ELECTRONIC SOFT STARTER

Similar documents
RVS-AX Instruction Manual


High Performance, High Function System Drive SOFTSTARTER SS7. 2.2kW ~ 1.5MW / 230 ~ 690V. Drive Solution

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Design Guide. VLT Soft Start Controller MCD 100

Dimensions WxHxD [mm] Weight [kg]

Application example of a motor controlled by MCD100 and protected by a circuit breaker

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

SOLSTART Instruction Manual

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

Softstarters Softstarters

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

ABB Softstarters The new PSS line from 3A to 515A

Panorama. Softstarters The complete range

Application Description

PSE The efficient range Description

SSW07. Soft Starters. Applications. Standard Features

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Starts, stops and protects. Emotron TSA Softstarter

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Number 1 in efficiency

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

CD AUTOMATION SOFT STARTERS FAMILY

PCS compact soft starters

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Reduced Voltage Motor Starters

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

J1000. Compact Inverter Series.

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Variable speed drive or soft starter?

Softstarters Type PSS. Softstarters. General information

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

THE COMPLETE SOLUTION FOR STARTING AND STOPPING AC MOTORS. MCD 3000 Soft starter

RVS-DN Digital Reduced Voltage Motor Starter

MCD 200 Series Soft Starters

Product Description. Application Description

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

RVS-DX Digital Reduced Voltage Motor Starter

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Low cost, internally bypassed non optimizing soft starter

MAKING MODERN LIVING POSSIBLE. VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 500

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Features and Benefits. Control Features

Oil cooled motor starters MOTORSTARTERS. High torque low current

Game changing soft starters

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Electrak Vdc - load up to 250 lbf. Performance Specifications. Standard Features and Benefits. General Specifications. Compatible Controls

J1000 D E F I 1000 J1000 J1000 J1000 J1000

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB

Reduced Voltage Motor Starters

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Softstarter Intelligent Controllers

Softstarters. Softstarters Power electronic brakes Type PEB

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Catalog. Softstarters Type PSR, PSS, PSE, PST and PSTB

Medium Voltage Soft Starters MOTOR CONTROL IS OUR NATURE

Softstarters Type PSR, PSS, PSE, PST and PSTB

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

Electrical Engineering Info

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Softstarters Type PSS Type PST/PSTB - New range. New. Catalogue 1SFC132001C0201, Revised in October SFC132016F0201

TWIN SQUIF FANS RUN & STANDBY SOLUTION FOR ALL 'MOTOR OUT AIRSTREAM' APPLICATIONS. FOR HIGH TEMPERATURE RANGE REFER TO SMOKE SECTION

ABB component drives ACS150, 0.5 to 5 Hp

CTi Automation - Phone: Fax: Web:

ABB Component Drives ACS150, 0.5 to 5 Hp

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

MS General Information Extended Product Type: MS

Softstarters. Catalogue. Type PSR. Catalogue 1SFC132003C0201 (1SFC132152F001)

A softstarter beyond the ordinary

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

INTER PLANT STANDARD STEEL INDUSTRY NO CORRESPONDING IS

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Softstarters PSR PSS PST Extreme duty

For Operation in the Control Cabinet 3RW Soft Starters

AuCom - Soft Starters

Phone: Fax: Web:

Submittal Data Information

Delta Products VFD CP2000 Bypass Control Packages.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Benefits. transmission devices (gearboxes, pulleys, gears, conveyers, etc) Soft-Star ters are static star ting switches, designed for the

ABB Softstarter Benefits Charnchanok Thongprad

Designed for ease of integration with automation systems

LH4 Modular Soft Start

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

GS2 Series - Introduction

Reduced Voltage Motor Starters

USERS MANUAL MCD REMOTE OPERATOR

Description 1/8-7.5HP

TECHNICAL CATALOGUE. Softstarter range. CNABB /1SFC en, May-2000R

Transcription:

ELECTROIC SOFT STARTER V2 Voltage range from 230V - 400V and power from 2.2kW - 37kW Multiple built-in motor protections Wide temperature range from 0 to +50 C (IP54)/40 C (IP00) Available with internal bypass Maximum starting torque in motor Easy adjustment of parameters using potentiometers 3 year warranty and 24h service and replancement commitment 28-29

05. V2 SOFT STARTER For over two decades, the V2 series is part of the family of Power Electronics soft starters. It is a compact and efficient solution. It is equipped with an advanced control technology and motor protection. With coated electronics, the V2 is resistant in harsh environments. It has also been designed in two versions, IP00 and IP54 incorporating an integrated bypass that reduces wiring installation. Features as underload and overload, two stopping options, by inertia or deceleration and its compact size and multiple protections make this soft starter the optimum solution for many applications. ROBUST, EASY AD COMPATIBLE WITH MULTIPLE APPLICATIOS

Discovering V2 WIDE POWER RAGE Power from 2.2kW to 37kW, 220-400V. Giving your installation features that guarantee a safe operation. EASY ISTALLATIO Its compact size makes possible the installation of multiple softstarters in the same cabinet. AVAILABLE WITH ITEGRATED BYPASS. MOTOR PROTECTIOS STILL ACTIVE COATED BOARDS V2 boards are coated to withstand the harshest environments. DEGREE OF PROTECTIO IP54 AD IP00 The V2 soft starters are available with IP00 protection for temperatures of 40 C (with external bypass) and IP54 for temperatures of 50 C (with built-in bypass). EASY SET UP OF PARAMETERS A series of potentiometers allow a precise adjustment of parameters and protections. LED status indicators allow an easy configuration and monitoring. 30-31

05. TORQUE (%) 100% End of acceleration RATED CURRET Start of deceleration EASY PROGRAMMIG. The potentiometers adjust parameters such as current limit, overload, underload, initial torque, acceleration and deceleration s and overload curve. LED1 LED2 LED3 LED4 READY RU OL WARIG/ UL FAULT OVERLOAD V2 SOFT STARTER Start of acceleration Initial torque Acceleration Deceleration End of deceleration TIME normal start potentiometers configuration LED5 LED6 OVERTEMRATURE GEERAL FAULT IIT. TORQUE ACC. DEC. OVERLOAD O/L CURVE UDERLOAD U/L TIME I. LIMIT MI MAX MI MAX 2S. 15 S. 0.8xIn 1.2xIn MI MAX 0.2xIn 0.6xIn MI MAX 1 xin 5xIn APPLICATIOS Use the V2 soft starter with protections for overload, underload and for locked rotor, protecting your pumping equipment the best way possible. Furthermore, this soft starter has torque control or deceleration features that will prevent water hammer. Overall, the V2 with its soft start reduces mechanical stress to a minimum and extends the life of your facility. The IP54 protection and coated boards is suitable for more aggressive environments. Finally, pumps, fans, conveyors, compressors, agitators, mixers, elevators, cranes, forklifts... are some examples of applications that can benefit from the use of this equipment. LOW VOLTAGE / POWER ELECTROICS

Technical characteristics Power wiring Input voltage (3 phase) 230-400V (±10%) IPUT OUTPUT EVIROMETAL CODITIOS MOTOR PROTECTIOS SOFT STARTER PROTECTIOS ADJUSTMETS AUXILIARY COTACTS LED S IDICATIOS REGULATIOS Current range Frequency Control voltage Output voltage Output frequency 9A to 75A 47 to 62 Hz 230V ±10%, others under demand 0 to 100% of input voltage 47-62 Hz Efficiency (at full load) >99% Ambient temperature Storage temperature Humidity Altitude de-rating Protection degree Cooling Input phase loss Rotor locked Underload General fault Initial torque 30 to 99% Deceleration 0 to 45 sec. Overload curve 1 to 10 Underload curve 1 to 10 Operation: 0 C to +40 C. for IP00 Operation: 0 C to +50 C. for IP54 0 C to +70 C 95% at 40 C non condensing >1000m, 1% each 100m; maximum 3000m IP00; IP54 atural Starting current limit Motor overload (thermal model) Phases imbalance V2 over temperature Acceleration 0 to 15 sec. Overload 0.8 to 1.2 In Underload 0.2 to 0.6 In Current limit 1 to 5 In 2 change over relays 5A, 230Vac Fault relay Instantaneous relay LED 1 Ready LED 2 Start LED 3 Overload warning / Underload fault LED 4 Overload LED 5 Overtemperature LED 6 General fault CE, UL [1], cul [1], ctick OTE [1] On process. POWER WIRIG COFIGURATIO Q0 standard COECTIO F1* 1 2 ITERAL BYPASS COECTIO 1 F1* Q0 2 U V W L.C. 230Vac ITERAL BYPASS COTACTOR U V W L.C. 230Vac ELECTROIC SOFT STARTER U1 V1 W1 U1 V1 W1 M 3~ M 3~ 32-33

Ready Listo Fertig Run Marcha Läuft OL warning/ul fault Aviso sobrecarga/fallo subcarga Überlast warnung/unterlast Fehler Overload Sobrecarga Überlast Overtemperature Sobretemperatura Übertemperature General fault Fallo general Fehler Ready Listo Fertig Run Marcha Läuft OL warning/ul fault Aviso sobrecarga/fallo subcarga Überlast warnung/unterlast Fehler Overload Sobrecarga Überlast Overtemperature Sobretemperatura Übertemperature General fault Fallo general Fehler Standard ratings Dimensions and Control STADARD RATIGS FRAME CODE Rated I(A) 1 2 POWER MOTOR (kw) at 230V POWER MOTOR (kw) at 400V Protection degree V2009 9 2.2 4 IP00 V2017 17 4 7.5 IP00 V2030 30 9 15 IP00 V2045 45 15 22 IP00 V2060 [1] 60 18.5 30 IP00 V2075 [1] 75 22 37 IP00 V2009B 9 2.2 4 IP54 V2017B 17 4 7.5 IP54 V2030B 30 9 15 IP54 V2045B 45 15 22 IP54 V2060B 60 18.5 30 IP54 V2075B 75 22 37 IP54 05. V2 SOFT STARTER OTE DIMESIOS AD WEIGHTS 350 410 FRAME Weight (kg) 1 4.7 FRAME Weight (kg) 2 5 157 132 157 132 COTROL WIRIG COFIGURATIO DIGITAL OUTPUTS FAULT RELAY ISTATAEOUS RELAY DIGITAL IPUTS 1 2 3 4 5 6 7 8 9 10 11 12 13 L 230Vac Run/Stop Stop Run Reset [1] Includes an integrated Bypass function. The motor protection is operating all the time. Start pulse LOW VOLTAGE / POWER ELECTROICS