STAG AC W02 / AC W03 Injectors

Similar documents
new products R02 W02 STAG-4 QBOX PLUS 200 GoFast

COMPACT The smallest construction Full of possibilities in its class

The unit design based on a high-performance 32-bit microprocessor

INSTALLATION MANUAL. Fuel Pressure Emulator. (variable pressure)

Market leader. Warsaw stock exchange

LAMBDA SENSOR CONTROLLER

MITSUBISHI DIESEL ENGINE IFM NO. JN (1/6) TECHNICAL INFORMATION DATE Aug. 8, 2002

MITSUBISHI S16R-C2MPTK

1104D-44TG2 1104D-44TG kwm 1500/1800 rpm. ElectropaK. Series. Basic technical data. Performance

Connection and Programming Manual for

@Perkins. Technical Data. 1106D-E66TAG3 159, rev/min. 1100D Series. ElectropaK

LPGTECH Sp. z o.o. ul. Dojnowska 67, Białystok, Poland tel PRODUCT CATALOGUE

@Perkins. Technical Data. 192, rev/min. ElectropaK

Illustrated Parts List. 58A400 to 58A499 TURBO DIESEL

C87 ENT 260 kw ( rpm rpm Stage IIIA / Tier 3

Installation And Programming Manual of OPTIMA Eco Tec and OPTIMA Pro Tec OBD/CAN

ABC OF USAGE WGs INJECTORS

1992 Toyota Cressida

STAG. Autogas installations

Instruction of connection and programming of the OSCAR-N controller

1106A-70TAG4. Series kwm 1500 rpm ElectropaK. Basic technical data. General installation

KTA50 Land Based Drilling Power Modules

Engine Diagrams

2013. The engine for agricultural equipment kw at 2100 rpm

General 4-stroke direct injected, turbocharged and aftercooled diesel engine

MAKE OF AUTOMOBILE: NUMBER : 076/ DATE : Copyright Prins Autogassystemen B.V VERSION NR : B

Performance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0)

3. Fuel System FUEL SYSTEM FUEL INJECTION (FUEL SYSTEM) A: GENERAL. FU(STi)-7

UAV EFI components In miniature sizes

Power where you need it...when you need it!!!

1106A-70TAG4. Series kwm 1500rpm ElectropaK. Basic technical data

CURSOR13 TE2 GENSET ENGINE CURSOR PERFORMANCES

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

Simple Carburettor Fuel System for a Piston Engine. And how it works

1/18. Important TWD1673GE

Power where you need it...when you need it!!!

1106A-70TAG3. Series kwm 1500rpm ElectropaK. Basic technical data

1999 F-150/250 Workshop Manual

Technical Data 2506A-E15TAG3 2506A-E15TAG Series. Diesel Engine - ElectropaK

MAKE OF AUTOMOBILE: ENGINE SET NUMBER 345/ NUMBER : 076/ DATE : VERSION NR : B

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Ejector, Series EBS Thread connection pneumatic control, T-design with silencer

G-Drive Engine Data Sheet

ENGINE PERFORMANCE CURVE M3-135 hp ( rpm M2-120 hp ( rpm

7,15 436, Bore , ,12 Compression ratio 18 Wet weight. Engine incl. cooling system and air filtration system

@Perkins. Technical Data Series 1103C-33TG3. Performance. Basic technical data. Test conditions. Total weight (fan to flywheel)) Sound level

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Type TW02. WEH - We Engineer Hightech. WEH Connector for pressure and vacuum testing DATA SHEET

Data sheet. D-2011/05/ Date: 07/2013. Type TK4 CNG. CNG Fuelling Nozzle. for cars. WEH - We Engineer Hightech

CHAPTER 2 : ESSENTIAL CHARACTERISTICS OF THE VEHICLE AND ENGINE AND INFORMATION CONCERNING THE CONDUCT OF TESTS

Data sheet. D-2011/05/ Date: 07/2013. Type TK1 CNG. CNG Fuelling Nozzle. for time filling of cars. WEH - We Engineer Hightech

S16U-TA MITSUBISHI DIESEL ENGINES

7,15 436, Bore , ,12 Compression ratio. 17 Wet weight

Technical Manual. Installation Instructions Safety Notices Programming Operation

7,15 436, Bore , ,12 Compression ratio. 18 Wet weight

Data sheet. D-2011/05/ Date: 02/2013. Type TK16 CNG. CNG Fuelling Nozzle. for cars at self-service fuelling stations

CHALLENGER TWIN TURBO SYSTEM INSTALLATION INSTRUCTIONS

Technical Data. ElectropaK

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

Fuel System Diagnosis

Syslog Technologies Innovative Thoughts

1106A-70TAG2. Series kwm 1800rpm ElectropaK. Basic technical data

Technical Data Series 1103D-33 G3. Diesel engine - Electropak rpm


MODEL PERFORMANCE. ENGINE MOUNTING Maximum Bending Moment at Rear Face of Block... lb ft (N m) 1000 (1356)

Romano Injection System 01/11/2013 Rev. 0

DatA sheet. D-2011/05/ Date: 02/2013. Type TK10 CNG. CNG Fuelling Nozzle. for cars FUTURE. TECHNOLOGY. TODAY.

STARTER COMPONENTS FOR REMOVAL AND INSTALLATION

SEQUENT 56: MULTIPOINT SEQUENTIAL INJECTION SYSTEM FOR CYLINDER VEHICLES FIELD OF APPLICATION

CCMT - Electrically operated valves for transcritical and subcritical CO2

CHAPTER 2 : ESSENTIAL CHARACTERISTICS OF THE VEHICLE AND ENGINE AND INFORMATION CONCERNING THE CONDUCT OF TESTS

General Manager/Service Manager/Warranty Administrator. 2015FL-005 Attachment #2 1KD Diesel Turbo Replacement Campaign Repair Instructions

Technical Installation Guide

(3) (4) (6) (5) (10) (9) (8) (7)

NEF67 SM1 GENSET ENGINE NEF PERFORMANCES

@Perkins. Technical Data Series 2806C-E18TAG1A. Diesel Engine - ElectropaK. Basic technical data. Cyclic irregularity. Ratings.

@Perkins. Technical Data Series 2806A-E18TAG1A. Basic technical data. Cyclic irregularity for engine/flywheel maximum: Ratings.

5.2L and 5.9L ENGINE PROCEDURE

TP-702 always exceeds your expectations

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

4,76 290,7 Firing order Bore

Engine only. Engine only. without fan kw hp with fan kw hp Power setting

Installation Instructions General Motors 8.1 Sequential Vapor Injection (S.V.I.) System 7500/6500 Series Trucks model year.

Poznan University of Technology. Division of Internal Combustion Engines REPORT. CO2 emission research in dual fuel Scania R450 Euro 6

1606A-E93TAG4. Series kwm 1800 rpm ElectropaK. Basic technical data. Performance. Test conditions. Notes:

GENERAL PUMPA member of the Interpump Group

VSO - MI thermally compensated proportional valve

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow

EGR Transient Simulation of a Turbocharged Diesel Engine using GT-Power

1 Engine and peripherals

INNOVATION WITH LIGHTNESS STEYR MONOBLOCK DIESEL FOR HEAVY DUTY DEMANDS

@Perkins. Technical Data Series 2806C-E18TAG3. Diesel Engine - ElectropaK. Cyclic irregularity. Basic technical data. Ratings.

Oil/Air Cooler Units

Oil Module in the Inner V

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

Installation Manual v1.0: The Torque Pro Propane Injection System GM. Please read all instructions before installation.

CAMSHAFT POSITION SENSOR

Power Rating Minimum Rating 116 bkw 156 bhp Maximum Rating 205 bkw 275 bhp. 105 mm (4.1 in) 135 mm (5.3 in)

Transcription:

STAG AC W02 / AC W03 Injectors

STAG AC W02/AC W03 STAG AC W02 and STAG AC W03 injectors are designed for LPG and CNG injection systems in all vehicle engines, including turbocharged ones. The device ensures excellent operating parameters and compatibility with other products of AC S.A. The AC injectors is available in the following two design versions: STAG AC W02 - four-section injector rail. STAG AC W03 - as a single section injector can be installed in a wide range of configurations and settings. LPG CNG 120 l/min. 1,2 bar LPG CNG 120 l/min. 1,2 bar

STAG AC W02/AC W03 Modern design The injectors have been designed to provide accurate injection times in any conditions. This has been achieved by using specifically selected materials, a lighter and simpler construction that ensures excellent stability in variable ambient conditions, in particular temperature and pressure. Innovative heat dissipation system The injector coil housings are built in the form of radiator this is an innovative solution which has not been seen on the market so far that ensures the best heat dissipation system and guarantees excellent performance. Ideal system for connecting components The system for connecting components allows a large number of mounting positions. The unique construction enables the PS-04 integrated gas temperature sensor, vacuum and pressure sensor to be installed on any side. This sensor shows low inertia of the response to gas temperature changes and can be rotated by 3 even after it has been installed on the injector. 3 Measurement accuracy W02 and W03 injectors, due to excellent opening and closing times, quickly react to minimum and transient control signal changes. The close vicinity of the pressure sensor and the injectors ensures precise measurements as well.

STAG AC W02 Technical specification Dimensions Gas flow through section at 1.2 bar [l/min] 120 Working temperature [ C] -20 to +120 44 Maximum working pressure [kpa] 400 Opening time / closing time [ms] 2,0/ 1,0 Suggested nozzle size Ø 1,5; Ø 1,8; Ø 2,0; Ø 2,2; Ø 2,4; Ø 2,6 (can be drilled independently up to Ø 2.8 max.) 44 44 Gas inlet pipe stub [mm] Ø 12 Gas outlet pipe stub [mm] Ø 6 Overall dimensions [mm] 125 x x 44 Service life [km] - in urban cycle 100 tys. 124.5 145.5 - in extra urban cycle 200 tys. Weight [g] 410 44 Accessories Pipe connectors Injector nozzles Nozzles to the intake manifold Injection rail mounting Protection Snail clamp 7-11 Snail clamp 12-22 8x/W02 1x/W02

STAG AC W03 Technical specification Dimensions Gas flow through section at 1.2 bar [l/min] 120 Working temperature [ C] -20 to +120 Maximum working pressure [kpa] 400 Opening time / closing time [ms] 2,0/ 1,0 Suggested nozzle size Ø 1,5; Ø 1,8; Ø 2,0; Ø 2,2; Ø 2,4; Ø 2,6 (can be drilled independently up to Ø 2.8 max.) Gas inlet pipe stub [mm] Ø 6 Gas outlet pipe stub [mm] Ø 6 28.5 48 28.5 Overall dimensions [mm] 48 x x 28,5 Service life [km] - in urban cycle 100 tys. - in extra urban cycle 200 tys. Weight [g] 88 28.5 Accessories 48 3-section distributor 4-section distributor Injector pipe connectors Pipe connector protection Nozzles to the intake manifold Injector nozzles Snail clamp 7-11 Snail clamp 12-22 Pipe connector and distributor plug Distributor protection OPTION 1 4x/W03 1x/W03 Elbow ps Three way connector End elbow Pipe connector protection Nozzles to the intake manifold Injector nozzles Snail clamp 7-11 Snail clamp 12-22 OPTION 2 4x/W03 2x/W03

Configuration options STAG AC W02 1. ACW02 injector rail with a direct connection of the PS04 sensor allowing sensor turning to adjust its position and ensure precise measurements of pressure and temperature. 2. ACW02 injector rail with the PS04 sensor installed on the feeding line, using a T-connector.

Configuration options STAG AC W03 1. Connection of the PS04 sensor on the distribution rail to ACW03 injector. 2. Connection of the PS04 sensor to the feed pipe of the ACW03 injector and between ACW03 injectors on the feeding line.

STAG AC W02/AC W03 Standards and approvals STAG AC W02 injector has been approved under E8 approval No. E8 67R-01 7064, 110R-00 7065 and meets the requirements of UNECE Regulations. STAG AC W03 injector has been approved under E8 approval No. E8 67R-01 7294, 110R-00 7295 and meets the requirements of UNECE Regulations. AC Spółka Akcyjna ul. 42 Pułku Piechoty 50, 15-181 Białystok, Poland tel. +48 85 743 81 00, fax +48 85 653 93 83 info@ac.com.pl www.stag.pl www.ac.com.pl AC S.A. reserves the right to make changes to the information herein. At the time of submitting to publication, the information was valid. Due to AC s program of continuous product improvement, the information herein may be subject to change without prior notice