UIN B. Diesel Engine E141. Unit No. Unit: Make Model Serial No.

Similar documents
LUBRICANT (OIL) ANALYSIS COMPARISON

Tec Check. Fluid Analysis Program

MONITORING SOLUTION FOR MARINE MAIN ENGINE CYLINDERS PROTECTION

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

FLUID ANALYSIS PROGRAM

4 A village survey: Mandari, Lakshmipur

Shell IMAA Workshop Making Sense of Oil Analysis

ENGINEERED LUBRICANTS CO.

OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER

MiniLab EL Series for High Performance Engine Development and Maintenance

SERVICE. Condition Monitoring Service Oil Check Condition Monitoring. Lubricant analysis Schwingungsanalyse Vibration SmartCheck

MiniLab EL Series for High Performance Engine Development and Maintenance

3/15/2017. Oil Analysis: When the Oil Speaks, You Should Listen! Oil Analysis. Common Wear Metals Found in Oil. Common Wear Metals Found in Oil

Oil secure power and performance

Techenomics Oil Analysis Information

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test

Rexro h. Service Visit Report. Bosch Group. For the attention of. Site Address: Aviemore, PH22 1RB. Customer Order Number: Visit Date:

Container MBW12K90MC Thursday 25 Jan 2007

Joint Oil Analysis Program Spectrometer Standards VHG Labs Inc. Qualification Report For D19-0, D3-100 and D12-XXX Series Standards

Oil High-capacity and full of power reserve by premature check

OIL PT. Scheme Description. Oils and Fuels Analysis Proficiency Testing Scheme

Standard Analysis Report

INTERPRETATION OF USED COOLANT ANALYSIS

What can the Hartland Fluid Analysis Program Do For You?

Fleet Solutions for Lubricant & Fluid Analysis

Radionuclide atomic number A 1 (TBq) A 1 (Ci) A 2 (TBq) A 2 (Ci) (TBq/g) (Ci/g) Ac-225 Actinium(89) x x

SOME OTHER BENEFITS DERIVED FROM LUBE OIL ANALYSIS ARE:

Joint Oil Analysis Program Spectrometer Standards SCP Science (Conostan) Qualification Report For D19-0, D3-100, and D12-XXX Series Standards

PM 2.5 Impacts From Ship Emissions in the Pacific Northwest. Robert Kotchenruther Ph.D. EPA Region 10 NW-AIRQUEST Meeting, June

Certificate of Accreditation

lubricants analysis. complete solutions for your lab. Lubricants Analysis

Establishing Proper Lubricant Service Intervals For Fleet Applications A Case Study by Dave Yunkers, Analysts, Inc.

Penske Truck Leasing Oil, Fuel & Coolant Sampling Manual

Engine Oil Analysis. John C. Hildreth July 25, 2017

Advanced Petrochemical Applications With ICP-OES. Tina Harville, Ph.D. Application Engineer

Water analysis, QC and more:

Oil Bypass Filter Technology Evaluation Ninth Quarterly Report October December 2004

Machine and Lubricant Condition Monitoring for Extended Equipment Lifetimes and Predictive Maintenance at Power Plants Abstract 1.

Discipline Chemical Testing Issue Date Certificate Number T-3037 Valid Until Last Amended on - Page 1 of 6

The Role of Chemical Metrology in Transportation Industry

Analysis of Wear Metals Using the Teledyne Leeman Labs Prodigy Plus ICP-OES

Fundamentals of Oil Analysis

Agenda. DEF Presentation Turn-Key DEF Solutions. Q & A Wrap-up and Depart

OIL ANALYSIS PROGRAM USER GUIDE LUBEWATCH CHEVRON SERVICES CAN HELP YOU RUN BETTER LONGER

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

TEST REPORT Report No.: R-cn E-S2 Page 1 of 9

Analysis of Petroleum Samples Using the Teledyne Leeman Labs

Condition Based Maintenance System for Heavy Equipments Case study: Using Trend Analysis in Oil Monitoring

LabTec Fluid Analysis Program

TRAFFIC VOLUME TRENDS

224 Sulfur Standards 224 Biodiesel 225 Crude Oil 225 Diesel 225 Isooctane 226 Mineral Oil 226 Residual Oil SCP SCIENCE

TRACE ELEMENTS IN URINE. Event #3, 2012

Envirochem Testing Lab & Research Centre, Plot No. 165, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Ecosteps Laboratory Pvt. Ltd., D-79, Sector-6, Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

JOINT OIL ANALYSIS PROGRAM MANUAL

International Quality Assurance Exchange Program Schedule. Fuel Month Number Type Dispatch Date Closing Date

TRACE ELEMENTS IN URINE

Sequence VH Report Forms Version Conducted For

Anglomoil Hydraulic BIO-FR was designed to replace anti-wear, mineral oil based hydraulic fluids used in applications where fire hazards exist.

API Engine Oil Licensing and Certification System. API Lubricants Group November 2012

Blade Fuses - Illuminated Mini Blade

Diego Navarro. Condition Based Maintenance Consultant ME, OMA I

STUDY OF RE-REFINED OIL USE IN DIESEL ENGINES: FINAL REPORT

ControllingSiliconandSootContentintheCrankCaseOiltoImprovePerformanceofDieselEngine

10.6 Scope of Accreditation

SAMPLING CONTAINERS & HOLDING TIMES. Parameters Method Holding Time 8 Minimum Volume Water Sampling Water Soil Water Soil Container Preservative 9

Daily Trends and Source Apportionment of Ultrafine Particulate Mass (PM 0.1 ) Over an Annual Cycle in a Typical California City

2013 Migration Patterns traffic flow by state/province

/10 EN. Lubricating Oil for MWM Gas Engines. Technical Bulletin. The 10th replacement is made because of:

SEA-Mate Analyser and Blender

Certificate of Accreditation

10.6 Schedule of Accreditation

Test Report. Final conclusion: PASS SHA18. Gohandmade Dsign International A/S HANNE Madevej Aabenraa DENMARK

2016 Migration Patterns traffic flow by state/province

Oil Soluble Polyalkylene Glycol Hydraulic Fluid: Equipment Performance Testing and Case Study

Petrochemical standards

Certificate of Accreditation

Non-Varnishing PAG-based Turbine Fluid and GEK Spec 32568h Recommendations. Govind Khemchandani, Ph. D. The Dow Chemical Company Freeport, TX, USA

APPENDIX D WATER QUALITY DATA

Mack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For

CALIBRATION AND VERIFICATION STANDARDS. The benchmark for accurate measurements. Cerium Standards Sulfur-in-Oil Standards Viscosity Standards NEW

Sampling kits and test suites

Mr. Gabriel Ojeda Fritz-Pak Corporation Phone: (214) Eastover Circle Fax: (214)

CERTIFICATE VO SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Supply of Services for Detailed OEB Crude Assay Analysis

CALIBRATION AND VERIFICATION STANDARDS

Application for Energy and Fuels

Cat S O S Services. Understanding Your Results. Understanding Your: S O S Reports S O S Oil Results S O S Coolant Results S O S Fuel Results

QC CERTIFICATE SD SAMPLE PREPARATION ANALYTICAL PROCEDURES. Signature: Colin Ramshaw, Vancouver Laboratory Manager

1 Alloy specification of standard sacrificial anodes BOLT-ON ANODES / DISC ANODES

National Routing Number Administration p-ani Activity and Projected Exhaust Report

Wear Element Monitoring by Spectrometric Analysis in Automatic Transmission Bus

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Introduction Engine Test Solutions Industrial Plant Solutions Fleet Maintenance Solutions

Calibration & Verification Standards

TRAFFIC VOLUME TRENDS July 2002

MnI Diesel, LLC MnI Maintenance, LLC. Setting the Standard in Oil Filtration Keep It Clean! & Keep It Green!

Test Method D5967 Mack T-8. Version. Method: Conducted For

All Applicants - By HS GPA Run Date: Thursday, September 06, Applicants GPA Count % of Total

Transcription:

DATE SAMPLED 16-May-15 15-Apr-15 15-Mar-15 03-Mar-15 15-Feb-15 15-Jan-15 DATE RECEIVED 22-May-15 23-Apr-15 23-Mar-15 09-Mar-15 20-Feb-15 22-Jan-15 DATE REPORTED 26-May-15 24-Apr-15 24-Mar-15 11-Mar-15 23-Feb-15 25-Jan-15 Unit No. Unit: Site Compartment: Name Capacity: Customer: DISCOVERER UIN 010369B Diesel Engine E141 LLA00495 Discoverer Generator 1 Engine Caterpillar 3512C LLA00495 84.0 gal DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO. 44021195847 44021176867 44021158670 44021148784 44021139699 44021121234 SIF NO. 18456287 18315438 18179920 18118105 18040939 92391365 TIME ON UNIT Hrs 46238 45718 45248 44971 44638 44178 TIME ON OIL Hrs 507 3735 3265 3006 2673 2213 OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED gal FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) 6 36 22 23 16 13 Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) <1 3 6 3 4 2 Copper (Cu) 1 6 4 4 5 3 Tin (Sn) <1 <1 <1 3 <1 1 Aluminium (Al) <1 <1 1 1 1 1 Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) 3 3 2 3 2 1 Sodium (Na) 5 8 8 16 9 6 Potassium (K) 5 6 <5 <1 7 <5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) 894 950 807 751 722 762 Calcium (Ca) 1200 1289 1137 1092 1014 1070 Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) 1088 1157 995 917 858 911 Zinc (Zn) 1283 1358 1249 1145 1066 1145 Molybdenum (Mo) 47 49 43 41 38 38 Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) 12.7 12.4 12.9 12.4 12.5 12.7 Fuel (%) 1 2 1 2 2 1 Soot (%) Infrared 0.3 0.6 1.0 0.3 0.5 0.3 Physical / Chemical Base Number (mgkoh/g) 7.7 5.4 5.8 5.9 6.3 6.8 ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 1

UIN 010369B U.S. Laboratories Atlanta, Georgia - 420 Valley View, Ohio - 410 3121 Presidential Drive Atlanta, GA 30340 800.394.3669 Kansas City, Kansas - 430 935 Sunshine Road Kansas City, KS 66115 800.332.8055 Portland, Oregon - 401 4943 NW Front Avenue Portland, OR 97210 800.770.4128 Canadian Laboratories Burlington, Ontario - 450 1240 Burloak Drive, Unit 6 Burlington, ON L7L 6B3 877.732.9559 Edmonton, Alberta - 402 10717-176 Street Edmonton, AB T5S 1K1 888.489.0057 6180 Halle Dr. Suite D Valley View, OH 44125 800.726.5400 Phoenix, Arizona - 440 3319 West Earll Drive Phoenix, AZ 85017 800.445.7930 Sparks, Nevada - 400 1375 Greg Street, Suite 104 Sparks, NV 89431 800.524.7848 Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold 11777 Katy Freeway Houston Tx 77079 USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas 10450 Stancliff Road, Suite 210 Houston, TX 77099 877.835.8437 International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 2

DATE SAMPLED 16-May-15 15-Apr-15 01-Apr-15 15-Mar-15 15-Feb-15 15-Jan-15 DATE RECEIVED 22-May-15 23-Apr-15 08-Apr-15 23-Mar-15 20-Feb-15 22-Jan-15 DATE REPORTED 26-May-15 24-Apr-15 10-Apr-15 25-Mar-15 23-Feb-15 26-Jan-15 Unit No. Unit: Site Compartment: Name Capacity: Customer: DISCOVERER UIN 0103693 Diesel Engine E142 LLAOO473 Discoverer Generator 2 Engine Caterpillar 3512C LLAOO473 DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO. 44021195848 44021176868 44021167139 44021158671 44021139700 44021121232 SIF NO. 18456289 18315439 18251904 18179922 18041061 92391366 TIME ON UNIT Hrs 46304 45689 45483 45268 44728 44136 TIME ON OIL Hrs 459 3783 3377 3362 2822 2230 OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) 4 38 31 26 16 13 Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) <1 3 <1 3 6 1 Copper (Cu) 1 8 8 6 5 4 Tin (Sn) <1 <1 <1 <1 <1 1 Aluminium (Al) <1 1 <1 <1 1 1 Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) 2 3 3 3 3 <1 Sodium (Na) 2 7 3 6 15 5 Potassium (K) 3 7 <1 <5 6 <5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) 659 949 814 794 707 802 Calcium (Ca) 885 1299 1335 1103 997 1134 Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) 802 1169 993 971 846 949 Zinc (Zn) 958 1385 1244 1227 1039 1205 Molybdenum (Mo) 34 49 40 42 36 40 Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) 12.7 12.3 12.4 12.1 13.0 12.8 Fuel (%) 1 2 2 2 1 1 Soot (%) Infrared 0.3 0.6 0.7 0.4 0.3 0.2 Physical / Chemical Base Number (mgkoh/g) 7.5 5.4 5.6 5.3 6.6 3.7 ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 3

UIN 0103693 U.S. Laboratories Atlanta, Georgia - 420 Valley View, Ohio - 410 3121 Presidential Drive Atlanta, GA 30340 800.394.3669 Kansas City, Kansas - 430 935 Sunshine Road Kansas City, KS 66115 800.332.8055 Portland, Oregon - 401 4943 NW Front Avenue Portland, OR 97210 800.770.4128 Canadian Laboratories Burlington, Ontario - 450 1240 Burloak Drive, Unit 6 Burlington, ON L7L 6B3 877.732.9559 Edmonton, Alberta - 402 10717-176 Street Edmonton, AB T5S 1K1 888.489.0057 6180 Halle Dr. Suite D Valley View, OH 44125 800.726.5400 Phoenix, Arizona - 440 3319 West Earll Drive Phoenix, AZ 85017 800.445.7930 Sparks, Nevada - 400 1375 Greg Street, Suite 104 Sparks, NV 89431 800.524.7848 Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold 11777 Katy Freeway Houston Tx 77079 USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas 10450 Stancliff Road, Suite 210 Houston, TX 77099 877.835.8437 International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 4

DATE SAMPLED 16-May-15 15-Apr-15 15-Mar-15 15-Feb-15 06-Feb-15 15-Jan-15 DATE RECEIVED 22-May-15 23-Apr-15 23-Mar-15 20-Feb-15 17-Feb-15 22-Jan-15 DATE REPORTED 26-May-15 24-Apr-15 24-Mar-15 23-Feb-15 19-Feb-15 25-Jan-15 Unit No. Unit: Site Compartment: Name Capacity: Customer: DISCOVERER UIN 0103620 Diesel Engine E140 LLAOO483 Discoverer Generator 3 Engine Caterpillar 3512C LLAOO483 84.0 gal DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO. 44021195849 44021176869 44021158672 44021139701 44021137404 44021121231 SIF NO. 18456292 18315440 18179923 18041063 18026778 16685460 TIME ON UNIT Hrs 46186 45689 45020 44780 44567 44250 TIME ON OIL Hrs 3661 3164 2495 2255 2040 1725 OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED gal FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) 47 44 32 26 32 28 Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) 4 3 8 3 4 2 Copper (Cu) 10 9 7 6 6 7 Tin (Sn) <1 <1 <1 <1 <1 1 Aluminium (Al) 1 <1 1 2 1 1 Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) 3 3 3 3 2 2 Sodium (Na) 11 10 8 11 10 7 Potassium (K) 3 7 <5 10 <1 <5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) 848 927 789 693 713 766 Calcium (Ca) 1184 1278 1092 986 985 1099 Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) 958 1115 955 835 865 910 Zinc (Zn) 1202 1334 1218 1030 1023 1146 Molybdenum (Mo) 44 47 42 36 36 39 Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) 12.9 12.6 12.6 12.8 12.2 13.2 Fuel (%) 1 2 1 1 2 1 Soot (%) Infrared 0.4 0.7 0.4 0.6 0.2 0.3 Physical / Chemical Base Number (mgkoh/g) 4.5 5.3 5.3 6.1 5.2 5.2 ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 5

UIN 0103620 U.S. Laboratories Atlanta, Georgia - 420 Valley View, Ohio - 410 3121 Presidential Drive Atlanta, GA 30340 800.394.3669 Kansas City, Kansas - 430 935 Sunshine Road Kansas City, KS 66115 800.332.8055 Portland, Oregon - 401 4943 NW Front Avenue Portland, OR 97210 800.770.4128 Canadian Laboratories Burlington, Ontario - 450 1240 Burloak Drive, Unit 6 Burlington, ON L7L 6B3 877.732.9559 Edmonton, Alberta - 402 10717-176 Street Edmonton, AB T5S 1K1 888.489.0057 6180 Halle Dr. Suite D Valley View, OH 44125 800.726.5400 Phoenix, Arizona - 440 3319 West Earll Drive Phoenix, AZ 85017 800.445.7930 Sparks, Nevada - 400 1375 Greg Street, Suite 104 Sparks, NV 89431 800.524.7848 Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold 11777 Katy Freeway Houston Tx 77079 USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas 10450 Stancliff Road, Suite 210 Houston, TX 77099 877.835.8437 International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 6

DATE SAMPLED 15-May-15 02-Mar-15 15-Feb-15 15-Jan-15 15-Dec-14 15-Nov-14 DATE RECEIVED 22-May-15 12-Mar-15 26-Feb-15 21-Jan-15 06-Jan-15 20-Nov-14 DATE REPORTED 26-May-15 13-Mar-15 03-Mar-15 23-Jan-15 08-Jan-15 22-Nov-14 Unit No. Unit: Site Compartment: Name Capacity: Customer: PRIDE UIN 01035DD Diesel Engine E159 LLA02761 Pride Generator 1 Engine Caterpillar 3512C LLA02761 DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO. 44021195850 44021151268 44021143920 44021120568 44021108950 44021083875 SIF NO. 18456294 18133527 18071337 16674372 16601127 16419432 TIME ON UNIT Hrs 32233 31918 31558 30877 30195 29586 TIME ON OIL Hrs 315 4000 3611 2945 2263 1654 OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) 6 28 27 24 16 15 Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) <1 7 9 3 3 3 Copper (Cu) 1 5 4 5 4 3 Tin (Sn) <1 <1 2 <1 <1 <1 Aluminium (Al) 1 <1 <1 2 1 1 Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) 3 3 2 5 3 5 Sodium (Na) 5 10 <1 5 <1 5 Potassium (K) 2 5 <1 <1 <5 6 Coolant No No No No No No Additives (ppm) Magnesium (Mg) 843 746 974 841 848 834 Calcium (Ca) 1172 1055 1433 1214 1216 1130 Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) 1049 810 1195 963 984 1105 Zinc (Zn) 1217 1033 1423 1201 1175 1312 Molybdenum (Mo) 44 29 51 40 41 43 Boron (B) <5 <5 <5 <5 <1 6 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) 13.3 13.0 13.1 12.8 13.0 13.1 Fuel (%) 1 1 1 1 1 1 Soot (%) Infrared 0.4 0.4 0.3 0.3 0.4 0.3 Physical / Chemical Base Number (mgkoh/g) 7.5 4.7 5.1 5.3 5.9 5.9 ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 7

UIN 01035DD U.S. Laboratories Atlanta, Georgia - 420 Valley View, Ohio - 410 3121 Presidential Drive Atlanta, GA 30340 800.394.3669 Kansas City, Kansas - 430 935 Sunshine Road Kansas City, KS 66115 800.332.8055 Portland, Oregon - 401 4943 NW Front Avenue Portland, OR 97210 800.770.4128 Canadian Laboratories Burlington, Ontario - 450 1240 Burloak Drive, Unit 6 Burlington, ON L7L 6B3 877.732.9559 Edmonton, Alberta - 402 10717-176 Street Edmonton, AB T5S 1K1 888.489.0057 6180 Halle Dr. Suite D Valley View, OH 44125 800.726.5400 Phoenix, Arizona - 440 3319 West Earll Drive Phoenix, AZ 85017 800.445.7930 Sparks, Nevada - 400 1375 Greg Street, Suite 104 Sparks, NV 89431 800.524.7848 Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold 11777 Katy Freeway Houston Tx 77079 USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas 10450 Stancliff Road, Suite 210 Houston, TX 77099 877.835.8437 International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 8

DATE SAMPLED 15-May-15 02-Mar-15 15-Feb-15 15-Jan-15 15-Dec-14 15-Nov-14 DATE RECEIVED 22-May-15 12-Mar-15 26-Feb-15 21-Jan-15 06-Jan-15 20-Nov-14 DATE REPORTED 26-May-15 13-Mar-15 02-Mar-15 23-Jan-15 08-Jan-15 22-Nov-14 Unit No. Unit: Site Compartment: Name Capacity: Customer: PRIDE UIN 01035D6 Diesel Engine E160 LLAO1868 Pride Generator 2 Engine Caterpillar 3512C LLAO1868 DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO. 44021195851 44021151269 44021143922 44021120572 44021108951 44021083869 SIF NO. 18456295 18133528 18071339 16674378 16601130 16419356 TIME ON UNIT Hrs 26821 26539 26172 25511 24891 24452 TIME ON OIL Hrs 284 4000 3580 2919 2299 1860 OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) 6 27 19 19 14 14 Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) <1 8 7 4 3 4 Copper (Cu) 1 4 3 4 3 3 Tin (Sn) <1 <1 2 <1 <1 <1 Aluminium (Al) 1 1 3 2 <1 1 Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) 3 2 4 3 3 4 Sodium (Na) 6 10 17 7 <1 5 Potassium (K) 4 <5 9 <1 <5 5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) 835 818 736 808 889 902 Calcium (Ca) 1152 1134 1175 1161 1250 1243 Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) 1049 892 916 917 1028 1146 Zinc (Zn) 1220 1131 1100 1141 1238 1403 Molybdenum (Mo) 44 32 38 38 43 47 Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) 13.2 13.3 13.7 12.5 12.7 13.7 Fuel (%) 1 1 <1 2 1 <1 Soot (%) Infrared 0.3 0.3 0.3 0.3 0.4 0.3 Physical / Chemical Base Number (mgkoh/g) 7.4 5.5 5.3 5.9 6.4 5.9 ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 9

UIN 01035D6 U.S. Laboratories Atlanta, Georgia - 420 Valley View, Ohio - 410 3121 Presidential Drive Atlanta, GA 30340 800.394.3669 Kansas City, Kansas - 430 935 Sunshine Road Kansas City, KS 66115 800.332.8055 Portland, Oregon - 401 4943 NW Front Avenue Portland, OR 97210 800.770.4128 Canadian Laboratories Burlington, Ontario - 450 1240 Burloak Drive, Unit 6 Burlington, ON L7L 6B3 877.732.9559 Edmonton, Alberta - 402 10717-176 Street Edmonton, AB T5S 1K1 888.489.0057 6180 Halle Dr. Suite D Valley View, OH 44125 800.726.5400 Phoenix, Arizona - 440 3319 West Earll Drive Phoenix, AZ 85017 800.445.7930 Sparks, Nevada - 400 1375 Greg Street, Suite 104 Sparks, NV 89431 800.524.7848 Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold 11777 Katy Freeway Houston Tx 77079 USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas 10450 Stancliff Road, Suite 210 Houston, TX 77099 877.835.8437 International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 10

DATE SAMPLED 15-May-15 02-Mar-15 15-Feb-15 15-Jan-15 15-Dec-14 15-Nov-14 DATE RECEIVED 22-May-15 12-Mar-15 26-Feb-15 21-Jan-15 06-Jan-15 20-Nov-14 DATE REPORTED 26-May-15 13-Mar-15 02-Mar-15 23-Jan-15 08-Jan-15 22-Nov-14 Unit No. Unit: Site Compartment: Name Capacity: Customer: PRIDE UIN 0103572 Diesel Engine E161 LLAO1875 Pride Generator 3 Engine Caterpillar 3512C LLAO1875 DIAGNOSIS All wear rates normal. Abrasive and other contaminant levels are acceptable. Viscosity within specified operating range. Action: Resample next service interval to further monitor. LAB NO. 44021195852 44021151270 44021143921 44021120570 44021108952 44021083871 SIF NO. 18456296 18133529 18071338 16674375 16601183 16419358 TIME ON UNIT Hrs 25655 25475 25223 24660 24016 23419 TIME ON OIL Hrs 93 3875 3617 3068 2448 1851 OIL BRAND Mobil Mobil Mobil Mobil Mobil Mobil OIL TYPE Fleet Fleet Fleet Fleet Fleet Fleet OIL GRADE SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 SAE 15W40 OIL ADDED FILTER Hrs OIL CHANGED WO NUMBER Metals (ppm) Iron (Fe) 4 19 17 14 13 13 Chromium (Cr) <1 <1 <1 <1 <1 <1 Lead (Pb) <1 3 3 1 2 3 Copper (Cu) 1 7 6 5 7 8 Tin (Sn) <1 <1 <1 <1 <1 <1 Aluminium (Al) <1 <1 2 1 1 1 Nickel (Ni) <1 <1 <1 <1 <1 <1 Silver (Ag) <1 <1 <1 <1 <1 <1 Titanium (Ti) <1 <1 <1 <1 <1 <1 Vanadium (V) <1 <1 <1 <1 <1 <1 Contaminants (ppm) Silicon (Si) 2 2 3 3 3 4 Sodium (Na) 4 4 7 8 <1 6 Potassium (K) 2 8 7 <5 7 <5 Coolant No No No No No No Additives (ppm) Magnesium (Mg) 656 814 748 835 886 871 Calcium (Ca) 861 1149 1163 1222 1242 1244 Barium (Ba) <1 <1 <1 <1 <1 <1 Phosphorus (P) 801 918 930 1015 1027 1122 Zinc (Zn) 962 1135 1113 1186 1234 1342 Molybdenum (Mo) 34 33 39 39 42 45 Boron (B) <5 <5 <5 <5 <5 <5 Contaminants Water (%) <0.05 <0.05 <0.05 <0.05 <0.05 <0.05 Physical Tests Viscosity (cst 100C) 13.3 13.7 13.1 13.1 13.0 13.2 Fuel (%) 1 <1 1 1 1 1 Soot (%) Infrared 0.3 0.3 0.3 0.2 0.4 0.3 Physical / Chemical Base Number (mgkoh/g) 8.1 5.8 5.1 6.5 6.4 6.1 ANALYST: Sam Smith Phoenix LEGEND Normal Severe Abnormal Caution Normal 11

UIN 0103572 U.S. Laboratories Atlanta, Georgia - 420 Valley View, Ohio - 410 3121 Presidential Drive Atlanta, GA 30340 800.394.3669 Kansas City, Kansas - 430 935 Sunshine Road Kansas City, KS 66115 800.332.8055 Portland, Oregon - 401 4943 NW Front Avenue Portland, OR 97210 800.770.4128 Canadian Laboratories Burlington, Ontario - 450 1240 Burloak Drive, Unit 6 Burlington, ON L7L 6B3 877.732.9559 Edmonton, Alberta - 402 10717-176 Street Edmonton, AB T5S 1K1 888.489.0057 6180 Halle Dr. Suite D Valley View, OH 44125 800.726.5400 Phoenix, Arizona - 440 3319 West Earll Drive Phoenix, AZ 85017 800.445.7930 Sparks, Nevada - 400 1375 Greg Street, Suite 104 Sparks, NV 89431 800.524.7848 Since services are based on samples and information supplied by others, and since corrective actions, if any, are necessarily taken by others, these services are rendered without any warranty or liability of any kind beyond the actual amount paid to ALS Tribology for the services. Reported recommendations are based on interpretations of the generated test results and historical data. Certain test results appearing in this report may have been tested at other ALS laboratories within the Tribology divisional network. Scandrill Inc Attn: Paul Mosvold 11777 Katy Freeway Houston Tx 77079 USA Filter Image 0002 v1.7 Filter patch test is not performed Contact laboratory for more information Acid Number: Base Number: Base Number (Perchloric): Fuel Dilution by GC: Fuel Dilution Visc/Setaflash Fuel Soot ATR/IR: Glycol: Metals by Rotrode AES: Metals by ICP AES: Ox, NOx, SOx, FTIR: TEST METHODS: ASTM D974/D664 ASTM D4739 ASTM D2896 ASTM D3524 ASTM D445/D7279/D3828 ASTM D7686 ASTM D2982 ASTM D6595 ASTM D5185 ASTM D7418/D7414/D7415 D7624 Particle Count: ASTM D7647 /ISO 11500, 4406 Viscosity: Water KF: Water Crackle: Sales & Marketing Houston, Texas 10450 Stancliff Road, Suite 210 Houston, TX 77099 877.835.8437 International Locations Australia Brisbane, Perth, Sydney, Muswellbrook New Zealand Wellington Southeast Asia Kuala Lumpur, Singapore ASTM D445 / D7279 ASTM E203 Mod / D6304C In House South America Santiago de Chile Europe Prague 12

SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Iron = 25.16 Iron = 16.39 Difference = -34.86% 13

SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Lead = 3.07 Copper = 5.55 Tin = 1.95 Lead = 5.0 Copper = 4.11 Tin = 1.47 Difference = +38.6% Difference = -13.34% Difference = -24.62% 14

SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Silicon = 2.5 Sodium = 13.45 Silicon = 3.16 Sodium = 9.78 Difference = +26.40% Difference = -27.29% 15

SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Soot = 0.45 Fuel = 1.89 Soot = 0.32 Fuel = 1.0 Difference = -23.64% Difference = -47.09% 16

SCAN DISCOVERER WITHOUT OCTCET35 SCAN PRIDE WITH OCTCET35 Viscosity = 13.15 Viscosity = 13.15 Difference = 0.0% 17