Mikrotherm F. Manual Radiator Valves With presetting

Similar documents
Regutec F. Return Lockshield Radiator lockshield

RTL. Floor Heating Controller Return temperature limiter with and without presetting

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

Globo P. Ball valves Pump ball valve made of gunmetal

three-way mixing valve

Floor heating manifold with automatic flow control

DA 50. Differential pressure controllers Adjustable set-point

TA-Mini-Fast-Fit. Prefab units Fabricated solutions for small terminal units

STAF-SG. ANSI flanges. Balancing valves DN

TA-6-way valve. Standard control valves 6-way valve for change-over systems

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

dynacon floor heating manifold with automatic flow control

STAF-SG. ANSI flanges. Balancing valves Size 3/4-16

STAF, STAF-SG. Balancing valves PN 16 and PN 25 DN

TA-FUS1ON-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

TA-PILOT-R. Differential pressure controllers Pilot operated differential pressure controller with adjustable set-point

Thermostatic radiator valves with presetting

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

Pressure independent combined control and balancing valves with independent EQM characteristics

Pressure independent balancing and control valve For ON/OFF control

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

KTM 512. Union threads/ansi flanges. Combined control & balancing valves Pressure independent balancing and control valve DN

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

V2000Kx KV type TRV Body

CV 206/216/306/316 GG. Standard control valves 2- or 3-way, DN , cast iron

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

System Components. Potable water Distributors, wall boxes and connections

STRÖMAX-MFS Circuit Control Valve with Measuring Valves Inclined Model

V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

HERZ-Motorised flow controler

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

Pressure independent balancing and control valve

Valve bodies type RA-N with integrated presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

AV 23 Balancing valves SETTER Inline

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

Multiflex Fittings. Technical information

Manual presetting valves LENO MSV-BD

TA-6-way valve. NPT threads. Standard control valves 6-way valve for change-over systems

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

Manual Presetting Valves LENO MSV-B

Pressure operated water valve Type WVFX and WVS

1/2" /4" " /4" 1 1 /4"

RADIATOR VALVE ACCESSORIES

ACVATIX MiniCombiValves (MCV)

High capacity valve body, type RA-G

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

X-tra Collection for designer radiators and bathroom towel rails

Valves, controls + systems Cast iron double regulating/ commissioning valves PN 16 Hydrocontrol G

Installation and operating instructions KEMPER Free-flow combination anti-pollution check valve EA Figure 145/146

Distributor for Floor Heating Systems

4017 M HERZ Dimensions in mm

4-way Distribution Valve

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

TRIM, TRIM A, RADITRIM A, TRIM K, STK, TA Loop

Valves, controllers + systems Double regulating and commissioning valves Hydrocontrol F cast iron, PN 16

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

Automatic balancing valves ASV-PV DN (3rd gen.)

Zeparo G-Force. Automatic air vents and separators Microbubble, dirt and magnetite separator with Cyclonic technology

Ascotherm eco KRP91 Natural convection

Self-operated Temperature Regulators Temperature Regulator Type 1u

Hydrocontrol VFC cast iron, PN 16 Hydrocontrol VFR bronze, PN 16 Hydrocontrol VFN nodular cast iron, PN 25 Double regulating and commissioning valves

Circuit Regulating Valve STRÖMAX GF

EMO TM. Actuators High performance proportional actuator For modulating control

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT

ACVATIX MiniCombiValves (MCV)

X-tra Collection for designer radiators and bathroom towel rails

Thermostatic valve Type AVTA

Valves for building. Y-strainers... page 204 PVC valves Ball valves... page 204 Butterfly valve... page 204 Ball check valve...

Overview of types. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

Valves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...

3-Port Seat Valves with Male Thread, PN 16

Floor heating system, heating circuit with FHV-A in flow.

Si 6303 / Si 6304 / Si 6305

Valencia Radiator Valve Range

Double regulating and commissionig valves Hydrocontrol F cast iron, PN 16 Hydrocontrol FR bronze, PN 16 Hydrocontrol FS nodular cast iron, PN 25

Diaphragm valve MV 309

STV DN 10-50, Balancing valve

CCO kit. Compact Change Over - 6-way switch valve with motor QUICK FACTS

Flow controller (PN 25) AVQ - return and flow mounting

Flow-compensated temperature controller AVTQ DN 15

Technote. Frese ALPHA HCR Dynamic Balancing Valve. Application. Features. Benefits. Design. Installation. Operation.

BUN: 3-way valve with male thread, PN 16

Pressure relief valve DHV 718

SOLUTIONS GUIDE. For total efficiency

2 PIECES BALL VALVE PN63

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

DN 1/4" to 4 Female - Female BSP -10 C + 80 C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Flowmeter DFM

MADE OF STAINLESS...

Valves, controls + systems Valves and controls for solar installations Regusol-180

Harmony Installation, Operation and Maintenance

THERMOSTATIC CONTROL HEADS:

Transcription:

Mikrotherm F Manual Radiator Valves With presetting

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Mikrotherm F The Mikrotherm F manual radiator valve is used in warm water pump heating systems or gravity systems. The non-rising double spindle with the Mikrotherm F presetting cone makes hydraulic balancing through presetting possible. Key features > > Double O-ring sealing > > Consistent presetting through a non-rising double spindle > > Can be retrofitted as a Eclipse F or Calypso exact thermostatic valve Technical description Application area: Heating systems Function: Balancing Pre-setting Shut-off Dimensions: DN 10-20 Pressure class: PN 10 Temperature: Max. working temperature: 120 C Min. working temperature: -10 C Material: Valve body: Brass. O-rings: EPDM rubber. Valve insert: Brass. Handwheel: PP (Polypropylen), tight-packed with protection film, white RAL 9016. Surface treatment: Valve body and fittings are nickel-plated. Marking: THE, country code, flow direction arrow, DN. II+ -Designation. Standards: Dimensions according to DIN EN 215 (Series F). Pipe connection: The female-threaded version is designed for connection to threaded pipe, or in conjunction with compression fittings, to copper or precision steel pipe. Not suitable for compression fitting for multi layer pipes. 2

Construction Mikrotherm F 1. Double O-ring sealing 2. Double spindle 3. Tandem sealing (metal and O-ring sealing) 4. Presetting cone Application The Mikrotherm F manual radiator valve is used in warm water pump heating systems or gravity systems. With models in angle and straight form from DN 10 to DN 20, the manual radiator valve can be used for a number of different purposes. The non-rising double spindle with the Mikrotherm presetting cone makes hydraulic balancing through presetting possible. The aim here is to provide e. g. all heat consumers with hot water according to their needs. Sample application 1. Mikrotherm F 3

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Note The contents of the heat transfer medium should comply with VDI guideline 2035 on damage and scale deposit formation in warm water heating systems. For industrial and long-distance energy systems, see the applicable codes VdTÜV 1466 and AGFW FW 510. Mineral oils in the heat transfer medium or lubricants containing mineral oils of any type lead to strong swelling and in most cases cause EPDM seals to fail. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly details concerning concentration and specific additives. Operation Presetting 1. Close the valve. 2. Unscrew the hand wheel fastening screw. 3. Screw in the control pin with a screw driver (slot size 10 mm x 1.5 mm) by turning it clockwise until it stops. 4. Use the diagrams to determine the presetting and preset by turning to the left. 5. Insert the hand wheel fastening screw and screw tight. The insert should only be loosened or tightened when the valve is opened. 4

Technical data Diagram DN 10 (3/8 ) Angle / Straight 3491-01 / 3492-01 *) Screwdriver rotations Diagram DN 15 (1/2 ) Angle / Straight 3491-02 / 3492-02 *) Screwdriver rotations 5

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F Diagram DN 20 (3/4 ) Angle / Straight 3491-03 / 3492-03 *) Screwdriver rotations Sample calculation Target: Preset value Given: Heat flow Q = 1750 W Temperature spread Δt = 20 K (70/50 C) Pressure loss in manual valve DN 15 Δp V = 20 mbar Solution: Mass flow m = Q / (c Δt) = 1750 / (1,163 20) = 75 kg/h Screw driver turns from diagram DN 15 = 5.5 turns Kv Cv = 0,86 Kv = Cv 0,86 6

Articles Angle H1 l5 * ) SW2 D l3 l4 * ) SW1 d2 DN D d2 l3 l4 l5 H1 Kvs EAN Article No 10 Rp3/8 R3/8 24 49 20 58,5 1,70 4024052952519 3491-01.500 15 Rp1/2 R1/2 26 53 23 58 2,44 4024052952618 3491-02.500 20 Rp3/4 R3/4 30 63 26 56 2,66 4024052952717 3491-03.500 Straight H2 SW1 * ) SW2 * ) D l1 l d2 DN D d2 l1 l2 H2 Kvs EAN Article No 10 Rp3/8 R3/8 50 76 57 1,70 4024052952816 3492-01.500 15 Rp1/2 R1/2 55 83 57 2,44 4024052952915 3492-02.500 20 Rp3/4 R3/4 65 97 57 2,66 4024052953011 3492-03.500 *) SW1: DN 10 = 22 mm, DN 15 = 27 mm, DN 20 = 32 mm SW2: DN 10 = 27 mm, DN 15 = 30 mm, DN 20 = 37 mm Kvs = m 3 /h at a pressure drop of 1 bar and fully open valve. Accessories for copper or precision steel pipe according to DIN EN 1057/10305-1/2. Female thread connection Rp 3/8 Rp 3/4. Metal-to-metal joint. Brass nickel-plated. Support sleeves should be used for a pipe wall thickness of 0.8 1 mm. Follow the specifications of the pipe manufacturer. Support sleeve for copper or precision steel pipe with a 1 mm wall thickness. Brass. Ø Pipe DN EAN Article No 12 10 (3/8 ) 4024052174614 2201-12.351 15 15 (1/2 ) 4024052175017 2201-15.351 16 15 (1/2 ) 4024052175116 2201-16.351 18 20 (3/4 ) 4024052175215 2201-18.351 Ø Pipe L EAN Article No 12 25,0 4024052127016 1300-12.170 15 26,0 4024052127917 1300-15.170 16 26,3 4024052128419 1300-16.170 18 26,8 4024052128815 1300-18.170 Double connection fitting For clamping plastic, copper, precision steel or multi-layer pipes. Brass, nickel-plated. for copper or precision steel pipe according to DIN EN 1057/10305-1/2. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Metal-to-metal joint. Brass nickel-plated. With a pipe wall thickness of 0.8-1 mm insert supporting sleeves. Heed pipe manufacturer s technical advice. L EAN Article No G3/4 x R1/2 26 4024052308415 1321-12.083 Ø Pipe EAN Article No 12 4024052214211 3831-12.351 14 4024052214310 3831-14.351 15 4024052214617 3831-15.351 16 4024052214914 3831-16.351 18 4024052215218 3831-18.351 7

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm F for copper or precision steel pipe according to DIN EN 1057/10305-1/2. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Soft sealed, max. 95 C. Nickel-plated brass. for plastic pipe according to DIN 4726, ISO 10508. PE-X: DIN 16892/16893, EN ISO 15875; PB: DIN 16968/16969. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Nickel plated brass. Ø Pipe EAN Article No 15 4024052515851 1313-15.351 18 4024052516056 1313-18.351 Ø Pipe EAN Article No 12x1,1 4024052136018 1315-12.351 14x2 4024052134618 1311-14.351 16x1,5 4024052136117 1315-16.351 16x2 4024052134816 1311-16.351 17x2 4024052134915 1311-17.351 18x2 4024052135110 1311-18.351 20x2 4024052135318 1311-20.351 for Alu/PEX multi-layer pipe according to DIN 16836. Connection male thread G 3/4 according to DIN EN 16313 (Eurocone). Nickel-plated brass. Eclipse F with automatic flow limitation For thermostatic valve bodies with II+ marking, from 2015. Ø Pipe EAN Article No 16x2 4024052137312 1331-16.351 18x2 4024052137411 1331-18.351 Retrofitting/ EAN Article No Replacement inserts For DN valve 10, 15, 20 4024052940912 3930-02.300 Calypso exact with stepless precision presetting For thermostatic valve bodies with II Retrofitting/ EAN Article No marking, from 2012 and II+ marking, from 2015. Replacement inserts For DN valve 10, 15, 20 4024052841417 3700-02.300 Fitting tool complete with case, box spanner and replacement seals, for replacing thermostatic inserts without draining off the heating system (for DN 10 to DN 20). EAN Article No Fitting tool 4024052298914 9721-00.000 Replacement seals 4024052299010 9721-00.514 1 mm = 0,0394 inch The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. Mikrotherm F ed.3 10.2017