Ditec DOD Industrial sectional door automations

Similar documents
Ditec LUXO Swing gates automation (Original instruction)

Ditec BOX Balanced up and over doors

Ditec CUBIC Swing gates automation

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

Ditec PWR25H/35H Automation for hinged gates

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

Ditec PWR50H/HV/HR Automation for swing gates

Ditec VALOR Sliding doors automation (Original instructions)

Ditec VALOR HH-HS IP2063EN. Technical manual Sliding doors automation for hospitals and heavy sliding doors (Translation of the original instructions)

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

Ditec SPRINT Swing doors drive unit

IP2160EN. Ditec NeoS / NeoS+ Sliding Gates. Technical Manual. (Original instructions)

Entrematic Ditec Sprint 24V

Ditec SPRINT Automation for swing doors

Cross14, Cross14E, Cross14VE, Cross15V

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

QIK4E-QIK7EH. Installation and maintenance manual for electromechanical barrier. (Translation of the original instructions) IP1861EN- rev.

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

Ditec E1A. IP2045EN Technical manual. Control panel installation manual for one motor automation with built-in radio.

USER INSTRUCTIONS FOR SLIDING DOORS

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

INSTRUCTIONS FOR INSTALLATION

Rex. Manuale di installazione e manutenzione per porte scorrevoli. Installation and maintenance manual for sliding door

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

CE DECLARATION OF MACHINE CONFORMITY

Installation Manual. Swing Gate System. Leading the way...

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track

Ditec EL31R Installation Manual for control panel for 24V automations with built-in radio.

Maximum Weight = 80 kg for 2 doors; Maximum door width = 1100mm (to suit up to maximum 2120mm clear opening) Quick Start. 5 & 4mm Allen keys.

Automation Swing Gate Opener

Automatic concealed bollards 275 H600 and 275 H800 with pit

Cross Automations for sliding gates

BULL 424 ESA BULL 624 ESA

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

FORCE SPD 800/1500/2000

Automatic concealed bollards 275 H600 and 275 H800 Control station

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

Typical Installation Schematic

BISON 20 OM BISON 25 OTI

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

BELT CONVEYOR CB/M5 Series

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Everything becomes automatically more convenient! Discover the Ditec automation

EC DECLARATION OF CONFORMITY

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

FITTING AND CONNECTION INSTRUCTIONS

BELT CONVEYOR PNL/4 Series User and maintenance manual

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

SLIDE NEW CONTROL BOARD

Mod: KLD6-12/35XLAS-N

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

OPERATOR FOR GARAGE DOORS FA00047-EN INSTALLATION AND OPERATION V6000. English

Sectional and Tilting Door Opener

ISTRUCTION MANUAL Italian Movements Italian Movements

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

Porte 150 Users Manual Swing Gate Opener 24V DC

E R A I GATE AUTOMATION DIVISION

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

contents OPERATOR Maintenance SHAFT-120 Installation and Operating Manual DoorHan, 2012

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

Sectional and Tilting Door Opener Installation Instructions and User Guide

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

24 V ENCODER SAFE VERSATILE SETTING. Ditec Qik Automatic barriers for passages up to 7.6 m.

Northern Sales & Distribution Centre

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

Ditec PWR Automation system for swing gates with wings up to 5 metres

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Everything becomes automatically more convenient! Discover the Ditec automation

Ditec automatic pedestrian sliding doors.

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

TURBO 40 TURBO 80 TURBO 120 TURBO 160

ENG. Exeo. Revolving pedestrian door

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

Volo, Onda. Advanced entrance technology. Automation for curved sliding doors ENG

MP V 8A Electronic Smart Charger. Instruction and Information Manual

MGV25.X USER GUIDE. Ver. 3.7 INSTALLATION OPERATION AND MAINTENANCE MANUAL OF THE GEARLESS MGV25.2 MGV25.3 MGV25.5

BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

Ditec Alimax Rapid door for the food sector.

Transcription:

Ditec DOD Industrial sectional door automations (Original instructions) IP1733EN Technical manual www.ditecentrematic.com

Index Subject Page 1. General safety precautions 33 2. Declaration of incorporation of partly completed machinery 35 2.1 Machinery directive 35 3. Technical data 36 3.1 Applications 36 4. -14-15 axle installation 37 4.1 Overall dimensions 38 4.2 Motor installation 38 4.3 Installation 39 4.4 Installation DODMA 40 5. -14-15 chain link-up installation 41 5.1 Motor chain link-up 43 5.2 Installation 44 6. Cord release installation 45 7. Ditec DOD 12-14-15 sliding door configuration 46 8. Ditec DOD 12-14-15 + C1 sliding door configuration 47 9. Ditec DOD 12-14-15 folding door configuration 48 10. Electrical connections 49 10.1 Limit-switch adjustment 50 10.2 PS electrical connections 51 11. Routine maintenance plan 52 Operating instructions 53 Caption i This symbol indicates instructions or notes regarding safety, to which special attention must be paid. This symbol indicates useful information for the correct functioning of the product. 32

1. General safety precautions Failure to respect the information given in this manual may cause personal injury or damage to the device. Keep these instructions for future reference This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed by qualified personnel, in accordance with Good Working Methods and in compliance with the current regulations. Read the instructions carefully before installing the product. Bad installation could be dangerous. The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as they are a potential source of danger. Before installing the product, make sure it is in perfect condition. Do not install the product in explosive areas and atmospheres: the presence of inflammable gas or fumes represents a serious safety hazard. Before installing the motorisation device, make all the necessary structural modifications to create safety clearance and to guard or isolate all the crushing, shearing, trapping and general hazardous areas. Make sure the existing structure is up to standard in terms of strength and stability. The motorisation device manufacturer is not responsible for failure to observe Good Working Methods when building the frames to be motorised, or for any deformation during use. The safety devices (photocells, safety edges, emergency stops, etc.) must be installed taking into account: applicable laws and directives, Good Working Methods, installation premises, system operating logic and the forces developed by the motorised door or gate. The safety devices must protect against crushing, cutting, trapping and general danger areas of the motorised door or gate. Display the signs required by law to identify hazardous areas. Each installation must bear a visible indication of the data identifying the motorised door or gate. When necessary, connect the motorised door or gate to an effective earthing system that complies with the current safety standards. During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the electrical parts. The automation protection casing must be removed by qualified personnel only. The electronic parts must be handled using earthed antistatic conductive arms. The manufacturer of the motorisation declines all responsibility if component parts not compatible with safe and correct operation are fitted. Only use original spare parts for repairing or replacing products. The installer must supply all information concerning the automatic, manual and emergency operation of the motorised door or gate, and must provide the user with the operating instructions. 33

General safety precautions for the user These precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and forwarded to all possible future users of the system. This product must only be used for the specific purpose for which it was designed. Any other use is to be considered improper and therefore dangerous. The manufacturer cannot be held responsible for any damage caused by improper, incorrect or unreasonable use. Avoid operating in the proximity of the hinges or moving mechanical parts. Do not enter within the operating range of the motorised door or gate while it is moving. Do not obstruct the motion of the motorised door or gate, as this may cause a dangerous situation. The motorised door or gate may be used by children over the age of 8 and by people with reduced physical, sensorial or mental abilities, or lack of experience or knowledge, as long as they are properly supervised or have been instructed in the safe use of the device and the relative hazards. Children must be supervised to make sure they do not play with the device, nor play/remain in the sphere of action of the motorised door or gate. Keep remote controls and/or any other command devices out of the reach of children, to avoid any accidental activation of the motorised door or gate. In the event of a product fault or malfunction, turn off the power supply switch. Do not attempt to repair or intervene directly, and contact only qualified personnel. Failure to comply with the above may cause a dangerous situation. Any repair or technical intervention must be carried out by qualified personnel. Cleaning and maintenance work must not be carried out by children unless they are supervised. To ensure that the system works efficiently and correctly, the manufacturer s indications must be complied with and only qualified personnel must perform routine maintenance on the motorised door or gate. In 34

particular, regular checks are recommended in order to verify that the safety devices are operating correctly. All installation, maintenance and repair work must be documented and made available to the user. Only lock and release the door wings when the motor is switched off. Do not enter within the operating range of the wing. To dispose of electrical and electronic equipment correctly, users must take the product to special recycling centres provided by the municipal authorities. 2. Declaration of incorporation of partly completed machinery (Directive 2006/42/EC, Annex II-B) The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10, SE-261 44 Landskrona, Sweden declares that the automation system for Ditec DOD sectional doors: - has been constructed to be installed on a manual door to construct a machine pursuant to the Directive 2006/42/EC. The manufacturer of the motorized door shall declare conformity pursuant to the Directive 2006/42/EC (annex II-A), prior to the machine being put into service; - conforms to applicable essential safety requirements indicated in annex I, chapter 1 of the Directive 2006/42/EC; - conforms to the Low Voltage Directive 2006/95/EC; - conforms to the Electromagnetic Compatibility Directive 2004/108/EC; - technical documentation conforms to Annex VII-B to the Directive 2006/42/EC; - technical documentation is managed by Marco Pietro Zini with offices in Via Mons. Banfi, 3-21042 Caronno Pertusella (VA) - ITALY; - a copy of technical documentation will be provided to national competent authorities, following a suitably justified request. Landskrona, 15-07-2013 Marco Pietro oz Zini (BA President) en 2.1 Machinery Directive Pursuant to Machinery Directive (2006/42/EC) the installer who motorizes a door or gate has the same obligations as the manufacturer of machinery and as such must: - prepare the technical file which must contain the documents indicated in Annex V of the Machinery Directive; (The technical file must be kept and placed at the disposal of competent national authorities for at least ten years from the date of manufacture of the motorized door); - draw up the EC Declaration of Conformity in accordance with Annex II-A of the Machinery Directive and deliver it to the customer; - affix the EC marking on the motorized door in accordance with point 1.7.3 of Annex I of the Machinery Directive. 35

3. Technical data Ditec DOD 12 Ditec DOD 14 Ditec DOD 15 Ditec DOD 14PS Power supply 230 V~ 50 Hz 230 V~ 50 Hz 400 V~ 50 Hz 230 V~ 50 Hz Absorption 3 A 3 A 1,2 A 3 A Motor power 350 W 350 W 450 W 350 W Torque 45 Nm 60 Nm 65 Nm 60 Nm Revolution 32 RPM transmission shaft 22 RPM 32 RPM 22 RPM Capacitor 25 μf 22 μf - 22 μf Service class 4 - INTENSIVE 4 - INTENSIVE 4 - INTENSIVE Min. number 50 consecutive cycles 50 50 Intermittence S2 = 30 min S2 = 30 min S2 = 30 min S3 = 50% S3 = 50% S3 = 50% Temperature -20 C - +55 C -35 C - +55 C with NIO enabled -20 C - +55 C -35 C - +55 C with NIO enabled -20 C - +55 C -20 C - +55 C Degree of protection IP40 IP40 IP40 IP40 Weight 15 kg 15 kg 15 kg 15 kg Control panel E1A E1A E1T - 3.1 Application Service class: 4 (minimum 100 cycles a day for 10 years or 200 cycles a day for 5 years) Use: INTENSIVE (For pedestrian accesses with intensive use). - The operating performance specifications refer to the recommended weight (about 2/3 of maximum allowed weight). Use with maximum allowed weight could reduce the above performance specifications in tecnhical data. - The service class, operating times and number of consecutive cycles are merely approximate. These have been statistically determined in average conditions of use and are not certain for each single case. - Each automatic entrance features variable factors such as: friction, balancing and environmental conditions that can substantially change both the duration and operating quality of the automatic entrance or part of its components (including automatic system). It is up to the installer to adopt adequate safety coefficients for each single installation. ATTENTION:, and geared motors may be used for operating sectional doors only if correctly balanced. The sectional doors can only be manually moved by means of a handle (installing the DODSBV release device) or a chain (installing the DODSBC release device). i The given operating and performance features can only be guaranteed with the use of ENTREMATIC accessories and safety devices. 36

4. Ditec DOD 12-14 -15 axle installation E1A E1T 4x1.5 mm² (motor) 3x0.5 mm² (limitswitch) 3x1.5 mm² [-14] 4x1.5 mm² [] N WARNING: For correct operation we advise to move the door at a speed lower than 0.2 m/s. Type Pinion Crown Reduction ratio Torque [Nm] Rotating speed [RPM] DOD 12 - - 1:1 45 32 DOD 14 - - 1:1 60 22 Door cable pulley [ mm] 102 124 158 226 102 124 158 226 Door speed [m/s] 0,17 0,21 0,26 0,38 =:597 0,12 0,14 0,18 0,26 =:868 Max Run [m] 8,7 10,6 13,6 19,4 =:11,66 8,7 10,6 13,6 19,4 =:11,66 Max force [N] 706 581 456 319 =72000: 941 774 608 425 =96000: DOD 15 - - 1:1 65 32 102 124 158 226 0,17 0,21 0,26 0,38 =:597 8,7 10,6 13,6 19,4 =:11,66 1020 839 658 460 =104000: 37

4.1 Overall dimensions Unless otherwise specified, all measurements are expressed in millimetres (mm). 40 225 90 135 100 4.2 Motor assembling 30 320 40 60 40 120 135 5 100 25.4 (1") 65 6.35 (1/4") 6.35 (1/4") 9.5 (3/8") 65 264 Mount the -14-15 motor onto the wall bracket and release idle bracket as shown in figure. 38

4.3 Installation - Fit the -14-15 motor onto the drive shaft. - After having determined the position of the wall bracket, drill the holes and secure the bracket in place with dowels (not supplied). - Insert the appropriate cotter according to shaft cavity length. - Secure the metal clamp so as to prevent the risk of the cotter coming out of the shaft. ATTENTION: firmly tighten down all fastening screws. min 130 2 1 3 6.35 (1/4") 6.35 (1/4") 4 9.5 (3/8") 39

4.4 DODMA [DODMA1] : =25,6 mm [DODMA2] : =34 mm 1 min 60 2 8 3 4 40

5. Ditec DOD 12-14 -15 chain link-up installation DODC30 DODC39 DODC45 CAT1+ CATG E1A E1T 3x1.5 mm² [-14] 4x1.5 mm² [] 4x1.5 mm² (motor) 3x0.5 mm² (limitswitch) WARNING: For correct operation we advise to move the door at a speed lower than 0.2 m/s. 41

DODC30 (Z30) CAT1+ CATG N Type Pinion Crown DODC30 (Z30) DODC30 (Z30) DODC30 (Z30) Reduction ratio Torque [Nm] Rotating speed [RPM] 1:1,25 56 25,6 1:1,25 75 17,6 1:1,25 81 25,6 Door cable pulley [ mm] 102 124 158 226 102 124 158 226 102 124 158 226 Door speed [m/s] 0,14 0,17 0,21 0,30 = : 746 0,09 0,11 0,15 0,21 = : 1085 0,14 0,17 0,21 0,30 = : 746 Max Run [m] 7,0 8,5 10,8 15,5 = : 14,57 7,0 8,5 10,8 15,5 = : 14,57 7,0 8,5 10,8 15,5 = : 14,57 Max force [N] 882 726 570 398 = 90000 : 1176 968 759 531 = 120000 : 1275 1048 823 575 = 130000 : DODC39 (Z39) CAT1+ CATG N Type Pinion Crown DODC39 (Z39) DODC39 (Z39) DODC39 (Z39) Reduction ratio Torque [Nm] Rotating speed [RPM] 1:1,625 73 19,7 1:1,625 98 13,5 1:1,625 106 19,7 Door cable pulley [ mm] 102 124 158 226 102 124 158 226 102 124 158 226 Door speed [m/s] 0,11 0,13 0,16 0,23 = : 970 0,07 0,09 0,11 0,16 = : 1415 0,11 0,13 0,16 0,23 = : 970 Max Run [m] 5,4 6,5 8,3 11,9 = : 18,95 5,4 6,5 8,3 11,9 = : 18,95 5,4 6,5 8,3 11,9 = : 18,95 Max force [N] 1147 944 741 518 =117000: 1529 1258 987 690 =156000: 1667 1371 1076 752 =170000: 42

DODC45 (Z45) CAT1+ CATG N Type Pinion Crown DODC45 (Z45) DODC45 (Z45) DODC45 (Z45) Reduction ratio Torque [Nm] Rotating speed [RPM] 1:1,875 84 17,1 1:1,875 113 11,7 1:1,875 122 17,1 Door cable pulley [ mm] 102 124 158 226 102 124 158 226 102 124 158 226 Door speed [m/s] 0,09 0,11 0,14 0,20 = : 1119 0,06 0,08 0,10 0,14 = : 1632 0,09 0,11 0,14 0,20 = : 1119 Max Run [m] 4,7 5,7 7,2 10,3 =:21,86 4,7 5,7 7,2 10,3 =:21,86 4,7 5,7 7,2 10,3 =:21,86 Max force [N] 1324 1089 854 597 =135000: 1756 1452 1139 796 =180000: 1912 1573 1234 863 =195000: 5.1 Motor-chain link-up Fasten the wall and release idle brackets to the -14-15 motor and then fit on the pinion pin () in the traction position (i.e. on either one of the two sides of the motor). 43

5.2 Installation - After having determined the position of the wall bracket, drill the holes and secure the bracket in place with dowels (not included). - Fit the crown wheel onto the sectional door shaft and insert the appropriate cotter depending on shaft cavity length. Fasten the metal clamps so as to prevent the risk of the cotter coming out of the shaft. - Link up crown and pinion by means of the chain. Properly tauten the chain by acting on the wall anchoring brackets. Fix the bracket [A] to avoid that the shaft of the sectional bends and to guarantee the correct tensioning of the chain. ATTENTION: firmly tighten down all fastening screws. 1 3 2 3 6.35 (1/4") 6.35 (1/4") 9.5 (3/8") A 4 5 44

DITEC S.p.A. VIA MONS. BANFI,3 ITALY 21042 CARONNO P.LLA (VA) TEL.02/963911 FAX.02/9650314 SERIAL NUMBER DOOR TYPE YEAR OF MANUFACTURE VOLTAGE SUPPLY 00000 0000 000V 00000000000 Made in Italy 6. Cord release installation The cord release on the sectional doors should only be used by skilled personnel, for adjusting the door balancing springs during the installation and maintenance phases. DO NOT USE TO MOVE THE SECTIONAL DOORS MANUALLY. - Fasten the brackets to the gearmotor, then pass the release cord. - Connect the ring and the handle to the release cord. - Fasten the cord connection bracket at a height of at least 2.5m from the ground, to avoid any improper use by unauthorised persons. Attach the WARNING label to the motor. WARNING TRAINED PERSONNEL ONLY EMERGENCY STOP OPEN STOP OPENING HOLD TO UNLOCK min 2500 UNLOCK 45

7. Ditec DOD 12-14-15 installed on sliding door DODRIN1 4x1.5 mm² (motor) 3x0.5 mm² (limitswitch) unlock device E1A E1T OPENING 3x1.5 mm² [-14] 4x1.5 mm² [] Type Pinion Crown Reduction ratio Torque [Nm] Rotating speed [RPM] Door speed [m/s] Max Run [m] Max Force [N] DODRIN1 1:1 45 32 0,16 8,35 900 DODRIN1 1:1 60 22 0,11 8,35 1200 DODRIN1 1:1 65 32 0,16 8,35 1300 46

8. Ditec DOD 12-14-15 with Ditec DOD TC1 installed on sliding door C1 C1 4x1.5 mm² (motor) 3x0.5 mm² (limitswitch) OPENING unlock device E1A E1T 3x1.5 mm² [-14] 4x1.5 mm² [] Type Pinion Crown C1 Reduction ratio Torque [Nm] Rotating speed [RPM] Door speed [m/s] Max Run [m] Max Force [N] 1:1 45 32 0,16 8,35 900 C1 1:1 60 22 0,11 8,35 1200 C1 1:1 65 32 0,16 8,35 1300 47

9. Ditec DOD 12-14-15 installed on folding doors DODRIN1 4x1.5 mm² (motor) 3x0.5 mm² (limitswitch) unlock device E1A E1T OPENING 3x1.5 mm² [-14] 4x1.5 mm² [] Type Pinion Crown Reduction ratio Torque [Nm] Rotating speed [RPM] Door speed [m/s] Max Run [m] Max Force [N] DODRIN1 1:1 45 32 0,16 8,35 900 DODRIN1 1:1 60 22 0,11 8,35 1200 DODRIN1 1:1 65 32 0,16 8,35 1300 i NOTE: for proper operation the door shall be equipped with a derailment device and the chain fastening bracket on the wing must be rotating. 48

10. Ditec DOD 12-14-15 electrical connections Before connecting the power supply, make sure the plate data correspond to that of the mains power supply. An omnipolar disconnection switch with minimum contact gaps of 3 mm must be included in the mains supply. Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout. Wire up the motor to the appropriate electric board terminals. ATTENTION: make sure to connect the motor ground to the ground point. Wire up the limit switches to the appropriate electric board terminals. ATTENTION: (only -14) set DIP2=OFF on E1A control panel. Secure the cable using a special cable clamp. Make sure there are no sharp edges that may damage the power supply cable. Connection to the mains power supply, in the section outside the automation, is made with independent channels and separated from the connections to the control and safety devices. Contatto supplementare Additional switch B Contatto supplementare Additional switch B 12 11 0 Finecorsa apertura Opening limit switch Finecorsa chiusura Closing limit switch A C 12 11 0 Finecorsa apertura Opening limit switch Finecorsa chiusura Closing limit switch A C STOP U V com freno brake M 1~ STOP U V 140 freno brake M 3~ W - ~ W ~ + varistor 460 V Motor cable 4x1.5 mm² UWV 12 11 0 Limit switch cable 3x0.5 mm² E1A Motor cable 4x1.5 mm² UWV 12 11 0 Limit switch cable 3x0.5 mm² E1T 49

10.1 Limit switch adjustment With door open, adjust screw [A] so as to cause the associated cam to trigger the opening limit switch. With door closed, adjust screw [C] so as to cause the associated cam to trigger the closing limit switch. You can decide to adjust the nut [B] so that the relative cam triggers the supplementary contact. WARNING: the supplementary contact can be used for different purposes (i.e. as a safety in order not to exceed maximum stroke in closing and opening, as an exclusion of the sensitive edge after the closing limit switch has been triggered, or for possible acoustic signals or traffic lights). (Only ) make sure that once triggered the opening and closing limit switches actually cause the door to come to a stop. If door continues moving, switch over the L1 and L2 power wiring in the control panel. B A C B C A 50

10.2 Ditec DOD 14PS electrical connections With the provided push button the control panel isn t necessary, the automation works as hold to run function. B Additional switch Black Brown 12 11 A C Opening limit switch Closing limit switch 12B 11B Yellow/Green Grey U V W com M 1~ - ~ ~ + Brake 1,5 m (3x1,5 mm²) 10 m (4x1,5 mm²) 12 11 W 230 V~ / 50 Hz L N i N.B.: If the power supply cable is damaged, refer to the spares price list and contact the Entrematic support service. 51

11. Routine maintenance plan Perform the following operations and checks every 6 months according to intensity of use of the automation. Disconnect the power supply, 230 V~ or 400 V~: - Lubrication of mechanical parts must be performed with door down. - Make sure that cable and spring breakage device is in perfect working order. - Check lift-cable wear. - Make sure that the cables run smoothly in the drums. - Periodically grease the hinges, ball-bearings, wheel pins, and torsional springs. - Check for any obstacles that may hinder the wheels from properly running in the guides. - To check the correct balancing of the sectional automation. - Make sure that the overhead sliding structure is firmly fastened to the ceiling and perfectly free from any defects, bending or buckling. - Make sure that there are no loose bolts or screws. - Absolutely avoid making any changes to the hoisting and/or sliding system. Connect the power supply (230 V~ or 400 V~) and check that: - Limit switches are working properly; - All control and safety functions are in good working order. i i NOTE: for spare parts, see the spares price list. For repairs or replacements of products only original spare parts must be used. The installer shall provide all information relating to automatic, manual and emergency operation of the motorised door or gate, and provide the user with operating instructions. The installer must prepare the maintenance log, which will indicate all the interventions of ordinary and extraordinary maintenance carried out. 52

DITE C S.p.A. V IA MONS. BANFI,3 ITALY 21042 CARO NNO P.LLA (V A) TEL.02/963911 F AX.02/9650314 DOOR TYPE YEAR OF MANUF ACTURE VOLTAGE SUPPL Y 000V 0000 00000000000 00000 SERIAL NUMBER Made in Italy Operating instructions DETACH AND DELIVER TO THE CUSTOMER General safety precautions for the user These precautions are an integral and essential part of the product and must be supplied to the user. Read them carefully since they contain important information on safe installation, use and maintenance. These instructions must be kept and forwarded to all possible future users of the system. This product must only be used for the specific purpose for which it was designed. Any other use is to be considered improper and therefore dangerous. The manufacturer cannot be held responsible for any damage caused by improper, incorrect or unreasonable use. Avoid operating in the proximity of the hinges or moving mechanical parts. Do not enter within the operating range of the motorised door or gate while it is moving. Do not obstruct the motion of the motorised door or gate, as this may cause a dangerous situation. The motorised door or gate may be used by children over the age of 8 and by people with reduced physical, sensorial or mental abilities, or lack of experience or knowledge, as long as they are properly supervised or have been instructed in the safe use of the device and the relative hazards. Do not allow children to play or stay within the operating range of the motorised door or gate. Keep remote controls and/or any other command devices out of the reach of children, to avoid any accidental activation of the motorised door or gate. In the event of a product fault or malfunction, turn off the power supply switch. Do not attempt to repair or intervene directly, and contact only qualified personnel. Failure to comply with the above may cause a dangerous situation. Any repair or technical intervention must be carried out by qualified 53

personnel. Cleaning and maintenance work must not be carried out by children unless they are supervised. To ensure that the system works efficiently and correctly, the manufacturer s indications must be complied with and only qualified personnel must perform routine maintenance on the motorised door or gate. In particular, regular checks are recommended in order to verify that the safety devices are operating correctly. All installation, maintenance and repair work must be documented and made available to the user. Only lock and release the door wings when the motor is switched off. Do not enter within the operating range of the wing. To dispose of electrical and electronic equipment correctly, users must take the product to special recycling centres provided by the municipal authorities. DETACH AND DELIVER TO THE CUSTOMER 54

Manual release instructions WARNING: the sectional door may not be correctly balanced. The release operations and manual movement of the door should be carried out using the DODSBV handle release devices, or the DODSBC chain release devices. In the event of a power supply failure or fault, to manually move the sectional, sliding or folding door you must: - disconnect the power supply and stop the door; HANDLE RELEASE - raise / lower the sectional door using the handle; CHAIN RELEASE - raise / lower the sectional door using the chain; DETACH AND DELIVER TO THE CUSTOMER CORD RELEASE - push the door wing of the sliding or folding door and keep the cord release taut. 1 2 3 WARNING: the door wing block and release operations must be performed with the motor idle. For any problems and/or information, contact the support service. 55

Installer's stamp Operator Date of intervention Technician's signature Customer's signature Intervention performed Installer's stamp Intervention performed Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.ditecentrematic.com Operator Date of intervention Technician's signature Customer's signature For any problems and/or information, contact the Technical Service. DETACH AND DELIVER TO THE CUSTOMER 56

All the rights concerning this material are the exclusive property of Entrematic Group AB. Although the contents of this publication have been drawn up with the greatest care, Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication. We reserve the right to make changes without prior notice. Copying, scanning and changing in any way are expressly forbidden unless authorised in writing by Entrematic Group AB. 57

Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.ditecentrematic.com