JJ Head form B JJ Head form J JJ Cable socket, angle type KOMBITEMP TEMPERATURE SENSOR WITH LOCAL DISPLAY Including products with: DS_KombiTemp 5/
Dual temperature control with only one measuring point! Ideal for every application The combination of electrical sensor with a local display has many advantages: Temperature monitoring from two completely independent measuring systems. Significantly increased accuracy, because the joint measuring point makes it possible to compare the electrical temperature sensor directly with the on site display and vice versa. The installation costs for the temperature measuring instruments decrease because only one measuring point needs to be installed for the electrical temperature sensor and the local temperature measurement. The use of SIKA KombiTemp increases the operational safety of the monitored plants because faulty electrical temperature sensors or industrial thermometers are immediately detected. Glass inserts and electrical temperature sensors conform with DIN standards, and can be replaced, except for the models K, K, K 5, K 5, and K 5. Upon request both temperature units, C and F, can be printed on the housing label (double scale display).
Description The SIKA KombiTemp consists of:. A SIKA-industrial glass thermometer with the following properties: Shock proof Very good readability Very good long-term stability of the capillary accuracy The capillaries of the thermometer are produced and calibrated in accordance with DIN 695 The housing surface is protected against external influences by a thick anodised coating. At customer s request, an electrical temperature sensor in the same housing and immersion tube as the industrial thermometer: Temperature sensors in accordance with DIN or customised Any electrical connection options available -5-5
Head form B K and K for measuring ranges between -6 to C lenght 5 mm / width 6 mm, silver-coloured anodised Type K Special glass prismatic, approx. 6 mm diameter Red (-6... C) Blue (-... C) Diameter x mm Brass, up to PN 6 bar Stainless steel, up to PN bar Technical data Type K Type K Design Straight, clamp connection Straight, fixed thread connection Measuring range -6 C - 5 C 6 C C C 6 C C length 5 mm or 6 mm 6 mm, mm or 6 mm Electrical connection Head form B (DIN 9) Mechanical connection G½ A G½ A, G¾ A or M x.5 Electrical temperature sensor Option head transmitter x NiCr-Ni (type K) or x Fe-CuNi (type J), x NiCr-Ni (type K) or x Fe-CuNi (type J) x Pt / -wire, x Pt / -wire, x Pt / -wire, ma or... V for Pt
K 5 and K 5 for measuring ranges between -6 to C lenght 5 mm / width 6 mm, silver-coloured anodised Type K 5 Special glass, approx. 5.5 mm diameter Red (-6... C) Blue (-... C) Diameter x mm Brass, up to PN 6 bar Stainless steel, up to PN bar Technical data Type K 5 Type K 5 Design 9 clamp connection 9 fixed thread connection Measuring range -6 C - 5 C 6 C C C 6 C C length 5 mm or 6 mm 6 mm, mm or 6 mm Electrical connection Head form B (DIN 9) Mechanical connection G½ A G½ A or M x.5 Electrical temperature sensor Option head transmitter x Pt / -wire / class B x Pt / -wire / class B ma or... V for Pt
K 6 and K 6 for measuring ranges between -6 to C lenght 5 mm / width 6 mm, silver-coloured anodised Type K 6 Special glass, approx. 5.5 mm diameter Red (-6... C) Blue (-... C) Diameter x mm Brass, up to PN 6 bar Stainless steel, up to PN bar Technical data Type K 6 Type K 6 Design 9 clamp connection 9 fixed thread connection Measuring range -6 C - 5 C 6 C C C 6 C C length 5 mm or 6 mm 6 mm, mm or 6 mm Electrical connection Head form B (DIN 9) Mechanical connection G½ A G½ A or M x.5 Electrical temperature sensor Option head transmitter x NiCr-Ni (Type K) or x Fe-CuNi (Type J), x NiCr-Ni (Type K) or x Fe-CuNi (Type J) x Pt / -wire, x Pt / -wire, x Pt / -wire or x Pt / -wire (class B) ma or... V for Pt 8
Head form J K and K for measuring ranges between - to C length mm / width mm, silver-coloured anodised Type K Special glass prismatic, approx. 6 mm diameter Blue Diameter x mm Brass, up to PN 6 bar Stainless steel, up to PN bar Technical data Type K Type K Design Traight, clamp connection Straight, fixed thread connection Measuring range - 5 C 6 C C C 6 C C length 5 mm or 6 mm 6 mm, mm or 6 mm Electrical connection Head form J, top Mechanical connection G½ A G½ A or M x.5 Electrical temperature sensor Option head transmitter x Pt / -wire / class B x Pt / -wire / class B ma for Pt 9
Cable socket, angle type K for measuring ranges between - to C length mm / width mm, gold-coloured anodised Special glass prismatic, approx. 6 mm diameter Blue Diameter x mm Brass, up to PN 6 bar Stainless steel, up to PN bar Type K Technical data Type K Design Straight, fixed thread connection Measuring range - 5 C 6 C C C 6 C C length 6 mm, mm or 6 mm Electrical connection Cable socket, angle type DIN EN 5-8 Mechanical connection G½ A or M x.5 Electrical temperature sensor x Pt / -wire / class B x Pt / -wire / class B
K for measuring ranges between - to C length 5 mm / width 6 mm, gold-coloured anodised Special glass prismatic, approx. 6 mm diameter Blue Diameter x mm Brass, up to PN 6 bar Stainless steel, up to PN bar Type K Technical data Type K Design Straight, fixed thread connection Measuring range - 5 C 6 C C C 6 C C length 6 mm, mm or 6 mm Electrcal connection Cable socket, angle type DIN EN 5-8 Mechanical connection G½ A or M x.5 Electrical temperature sensor x Pt / -wire / class B x Pt / -wire / class B
K 5 for measuring ranges between - to C length 5 mm / width 6 mm, gold-coloured anodised Special glass prismatic, approx. 6 mm diameter Blue Diameter x mm Brass, up to PN 6 bar Stainless steel, up to PN bar Type K 5 Technical data Type K 5 Design 9 fixed thread connection Measuring range - 5 C 6 C C C 6 C C length 6 mm, mm or 6 mm Electrical connection Cable socket, angle type DIN EN 5-8 Mechanical connection G½ A or M x.5 Electrical temperature sensor x Pt / -wire / class B x Pt / -wire / class B
K for measuring ranges between - to C length mm / width mm, gold-coloured anodised Special glass prismatic, approx. 6 mm diameter Blue Diameter x mm Brass, up to PN 6 bar Stainless steel, up to PN bar Type K Technical data Type K Design Measuring range - 5 C 6 C C C 6 C C length 9 fixed thread connection 6 mm, mm or 6 mm Electrical connection Cable socket, angle type DIN EN 5-8 Mechanical connection G½ A or M x.5 Electrical temperature sensor x Pt / -wire / class B x Pt / -wire / class B
Order code Choose your KombiTemp Head form B Type K K K 5 K 5 K 6 Measuring range -6 C - 5 C 6 C C C 6 C C length 6 mm mm 5 mm 6 mm Mechanical connection G½ A G¾ A M x.5 Brass Stainless steel Electrical temperature sensor x Pt / -wire x Pt / -wire x Pt / -wire x Pt / -wire x NiCr-Ni (Type K) x NiCr-Ni (Type K) x Fe-CuNi (Type J) x Fe-CuNi (Type J) Head transmitter Without transmitter With... ma With... V Scale only C C and F 6 5 6 5 6 6 5 6 6 5 6 5 6 Example: KombiTemp K with measuring range between...6 C, immersion tube length 5 mm, G½ A connection, made of brass with electrical temperature sensor Pt / -wire, without head transmitter and scaled in C is due to order number: K5 ATTENTION - you have to choose an option on every property to get the -character order number 6 5 6 5 6 6 5 6 6 6 5 6 5 6 8 5 6
Head form J Cable socket, angle type K 6 K K K K K 5 K 6 5 6 5 6 5 6 5 6 5 6 5 6 5 6 6 5 6 6 6 6 6 6 8 5 6 5