Regutec F. Return Lockshield Radiator lockshield

Similar documents
Mikrotherm F. Manual Radiator Valves With presetting

RTL. Floor Heating Controller Return temperature limiter with and without presetting

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

three-way mixing valve

Globo P. Ball valves Pump ball valve made of gunmetal

Floor heating manifold with automatic flow control

TA-6-way valve. Standard control valves 6-way valve for change-over systems

DA 50. Differential pressure controllers Adjustable set-point

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units

STAF-SG. ANSI flanges. Balancing valves DN

dynacon floor heating manifold with automatic flow control

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

STAF-SG. ANSI flanges. Balancing valves Size 3/4-16

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

Pressure independent balancing and control valve For ON/OFF control

TA-PILOT-R. Differential pressure controllers Pilot operated differential pressure controller with adjustable set-point

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

HERZ-Motorised flow controler

Valve bodies type RA-N with integrated presetting

4-way Distribution Valve

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Thermostatic radiator valves with presetting

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

System Components. Potable water Distributors, wall boxes and connections

V2000Kx KV type TRV Body

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

Pressure independent combined control and balancing valves with independent EQM characteristics

KTM 512. Union threads/ansi flanges. Combined control & balancing valves Pressure independent balancing and control valve DN

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

CV 206/216/306/316 GG. Standard control valves 2- or 3-way, DN , cast iron

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

AV 23 Balancing valves SETTER Inline

X-tra Collection for designer radiators and bathroom towel rails

Distributor for Floor Heating Systems

Manual Presetting Valves LENO MSV-B

Lockshield valves with Pressfit connection Type RLV with isulation and regulation

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

RADIATOR VALVE ACCESSORIES

Technical information Thermostatic radiator valves

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

Pressure independent balancing and control valve

EMO TM. Actuators High performance proportional actuator For modulating control

MANIFOLDS AND DISTRIBUTION EQUIPMENT

SOLUTIONS GUIDE. For total efficiency

ACVATIX MiniCombiValves (MCV)

High capacity valve body, type RA-G

Manual presetting valves LENO MSV-BD

Multiflex Fittings. Technical information

X-tra Collection for designer radiators and bathroom towel rails

Floor heating system, heating circuit with FHV-A in flow.

Please refer to our catalogue for details of the full product range

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

ACVATIX MiniCombiValves (MCV)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

Automatic balancing valves ASV-PV DN (3rd gen.)

Ascotherm eco KRP91 Natural convection

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

1/2" /4" " /4" 1 1 /4"

BUN: 3-way valve with male thread, PN 16

Thermostatic valve Type AVTA

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

COMPONENTS FOR SOLAR THERMAL SYSTEMS

3-Port Seat Valves with Male Thread, PN 16

Valencia Radiator Valve Range

4017 M HERZ Dimensions in mm

STRÖMAX-MFS Circuit Control Valve with Measuring Valves Inclined Model

4 01 ta l o g u e 2 Ca P R i c e L I S T

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

Flowmeter DFM

3/2-Way Valve DN 15 up to DN 40

Si 6303 / Si 6304 / Si 6305

Self-operated Temperature Regulators Temperature Regulator Type 1u

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

Overview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems

Fan-coil valves Series

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

3-Port Seat Valves with Male Thread, PN 16

savings flexibility recyclable LIGHTNESS FULL FLOW MECHANICAL STRENGTH IMPROVE CONTROL TECHNICAL BROCHURE aesthetic performance CHANGE

Static Balancing Valve

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT

Technote. Frese ALPHA HCR Dynamic Balancing Valve. Application. Features. Benefits. Design. Installation. Operation.

T6-PLAN CENTRALLY CONNECTED RADIATOR.

k VS DN (mm) Connections ( C) (m 3 /h)

Flow controller (PN 25) AVQ - return and flow mounting

Flow-compensated temperature controller AVTQ DN 15

V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE

CALEFFI. Distribution manifold for radiant panel systems. 664 series 01260/14 GB

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Si Safety valves for pressure relief in accordance to PED, DIN/EN and ASME. Engineering GREAT Solutions

Harmony Installation, Operation and Maintenance

Transcription:

Regutec F Return Lockshield Radiator lockshield

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F Regutec F The Regutec lockshield is used in pumped warm water heating and air conditioning systems. Key features > > Easy to operate with an allan key size 5 AF > > Presettable by means of shut-off and regulation cone Technical description Applications area: Heating and cooling systems. Function: Adjustment Presetting Shut-off Dimensions: DN 10-20 Temperature: Max. working temperature: 120 C Min. working temperature: -10 C Materials: Valve body: Brass O-rings: EPDM rubber Surface treatment: Valve body and fittings are nickel-plated. Standards: Dimensions according to EN 215 series F. Pipe connection: The female-threaded version is designed for connection to threaded pipe, or in conjunction with compression fittings, to copper or precision steel pipe. Not suitable for compression fitting for multi layer pipes. The male-threaded version, in conjunction with the appropriate compression fittings, permits connection to plastic pipe. Construction Regutec F 1. Closing cap 2. EPDM O-ring 3. Shut-off/regulation cone 4. Body made of Brass 2

Application The Regutec F lockshield is used in pumped warm water heating and air conditioning systems. Versions with female thread from DN 10 to DN 20, male thread G3/4 / DN 15 in angle and straight form make the threaded connection suitable for versatile and varied applications. It enables individual shut-off, for example of radiators, so that decorating and service work can be carried out without interruption to the operation of other radiators. A special combination of shut-off/regulation cone and valve seat enables it to be used as a shut-off fitting as well as for hydraulic balance. At the same time, the aim is met of supplying all heaters with hot water according to their requirement. Sample application A B A B 1. Regutec F 2. Thermostatic valve Calypso/Calypso exact or manual radiator valve Mikrotherm F Note To avoid damage and the formation of stones in hot water systems the composition of the heating medium should comply to VDI guidelines 2035. For industrial and long distance energy systems the VdTÜV- Explanatory Leaflet 1466/AGFW-Explanatory Leaflet 5/15 must be observed. Mineral oils, or greases of all types containing mineral oil, in the heating medium lead to severe swelling and, in most cases, to failure of the EPDM seals. When using nitrite-free frost and corrosion protective substances based on ethylene glycol, the appropriate information, especially about the concentration of individual additives, is to be taken from the manufacturer s documentation for frost and corrosion protection. Operation Shut-off The Regutec F lockshield is operated with an allan key size 5 AF. By turning clock-wise the lockshield is closed. If the lockshield has been set for hydraulic balancing, the appropriate number of revolutions during closing has to be determined. It can then be ensured that the initial setting can be set again. Regulation For continuously variable regulation the lockshield is closed with the allan key size 5 AF and then opened by the required number of revolutions. The number of revolutions to set can be determined from the diagrams/technical data. The factory setting as delivered is fully open. 3

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F Technical data Diagram DN 10 (3/8 ) Angle / Straight *) Revolution setting Diagram DN 15 (1/2 ) Angle / Straight *) Revolution setting 4

Diagram DN 20 (3/4 ) Angle / Straight *) Revolution setting DN Kv-value Revolution setting [U] 0,25 0,5 1 1,5 2 2,5 3 3,5 Kvs ζ-value (open) 10 (3/8 ) 0,22 0,37 0,62 0,92 1,19 1,36 1,47 1,58 1,68 13,8 15 (1/2 ) 0,22 0,37 0,62 0,92 1,22 1,43 1,57 1,68 1,74 34,6 20 (3/4 ) 0,22 0,37 0,62 0,92 1,27 1,55 1,72 1,85 1,93 93,2 *) referred to threaded pipe according to DIN 2440. Calculation example Required: revolution setting DN 20 Given: differential pressure to choke off Δp = 34 mbar heat flow Q = 2440 W temperature spread Δt = 15 K (70/55 C) Solution: mass flow m = Q / (c Δt) = 2440 / (1,163 15) = 140 kg/h revolution setting = 1,25 (from diagram) Kv Cv = 0,86 Kv = Cv 0,86 5

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F Articles S3* ) S2* ) Angle H l5 D S1* ) l4 d2 DN D d2 l4 l5 H Kvs EAN Article No 10 Rp 3/8 R 3/8 49 20 39 1,68 4024052969012 0331-01.000 15 Rp 1/2 R 1/2 53 23 43 1,74 4024052969111 0331-02.000 20 Rp 3/4 R 3/4 63 26 48 1,93 4024052969418 0331-03.000 S3* ) S2* ) Angle with male thread G 3/4 H l5 G3/4 S1* ) l4 d2 DN d2 l4 l5 H Kvs EAN Article No 15 R 1/2 53 23 43 1,74 4024052969319 0333-02.000 S1* ) H1 D S3* ) l2 S2* ) d2 Straight DN D d2 l2 H1 Kvs EAN Article No 10 Rp 3/8 R 3/8 75 24 1,68 4024052969517 0332-01.000 15 Rp 1/2 R 1/2 82 24 1,74 4024052969616 0332-02.000 20 Rp 3/4 R 3/4 98 25,5 1,93 4024052969913 0332-03.000 H1 * ) S1 S3* ) S2* ) Straight with male thread G 3/4 G3/4 l3 d2 DN d2 l3 H1 Kvs EAN Article No 15 R 1/2 82 24 1,74 4024052969814 0334-02.000 *) S1: DN10=22mm, DN15=27mm, DN20=32mm S2: DN10=27mm, DN15=30mm, DN20=37mm S3: DN10-20=19mm Kvs = m 3 /h at a pressure drop of 1 bar and fully open valve. 6

Accessories Allen key for operating the Regutec, size 5 AF DIN 911. EAN Article No 4024052115112 0301-05.256 for copper or precision steel pipe according to DIN EN 1057/10305-1/2. Female thread connection Rp 3/8 Rp 3/4. Metal-to-metal joint. Brass nickel-plated. Support sleeves should be used for a pipe wall thickness of 0.8 1 mm. Follow the specifications of the pipe manufacturer. for copper or precision steel pipe according to DIN EN 1057/10305-1/2. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Metal-to-metal joint. Brass nickel-plated. With a pipe wall thickness of 0.8-1 mm insert supporting sleeves. Heed pipe manufacturer s technical advice. Support sleeve for copper or precision steel pipe with a 1 mm wall thickness. Brass. Ø Pipe DN EAN Article No 12 10 (3/8 ) 4024052174614 2201-12.351 15 15 (1/2 ) 4024052175017 2201-15.351 16 15 (1/2 ) 4024052175116 2201-16.351 18 20 (3/4 ) 4024052175215 2201-18.351 Ø Pipe EAN Article No 12 4024052214211 3831-12.351 15 4024052214617 3831-15.351 16 4024052214914 3831-16.351 18 4024052215218 3831-18.351 L Ø EAN Article No 25,0 12 4024052127016 1300-12.170 26,0 15 4024052127917 1300-15.170 26,3 16 4024052128419 1300-16.170 26,8 18 4024052128815 1300-18.170 for copper or precision steel pipe according to DIN EN 1057/10305-1/2. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Soft sealed, max. 95 C. Nickel-plated brass. for plastic pipe according to DIN 4726, ISO 10508. PE-X: DIN 16892/16893, EN ISO 15875; PB: DIN 16968/16969. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Nickel plated brass. Ø Pipe EAN Article No 15 4024052515851 1313-15.351 18 4024052516056 1313-18.351 Ø Pipe EAN Article No 14x2 4024052134618 1311-14.351 16x2 4024052134816 1311-16.351 17x2 4024052134915 1311-17.351 18x2 4024052135110 1311-18.351 20x2 4024052135318 1311-20.351 for Alu/PEX multi-layer pipe according to DIN 16836. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Nickel-plated brass. Ø Pipe EAN Article No 16x2 4024052137312 1331-16.351 7

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regutec F The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. EN Regutec F 10.2016