Bevent Rasch BSK6. - Fire /04/2017

Similar documents
Bevent Rasch BSK Fire /04/2017

Fire/smoke damper EKO-JBG2

Fire/smoke damper EKO-SRBG1

Smoke damper EKO-SRB1

Fire/combustion gas damper EKO-JBL

Fire/combustion gas damper EKO-JBG

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Combustion gas damper EKO-SRB

7/S1 FIRE DAMPER PPZEN. v 2.5 (en)

Fire dampers ETCE and ETCS TECHNICAL DATA

7/S6 FIRE DAMPER FDC40. v 2.9 (en)

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

Fire damper FK120/FK90 TECHNICAL DATA

ESAS Smoke control damper

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

NEO. Fire Damper. air handling intelligence FIRE SAFETY FUNCTION

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

WGA Long throw nozzle grille

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

Combustion gas damper EKO-JB

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

ADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

TYPE EK-EU SMOKE CONTROL DAMPER

OPTIVENT Housing HVSA, HVSL

BLBd

M A D E L. FOK-EIS-180 Fire dampers CE

Stainless Steel Chimneys Ducts and Fittings for Air Conditioning & Ventilation

PKIR3G, PKIS, PKIS3G and PKIS3GA

KSOF Fire damper valve

CRP. Commissioning damper, Ductwork Leakage Class 0

DKISMA. Systemair multicompartment rectangular smoke control dampers. Ordering codes. Description. Design. Fire safety products 1 / 8.

Fire damper. Type FKA-3.8. GB/en. Installation and operating manual. according to Declaration of Performance. DoP / FKA-3.

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

VARYCONTROL VAV Dual Duct Terminal Boxes

VOLUME CONTROL / REGULATING DAMPERS

Heights up to 1000 mm Fire resistance period up to 120 minutes

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

ADAPTTM. Sphere. Active communicative, supply air diffuser for the WISE system. Quick Selection

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

ROOFMASTER STEF-HT ROOF FAN

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Lint separator FLARE

Mechanical mixing box MBM

Regulation and shut-off damper SPB and SPC

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

Fire Safety Products. Product Overview

Fire Dampers. Type FDF. Compliant to SABS (193:2004) SA/6/1/EN/3

ADAPTTM. Free. Active communicative, supply air diffuser for the WISE system, ADAPT F

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

HIGH-POWERED VENTILATORS

Fire and Smoke Damper Actuator product overview

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

DCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

SERENO

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

FlowBar High Capacity Slot Diffuser

PKI-C Cartridge Fire Dampers

Smoke control damper RKI-90 Test certificate Z

Sound attenuators. Sound attenuators, Sound attenuating louvres. Sound attenuators. Rectangular sound attenuators DZ-2, DZ-3

FK120/FK90 FIRE DAMPER» INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE

Systemair Fire Dampers

ROOF FAN ROOFMASTER STEC

Fire Dampers Catalogue

MegaBox Product-specific information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Shutter Fire Damper Type FSD GFSD 4/1.1/B/1

ROOFMASTER STEF-ATEX ROOF FAN

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

Fire Damper BSK-RPR. with general building supervisory approval Z

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

DAMPERS LSS - R. N-6230 SYKKYLVEN, NORWAY TEL FAX

Ceiling swirl diffusers with perforated face plate

Technical data. Safety notes

Technical data. Safety notes

ROOFMASTER STEF-HT ROOF FAN

Rectangular fire damper TFER 30. pag. C-10

Air distribution product

ACCESSORIES FOR DUCT FANS

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

BX-1H. Fire Valve FIRE SAFETY FUNCTION APPLICATION DESCRIPTION. in libraries of

Transcription:

Bevent Rasch - Fire - BSK6 11/04/2017 Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product according to 15650:2010 Available in MagiCAD www.bevent-rasch.com

EI60 Quick facts Fire resistance class EI60 / EI60S Sizes from 200 x 200 mm to 800 x 800 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product according to 15650:2010 Available in MagiCAD Use Damper in combination with walls or joist systems for fire separation of heating, ventilation and air conditioning installations in buildings. In accordance with the harmonised European standard EN 15650:2010. In designs according to associated documents, installation instructions and when the damper is used in combination with smoke detectors and monitoring system (MRB), or the like, the spread of fire/combustion gases is prevented. No further action against the spread of fire/combustion gases is required. Performance EC certificate according to EN 15650:2010 0402-CPR-SC1299-13 Classification of fire resistance according to EN 13501-3 EI60 (ve ho i < > o) S For complete classification, see the Declaration of Performance. Installation BSK6 is installed in duct work separating walls or joist systems, according to the adjoining installation instructions. Should not be installed outdoors or in damp areas. BSK6 is always supplied with an electric safety actuator with spring return complete with thermal sensor with pushbutton for local manual operating test. The sensor disconnects the power to the actuator if the temperature exceeds 72 C inside or outside the damper. 24V actuators are always used in connection with the MRB monitoring system. Dampers can also be supplied with electric actuator 230V. Note that the BSK6 damper is always supplied with an actuator. Activation According to Boverket s Building Regulations smoke detectors must be verified according to SS-EN 54-7 to activate dampers. The mandatory thermal sensor closes the damper at 72 C according to ISO 10294-4. Control and monitoring When the damper is used to prevent the spread of fire and combustion gases it must be closed via impulses from the smoke detector. This must be fitted in the ventilation duct in the proximity of the damper or in another suitable location. Smoke detectors are monitored by means of Bevent Rasch s MRB system or the like. The MRB monitoring system also performs automatic operating checks on the damper every 48 hours and is designed so that faults are indicated immediately and the damper closes. See www.bevent-rasch.com for further details. 2 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

EI60 Size From 200 x 200 mm to 800 x 800 mm, in steps of 50 mm. Design BSK6 is supplied complete with factory mounted, maintenance-free, 24V or 230V electric safety actuator with thermal sensor featuring built-in signal contacts to indicate the damper position. Flanged connections. Material and surface finish Casing and components of galvanized steel sheet according to environmental class C3. Fabric seals. Blade and casing of solid fire protection materials. Accessories Connection spigot for spiral duct RBFS Extension spigot for wall/joist systems thicker than 280 mm, and in combination with or wire mesh grilles RBMP Assembly plate, excl. refinishing material (RBBM), for installation in plaster structures EI 60 / EI 120 RCKB Connection box RCDU MRB system, max 2 dampers RCBK4 MRB system, max 4 dampers RCMU8 MRB system, max 8 dampers RCKD/-RD Smoke detectors BRTR Wire mesh grille, rectangular RCTU/RCTC MRB3 system, max 236 dampers Specification Example: - 400-400 - 1-1 Size Width x Height (W x H), mm Material Galvanized sheet steel = 1 Stainless AISI 3041 EN 1.4301 = 2 Stainless AISI 316L EN 1.4404 = 3 Electric 24V with thermal sensor = 1 Electric 230V with thermal sensor = 3 Electric 24V incl. RCTU = 5 Note. Factory fitted actuator always included. BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 3

EI60 Dimensions and weight max*) 128 W 43 A 400 48 125 227 D H 19 Flanged connection *) applies to standard design Dimensions, mm H A D 200 0 0 250 25 0 300 50 0 350 75 0 400 100 0 450 125 0 500 150 0 550 175 0 600 200 20 650 225 45 700 250 70 750 275 95 800 300 120 Weight incl. 24V actuator, kg H 200 250 300 350 400 450 200 12 13 15 16 17 18 20 21 22 24 25 27 28 250 13 15 16 17 18 20 21 22 24 25 27 28 30 300 15 16 17 18 20 21 22 24 25 27 28 30 32 350 16 17 18 20 21 22 24 25 27 28 30 32 33 400 17 18 20 21 22 24 25 27 28 30 32 33 35 450 18 20 21 22 24 25 26 28 30 32 33 35 36 500 20 21 22 24 25 26 28 30 32 33 35 36 38 550 21 22 24 25 26 28 29 32 33 35 36 38 39 600 22 24 25 26 27 29 30 33 35 36 38 39 41 650 24 25 26 27 29 30 31 35 36 38 39 41 42 700 25 26 27 29 30 31 33 36 38 39 41 42 44 750 26 27 29 30 31 33 34 38 39 41 42 44 45 800 27 29 30 31 33 34 35 39 41 42 44 45 47 W 500 550 600 650 700 750 800 Electrical data (values in brackets refer to 230V) type BF... Sizing, max... 10 VA (12.5 VA) Running time: motor opening, max... approx. 120 s - spring return, max... approx. 20 s Protection class... IP 54 Power supply... 24V~ ±20%, 50/60Hz 24V= ±10% (220-240V~, 50/60Hz) Ambient temperature... -30 to +50 C Safety temperature... -30 to +75 C (24 hrs. guaranteed safety) Tripping temperature thermal sensor... 72 C End position contacts - load 300 mw... min 1 ma/5v=, max 100 ma/250v~ After exceeding the above values it applies: - load > 300 mw... min 100 ma, max 3 A/250~ Sound level when opening approx 45 db(a) Sound level when closing approx 62 db(a) Wiring diagram Chart indicates in the de-energized state N L1 1 2 1 2 3 4 5 6 M 5 C 80 O BAE72-S Tf1 Tf2 Thermal sensor 4 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

EI60 Installation Connection spigot Extension spigot RBFS Min. damper size RBFS A L 1 L 2 100 200 x 200 50 125 200 x 200 50 160 200 x 200 50 200 200 x 200 50 250 250 x 250 50 155 315 350 x 350 65 155 400 400 x 400 80 155 500 500 x 500 80 330 630 650 x 650 80 330 155 800 800 x 800 80 330 155 A RBFS *) L 1 /L 2 RBFS RBFS *) L 1 A 400 A *) = 250-500 mm A L 1 400 L 2 A 1 x RBFS required = 630-800 mm 2 x RBFS required *) Length as per the table above Note. For circular dampers first use the BSKC6 damper. Assembly plate (incl. in delivery) 60 60 Duct size W/H + 65 mm Supplied unassembled BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 5

EI60 Technical data Sound data The speed is calculated on the damper s gross area, i.e. a BSK6-400 x 400 has a gross area of 0.16 m 2. The specified pressure drop applies to the damper without accessories. Total pressure drop, Pa Sound power level 75 1 Damper Height < 400 mm 2 Damper Height 400 mm Air speed, m/s Correction of sound power level, L W, for different sizes use curves 1-2 according to: L W = L Wt + K 1 Damper height mm Damper area, m 2 <200 as per 1-0,08 0,16 0,28-400 as per 2 0,08 0,16 0,32 0,64 1,28 K 1-3 0 3 6 9 Correction of sound power level, L ok, in octave band L Wok = L W + K ok Correction, K ok Opening Centre frequency Hz angle 63 125 250 500 1000 2000 4000 8000 90-1 -11-18 -23-26 -28-32 -38 Tol. ± db 1 2 3 4 6 6 6 6 6 BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70

EI60 Installation instruction Building element (wall or joist structure) in fire resistance class EI60. Damper s fire resistance class: EI60 (ve ho i <-> o) S. EC certificate 0402-CPR-SC1299-13 Option 1 Option 2 Horizontal joist, see section 1 Refinish see section 3 (Protective grille, see section 5) Pop rivet mounted from inside and out (Protective grille, see section 5) Refinish see section 3 Fastening lugs Concrete screw 8x5x65 or equivalent approved fastening material W + 50 mm H + 50 mm Min. thickness 125 mm Assembly plate RBMP Drywall insulated with mineral wool 40kg/m 3. Or equivalent with wall fire resistance class EI60. Fastening lugs Screw (Spax 5x45 or equivalent approved fastening material) Min. thickness 95 mm Pop rivet mounted from inside and out W + 50 mm H + 50 mm Assembly plate RBMP Joist of concrete or equivalent fire resistance class EI60 13-0272_ENG / April 2017 mediacad.se Options 1 and 2 1. Aperture equivalent to damper dimensions + 50 mm, is produced in the building element. When mounted in a drywall, horizontal metal joists 45x45 mm shall be applied as a frame in the wall structure. 2. The damper is secured flat and tight using fire stopping sealant (Intumex AN) against the wall/joist structure with the fastening lugs, which are opened out. When mounted in drywall, Spax screws shall be screwed in to the joists. 3. Make sure the gap between damper and wall is 25 mm all around. Sealing is carried out by caulking with mineral wool, min 40 kg/m 3. 4. Fit the assembly plates RBMP on to the building element, using appropriate fastening material. When mounted in drywall, Spax screws shall be screwed in to the joists. Attach the assembly plates on to the damper, using stainless steel pop rivets through the prepunched holes in the assembly plates. Mount the pop rivets from the inside and out. Make sure nothing is obstructing the movement of the damper blade. 5. If fire damper is not connected to the duct system, fit non-combustible grilles designed for the damper on the unconnected sides. Connection piece RBFS may be needed from sizes 600 mm or larger. The minimum distance between the damper blade in the open position and the grille is 50 mm. 6. Install the thermal sensor with the sensor body in the air stream without obstructing the movement of the damper blade. 7. Install the duct system according to applicable requirements. 8. Install the duct system according to applicable requirements. Make sure that the connected duct system does not impact on the damper in the event of a fire load. Minimum distance between dampers must be 200 mm. Minimum distance to joist structure/wall must be 75 mm. Horizontal installation of the damper spindle. BORÅS Tel +46 (0)33-23 67 80 STOCKHOLM Tel +46 (0)8-54 55 12 70 7