ¹ ₁₆" 1. Make sure device is not dogged for SD/HD-EL. 2. Using a ruler, locate the extended position of the bell crank (see Figure 2). 3. Electrically energize solenoid and hold. 4. Check bell crank travel. Bell crank must be a minimum of ³ ₈" from extended position and must not run out of travel (see Figure 2). 5. Continue to Section C if bell crank travel is too short or long. 33A/3527A, 98/9927, 98/9957 deadlocked (will not push in) stays retracted Release trigger extended 33/3549A bell crank ³ ₈" 33A/3547A, 98/9947, 98/9947WDC deadlocked (will not push in) extended with door closed ⁵ ₈" 98/9975 extended ³ ₄" ³ ₁₆" with door open Flush within ¹ ₁₆" retracted retracted Flush within ¹ ₁₆" 1 98/9949, 98/9949WDC bell crank 1 ³ ₈" 1 1 4 Figure 1 Figure 2

EL Troubleshooting (page 3 of 3) C Determine if Dogging Rod Adjustment is Too Long or Short Device 33A/35A Rim 33A/3527A 33A/3547A 98/99 Rim 98/9927 98/9947 98/9947WDC 98/9975 1. The dogging rod adjustment is too long if latch bolt does not retract and clear strike (see Section D for adjustment). 2. The dogging rod adjustment is too short if latch bolt does not fully extend or latch bolt fully retracts but solenoid releases while energized (see Section D for adjustment). 33/3549A 98/9949 98/9949WDC 1. The dogging rod adjustment is too long if bell crank moves less than ³ ₈" (see Section D for adjustment). 2. The dogging rod adjustment is too short if bell crank runs out of travel (see Section D for adjustment). 1. The dogging rod adjustment is too long if bell crank pin moves less than ³ ₈" (see Section D for adjustment). 2. The dogging rod adjustment is too short if bell crank pin bottoms out on the end of the slot (see Section D for adjustment). D Adjust Solenoid Plunger if Required (See Figure 4) 1. Remove end cap and dogging cover. 2. Loosen cap screw with ³ ₃₂" hex key. 3. Hold plunger so it does not rotate. 4. Turn threaded bushing in or out to see 8 to 10 threads showing so plunger just bottoms in solenoid housing and latch bolt is fully retracted. 5. Tighten cap screw. Note: Cap screw must be tightened against flat on threaded bushing. Apply a few drops of Loc-Tite 222 to threads of cap screw. 6. Replace dogging cover and end cap. 7. Return to Section B to check for proper function. 1 2 6 4 3 5 dogging rod Figure 4 5

SD/EL 98/99 Cylinder Dogging 1. Obtain a 1¹ ₄" mortise cylinder. 2. Make sure cylinder cam is in position shown with key removed (Figure A). If not, remove key, remove cam, and reinstall in position shown (Figure B). Figure A Figure B RHR DEVICE SHOWN 3. Remove center case cover from device. 4. Orient cylinder as shown at right and insert cylinder into bracket. 5. Tighten bracket set screw with a ¹ ₁₆" hex wrench. If you cannot reach bracket set screw with wrench, remove bracket from center case, install cylinder in bracket, tighten bracket set screw, and reinstall bracket in center case. 6. Install center case cover. To dog RHR device, depress pushbar, insert key, and turn key 180 degrees counterclockwise. To dog LHR device, turn key clockwise. Bracket set screw Bracket To undog RHR device, insert key and turn key 180 degrees clockwise. To undog LHR device, turn key counterclockwise. 6 RHR Top

SS Wiring Applies to all SS33/35, SS33A/35A, & SS98/99 series exit devices switch (see Note 1) NC C NO Yellow Red Blue Yellow Red Blue Cable Cylinder switch (see Note 2) NC C NO Violet White Gray Black White Green Notes: 1. The latch bolt switch is actuated whenever the touchbar is depressed or the device latch bolt is retracted. This switch may be used for initiating an alarm. 2. The cylinder switch is actuated when the key is inserted into the lock cylinder and turned clockwise. This switch may be used for shunting or resetting an alarm. 3. A continuous current electric hinge or equivalent is required to transfer the wiring from the door to the frame. 4. Splice electric hinge wires and cable wires together with wire nuts. Unused wires should be cut off or insulated separately. 5. Cut device to proper length before connecting cable and switch wires. See Note #4 Touchbar switch Continuous current electric hinge (see Note #3) See Note #5 Cylinder switch Lock cylinder 7

330, 350, RX-330 and RX-350 Push Bar Trim Mechanical Installation (page 1 of 2) 1. Follow directions for fitting and cutting trim (see next page). See trim installation schedule below to determine proper formula to use. 2. Use lock stile mounting bracket to mark lock stile mounting holes, then prepare lock stile mounting holes. Be sure bracket is flush against mechanism case on both ends before marking holes; be sure trim is level. 3. Temporarily install trim using lock stile mounting bracket. 4. Insert hinge stile mounting bracket in hinge stile end of trim and mark hinge stile mounting holes. 5. Remove trim from door and prepare hinge stile mounting holes. 6. For RX-330/350 wiring, see page 10. 7. Install trim on door and attach end caps. Trim Installation Schedule Installation Stile Size Backset Single door ¹ ₂" stop and back to back with 386DT, 337DT or 696/697DT trim on single door ¹ ₂" stop Single door ⁵ ₈" stop and back to back with 386DT, 337DT or 696/697DT trim on single door ⁵ ₈" stop Pair of doors without mullion and back to back with 386DT, 337DT or 696/697DT trim on pair of doors without mullion Single door, pair of doors without mullion, and back to back with 990DT, 991DT, 992DT, or 230DT trim 1³ ₄" - 3" 1⁷ ₈" - 3" 1³ ₄" - 3" 3" flush 1⁵ ₁₆" 1⁷ ₁₆" 1⁵ ₁₆" ¹ ₂ of stile Cutoff Formula (see next page) Fig. 1A Fig. 1A Fig. 1B Fig. 1C Mounting holes CL Lock stile edge of door Sex bolt application (metal door) ¹ ₄" dia., 4 holes, inside face only ¹³ ₃₂" dia., 4 holes, outside face only Sex bolt application (wood door) ¹³ ₃₂" dia., 4 holes, drill thru Hinge stile edge of door CL Trim Surface mount application (metal door) #25 drill, #10-24 tap 4 holes 39¹³ ₁₆" to finished floor 8

330, 350, RX-330 and RX-350 Push Bar Trim Mechanical Installation (page 2 of 2) 1. To determine required trim length, fill in appropriate chart below Figure 1A, 1B, or 1C. See trim installation schedule on previous page to determine proper formula to use. 2. Cut trim as shown in Figure 2. Figure 1A Cutoff Instructions Figure 1B! NOTE Measure trim with both end caps and mounting brackets removed. Figure 1C Edge of stop "A" "C" "B" Edge of stop Hinge side Edge of stop "A" "C" "B" Hinge side Edge of stop CL Mounting holes ⁷ ₈" minimum "A" "C" "B" Hinge side Edge of stop Trim Cutoff Formula for Single Doors 1³ ₄ - 3" Stile 44¹⁵ ₁₆" (4' door) 32¹⁵ ₁₆" (3' door) + 2¹ ₁₆" "A" Trim length * Trim Cutoff Formula for Double Doors without Mullion 44¹⁵ ₁₆" (4' door) 32¹⁵ ₁₆" (3' door) + 2¹ ₂" "A" Trim length * Trim Cutoff Formula for 3" Stile - Flush 44¹⁵ ₁₆" (4' door) 32¹⁵ ₁₆" (3' door) + 2¹ ₁₆" "A" Trim length * = = = - "B" (stop to stop) - "B" (edge of door at lock stile to hinge stop) - "B" (C mounting holes to hinge stile stop) = "C" (cutoff dim.) = "C" (cutoff dim.) * "A" trim length is measured with both end caps and mounting brackets removed. = "C" (cutoff dim.) 1. Mark dimension "C" on mechanism case and cover plate. (Measure trim with both end caps and mounting brackets removed.) 2. Cut mechanism case and cover plate. Cover plate must be flush against end of mechanism case when cutting. 1 2 Figure 2 C 9

RX or RX-LC/S1 Switch Wiring RX - Switch is intended for signaling purposes only and is rated for a maximum 2 ampere resistance load at 24VDC/AC. Use with inductive or capacitive loads (magnetic locks or solenoid devices) derates the capacity of the switch. Consult the factory for assistance. RX-LC - Switch is intended for systems using low current signals and is rated for a maximum 50mA. Consult the factory for assistance. 1. The RX touchbar monitor switch is activated whenever the touchbar is depressed. 2. The switch function is shown with the latchbolt extended and the touchbar not depressed. NC C NO Switch Yellow *Red or Green Blue *Red = 2A Green = 50mA 3. Mark and drill wiring access hole on inside face of door (only after device is cut to length). 4. The Von Duprin EPT-10 power transfer (for three wires) or EPT-2 power transfer (for two wires) is required to transfer the wiring from the door to the frame. 5. Connect the power transfer wires and switch assembly wires with crimp connectors. Unused wires should be insulated separately. ⁵ ₁₆" ⁵ ₈" diameter access hole EPT shown. A door loop or electric hinge/pivot may also be used. Mechanism case End cap mounting bracket 10

LX or LX-LC Switch Wiring LX - Switch is intended for signaling purposes only and is rated for a maximum 2 ampere resistance load at 24VDC/AC. Use with inductive or capacitive loads (magnetic locks or solenoid devices) derates the capacity of the switch. Consult the factory for assistance. LX-LC - Switch is intended for systems using low current signals and is rated for a maximum 50mA. Consult the factory for assistance. 1. The latchbolt monitor switch is activated whenever the latch bolt is retracted. 2. The switch function is shown with the latchbolt extended and the touchbar not depressed. NC C NO Switch Violet *Wht or Blk Gray *White = 2A Black = 50mA 3. Mark and drill wiring access hole on inside face of door (only after device is cut to length). 4. The Von Duprin EPT-10 power transfer (for three wires) or EPT-2 power transfer (for two wires) is required to transfer the wiring from the door to the frame. 5. Connect the power transfer wires and switch assembly wires with crimp connectors. Unused wires should be insulated separately. ⁵ ₁₆" ⁵ ₈" diameter access hole EPT shown. A door loop or electric hinge/pivot may also be used. Mechanism case End cap mounting bracket 11

QEL Wiring & Configuration (page 1 of 3)! DANGER: To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board Tools for Installation ⁵ ₈" Drill Bit 1 Confirm Equipment Compatibility The QEL is compatible with the following equipment (refer to individual instructions as needed): PS900-Series power supplies - PS902, PS904, PS906, PS914 900-Series option boards - 900-2RS, 900-4R, 900-4RL, 900-2Q PS873 power supply plus 871-2, 871-2Q, 873-4TD/AO option boards 2 Drill Wire Access Hole ⁵ ₁₆" Drill ⁵ ₈" dia. access hole through device side of door. 12

QEL Wiring & Configuration (page 2 of 3) 3 Route Two Wires from QEL Exit Device to Power Supply QEL Electrical Load Voltage: 24 VDC Current: 1.4 A inrush (0.5 sec) 0.14 A holding 2.0 A calibrate (3 sec, one time) PS900-Series power supply with 900-Series option board(s) installed QEL device used with EPT, Door Loop, or Electric Hinge/Pivot Distance (one way) Wire Gauge 200 18AWG 320 16AWG 500 14AWG 800 12AWG EPT shown. A door loop or electric hinge/pivot may also be used. QEL Exit Device 13

QEL Wiring & Configuration (page 3 of 3) 4 Connect Input and Output Wires to Option Board (2RS Shown) Sequential Mode - Typical Wiring 120/240 VAC 50/60Hz 2RS Input I1 will activate both outputs SC I1 01 I2 02 GND Note: Fail secure output only allowed if approved by Authority Having Jurisdiction Access Control for Devices 1 & 2 EPT-2/10 EPT-2/10 QEL Device 1 QEL Device 2 (not polarized) (not polarized) Individual Mode - Typical Wiring 120/240 VAC 50/60Hz 2RS SC I1 01 I2 02 GND Input I1 will activate output 1 Input I2 will activate output 2 EPT-2/10 Access Control for Device 2 QEL Device 2 (not polarized) EPT-2/10 Access Control for Device 1 QEL Device 1 (not polarized) 5 Check Operation 14 NOTE: When using a PS902 power supply with two QEL exit devices, power must be applied to one device at a time. A. Activate each input and verify all QEL devices operate properly. NOTE: During the first activation, each device will perform a one time self calibration, which is normal. For best results, power each device separately so that the calibration cycles do not overlap. B. If any device does not operate properly, see step 6 for troubleshooting.

LED Calibrat e Button* QEL Troubleshooting (page 1 of 2) 6 If Necessary, Troubleshoot Operation Power at the QEL 0VDC QEL Response LED - Off Latchbolt extended LED - Solid green Latchbolt retracted Condition / Solution QEL is not receiving power to operate 1. Problem with power supply or wiring Operation normal LED - Solid red after latchbolt attempts to retract multiple times Improper mechanical adjustment or QEL calibration First check mechanical adjustment (on vertical rods or mortise lock devices, if used) and correct adjustments*. See Check Mechanical Operation on page 16, as needed. 24VDC Calibrate the QEL 1. Apply power and wait until the LED is solid red 2. Momentarily press the calibrate pushbutton (LED will flash green) 3. QEL will go through a retraction sequence to complete calibration, LED will be solid green and latchbolt retracted 4. Remove and reapply power to verify correct operation If the power to the QEL is being controlled by an access control system with momentary unlock, calibrate as follows: 1. Open door completely if using auto operator 2. Press and hold the QEL pushbutton 3. Activate the access control input to unlock the QEL 4. Immediately after the QEL LED turns on green, release the QEL pushbutton 5. The QEL will calibrate (this will look like a fast then a slow pull) 6. Reapply power to verify correct operation 12 VDC LED - Flashing green/red Latchbolt is not retracted LED - Solid red after latchbolt attempts to retract multiple times Excessive tamper (while power was applied, the pushpad was pulled out at least 3 times) 1. Wait 2 minutes, latchbolt will retract again; OR 2. Remove and reapply power to clear the condition Power supply is not set for proper voltage output 1. Remove AC from power supply, change it from 12 to 24VDC 2. Apply AC power to power supply and verify proper operation *For information about adjusting exit devices, go to w3.securitytechnologies.com or call Technical Services at 1-877-671-7011 OFF- No power GREEN- OK RED- Mechanical If using adjustment PS902, each required. Then QEL must calibrate. RED/GREEN- not in Excessive sequence. *If required. Apply power, press button. tamper, clears in 2 minutes. be calibrated individually, Calibration Button LED on Device 15

QEL Troubleshooting (page 2 of 2) Check Mechanical Operation 33A/3527A 33A/3547A 98/9927 98/9947 98/9947WDC 98/9957 98/9975 33/3549A 98/9949 98/9949WDC 1. Make sure device is not dogged for SD-QEL. 2. Depress pushbar and make sure latch bolt retracts and extends fully (see Figure 1). 3. If latch bolt does not retract or extend fully, adjustments may be required per the device installation instructions. 33A/3527A, 98/9927, 98/9957 deadlocked (will not push in) stays retracted Release trigger extended 1. Make sure device is not dogged for SD-QEL. 2. Depress pushbar. Door should begin to open with pushbar depressed halfway. 3. Close door. Top latch should be secure. If two point latch, bottom latch should be secure as well. 4. If device does not function as described in steps 2 and 3, adjustments may be required per the device installation instructions. with door closed ³ ₁₆" with door open 33A/3547A, 98/9947, 98/9947WDC deadlocked (will not push in) extended ⁵ ₈" 98/9975 extended ³ ₄" Flush within ¹ ₁₆" retracted retracted Flush within ¹ ₁₆" Figure 1 Customer Service 161-877-671-7011 www.allegion.com Allegion 2014 Printed in U.S.A. 24228413 Rev. 01/14-b