Standby KW. Standby KVA G180D 230/ N/A

Similar documents
Standby KW. Standby KVA G150I 230/400* N/A

Standby KW. Standby KVA G15LSM 400/230* N/A

28 KW / 28 KVA POWERED by

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

18 KW / 18 KVA POWERED by

600 KW / 750 KVA POWERED by

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

55 KW / 70 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

130 KW / 165 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

30 KW / 40 KVA POWERED by

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

64 KW / 80 KVA POWERED by

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Standby Amper VOLTAGE

204 KW / 254 KVA POWERED by

2000 KW / 2500 KVA POWERED by

Standby Amper VOLTAGE

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

APD-ULJ250. Standby Power

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

APD 1650 M. Generator expert, honest advice with competitive solutions kva Diesel Generating Sets

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

APD-NG400. NG Standby Power

GUASCOR LEROY SOMER P 732 control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

GE.VO.360/325.SS+0_all

DIESEL GENERATOR SET. DE22E3 (B Series) Output Ratings. Technical Data

Rental Power 4BTAA3.3 series engine

1000 KW / 1250 KVA POWERED by

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

1 / Genset general description

Rental Power Kubota V2403 series engine

1 / Genset general description

10,000 Watt Diesel Generator AGi9P E

13,000 Watt Diesel Generator AGi13P E

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

Standby Amper VOLTAGE

640 KW / 800 KVA POWERED by

TPD2250H6.3 TECHNICAL DATA

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

GE.PK.022/020.SS+0_all

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

45 KW / 55 KVA POWERED by

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

16 KW / 20 KVA POWERED by

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

700 KVA / 550 KW POWERED by

1800 KW / 2250 KVA POWERED by

1 / Genset general description

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

80 KW / 100 KVA POWERED by

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Voltage. kva kw kva kw

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

WPS60/S EP Series. Features:

DIESEL GENERATOR DATA SHEET

PGDLS352KW 380/ / / / / / / / /

PGDLS / / / / / / / / /

Model NA 2 L

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Diesel generator set QSK23 series engine

WPS100/S EP Series. Features:

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS / / / / / / / / /

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

WPS350/S EP Series. Features:

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Rating Definitions and Conditions

Transcription:

STAR R O Y A L Genmac provides one-source responsibility for the generating and accessories. All units and components are prototype tested, factory build and production tested. A specific control procedure during the several stages of production ensures long life and reliability. Rugged 4 cycle heavy-duty Industrial diesel engine, of primary brands with direct fuel injection and swirl intake ports combine for a low fuel consumption and excellent transient response. Powerful alternators with insulation of H class and impregnation made with tropicalized epoxy resins, are used as standard. Generator set accepts one-step 100% of full load. The variation of the Voltage is maintained between +- 1% by sophisticated Electronic Voltage Regulators. Fully programmable AMF controller is supplied with auto start control and digital instrumentation. Automatic device for setting the periodic exercise is integrated into the AMF. Heavy-duty built-in anti-vibration insulators assures lower noise and longer components life. Protection guards on rotating parts Fork-lifting facilities are supplied together with 4 lifting brackets on the base frame The Silent version consist of a weather-proof bolted modular pre-painted enclosure (2000/14/CE compliant) with hinged lockable doors, radiator coolant hatch, base mounted radiator coolant and engine oil drain lines. These items affords superior flexibility and ease of maintenance. A stub-up area is provided to make easier the electrical connection to the load. A wide range of accessories is provided on request in order to satisfy the needs of the user and to let the generator work in almost every condition. RATINGS Model Voltage Phase Hz Power Factor KW Amps KW Amps Starting G180D 230/400 3 50 0.8 160 200 289 144 180 260 N/A RATING DEFINITION Rating: Applicable for supplying emergency power for the duration of normal power interruption limited to maximum 500h per year within the following maximum operating time: 100% load 25h per year, 90% load 200h per year. No overload capability is permitted for this rating. Limited Time running Power (LTP) rating conforms to ISO 8528-1. Rating: Applicable for supplying power at a variable load for an unlimited number of hours per year. A 10% overload capability is available for one hour in twelve hours periods. This rating conforms to ISO 8528-1 Running Power (PRP). STANDARD REFERENCE CONDITIONS: The above mentioned power data are calculated with: air temeparture of 25 C (77 F); 99kPa of barometric pressure, 100m of altitude a.s.l and 30% of relative humidity. For different conditions please refear to the derating factor s table specific for this engine. Datasheet_Star G180DOA_Royal G180DSA_7320 pag. 1/5

Alternator Electrical Exhaust Air Cool ant Oil Fuel Engine basic data General 50Hz@1500rpm STAR G180DOA - ROYAL G180DSA INSTALLATION AND APPLICATION DATA Emission certificates Units 50 Hz 60 Hz PRP LTP PRP LTP EU2002-88 STAGE2 Noise level (silent version) db(a) 7mt 68 Rated Speed rpm 1500 Engine Brand - Model Deutz - BF6M1013FCG3 Gross Engine Output hp (KW) 243 (178,6) 267 (196,6) Number and arrangement of cylinders Type of air intake Type of cooling 6 vertical in-line Turbocharged, air-to-air charge cooled Water-cooled Total displacement liters (cu. In.) 7.1 (439) Bore x Stroke mm (in.) 108 (4,25) x 130 (5.11) Speed control Electronic Speed drop +- 0,5% Type of fuel Diesel Maximum Fuel Transfer Pump Lift m (ft) 1,5 (4,9) Fuel consumpion @ 25% load Liters/h (gal/h) N/A N/A N/A N/A Fuel consumpion @ 50% load Liters/h (gal/h) 20.9 (4.59) N/A N/A N/A Fuel consumpion @ 75% load Liters/h (gal/h) 31.3 (6.8) N/A N/A N/A Fuel consumpion @ 100% load Liters/h (gal/h) 42 (9.23) N/A N/A N/A Standard fuel tank capacity (open) Liters (gal) 350 (92.4) Autonomy @75% load (open) Hours 11 Standard fuel tank capacity (silent) Liters (gal) 350 (92.4) Autonomy @75% load (silent) Hours 11 Type of oil (for usage at std reference conditions) SAE 15W40 Total Quantity of oil (including filters) Liters (qt. ) 20 (21.1) Maximum Oil consumption Type of coolant 0.3% of fuel consumption Glicole Mixture 50% Antifreeze 50% demineralized water Total quantity of coolant Liters (qt) 27.3 (28.8) Air filter type Dry Element Max. perm. intake vacuum mbar 50 Combustion air flow m 3 /min (cf/min) 12,9 (455) 14,3 (505) 14.3 (505) 15.9 (561) Exhaust flow m 3 /min (cf/min) 33.1 (1168) 36,5 (1288) 36.5 (1288) 40,4 (1426) Max. permissible exhaust backpressure barm 30 Outlet size diameter mm (in.) 140 (5,5) Voltage of electric V 24 Starter motor capacity A 166 Type of battery Lead acid type Number of poles 4 Number of bearings 1 Excitation Type of regulation Regulator model Self excitated Automatic Voltage Regulation DSR Voltage accuracy ±1 % with any power factor and speed variations between -5% +30% Datasheet_Star G180DOA_Royal G180DSA_7320 pag. 2/5

STANDARD EQUIPMENTS ENGINE Air Cleaner (Dry-cartridge type) Fuel Pump Fuel Filter Fuel stop solenoid Thermostat and Housing Dry Exhaust Manifold Blower Fan & Fan Drive Radiator - Unit Mounted Electric Starting Motor Housing & Flywheel Charging Alternator Battery Rack & Cables First filling of oil and filters* First filling of coolant* Mechanical oil pump * unless differently stated by selected means of transport GENERATOR Self-ventilated and drip-proof construction Synchronous, Brush-less, Self Exciting, Self Regulating Direct Coupled With Flex Disk 12 Leads winding Class H Insulation Drip-Proof Construction Humidity Tropical Protection Radio Interference Suppressor EMC Filter EXHAUST Built-in Industrial Muffler (for Open generators ) Built-in Residential Muffler (for Silent generators) Rain Cap HANDLING Fork lift facilities Lifting and holding down points ELECTRICAL SYSTEM Battery (for 50Hz is supplied as standard, for 60Hz is to be ordered separately) Battery rack and cables Engine driven battery charger CANOPY (for silent units) Nylon hinges Heavy duty lockable handles in each door Large doors for easy access for service and monitoring Coolant refilling specific hatch Sound foam Class 1compliant Modular bolted assembly after painting. Grey RAL 7035 orange peel specific powder coat paint for outdoor usage Weatherproof sealed joints. Cut using high precision laser technology. Bent using high precision numeric control technology. Glazed acoustic sealed control panel door. Fuel filler outside enclosure. In base oil and coolant drains CONTROL PANEL (see specific section below) AMF controller DSE 7320 Fuel level gauge Three phase sensing for voltage and currents Battery charger Circuit breaker (for 50Hz-230/400V is supplied as standard, for other voltages is to be ordered separately) On/Off button Emergency stop button External ATS connection board EC Conformity in compliance with EN 60439-1 PACKAGING BASE FRAME Heavy duty fabricated welded base plate with high quality steel. Heavy duty rubber anti-vibration mountings Integrated fuel tank with drain plug and fuel sender Stub-up area PHYSICAL DATA Units Star G180DOA Royal G180DSA Length mm (in.) 2900 (114) 3600 (142) Width mm (in.) 1190 (47) 1226 (48) Height mm (in.) 1864 (74) 2000 (79) Weight Kg (lbs) 1785 (3935) 2225 (4905) Nylon filming protection package Alternator, Engine and Generating set operator s manual are supplied together with electrical drawings Datasheet_Star G180DOA_Royal G180DSA_7320 pag. 3/5

CONTROL PANEL CIRCUIT BREAKER 50Hz 400V generators are supplied together with a circuit breaker that permits a thermal protection against overloads and magnetic protection against short-circuit. For 60Hz or 50Hz-230V versions the circuit breaker has to be ordered separately indicating the voltage at which the generator has to work. All the generator of this line are fully re-connectable according to the specification indicated in the RATINGS BOOK QUICK CONNECTOR FOR REMOTE START A 10 pin terminal board is supplied in order to connect easily the generator to an external device for remote start and stop. TERMINAL BOARD (For 60Hz versions) An internal terminal board with bocks is provided to make easier the connection from the load to the generator output. COMMANDER DSE 7320 The DSE7310 is an Auto Start Control Module suitable for a wide variety of single, diesel or gas, gen-set applications. Monitoring an extensive number of engine parameters, the modules will display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LEDs, remote PC and via SMS text alerts (with external modem). Reactive power protection 4-Line back-lit LCD text display Five key menu navigation Front panel editing with PIN protection Customisable status screens Power save mode Support for up to three remote display units 9 configurable inputs 8 configurable outputs Flexible sender inputs Configurable timers and alarms 3 configurable maintenance alarms Multiple date and time scheduler Configurable event log (250) Control logic facilities Easy access diagnostic page CAN and Magnetic Pick-up/Alt. sensing Fuel usage monitor and low fuel alarms Charge alternator failure alarm Manual speed control (on compatible CAN engines) Manual fuel pump control Engine exerciser Protections disabled feature kw & kv Ar overload protection Reverse power (kw & kv Ar) protection LED and LCD alarm indication Power monitoring (kw h, kv Ar, kv A h, kv Ar h) Load switching (load shedding and dummy load outputs) Automatic load transfer Unbalanced load protection Independent Earth Fault trip USB connectivity Backed up real time clock Fully configurable via DSE Configuration Suite PC software Configurable display languages Remote SCADA monitoring via DSE Configuration Suite PC software User selectable RS232 and RS485 communications Configurable Gencomm pages Advanced SMS messaging (additional external modem required) Start & stop capability via SMS messaging Additional display screens to help with modem diagnostics DSENet expansion compatible Integral PLC editor Real-time clock provides accurate event logging Multiple date and time scheduler Set maintenance periods can be configured to maintain optimum engine performance Ethernet communications (via DSE860/865 modules), provides advanced remote monitoring at low cost Modules can be integrated into building management s (BMS) Increased input and output expansion capability via DSENet Licence-free PC software PLC editor allows user configurable functions to meet specific application requirements Display Information Engine Speed Oil and coolant Pressure (available only if engine has canbus reading) Oil and Coolant Temperature (available only if engine has canbus reading) Engine Battery Volts Run Time Inlet and exh. Temperature (available only if engine has canbus reading) Fuel Temperature (available only if engine has canbus reading) Turbo Pressure (available only if engine has canbus reading) Fuel Pressure (available only if engine has canbus reading) Fuel Consumption Fuel Used Fuel Level Auxiliary Sensors (If fitted and configured) Engine Maintenance Due (If configured) Engine ECU Link Generator Voltage (ph-n, ph-ph) Generator Frequency Generator Current Generator Earth Current Generator Load (kw, kva) Generator Power Factor Generator Load (kvar, kwh, kvah, kvarh) Generator Phase Sequence Technical data Protection IP65 Working and stocking temperature -30 C + 70 C Range Vdc 8..35 Range Vac (L-N) 15..333 Range Hz 3,5..75 Display 132x64 pixel, 63x33 mm Reference EN61010 CRANKING DROPOUTS - Able to survive 0 V for 50 ms, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. Warnings CHARGE FAILURE BATTERY UNDER/ OVER VOLTAGE FAIL TO STOP FUEL USAGE AUXILIARY INPUTS LOW FUEL LEVEL kw OVERLOAD EARTH FAULT NEGATIVE PHASE SEQUENCE MAINTENANCE DUE LOADING VOLTAGE NOT REACHED LOADING FREQUENCY NOT REACHED PROTECTIONS DISABLED LOW OIL PRESSURE ENGINE HIGH TEMPERATURE ENGINE LOW TEMPERATURE OVERSPEED/UNDERSPEED GENERATOR OVER/UNDER FREQUENCY GENERATOR OVER/UNDER VOLTAGE ECU WARNING Alarms Earth fault Fail to start Emergency stop Low oil pressure shutdown/ High coolant temperature shutdown Low fuel level Over/under speed shutdown Over/under voltage shutdown Over/under Frequency shutdown Oil pressure sensor open circuit Auxiliary inputs Loss of speed signal Can ECU data fail or Can ECU shutdown KW Overload Phase rotation and Negative phase sequence Maintenance Due Generator high current Loading voltage/frequency not reached Protections disabled Datasheet_Star G180DOA_Royal G180DSA_7320 pag. 4/5

OPTIONAL EQUIPMENTS A wide range of optional equipments are available to satisfy all the needs of the installator. Please contact GenMac s sales department for full details of these and other options ENGINE Starting aids (glow plugs-coolant heaters-oil heaters..) Double-stage filters GENERATOR Thermal protections Anti-condensation heaters Special treatment for usage in marine environmental conditions Full power alternator for single phase connection EXHAUST Exhaust adapters Extension exhaust hose FAP filters WARNINGS ELECTRICAL SYSTEM AND CONTROL PANEL Auxiliary sockets and plugs Oil pressure meter Water temperature meter Generator Monitoring/Remote control of complete (with analog, GSM or Ethernet connection) Automatic Transfer Switches HANDLING AND CANOPY Central lifting hook Slow drive trailers On-road Trailers Bigger Fuel tanks Double wall UL compliant fuel tanks Precision fuel sender MAINTENANCE Consumable Filters and spares for each maintenance interval Access to control panel and doors on both sides for inspection and maintenance is required. Adequate ventilation on both sides is required. WARRANTY Please refer to Genmac for warranty policy described into WG001 module. All Specifications and Materials are subject to change without prior notice. Datasheet_Star G180DOA_Royal G180DSA_7320 pag. 5/5