THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25SM Controllers Chlorking & CO-2 controlled by chemical controller 3 x Chlorking Cells, 25 lb per day each CO-2 Supply Salt Controller & Sensor ph 7.4 On 7.4 ORP 750 Off 752 Flow Switch On Temperaure: 8 408-859-545 Controller Sample Stream
THIS DOCUMENT CONTAINS PROPRIETARY Chlorking Chlor-25 Controller Chlorking & CO-2 controlled by chemical controller ph 7.4 On 7.4 ORP 750 Off 752 Flow Switch On Temperaure: 8 CO-2 Supply Chlorking Cell, 25 lb per day Salt Controller & Sensor Controller Sample Stream 408-859-545
THIS DOCUMENT CONTAINS PROPRIETARY 408-859-545
408-859-545 THIS DOCUMENT CONTAINS PROPRIETARY
0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" 00/3 70/3 PANEL "EPH" 00A, 480Y/277V, 3ɸ, 4W VFD 5/3 20 5 VFD LAP POOL PUMP DIVE POOL PUMP TO BE REPLACED IN KIND DISCONNECT PER MECHANICAL EQUIPMENT CONNECTION SCHEDULE, TYPICAL OF (7) 70/3 00/3 60/2 J CHLOR 40 # " C., (3) #4, AND () #8 GND. XFMR "TEPL2" 30 KVA, 480-208Y/20V, 3ɸ, 4W -/4" C., (4) #2, AND () #8 GND. PANEL "EPL2" 00A, 208Y/20V, 3ɸ, 4W 60/2 J CHLOR 40 #2 30/2 J CHLOR 25SM 45/2 3 P 3 20/2 20/2 20/2 P P 2 P 4 ELECTRICAL LOAD CALCULATION FOR PANEL EPH Phase A B C A+B+C 20 HP Lap Pool Pump 9.35 kva 9.35 kva 9.35 kva 28.05 kva +25% Largest Motor Load 2.34 kva 2.34 kva 2.34 kva 7.0 kva 5 HP Dive Pool Pump 2.0 kva 2.0 kva 2.0 kva 6.30 kva CHLOR 25SM CHLOR 40 CHLOR 40 P- P-2 P-3 P-4 SM- Total Load kva ( Existing and New) Total Load Amps ( Existing and New) 20/ J SM- 0.00 kva.56 kva.56 kva 3.2 kva 3.30 kva 3.30 kva 0.00 kva 6.60 kva 3.30 kva 0.00 kva 3.30 kva 6.60 kva 0.90 kva 0.90 kva 0.00 kva.80 kva 0.90 kva 0.00 kva 0.90 kva.80 kva 0.00 kva.95 kva.95 kva 3.90 kva 0.90 kva 0.90 kva 0.00 kva.80 kva 0.00 kva 0.00 kva.32 kva.32 kva 23.09 kva 22.40 kva22.82 kva68.30 kva 92.40 A 86.65 A 90.5 A 82.6 A Therefore 00A Panel, Breaker, and Feeder have capacity for the added load. Notes:. Existing loads calculated per 203 CEC 430.2. SEE MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR CONDUIT AND CONDUCTOR SIZING Panel: Panel "EPH" Location: Lower Mechanical Area Volts: 277/480V Wye Mains: 00A Main Breaker Supply From: 0 Phases: 3 Bus Rating: 00A Mounting: Surface Wires: 4 AIC Rating: - Load Description Load (VA) Circuit Breaker Ckt Ckt Circuit Breaker Load (VA) A B C Amp Pole # # Amps Poles A B C Load Description (R) ChlorTec 0 20 3 2 5 3 0 Spare - 0 - - 3 4 - - 0 - - 0 - - 5 6 - - 0 - Spare 0 5 3 7 8 5 3 0 Spare - 0 - - 9 0 - - 0 - - 0 - - 2 - - 0-5HP Dive Pool Pump 200 5 3 3 4 70 3 9350 20HP Lap Pool Pump - 200 - - 5 6 - - 9350 - - 200 - - 7 8 - - 9350 - Space - 9 20 - Space Space - 2 22 - Space Space - 23 24 - Space Space - 25 26 - Space Space - 27 28 - Space Space - 29 30 - Space Notes: Totals. kva Amps Phase A.5 3.79 Phase B.5 3.79 Phase C.5 3.79 Total 34.4 4.32 Panel: Panel "EPL2" Location: Lower Mechanical Area Volts: 20/208V Wye Mains: 00A Main Breaker Supply From: Panel "EPH" via Xfmr Phases: 3 Bus Rating: 00A Mounting: "TEPL2" Surface Wires: 4 AIC Rating: Match existing AIC Load Description Load (VA) Circuit Breaker Ckt Ckt Circuit Breaker Load (VA) Load Description A B C Amp Pole # # Amps Poles A B C CHLOR 40 #[] 3328 60 2 2 96 Pump P- - 3328 - - 3 4 96 - CHLOR 40 #2[] 3328 60 2 5 6 96 Pump P-2-3328 - - 7 8 96 - CHLOR 25SM [] 560 30 2 9 0 945 Pump P-3-560 - - 2 945 - Space - 3 4-96 Pump P-4 Space - 5 6-96 - Space - 7 8-320 SM- Space - 9 20 - Space - 2 22 - Totals Notes:. Provide new GFCI circuit breaker with rating indicated matching existing breaker type and AIC ratings. kva Amps Phase A 9.4 26. Phase B 8.7 24.06 Phase C 9. 25.8 Total 27. 75.34 SHEET INDEX E0 ELECTRICAL SHEET INDEX, SYMBOL LIST, ABBREVIATIONS, PANEL SCHEDULES, LOAD CALCULATIONS, ONE-LINE DIAGRAM AND CONNECTION SCHEDULE E MECHANICAL AREA - UPPER LEVEL - ELECTRICAL E2 MECHANICAL AREA - LOWER LEVEL - ELECTRICAL E3 ELECTRICAL SPECIFICATIONS A AFF C CKT CB DIA FLA (F) SYMBOL LIST EXISTING ELECTRICAL BRANCH CIRCUIT PANEL - SURFACE MOUNTED NON-FUSED SAFETY SWITCH DISCONNECT. SIZE AS NOTED. NEW CONDUIT WITH WIRING AS NOTED ON PLANS. EXISTING CONDUIT WITH WIRING TO BE REMOVED. NUMBERED SHEET NOTE TAG. REFER TO MATCHING NUMBERED SHEET NOTE ON SAME SHEET. ELECTRICAL MOTOR - SIZED IN AS NOTED (EXAMPLE 5HP). AMPERE ABOVE FINISHED FLOOR CONDUIT CIRCUIT CIRCUIT BREAKER DIAMETER EXISTING FULL LOAD AMPERES FUTURE GALV GALVANIZED GFCI INTERRUPTER HZ JB KVA KW LT 5 GROUND-FAULT CIRCUIT HERTZ JUNCTION BOX KILOVOLT AMPERE KILOWATT LIGHT ABBREVIATIONS N.C. NIC N.S. NTS OC PNL PH (R) NORMALLY CLOSED NOT IN CONTRACT NURSE STATION NOT TO SCALE ON CENTER PANEL PHASE REMOVE RCPT RECEPTACLE SM SMS SHEET METAL SHEET METAL SCREW SWBD SWITCHBOARD TYP. V VA W WP TYPICAL VOLT VOLT AMPERE WATT WEATHERPROOF Whittington Electric, Inc. WEI Project#: 25-095 940 Industrial Drive Auburn, CA 95603 Office (530) 823-3055 Fax (530) 823-3066 Engineering / Commercial / Industrial PARTIAL ONE-LINE POWER DIAGRAM SCALE: NONE MECHANICAL EQUIPMENT CONNECTION SCHEDULE EQUIPMENT DATA POWER SUPPLY CONDUIT & WIRE DISCONNECT SWITCH TYPE LOCATION SIZE DESIGNATION LOCATION HP OR KW FLA MCA MOCP PHASE VOLTS BREAKER POLES PANELBOARD OR MCC CKT # QUANTITIES AND SIZE SM- LOWER LEVEL -.0 A - - 20 V 20 A EPL2 8 /2"C, (2) #2 & () #2 GND - - - - - - P UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 2,4 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 P2 UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 6,8 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 P3 UPPER LEVEL 3 HP 8.7 A 24.0 A 45.0 A 208 V 45 A 2 EPL2 0,2 /2"C, (2) #8 & () #0 GND F X - 45 A 3R 60A/2P 3 P4 UPPER LEVEL HP 8.8 A.0 A 20.0 A 208 V 20 A 2 EPL2 4,6 /2"C, (2) #2 & () #2 GND F X - 20 A 3R 30A/2P 3 CHLOR 25 UPPER LEVEL - 5.0 A - - 208 V 30 A 2 EPL2 9, /2"C, (2) #0 & () #0 GND NF X - - 3R 30A/2P 3 CHLOR 40- UPPER LEVEL - 32.0 A - - 208 V 60 A 2 EPL2,3 3/4"C, (2) #6 & () #0 GND NF X - - 3R 60A/2P 3 CHLOR 40-2 UPPER LEVEL - 32.0 A - - 208 V 60 A 2 EPL2 5,7 3/4"C, (2) #6 & () #0 GND NF X - - 3R 60A/2P 3 BLR- LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 BLR-2 LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 BLR-3 LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 BLR-4 LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 BLR-5 LOWER LEVEL - 5.0 A - - 20 V 20 A - - /2"C, (2) #2 & () #2 GND - - - - - - 2 Notes:. Mechanical to provide () SM- per sensor. See mechanical drawings. 2. Re-use existing circuits. Replacement in kind. No load chance. 3. Coordinate location with mechanical. See mechanical drawings. FUSED (F) OR NON-FUSED (NF) AT UNIT INTEGRAL FUSE SIZE NEMA ENCL. RATING NOTES Facility Project Sheet Title Scale: Drawn By: Checked By: REVIEW SET - NOT FOR CONSTRUCTION LANEY COLLEGE 900 FALLON STREET OAKLAND, CA 94607 LANEY COLLEGE POOL BOILER REPLACEMENT ELECTRICAL SHEET INDEX, SYMBOL LIST, ABBREVIATIONS, PANEL SCHEDULES, LOAD CALCULATION, ONE-LINE DIAGRAM, AND CONNECTION SCHEDULE AS NOTED Permit No.: Sheet E0 Issue Date: 07/5/206
0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" LOCATION OF NEW CHLORINATOR EQUIPMENT, COORDINATE WITH MECHANICAL MECHANICAL AREA - UPPER LEVEL - NEW ELECTRICAL SCALE: 3/4" = '-0" NUMBERED SHEET NOTES REMOVE EXISTING DISCONNECT, CONDUIT AND CONDUCTORS TO EXISTING CHLORINATION EQUIPMENT. Whittington Electric, Inc. WEI Project#: 25-095 Engineering / Commercial / Industrial 940 Industrial Drive Auburn, CA 95603 Office (530) 823-3055 Fax (530) 823-3066 (R) DISCONNECT, EPH-,3,5 (R) CHLORINATION EQUIPMENT REVIEW SET - NOT FOR CONSTRUCTION Facility LANEY COLLEGE 900 FALLON STREET OAKLAND, CA 94607 Project LANEY COLLEGE POOL BOILER REPLACEMENT Sheet Title MECHANICAL AREA FLOOR PLAN - UPPER LEVEL - ELECTRICAL 2 PARTIAL MECHANICAL AREA - UPPER LEVEL - DEMO ELECTRICAL SCALE: 3/4" = '-0" Scale: Drawn By: Checked By: AS NOTED Permit No.: Sheet E Issue Date: 07/5/206
0 5' 50' 0 5' 25' 0 ' 2' 0 ' 6' 0 4' 0 ' 3' IF THIS SHEET IS NOT 24"x36", IT IS A REDUCED PRINT SCALE ACCORDINGLY GRAPHIC SCALES: /6" = '-0" /8" = '-0" /4" = '-0" /2" = '-0" 3/4" = '-0" " = '-0" 4 5HP DIVE POOL PUMP 5 20HP LAP POOL PUMP VFD, DIVE POOL PUMP (5) BOILERS TO BE REPLACED IN KIND 5 20 VFD, LAP POOL PUMP 2 PANEL "EPH" 9 PANEL "EPL2" 0 XFMR "TEPL2" 3 PANEL "EPL" (R) ABANDONED FUSED DISCONNECTS 6 ELECTRICAL GUTTER 7 (R) ABANDONED CONDUIT 8 MECHANICAL AREA - LOWER LEVEL - ELECTRICAL SCALE: 3/4" = '-0" 2 3 4 5 NUMBERED SHEET NOTES EXISTING BOILERS TO BE REPLACED IN KIND. NO CHANGE IN PANEL/CIRCUIT LOADS. EXISTING 480/277V, 3 PHASE, 4 WIRE PANEL. SEE PANEL SCHEDULE, SHEET "E0". EXISTING 208/20V, 3 PHASE, 4 WIRE PANEL. EXISTING 5 HP DIVE POOL PUMP MOTOR TO BE REPLACE IN KIND. NO LOAD CHANGE. PROVIDE MEGGER TEST ON PHASE CONDUCTORS TO VERIFY CONDUCTOR INSULATION CONDITION. REPLACE CONDUCTORS IN KIND IF NECESSARY. EXISTING 20 HP LAP POOL PUMP MOTOR TO REMAIN. PROVIDE MEGGER TEST ON PHASE CONDUCTORS TO VERIFY CONDUCTOR INSULATION CONDITION. REPLACE CONDUCTORS IN KIND IF NECESSARY. Whittington Electric, Inc. WEI Project#: 25-095 940 Industrial Drive Auburn, CA 95603 Office (530) 823-3055 Fax (530) 823-3066 Engineering / Commercial / Industrial 6 7 REMOVE EXISTING FUSED DISCONNECTS. CIRCUIT BREAKERS ARE WITHIN LINE OF SITE AND OF SUITABLE RATING FOR SHORT-CIRCUIT AND GROUND FAULT PROTECTION OF CONDUCTORS. RELOCATE CONDUCTOR SPLICES INTO ELECTRICAL GUTTER ABOVE. IDENTIFY AND PROVIDE LABELS FOR ALL CIRCUIT CONDUCTORS IN GUTTER. REMOVE ABANDONED CONDUITS AND PROVIDE KNOCKOUT SEALS. Facility REVIEW SET - NOT FOR CONSTRUCTION LANEY COLLEGE 900 FALLON STREET OAKLAND, CA 94607 8 REMOVE ABANDONED CONDUIT. EXISTING CAT CABLE TO REMAIN, PROVIDE NEW CABLE SUPPORTS ALONG CONCRETE WALL. Project 9 PROVIDE NEW BRANCH CIRCUIT PANEL. SEE ONE-LINE DIAGRAM AND PANEL SCHEDULE, SHEET "E0". LANEY COLLEGE POOL BOILER REPLACEMENT 0 PROVIDE NEW TRANSFORMER. SEE ONE-LINE DIAGRAM, SHEET "E0". EXTEND HOUSE KEEPING PAD AS NECESSARY. Sheet Title MECHANICAL AREA FLOOR PLAN - LOWER LEVEL - ELECTRICAL Scale: Drawn By: Checked By: Issue Date: AS NOTED 07/5/206 Permit No.: Sheet E2