AREA OF WORK ENERGY

Similar documents
University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

CM 352 Electrical Construction Estimating

Recommended Procedures

A. This section includes unit capacitors for power factor correction.

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

CHAPTER V RESIDENTIAL WIRING

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Pretest Module 24 Three-phase Service Entrance

Installing a Downstream Distribution Panelboard

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

SECTION PANELBOARDS

Spring Test 10 due 05/11/2013

Generator Fire Safety: Generator assemblies should be located outside the building.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

University of Houston Master Construction Specifications Insert Project Name

GENERAL NOTES ELECTRICAL NOTES MATCH LINE SEE SHEET E1.11 KEY PLAN NTS MATCH LINE SEE SHEET E1.12 SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" TYP DH-108

10 Commercial, Industrial, Agricultural Services

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

Volume 2 Charts, Formulas, and Other Useful Information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:


THE CARMONY BUILDING ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED ELECTRICAL SYMBOLS AND ABBREVIATIONS

Commercial Meter Pedestals

SECTION MOTOR CONTROL

COMMERCIAL QUICK REFERENCE

Electrical Depth. Josh Kreutzberger Lighting/Electrical

Power Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Utility Main Service Transformers

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

320A Single Phase URD Meter Loop Installations

Owner s Manual. For Automatic Transfer Switch. 50 & 100 Amp. Model Number RTG10EZA1 RTG12EZA1 RTG16EZA1 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

East Central College

Electrical Design/Build Guide

Transmission & Distribution Glossary of Electrical Terms

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

SECTION 27 - PAD-MOUNTED TRANSFORMERS TABLE OF CONTENTS

Cole Service Building Boiler Replacement. Issued for Bidding and Construction August 30, 2012 Project Number G120270CD GENERAL ABBREVIATIONS

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Chapter 1 Electrical Theory...1

CITY OF MOSES LAKE MUNICIPAL SERVICES DEPARTMENT EN GINEERING DIVISION

SECTION DISTRIBUTION AND GROUNDING

Standby Electric Generators for Alaskan Residences. Advice & Installation

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park.

FACT SHEET Standard: Electrical Safety

Service Entrance Methods

American Electric Supply, Inc.

MYRON ZUCKER CALMANUAL POWER FACTOR CORRECTION APPLICATION GUIDE INC.

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications

LIFT STATION 11 ONE-LINE DIAGRAM

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Electrical Depth. Mark W. Miller Sibley memorial Hospital Grand Oaks Washington, DC CURRENT SYSTEM

2010 PM CM ELECTRICAL. The High-Velocity Edge: Achieving Operational Excellence. 21st Annual Conference

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

SIGNAL WORDS QUALIFIED PERSON

SECTION FIVE Electrical. 1A. MAIN LOBBY and LIBERTY AVENUE FACADE

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

DEWALT Electrical Licensing Exam Guide CONTENTS

1. Field verify measurements and circuiting arrangements as shown on as-built drawings.

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

What is included in a circuit diagram?

Spring Test 7 due 05/03/2013

1 OF 8 LAD LAD PROJECT AREA KIMBERLY GERBER TITLE SHEET C.E.S. DWG. NO. NPN12045 SHEET INDEX

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

Solar PV Standard Electrical Plan

Submittal Transmittal

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION CONTRACT PLANS FINANCIAL PROJECT ID (FEDERAL FUNDS) SEMINOLE COUNTY (77320)

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

TRANSMISSION SYSTEMS

Electrical Depth. Page 81

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

2010 National Electric Code

A. Submit manufacturer's literature and technical data before starting work.

M-1.0 FILE NAME: CAFE BIZOU CLIENT: CATHERINE MCKENNA PROJECT: PROJECT NO. REV DESCRIPTION DATE PLAN CHECK

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Solar PV Standard Electric Plan

EPRI s Utility Direct DC Fast Charger Development, Testing, Demonstration. Arindam Maitra IWC Meeting March 28, 2012

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Lighting and Power Distribution Panelboards

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Applying Interrupting Rating: Circuit Breakers

Overcurrent Protection According to the 2011 NEC

Low-Peak 600V Class RK1

Applying Interrupting Rating: Circuit Breakers

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

For Conduit Inspections

Transcription:

THIS DOCUMENT CONTAINS PROPRIETARY 408-859-545 AREA OF WORK

THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25SM Controllers Chlorking & CO-2 controlled by chemical controller 3 x Chlorking Cells, 25 lb per day each CO-2 Supply Salt Controller & Sensor ph 7.4 On 7.4 ORP 750 Off 752 Flow Switch On Temperaure: 8 408-859-545 Controller Sample Stream

THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25 Controller Chlorking & CO-2 controlled by chemical controller ph 7.4 On 7.4 ORP 750 Off 752 Flow Switch On Temperaure: 8 CO-2 Supply Chlorking Cell, 25 lb per day Salt Controller & Sensor Controller Sample Stream 408-859-545

THIS DOCUMENT CONTAINS PROPRIETARY 408-859-545

408-859-545 THIS DOCUMENT CONTAINS PROPRIETARY

0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" 00/3 70/3 PANEL "EPH" 00A, 480Y/277V, 3ɸ, 4W VFD 5/3 20 5 VFD LAP POOL PUMP DIVE POOL PUMP TO BE REPLACED IN KIND DISCONNECT PER MECHANICAL EQUIPMENT CONNECTION SCHEDULE, TYPICAL OF (7) 70/3 00/3 60/2 J CHLOR 40 # " C., (3) #4, AND () #8 GND. XFMR "TEPL2" 30 KVA, 480-208Y/20V, 3ɸ, 4W -/4" C., (4) #2, AND () #8 GND. PANEL "EPL2" 00A, 208Y/20V, 3ɸ, 4W 60/2 J CHLOR 40 #2 30/2 J CHLOR 25SM 45/2 3 P 3 20/2 20/2 20/2 P P 2 P 4 ELECTRICAL LOAD CALCULATION FOR PANEL EPH Phase A B C A+B+C 20 HP Lap Pool Pump 9.35 kva 9.35 kva 9.35 kva 28.05 kva +25% Largest Motor Load 2.34 kva 2.34 kva 2.34 kva 7.0 kva 5 HP Dive Pool Pump 2.0 kva 2.0 kva 2.0 kva 6.30 kva CHLOR 25SM CHLOR 40 CHLOR 40 P- P-2 P-3 P-4 SM- Total Load kva ( Existing and New) Total Load Amps ( Existing and New) 20/ J SM- 0.00 kva.56 kva.56 kva 3.2 kva 3.30 kva 3.30 kva 0.00 kva 6.60 kva 3.30 kva 0.00 kva 3.30 kva 6.60 kva 0.90 kva 0.90 kva 0.00 kva.80 kva 0.90 kva 0.00 kva 0.90 kva.80 kva 0.00 kva.95 kva.95 kva 3.90 kva 0.90 kva 0.90 kva 0.00 kva.80 kva 0.00 kva 0.00 kva.32 kva.32 kva 23.09 kva 22.40 kva22.82 kva68.30 kva 92.40 A 86.65 A 90.5 A 82.6 A Therefore 00A Panel, Breaker, and Feeder have capacity for the added load. Notes:. Existing loads calculated per 203 CEC 430.2. SEE MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR CONDUIT AND CONDUCTOR SIZING Panel: Panel "EPH" Location: Lower Mechanical Area Volts: 277/480V Wye Mains: 00A Main Breaker Supply From: 0 Phases: 3 Bus Rating: 00A Mounting: Surface Wires: 4 AIC Rating: - Load Description Load (VA) Circuit Breaker Ckt Ckt Circuit Breaker Load (VA) A B C Amp Pole # # Amps Poles A B C Load Description (R) ChlorTec 0 20 3 2 5 3 0 Spare - 0 - - 3 4 - - 0 - - 0 - - 5 6 - - 0 - Spare 0 5 3 7 8 5 3 0 Spare - 0 - - 9 0 - - 0 - - 0 - - 2 - - 0-5HP Dive Pool Pump 200 5 3 3 4 70 3 9350 20HP Lap Pool Pump - 200 - - 5 6 - - 9350 - - 200 - - 7 8 - - 9350 - Space - 9 20 - Space Space - 2 22 - Space Space - 23 24 - Space Space - 25 26 - Space Space - 27 28 - Space Space - 29 30 - Space Notes: Totals. kva Amps Phase A.5 3.79 Phase B.5 3.79 Phase C.5 3.79 Total 34.4 4.32 Panel: Panel "EPL2" Location: Lower Mechanical Area Volts: 20/208V Wye Mains: 00A Main Breaker Supply From: Panel "EPH" via Xfmr Phases: 3 Bus Rating: 00A Mounting: "TEPL2" Surface Wires: 4 AIC Rating: Match existing AIC Load Description Load (VA) Circuit Breaker Ckt Ckt Circuit Breaker Load (VA) Load Description A B C Amp Pole # # Amps Poles A B C CHLOR 40 #[] 3328 60 2 2 96 Pump P- - 3328 - - 3 4 96 - CHLOR 40 #2[] 3328 60 2 5 6 96 Pump P-2-3328 - - 7 8 96 - CHLOR 25SM [] 560 30 2 9 0 945 Pump P-3-560 - - 2 945 - Space - 3 4-96 Pump P-4 Space - 5 6-96 - Space - 7 8-320 SM- Space - 9 20 - Space - 2 22 - Totals Notes:. Provide new GFCI circuit breaker with rating indicated matching existing breaker type and AIC ratings. kva Amps Phase A 9.4 26. Phase B 8.7 24.06 Phase C 9. 25.8 Total 27. 75.34 SHEET INDEX E0 ELECTRICAL SHEET INDEX, SYMBOL LIST, ABBREVIATIONS, PANEL SCHEDULES, LOAD CALCULATIONS, ONE-LINE DIAGRAM AND CONNECTION SCHEDULE E MECHANICAL AREA - UPPER LEVEL - ELECTRICAL E2 MECHANICAL AREA - LOWER LEVEL - ELECTRICAL E3 ELECTRICAL SPECIFICATIONS A AFF C CKT CB DIA FLA (F) SYMBOL LIST EXISTING ELECTRICAL BRANCH CIRCUIT PANEL - SURFACE MOUNTED NON-FUSED SAFETY SWITCH DISCONNECT. SIZE AS NOTED. NEW CONDUIT WITH WIRING AS NOTED ON PLANS. EXISTING CONDUIT WITH WIRING TO BE REMOVED. NUMBERED SHEET NOTE TAG. REFER TO MATCHING NUMBERED SHEET NOTE ON SAME SHEET. ELECTRICAL MOTOR - SIZED IN AS NOTED (EXAMPLE 5HP). AMPERE ABOVE FINISHED FLOOR CONDUIT CIRCUIT CIRCUIT BREAKER DIAMETER EXISTING FULL LOAD AMPERES FUTURE GALV GALVANIZED GFCI INTERRUPTER HZ JB KVA KW LT 5 GROUND-FAULT CIRCUIT HERTZ JUNCTION BOX KILOVOLT AMPERE KILOWATT LIGHT ABBREVIATIONS N.C. NIC N.S. NTS OC PNL PH (R) NORMALLY CLOSED NOT IN CONTRACT NURSE STATION NOT TO SCALE ON CENTER PANEL PHASE REMOVE RCPT RECEPTACLE SM SMS SHEET METAL SHEET METAL SCREW SWBD SWITCHBOARD TYP. V VA W WP TYPICAL VOLT VOLT AMPERE WATT WEATHERPROOF Whittington Electric, Inc. WEI Project#: 25-095 940 Industrial Drive Auburn, CA 95603 Office (530) 823-3055 Fax (530) 823-3066 Engineering / Commercial / Industrial PARTIAL ONE-LINE POWER DIAGRAM SCALE: NONE MECHANICAL EQUIPMENT CONNECTION SCHEDULE EQUIPMENT DATA POWER SUPPLY CONDUIT & WIRE DISCONNECT SWITCH TYPE LOCATION SIZE DESIGNATION LOCATION HP OR KW FLA MCA MOCP PHASE VOLTS BREAKER POLES PANELBOARD OR MCC CKT # QUANTITIES AND SIZE SM- LOWER LEVEL -.0 A - - 20 V 20 A EPL2 8 /2"C, (2) #2 & () #2 GND - - - - - - P UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 2,4 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 P2 UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 6,8 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 P3 UPPER LEVEL 3 HP 8.7 A 24.0 A 45.0 A 208 V 45 A 2 EPL2 0,2 /2"C, (2) #8 & () #0 GND F X - 45 A 3R 60A/2P 3 P4 UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 4,6 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 CHLOR 25 UPPER LEVEL - 5.0 A - - 208 V 30 A 2 EPL2 9, /2"C, (2) #0 & () #0 GND NF X - - 3R 30A/2P 3 CHLOR 40- UPPER LEVEL - 32.0 A - - 208 V 60 A 2 EPL2,3 3/4"C, (2) #6 & () #0 GND NF X - - 3R 60A/2P 3 CHLOR 40-2 UPPER LEVEL - 32.0 A - - 208 V 60 A 2 EPL2 5,7 3/4"C, (2) #6 & () #0 GND NF X - - 3R 60A/2P 3 BLR- LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 BLR-2 LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 BLR-3 LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 BLR-4 LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 BLR-5 LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 Notes:. Mechanical to provide () SM- per sensor. See mechanical drawings. 2. Re-use existing circuits. Replacement in kind. No load chance. 3. Coordinate location with mechanical. See mechanical drawings. FUSED (F) OR NON-FUSED (NF) AT UNIT INTEGRAL FUSE SIZE NEMA ENCL. RATING NOTES Facility Project Sheet Title Scale: Drawn By: Checked By: REVIEW SET - NOT FOR CONSTRUCTION LANEY COLLEGE 900 FALLON STREET OAKLAND, CA 94607 LANEY COLLEGE POOL BOILER REPLACEMENT ELECTRICAL SHEET INDEX, SYMBOL LIST, ABBREVIATIONS, PANEL SCHEDULES, LOAD CALCULATION, ONE-LINE DIAGRAM, AND CONNECTION SCHEDULE AS NOTED Permit No.: Sheet E0 Issue Date: 07/5/206

0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" LOCATION OF NEW CHLORINATOR EQUIPMENT, COORDINATE WITH MECHANICAL MECHANICAL AREA - UPPER LEVEL - NEW ELECTRICAL SCALE: 3/4" = '-0" NUMBERED SHEET NOTES REMOVE EXISTING DISCONNECT, CONDUIT AND CONDUCTORS TO EXISTING CHLORINATION EQUIPMENT. Whittington Electric, Inc. WEI Project#: 25-095 Engineering / Commercial / Industrial 940 Industrial Drive Auburn, CA 95603 Office (530) 823-3055 Fax (530) 823-3066 (R) DISCONNECT, EPH-,3,5 (R) CHLORINATION EQUIPMENT REVIEW SET - NOT FOR CONSTRUCTION Facility LANEY COLLEGE 900 FALLON STREET OAKLAND, CA 94607 Project LANEY COLLEGE POOL BOILER REPLACEMENT Sheet Title MECHANICAL AREA FLOOR PLAN - UPPER LEVEL - ELECTRICAL 2 PARTIAL MECHANICAL AREA - UPPER LEVEL - DEMO ELECTRICAL SCALE: 3/4" = '-0" Scale: Drawn By: Checked By: AS NOTED Permit No.: Sheet E Issue Date: 07/5/206

0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" 4 5HP DIVE POOL PUMP 5 20HP LAP POOL PUMP VFD, DIVE POOL PUMP (5) BOILERS TO BE REPLACED IN KIND 5 20 VFD, LAP POOL PUMP 2 PANEL "EPH" 9 PANEL "EPL2" 0 XFMR "TEPL2" 3 PANEL "EPL" (R) ABANDONED FUSED DISCONNECTS 6 ELECTRICAL GUTTER 7 (R) ABANDONED CONDUIT 8 MECHANICAL AREA - LOWER LEVEL - ELECTRICAL SCALE: 3/4" = '-0" 2 3 4 5 NUMBERED SHEET NOTES EXISTING BOILERS TO BE REPLACED IN KIND. NO CHANGE IN PANEL/CIRCUIT LOADS. EXISTING 480/277V, 3 PHASE, 4 WIRE PANEL. SEE PANEL SCHEDULE, SHEET "E0". EXISTING 208/20V, 3 PHASE, 4 WIRE PANEL. EXISTING 5 HP DIVE POOL PUMP MOTOR TO BE REPLACE IN KIND. NO LOAD CHANGE. PROVIDE MEGGER TEST ON PHASE CONDUCTORS TO VERIFY CONDUCTOR INSULATION CONDITION. REPLACE CONDUCTORS IN KIND IF NECESSARY. EXISTING 20 HP LAP POOL PUMP MOTOR TO REMAIN. PROVIDE MEGGER TEST ON PHASE CONDUCTORS TO VERIFY CONDUCTOR INSULATION CONDITION. REPLACE CONDUCTORS IN KIND IF NECESSARY. Whittington Electric, Inc. WEI Project#: 25-095 940 Industrial Drive Auburn, CA 95603 Office (530) 823-3055 Fax (530) 823-3066 Engineering / Commercial / Industrial 6 7 REMOVE EXISTING FUSED DISCONNECTS. CIRCUIT BREAKERS ARE WITHIN LINE OF SITE AND OF SUITABLE RATING FOR SHORT-CIRCUIT AND GROUND FAULT PROTECTION OF CONDUCTORS. RELOCATE CONDUCTOR SPLICES INTO ELECTRICAL GUTTER ABOVE. IDENTIFY AND PROVIDE LABELS FOR ALL CIRCUIT CONDUCTORS IN GUTTER. REMOVE ABANDONED CONDUITS AND PROVIDE KNOCKOUT SEALS. Facility REVIEW SET - NOT FOR CONSTRUCTION LANEY COLLEGE 900 FALLON STREET OAKLAND, CA 94607 8 REMOVE ABANDONED CONDUIT. EXISTING CAT CABLE TO REMAIN, PROVIDE NEW CABLE SUPPORTS ALONG CONCRETE WALL. Project 9 PROVIDE NEW BRANCH CIRCUIT PANEL. SEE ONE-LINE DIAGRAM AND PANEL SCHEDULE, SHEET "E0". LANEY COLLEGE POOL BOILER REPLACEMENT 0 PROVIDE NEW TRANSFORMER. SEE ONE-LINE DIAGRAM, SHEET "E0". EXTEND HOUSE KEEPING PAD AS NECESSARY. Sheet Title MECHANICAL AREA FLOOR PLAN - LOWER LEVEL - ELECTRICAL Scale: Drawn By: Checked By: Issue Date: AS NOTED 07/5/206 Permit No.: Sheet E2