CERTIFICATE OF APPROVAL No CF 209 ROYDE & TUCKER LIMITED

Similar documents
CERTIFICATE OF APPROVAL No CF 5505 CONSORT ARCHITECTURAL HADWARE LTD

CERTIFICATE OF APPROVAL No CF 5418 C.ED. SCHULTE GMBH

CERTIFICATE OF APPROVAL No CF 5543 ASSA ABLOY SECURITY SOLUTIONS

CERTIFICATE OF APPROVAL No CF 5267 SHERWIN-WILLIAMS

CERTIFICATE OF APPROVAL No CF 5069 HILTI AG

CERTIFICATE OF APPROVAL No CF 681 INTERNATIONAL PAINT LIMITED

CERTIFICATE OF APPROVAL No CF 557 JOTUN PAINTS (EUROPE) LIMITED

CERTIFICATE OF APPROVAL No CF 700 RUDOLF HENSEL GMBH

CERTIFICATE OF APPROVAL No CF 574. Sika Deutschland GmbH

CERTIFICATE OF APPROVAL No CF 249. Yung Chi Paint & Varnish Mfg. Co., Ltd

CERTIFICATE OF APPROVAL No CF 5235 AVIANS INNOVATIONS TECHNOLOGY PVT. LTD

CERTIFICATE OF APPROVAL No CF 5172 ETEX BUILDING PERFORMANCE LTD

CERTIFICATE OF APPROVAL No CF 119 DORMA UK LTD

13 th December Title: The Fire Resistance Performance Of Doorsets When Fitted With Perko Powermatic R100 Jamb Mounted Concealed Door Closers

RTS 87 RTS 80EMB RTS 80FLB

TS90 IMPULSE. Cam action door closer

Door Closer DORMA TS72 VBC

Door Closer DORMA TS 72

Door Controls. Door. Controls

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for:

Concealed cam-action door closer system DORMA ITS 96

Briton Briton 121CE Briton 121 Series

CERTIFICATE OF APPROVAL No ME 5079

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

Lloyd s Register Type Approval System Test Specification Number GT04

Introduction. Our Ref: Chilt/IF12041 AR1. 24 th June Astra Door Controls Ltd Unit 10 Astra Business Centre Roman Way Preston PR2 5AP

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

High Performance Door Products. Information Guide Ironmongery.

THE IDEAL SOLUTION FOR DOORS UP TO 1100MM WIDE TESTED AND APPROVED TO EN 1154

Briton 2000 Series - a compact series of closers designed for the most common door sizes

Evidence of Performance Burglar resistance

CARES Technical Approval Report TA1B


EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

Door Closers Contents

CARES Technical Approval Report TA1C

Cylinders. Hinges. Bolts

Report No 2370/ This Report consists of 40 pages. Authority & date Request by Client dated 25 November 2010

EC-CERTIFICATE OF CONFORMITY 0432 CPD 0031

SSDC overhead closer

880 series exit hardware

No e This is a translation of Test Report Summary dated 23 April 2007.

EN A harmonised standard designed for life safety

SOUTH AFRICAN NATIONAL STANDARD

DOOR CONTROLS ARCHITECTURAL DOOR CONTROLS & ACCESSORIES

Code no STRONG STAINLESS STEEL BUTT HINGES

Door Controls/by John Planck

Fire Doors. Safety, Union and Design

Enigma. Pocket sliding door systems. Wall construction preparation guide

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E

Construction Safety Amendment (Amusement Devices) Regulation 1998

ETPS-EI Fire Damper EI 60 S / EI 120 S Instructions for Installation, Operation and Maintenance

Door Closer Range ARCHITECTURAL IRONMONGERS SECURITY SPECIALISTS

Door Closer range ARCHITECTURAL IRONMONGERS SECURITY SPECIALISTS St. Benedicts Street, Norwich, NR2 4PD Tel:

Cavity Stop Socks & TCBs

Touch Temperature LST

TS 73 EMF. Hold-open system

Cam-action door closers DORMA TS 92 TS 91

By Carlisle Brass The Home of Quality Architectural Ironmongery

ACO Water Management: Civils + Infrastructure

Allegion - Introduction to Products & Service

HOUSE BILL NO. HB0235. Sponsored by: Representative(s) Roscoe and Miller A BILL. for. AN ACT relating to motor vehicles; providing that the

PRINTOUT MAY NOT BE UP-TO-DATE; REFER TO METRO INTRANET FOR THE LATEST VERSION

4 Door Closers Ä o ²»

THE PETROLEUM REGULATION ACTS (NI) 1929 & 1937

TYPE-CERTIFICATE DATA SHEET

AIR LUBRICATION SYSTEM INSTALLATION

TYPE-CERTIFICATE DATA SHEET

DITCH KING & DITCH BOSS. Tractor Mounted Digger. Operation & Parts Manual

ISO 3934 INTERNATIONAL STANDARD

Cam action door closers. Product overview

Offshore manufacturing and fabrication: guidelines for heavy trailers (class TC and TD)

CI/SfB. Xt7. Door closers

System Test Report Fitness for Use and Durability

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

TS 92 TS 91. Cam-action door closers in Contur Design

INT Multipoint Range. Tindall Engineering Limited is registered in England and Wales - Company Number

13 th Military Airworthiness Conference 25 th September 2013 EASA Presentation. Pascal Medal Head Of Certification Experts Department EASA

Conformity of Production Compliance Statement

FUNCTIONAL SAFETY CERTIFICATE

Allegion - Introduction to Products & Service

STEEL SECURITY DOORS. Standard Duty

TYPE-CERTIFICATE DATA SHEET

CERTIFICATION MEMORANDUM

COMMISSION REGULATION (EU) / of XXX

Technical Data. Insulation for the LNG, Petrochemical and Process Industries

PSU EN54-4 Power Supplies

Melody 1 Platform Lift

Structural steel equal and unequal leg

Manufacturer of marine doors and windows since Product manual. Photo Harald Pettersen - Statoil.

Understanding BS 1363 Amendment No.4

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface

Panic Hardware DORMA PHA 2000 PHB 3000

TYPE-CERTIFICATE DATA SHEET

Cam action door closers. Product overview

PAM NEW WORLD CENTER IRONMONGERY MATERIAL REFERENCE SHEET. Tender Addendum No.2

TS 83. Easy-action Door Closer

MCS. Important Information on MCS 012 Issue 2.1 for MCS Solar Photovoltaic and Solar Thermal Contractors. Last Updated: 25 th September 2017

EN Standards Overview

Transcription:

CERTIFICATE OF APPROVAL No CF 209 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Bilton Road, Cadwell Lane, Hitchin, Hertfordshire, SG4 0SB Tel: 01462 444444 Fax: 01462 444433 Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions appended hereto: CERTIFIED PRODUCT Hi-Load Hinges Traditional Series TECHNICAL SCHEDULE TS24 The Contribution of Single Action Hinges to the Fire Resistance of Door Assemblies Signed and sealed for and on behalf of CERTIFIRE Sir Ken Knight Chairman - Management Council Page 1 of 6

1. This approval relates to the use of the above single axis hinges in contributing to the fire resistance performance of timber based doorsets, for periods of 30 or 60 minutes integrity and insulation, as defined by BS EN 1634-1:2000, BS EN 1634-1:2008 or BS 476 : Part 22 : 1987. Subject to the undermentioned conditions, the doorsets will meet the relevant requirements of BS 5588 for doorsets when used in accordance with the provisions therein. 2. This certification is designed to demonstrate compliance of the product or system specifically with Approved Document B (England and Wales), Section D of the Technical Standards (Scotland), Technical Booklet E (N. Ireland). If compliance is required to other regulatory or guidance documents there may be additional considerations or conflict to be taken into account. 3. The hinges are approved on the basis of: i) Initial type testing to EN1935 and testing/appraisal to EN 1634-1: 2000. ii) A design appraisal against TS24 iii) Production surveillance under BS ISO 9001: 2008 iv) On-going audit testing in accordance with BS EN 1935 requirements v) Inspection and surveillance of factory production control 4. The traditional series hinges comprise a range of single axis, self-lubricating hinges, which may be of various sizes for use on various classes of doorsets. The hinges are a minimum of Class 10 in accordance with BS EN 1935: 2002. 5. This certification relates to the following variants of Hi-load traditional series hinges: H086 Lift off hinge Maximum leaf weight 60 kg H100 Butt hinge - Maximum leaf weight of 100 kg H101 Lift-off hinge - Maximum leaf weight of 80 kg H102 Butt hinge - Maximum leaf weight of 120 kg H102-0 Butt hinge - Maximum leaf weight of 120 kg H102-1 Butt hinge - Maximum leaf weight of 120 kg H102-5 Butt hinge - Maximum leaf weight of 120 kg H103 Butt hinge - Maximum leaf weight of 100 kg H104 Butt hinge - Maximum leaf weight of 80 kg H105 Lift off hinge - Maximum leaf weight of 80 kg H107 Lift off hinge - Maximum leaf weight of 120 kg H1254-A Projection hinge - Maximum leaf weight of 100 kg H1254-B Projection hinge - Maximum leaf weight of 100 kg H1254 Butt hinge - Maximum leaf weight of 100 kg H1250 Butt hinge - Maximum leaf weight of 100 kg H102-A Projection hinge - Maximum leaf weight of 120 kg H102-B Projection hinge - Maximum leaf weight of 120 kg H102-300 Anti-ligature hinge - Maximum leaf weight of 120 kg H125-300 Anti-ligature hinge - Maximum leaf weight of 120 kg Page 2 of 6 Signed

6. This approval relates to the above hinges used with latched or unlatched single-leaf or double-leaf door assemblies consisting of timber faced and edged leaves with timber, cellulosic or mineral cores and in timber frames (Code ITT) not less than 44 mm thick. The door frame shall consist of timber with a minimum density of 460 kg/m³ for FD20/E20/EI20 or FD30/E30/EI30 applications. The door frame shall consist of a timber with a density in excess of 650 kg/m³ for FD60/E60/EI60 doorsets. 7. Both blades of the hinges must be bedded onto 1mm-thick Interdens when used with TT or ITT doorsets for 30 and 60 minute applications. 8. The hinges may only be fitted to previously tested timber door assemblies when fitted in the manner described in this certificate and when particular aspects of the door assembly are maintained. 9. Hinges shall only be fitted using the fixings supplied by the hinge manufacturer. 10. The doorset, including door frame and associated building hardware, should be either CERTIFIRE approved for the relevant application and classification or the doorset, including door frame and associated building hardware, should have achieved at least 30 or 60 minutes fire resistance as required when tested, or subsequently assessed to BS EN 1634-1: 2000, BS EN 1634-1:2008 or BS 476: Part 22: 1987. In either case regard should be paid to the maximum door mass permitted to be used with the hinge (see classification). 11. The doorset shall be installed in accordance with BS 8214: 2008. 12. The approval relates to on-going production. Product and/or its immediate packaging is identified with the manufacturer s name, the product name or number, the CERTIFIRE name or name and mark, together with the CERTIFIRE certificate number and application where appropriate. Page 3 of 6 Signed

Matrix of acceptable doorset types Approved Door Type Class IMM MM TT ITT ITM ITC FD20 FD30 FD60 * FD120 FD240 E 20 EI 20 E 30 EI 30 E 60 * EI 60 * E 90 EI 90 E 120 EI 120 E 240 EI 240 Key: - approved - Not approved * H1254-A, H1254-B, H102A & H102B hinges are not approved for FD60, E60 or EI60 applications. Page 4 of 6 Signed

Scope of Approval: H1254-A, H1254-B, H102A & H102B hinges are only approved for applications up to FD30, E30 and EI30 with ITT doorsets. The hinges may be fitted to doorsets without intumescent protection for up to 20 minutes integrity. All applications apply to glazed and unglazed doorsets. Both blades of the hinges must be bedded onto 1mm-thick Interdens when used with ITT doorsets for FD30/E30/EI30/FD60/E60/EI60 applications. The door frame of TT and ITT doorsets shall consist of timber with a minimum density of 460 kg/m³ and 650 kg/m³ (with leaf to frame gaps less than 3mm) for 30 and 60 minute applications respectively. Classification codes The approval provides the following classifications: H086 Maximum leaf weight 60 kg 2 7 3 1 1 2 0 10 H100 Maximum leaf weight 80 kg H101 Maximum leaf weight 80 kg 3 7 4 1 1 4 0 11 H102, H102-0, H102-1, H102-5, H102A, H102-B & H102-300 Maximum leaf weight 120 kg 4 7 6 1 1 2 0 13 H103 Maximum leaf weight 80 kg Page 5 of 6 Signed

Classification codes continued H104 Maximum leaf weight 60 kg 3 7 4 1 1 2 0 11 H105 Maximum leaf weight 80 kg 3 7 4 1 1 2 0 11 H107 Maximum leaf weight 120 kg 4 7 6 1 1 2 0 13 H1254B & H1254A Maximum leaf weight 100 kg H1254 & H1250 Maximum leaf weight 100 kg H125-300 Maximum leaf weight 100 kg 4 7 6 1 1 2 0 12 Further Information Further information regarding the details contained in this certificate may be obtained from Royde & Tucker Limited (Tel: 01462 444444). Further information regarding the CERTIFIRE certification and other approved products can be obtained from CERTIFIRE (Tel: 01925 646777). Page 6 of 6 Signed