AMG-GR Hardware Manual. Revision:

Similar documents
AMG-LP Hardware Manual. Revision:

ADRS Hardware Manual. Revision:

Motor Filter Module Hardware Manual P/N: EDU218 Revision:

ECO115SL Hardware Manual. Revision:

BM/BMS Brushless Motor Hardware Manual Revision:

PRO165LM Hardware Manual. Revision:

AGR Series Gear-Driven Rotary Stages

AGR Series. Mechanical-Bearing, Worm-Driven Rotary Stage. Enhanced speed and load capacity

BMS Series. DC Brushless Torque Motors. Slotless, brushless stator design provides zerocogging torque for unsurpassed velocity control

BMS Series. DC Brushless Torque Motors. Slotless, brushless stator design provides zerocogging torque for unsurpassed velocity control

ALAR Series Direct Drive, Large-Aperture, Rotary Stage

ATX165SL/SLE Series Mechanical-Bearing, Screw-Driven Linear Stage

ADRS Series Mechanical-Bearing Rotary Stage

ADRS Series Mechanical-Bearing Rotary Stage

SM Series. High-Performance Stepper Motors. Industry-standard NEMA frame stepper motors. Available encoder feedback and brake options

ECO165SL Series. Mechanical Bearing, Ball Screw Stage. High-performance in a cost-effective, economic package. Rugged mechanical design

ECO115SL Series. Mechanical Bearing, Ball-Screw Stage. High-performance in a cost-effective, economic package. Rugged mechanical design

PRO165SL/SLE Series. Mechanical Bearing, Ball-Screw Stage. Improved second-generation design. High-performance in a cost-effective package

BMS Series. DC Brushless Torque Motors. Slotless, brushless stator design provides zerocogging torque for unsurpassed velocity control

PRO225SL/SLE Series. Mechanical Bearing, Ball-Screw Stage. Improved second-generation design. High-performance in a cost-effective package

APR Series High-Precision Mechanical Bearing Rotary Stage

PRO280LM Series. Mechanical Bearing, Linear Motor Stage. Improved second-generation design. Rugged mechanical construction

PRO165LM Series. Mechanical Bearing, Linear Motor Stage. Improved second-generation design. Rugged mechanical construction

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

PRO225LM Series. Mechanical Bearing, Linear Motor Stage. Improved second-generation design. Rugged mechanical construction

Installation Instructions. Y-Series Brushless Servo Motor

Gurley INSTALLATION MANUAL. Precision Instruments. Model 835H Precision Encoder w/ Bellows Coupling. Second Edition May 1999

SLM and SLG SERIES BRUSHLESS SERVO MOTOR INSTALLATION AND SERVICE MANUAL

AXR Series Two-Axis Rotary Assembly

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

ATS150 Series. Mechanical Bearing, Ball-Screw Stage. Long life linear motion guide bearing system. Ultra-fine resolution. Integral bellows waycovers

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

ECO225LM Series. Mechanical Bearing, Linear-Motor Stage. High-performance in a cost-effective, economic package. Rugged mechanical design

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Defender 3000 Series Base Instruction Manual

MP-Series Integrated Gear Motors

ENC 150 REFERENCE MANUAL ACU-RITE

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

PRO115LM Series. Mechanical Bearing, Linear Motor Stage. Aerotech s smallest sealed linear motor stage. Rugged mechanical construction

ER SERIES EXPLOSION-PROOF BRUSHLESS SERVO MOTOR INSTALLATION AND SERVICE MANUAL

INTRODUCTION WARNING SIGNS AND THEIR MEANINGS

PRO225-HS (High Speed) Series

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

DRV-1. Step Motor Drive. User Manual Mentor Avenue Cincinnati, Ohio Tel (513)

ADRT Series Rotary Stages

RHINO MOTION CONTROLS

Indoor Air Quality Meter

AXR Series. Two-Axis Rotary Assembly. Multiple configurations support a range of load and accuracy requirements

Below, you can see the warning symbols used throughout the manual and their meaning.

ABL1000 Series. Air-Bearing, Direct-Drive Linear Stage. Designed for high-performance alignment and assembly. 0.5 nm closed-loop resolution

Mini-MAG Positioning Products

HIGH VOLTAGE PROVING UNIT

StarEye. 350 ma version. No control electronics on board

IAQ-CALC TM Indoor Air Quality Meter

CONTENT 1 PICTURE GENERAL... 3

IAQ-CALC TM Indoor Air Quality Meter

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

1291BL Series Technical Specification Single Axis Position and Rate Table System

High Frequency SineWave Guardian TM

VELOCICALC Air Velocity Meter

Ventilation Testing. Micromanometer. Alnor Model AXD610 AIRFLOW TM Model PVM610. Operation and Service Manual

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

ARMS Series Rotary Motion Simulators

Rental Industry Safety Tester Safe Check 5s

Guardian Steel Gear Shaft Coupling

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

SecoVac * Ground & Test Device

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

PIglide RM Rotation Stage with Air Bearings

LN3 Series Motor and Drives

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

ATS1000 Series. Mechanical Bearing, Ball-Screw Stage. Precision-ground ball screw. Long-life linear motion guide bearing system

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

! Warning, refer to accompanying documents.

GETTING STARTED GUIDE NI DI, ±5 V to 24 V, Differential/Single-Ended, 500 ns

Ultra Series: Crossed Roller Ultra Precision Stages

TITAN FLOW CONTROL, INC.

APR Series. Direct-Drive Rotary Stage. Accuracies to 1.5 arc second. Axial load capacity up to 250 kg. Incremental or absolute encoders

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Gearmotors & Gearheads. Servo Motors & Drives. Linear & Rotary Positioning Stages. Direct Drive Rotary Table Product Manual

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

ATS100 Series. Mechanical Bearing, Ball-Screw Stage. Long life linear motion guide bearing system. Ultra-fine resolution. Integral bellows waycovers

DP-CALC TM Micromanometer

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

Electric Actuator Installation, Operation & Maintenance Manual

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

1000mA - 650mA Phase Dimmable LED Driver

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

i400s Calibration Information Introduction

650mA Phase Dimmable LED Driver

Model 1672, 1673 Triple Output Power Supply

Features & Benefits. Options & Accessories

Guardian Taper Grid Shaft Coupling

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

BLMUC Series Linear Motors

Screw Driven automation tables

MV Series Motors Operation & Parts Manual

L VC and L SC Cantilevered Load Capability (ATS115)

ALS20000 Series. Mechanical Bearing, Linear Motor Stage. Protective metal waycover. Integral cable management system

Transcription:

AMG-GR Hardware Manual Revision: 1.01.00

Global Technical Support Go to www.aerotech.com/global-technical-support for information and support about your Aerotech products. The website provides downloadable resources (such as up-to-date software, product manuals, and Help files), training schedules, and PC-to-PC remote technical support. You can also complete Product Return (RMA) forms and get information about repairs and spare or replacement parts. For immediate help, contact a service office or your sales representative. Have your customer order number available before you call or include it in your email. Phone: +1-412-967-6440 Fax: +1-412-967-6870 Email: service@aerotech.com United Kingdom Phone: +44 (0)1256 855055 Fax: +44 (0)1256 855649 Email: service@aerotech.co.uk Germany Phone: +49 (0)911 967 9370 Fax: +49 (0)911 967 93720 Email: service@aerotechgmbh.de France Phone: +33 2 37 21 87 65 Email: service@aerotech.co.uk United States (World Headquarters) 101 Zeta Drive Pittsburgh, PA 15238-2811 www.aerotech.com Japan Phone: +81 (0)50 5830 6814 Fax: +81 (0)43 306 3773 Email: service@aerotechkk.co.jp China Phone: +86 (21) 3319 7715 Email: service@aerotech.com Taiwan Phone: +886 (0)2 8751 6690 Email: service@aerotech.tw This manual contains proprietary information and may not be reproduced, disclosed, or used in whole or in part without the express written permission of Aerotech, Inc. Product names mentioned herein are used for identification purposes only and may be trademarks of their respective companies. Copyright 2017, Aerotech, Inc., All rights reserved.

AMG-GR Hardware Manual Table of Contents Table of Contents AMG-GR Hardware Manual 1 Table of Contents 3 List of Figures 4 List of Tables 5 Safety Procedures and Warnings 6 EU Declaration of Incorporation 7 Chapter 1: Overview 9 1.1. Environmental Specifications 11 1.2. Accuracy and Temperature Effects 11 1.3. Basic Specifications 12 1.4. Vacuum Operation 13 Chapter 2: Mechanical Specifications and Installation 15 2.1. Unpacking and Handling the Stage 15 2.2. Dimensions 17 2.3. Securing the Stage to the Mounting Surface 21 2.4. Attaching the Payload to the Stage 23 Chapter 3: Electrical Specifications and Installation 25 3.1. Motor and Feedback Connectors 26 3.2. Motor and Feedback Wiring 31 3.3. Motor and Feedback Specifications 32 3.4. Limits, Marker, and Machine Direction 37 3.5. Motor and Feedback Phasing 38 Chapter 4: Maintenance 41 4.1. Service and Inspection Schedule 41 4.2. Cleaning and Lubrication 41 4.3. Troubleshooting 43 Appendix A: Warranty and Field Service 45 Appendix B: Revision History 47 Index 49 www.aerotech.com 3

Table of Contents AMG-GR Hardware Manual List of Figures Figure 2-1: Shipping and Lifting Brackets 16 Figure 2-2: AMG100GR Dimensions 17 Figure 2-3: AMG150GR Dimensions 18 Figure 2-4: AMG200GR Dimensions 19 Figure 2-5: AMG300GR Dimensions 20 Figure 2-6: View of an AMG-GR Stage Showing Mounting Holes 22 Figure 3-1: Motor and Feedback Wiring 31 Figure 3-2: Machine Direction 37 Figure 3-3: Hall Phasing 38 Figure 3-4: Analog Encoder Phasing Reference Diagram 39 Figure 3-5: Encoder Phasing Reference Diagram (Standard) 39 Figure 4-1: AMG-GR Lubrication Ports 42 Figure 4-2: View of the Current Draw of a Typical AMG-GR Stage Before and After Lubrication 42 4 www.aerotech.com

AMG-GR Hardware Manual Table of Contents List of Tables Table 1-1: Model Options 9 Table 1-2: Environmental Specifications 11 Table 1-3: AMG-GR Series Specifications 12 Table 2-1: Stage to Mounting Surface Hardware 21 Table 3-1: 4-Pin Motor Connector Pin Assignments [AZ and EL] with a BM or BMS Motor 27 Table 3-2: 4-Pin Motor Connector Pin Assignments [AZ and EL] with a Stepper Motor 27 Table 3-3: 25-Pin Feedback Connector Pin Assignments with a BM or BMS motor [AZ and EL] 28 Table 3-4: 25-Pin SM35-CN1 (NEMA17) Stepper Motor Feedback Connector Pinout (AMG100GR, AMG150GR, and AMG200GR [EL]) 29 Table 3-5: 9-Pin Limit Connector (-TR90, -TR315, or -TR180 Options) 30 Table 3-6: 15-Pin Direct Encoder Connector (-E1, -E2, or -E3 Encoder Option) 30 Table 3-7: Feedback Specifications 32 Table 3-8: Resolution Information 33 Table 3-9: AMG-GR Brushless Rotary Motor Specifications 34 Table 3-10: AMG-GR Brushless, Slotless Rotary Motor Specifications 35 Table 3-11: AMG-GR Stepper Motor Specifications 36 www.aerotech.com 5

Table of Contents AMG-GR Hardware Manual Safety Procedures and Warnings Read this manual in its entirety before installing, operating, or servicing this product. If you do not understand the information contained herein, contact an Aerotech representative before proceeding. Strictly adhere to the statements given in this section and other handling, use, and operational information given throughout the manual to avoid injury to you and damage to the equipment. The following statements apply wherever the Warning or Danger symbol appears within this manual. Failure to observe these precautions could result in serious injury to those individuals performing the procedures and/or damage to the equipment. D A N G E R : This product contains potentially lethal voltages. To reduce the possibility of electrical shock, bodily injury, or death the following precautions must be followed. 1. Access to the AMG-GR and component parts must be restricted while connected to a power source. 2. Do not connect or disconnect any electrical components or connecting cables while connected to a power source. 3. Disconnect electrical power before servicing equipment. 4. All components must be properly grounded in accordance with local electrical safety requirements. 5. Operator safeguarding requirements must be addressed during final integration of the product. W A R N I N G : To minimize the possibility of electrical shock, bodily injury or death the following precautions must be followed. 1. Moving parts can cause crushing or shearing injuries. Access to all stage and motor parts must be restricted while connected to a power source. 2. Cables can pose a tripping hazard. Securely mount and position all system cables to avoid potential hazards. 3. Do not expose this product to environments or conditions outside of the listed specifications. Exceeding environmental or operating specifications can cause damage to the equipment. 4. The AMG-GR stage must be mounted securely. Improper mounting can result in injury and damage to the equipment. 5. Use care when moving the AMG-GR stage. Lifting or transporting the AMG-GR stage improperly can result in injury or damage to the AMG-GR. 6. This product is intended for light industrial manufacturing or laboratory use. Use of this product for unintended applications can result in injury and damage to the equipment. 7. If the product is used in a manner not specified by the manufacturer, the protection provided by the product can be impaired and result in damage, shock, injury, or death. 8. Operators must be trained before operating this equipment. 9. All service and maintenance must be performed by qualified personnel. 6 www.aerotech.com

AMG-GR Hardware Manual Table of Contents EU Declaration of Incorporation Manufacturer: Aerotech, Inc. 101 Zeta Drive Pittsburgh, PA 15238-2811 USA herewith declares that the product: AMG-GR Gimbal is intended to be incorporated into machinery to constitute machinery covered by the Directive 2006/42/EC as amended; and that the following harmonized European standards have been applied: EN ISO 12100:2010 Safety of machinery - Basic concepts, general principles for design EN 60204-1:2010 Safety of machinery - Electrical equipment of machines - Part 1: General requirements and further more declares that it is not allowed to put the equipment into service until the machinery into which it is to be incorporated or of which it is to be a component has been found and declared to be in conformity with the provisions of the Directive 2006/42/EC and with national implementing legislation, i.e., as a whole, including the equipment referred to in this Declaration. This is to certify that the aforementioned product is in accordance with the applicable requirements of the following Directive(s): 2011/65/EU RoHS 2 Directive Authorized Representative: Address: Simon Smith, European Director Aerotech Ltd The Old Brick Kiln Ramsdell, Tadley Hampshire RG26 5PR UK Name Position Location / Alex Weibel Engineer Verifying Compliance Pittsburgh, PA www.aerotech.com 7

Table of Contents AMG-GR Hardware Manual This page intentionally left blank. 8 www.aerotech.com

AMG-GR Hardware Manual Overview Chapter 1: Overview N O T E : Aerotech continually improves its product offerings; listed options may be superseded at any time. All drawings and illustrations are for reference only and were complete and accurate as of this manual s release. Refer to www.aerotech.com for the most up-to-date information. Table 1-1: Model Options AMG-GR Gear-Driven Gimbal AMG100GR 100 mm diameter clear aperture AMG150GR 150 mm diameter clear aperture AMG200GR 200 mm diameter clear aperture AMG300GR 300 mm diameter clear aperture Cell (Required) -CL0 No cell -CL1 Front surface reflecting cell -CL2 Centered cell Direct Rotary Feedback (Optional) -E1 Incremental encoders,1 Vpp, one per axis -E2 Incremental encoders, digital TTL output, x5 multiplication, one per axis -E3 Incremental encoders, digital TTL output, x50 multiplication, one per axis Azimuth [AZ] Travel (Required) -TR180 Limited travel, ±90 degrees -TRCNT Continuous travel Azimuth Motor (Required) -M0 No motor -M1 AMG100GR / 150GR BMS35 brushless servomotor with 2000-line TTL encoder AMG200GR / 300GR BMS60 brushless servomotor with 2500-line TTL encoder -M2 AMG100GR / 150GR BMS35 brushless servomotor with 2000-line TTL encoder and brake AMG200GR / 300GR BMS60 brushless servomotor with 2500-line TTL encoder and brake -M3 AMG100GR / 150GR BMS35 brushless servomotor with 2000-line TTL encoder AMG200GR / 300GR BMS60 brushless servomotor with 1000-line 1 Vpp encoder -M4 AMG100GR / 150GR BMS35 brushless servomotor with 2000-line TTL encoder and brake AMG200GR / 300GR BMS60 brushless servomotor with 1000-line 1 Vpp encoder and brake -M5 AMG100GR / 150GR BM22 brushless servomotor with 2000-line TTL encoder AMG200GR / 300GR BM75 brushless servomotor with 2500-line TTL encoder -M6 AMG100GR / 150GR BM22 brushless servomotor with 2000-line TTL encoder and brake AMG200GR / 300GR BM75 brushless servomotor with 2500-line TTL encoder and brake -M7 AMG100GR / 150GR SM35 stepper motor AMG200GR / 300GR BM75 brushless servomotor with 1000-line 1 Vpp encoder -M8 AMG200GR / 300GR BM75 brushless servomotor with 1000-line 1 Vpp encoder and brake -M9 AMG200GR / 300GR SM60 Stepper Motor www.aerotech.com Chapter 1 9

Overview AMG-GR Hardware Manual Elevation [EL] Travel (Required) -TR090 Limited travel, ± 45 degrees -TR315 Limited travel, ± 157.5 degrees -TRCNT Continuous travel Elevation Motor (Required) -M0 No motor AMG100GR / 150GR / -M1 200GR BMS35 brushless servomotor with 2000-line TTL encoder AMG300GR BMS60 brushless servomotor with 2500-line TTL encoder -M2 -M3 -M4 -M5 -M6 -M7 AMG100GR / 150G / 200GR AMG300GR AMG100GR / 150GR / 200GR AMG300GR AMG100GR / 150GR / 200GR AMG300GR AMG100GR / 150GR / 200GR AMG300GR AMG100GR / 150GR / 200GR AMG300GR AMG100GR / 150GR / 200GR AMG300GR -M8 AMG300GR BMS35 brushless servomotor with 2000-line TTL encoder and brake BMS60 brushless servomotor with 2500-line TTL encoder and brake BMS35 brushless servomotor with 2000-line TTL encoder BMS60 brushless servomotor with 1000-line 1 Vpp encoder BMS35 brushless servomotor with 2000-line TTL encoder and brake BMS60 brushless servomotor with 1000-line 1 Vpp encoder and brake BM22 brushless servomotor with 2000-line TTL encoder BM75 brushless servomotor with 2500-line TTL encoder BM22 brushless servomotor with 2000-line TTL encoder and brake BM75 brushless servomotor with 2500-line TTL encoder and brake SM35 stepper motor -M9 AMG300GR SM60 stepper motor Mounting Plate (Optional) -MP Optical table mounting plate Note: -MP option required when continuous azimuth travel option is selected. Metrology (Required) -PL0 No metrology performance plots -PL1 Metrology, uncalibrated with performance plots -PL2 Metrology, calibrated (HALAR) with performance plots BM75 brushless servomotor with 1000-line 1 Vpp encoder BM75 brushless servomotor with 1000-line 1 Vpp encoder and brake 10 Chapter 1 www.aerotech.com

AMG-GR Hardware Manual Overview 1.1. Environmental Specifications Table 1-2: Ambient Temperature Humidity Altitude Vibration Protection Rating Use W A R N I N G : Do not expose this product to environments or conditions outside of the listed specifications. Exceeding environmental or operating specifications can cause damage to the equipment. Environmental Specifications Operating:10 to 35 C (50 to 95 F) The optimal operating temperature is 20 C ±2 C (68 F ±4 F). If at any time the operating temperature deviates from 20 C degradation in performance could occur. Storage: 0 to 40 C (32 to 104 F) in original shipping packaging Operating: 20% to 60% RH Storage: 10% to 70% RH, non-condensing in original packaging. The stage should be packaged with desiccant if it is to be stored for an extended time. Operating: 0 m to 2,000 m (0 ft to 6,562 ft) above sea level Contact Aerotech if your specific application involves use above 2,000 m or below sea level. Use the system in a low vibration environment. Excessive floor or acoustical vibration can affect system performance. Contact Aerotech for information regarding your specific application. The AMG-GR gimbals have limited protection against airborne particles but not water. This equates to an ingress protection rating of IP40. Indoor use only 1.2. Accuracy and Temperature Effects Aerotech products are designed for and built in a 20 C (68 F) environment. Extreme temperature changes could cause a decrease in performance or permanent damage to the AMG-GR. At a minimum, the environmental temperature must be controlled to within 0.25ºC per 24 hours to ensure the AMG-GR specifications are repeatable over an extended period of time. The severity of temperature effects on all specifications depends on many different environmental conditions, including how the AMG-GR is mounted. Contact the factory for more details. www.aerotech.com Chapter 1 11

Overview AMG-GR Hardware Manual 1.3. Basic Specifications Basic AMG-GR series positioning stage specifications are shown in Table 1-3. Table 1-3: AMG-GR Series Specifications Basic Model AMG100GR AMG150GR AMG200GR AMG300GR Total Travel Azimuth 180 continuous rotation (1) Elevation 90, 315, and continuous rotation Clear Aperture Diameter 100 mm 150 mm 200 mm 300 mm Accuracy Bidirectional Repeatability (2) Uncalibrated Calibrated Uncalibrated with Direct Encoder Calibrated with Direct Encoder Without Direct Encoder With Direct Encoder AZ: 0.87 mrad (180 arc sec) EL: 0.87 mrad (180 arc sec) AZ: 0.29 mrad (60 arc sec) EL: 0.29 mrad (60 arc sec) AZ: 58 µrad (12 arc sec) EL: 58 µrad (12 arc sec) AZ: 39 µrad (8 arc sec) EL: 39 µrad (8 arc sec) AZ: 97 µrad (20 arc sec) EL: 97 µrad (20 arc sec) AZ: 0.22 mrad (45 arc sec) EL: 0.22 mrad (45 arc sec) AZ: 0.58 mrad (120 arc sec) EL: 0.58 mrad (120 arc sec) AZ: 0.24 mrad (50 arc sec) EL: 0.24 mrad (50 arc sec) AZ: 49 µrad (10 arc sec) EL: 49 µrad (10 arc sec) AZ: 29 µrad (6 arc sec) EL: 39 µrad (8 arc sec) AZ: 29 µrad (6 arc sec) EL: 29 µrad (6 arc sec) Tilt Error Motion 49 µrad (10 arc sec) Orthogonality 73 µrad (15 arc sec) Gear Ratio Azimuth 51:1 51:1 85:1 117:1 Elevation 51:1 51:1 67:1 85:1 Servomotor 180 /s Maximum Speed (3) Stepper 40 /s (Azimuth) 60 /s 40 /s Motor 60 /s (Elevation) Azimuth Aperture (available only with 180 azimuth travel 50 mm 50 mm 100 mm 150 mm option) Max. Load Capacity 12 kg 15 kg 25 kg 45 kg Maximum Torque Load to Azimuth/ Elevation Shaft for Offset Loading 2.5 N m 2.5 N m 3.5 N m 12 N m Standard 9.7 kg 11.9 kg 18.7 kg 32.2 kg Mass (BMS Direct Servomotor) 11.1 kg 13.3 kg 20.8 kg 35.1 kg Encoder Material Aluminum 1. Custom travels available upon request. 2. Certified with each stage. Specifications are per axis unless specified. 3. Maximum speed is load dependent. Contact and Aerotech Application Engineer if imbalanced loads are present. Requires the selection of an appropriate amplifier with sufficient voltage and current. 12 Chapter 1 www.aerotech.com

AMG-GR Hardware Manual Overview 1.4. Vacuum Operation Contact the factory for information regarding operation in a vacuum environment. Preparation and considerations for operation in a vacuum environment: Lubrication with vacuum-compatible lubricants Use of materials, fasteners, and coatings with vacuum outgas performance compatible with the level of vacuum specified For high vacuum stages, elimination of situations that may allow gases to become temporarily trapped during pump down Extensive cleaning prior to assembly in a clean environment and packaging in a special polyethylene bag Use of components able to withstand elevated temperatures (non-operating) for bake-out performances Reduced air pressure eliminates significant convective heat transfer. This, coupled with the viscous vacuum-compatible lubricants, could result in excessive motor operating temperatures. Because of this, consider all continuous torque ratings to be 40 to 60% lower than the value specified for operation in normal atmospheric environment. Reduce motor usage accordingly. www.aerotech.com Chapter 1 13

Overview AMG-GR Hardware Manual This page intentionally left blank. 14 Chapter 1 www.aerotech.com

AMG-GR Hardware Manual Mechanical Specifications and Installation Chapter 2: Mechanical Specifications and Installation W A R N I N G : AMG-GR installation must be in accordance to instructions provided by this manual and any accompanying documentation. Failure to follow these instructions could result in injury or damage to the equipment. 2.1. Unpacking and Handling the Stage D A N G E R / H E A V Y : Manually lifting and moving the stage requires a minimum of two people on either side of the stage. Refer to Section 1.3. for stage mass specifications. Do not attempt to lift heavy loads single handed. Follow the lifting instructions and only manually lift from the specified surfaces (if lifting hardware hasn't been supplied). Do not use any of the cables as lifting points. W A R N I N G : It is the customer's responsibility to safely and carefully lift the stage. Make sure that all moving parts are secure before moving the AMG-GR. Unsecured moving parts may shift and cause bodily injury. Improper handling could adversely affect the performance of the AMG-GR. Use care when moving the AMG-GR. Lift the stage only by the yoke or with appropriate hoist rings/eyebolts. Do not use the cell to lift or support the stage. N O T E : If any damage has occurred during shipping, report it immediately. Lifting Instructions Lift the AMG100GR and AMG150GR stages by the yoke. When moving the stage, do not lift or support the stage by the optics cell. Lift the AMG200GR and AMG300GR stages with appropriate hoist rings or eyebolts attached to the elevation shipping brackets. M8x1.25 x 12mm deep holes are provided in the shipping brackets for this purpose (refer to Figure 2-1). Carefully remove the AMG-GR from its protective shipping container. Gently set the AMG-GR on a smooth, flat, and clean surface. Before operating the AMG-GR, it is important to let it stabilize at room temperature for at least 12 hours. Allowing it to stabilize to room temperature will ensure that all of the alignments, preloads, and tolerances are the same as they were when tested at Aerotech. Use compressed nitrogen or clean, dry, oil-less air to remove any dust or debris that has collected during shipping. Each AMG-GR has a label listing the system part number and serial number. These numbers contain information necessary for maintaining or updating system hardware and software. Locate this label and record the information for later reference. www.aerotech.com Chapter 2 15

Mechanical Specifications and Installation AMG-GR Hardware Manual Shipping Clamps Before the stage can be operated, remove all of the red anodized shipping brackets. Save the shipping brackets to be used for long-term storage of the stage or return shipping for service. Figure 2-1: Shipping and Lifting Brackets 16 Chapter 2 www.aerotech.com

AMG-GR Hardware Manual Mechanical Specifications and Installation 2.2. Dimensions N O T E : Aerotech continually improves its product offerings; listed options may be superseded at any time. All drawings and illustrations are for reference only and were complete and accurate as of this manual s release. Refer to www.aerotech.com for the most up-to-date information. Figure 2-2: AMG100GR Dimensions www.aerotech.com Chapter 2 17

Mechanical Specifications and Installation AMG-GR Hardware Manual Figure 2-3: AMG150GR Dimensions 18 Chapter 2 www.aerotech.com

AMG-GR Hardware Manual Mechanical Specifications and Installation Figure 2-4: AMG200GR Dimensions www.aerotech.com Chapter 2 19

Mechanical Specifications and Installation AMG-GR Hardware Manual Figure 2-5: AMG300GR Dimensions 20 Chapter 2 www.aerotech.com

AMG-GR Hardware Manual Mechanical Specifications and Installation 2.3. Securing the Stage to the Mounting Surface W A R N I N G : The AMG-GR must be mounted securely. Improper mounting can result in injury and damage to the equipment. W A R N I N G : Make sure that all moving parts are secure before moving the AMG-GR. Unsecured moving parts may shift and cause bodily injury. The mounting surface must be flat and have adequate stiffness in order to achieve the maximum performance from the AMG-GR stage. When it is mounted to a non-flat surface, the stage can be distorted as the mounting screws are tightened. This distortion will decrease overall accuracy. Adjustments to the mounting surface must be done before the stage is secured. Inspect the mounting surface for dirt or unwanted residue and clean if necessary. Use precision flatstones on the mounting surface to remove any burrs or high spots. Clean the mounting surface with a lint free cloth and acetone or isopropyl alcohol and allow the cleaning solvent to completely dry. Gently place the stage on the mounting surface. N OT E : To maintain accuracy, the mounting surface must be flat to within 10 µm over the entire stage footprint. N O T E : The AMG-GR is precision machined and verified for flatness prior to product assembly at the factory. If machining is required to achieve the desired flatness, it should be performed on the mounting surface rather than the AMG-GR. Shimming should be avoided if possible. If shimming is required, it should be minimized to retain maximum rigidity of the system. AMG-GR series stages have a fixed mounting pattern (as shown in Figure 2-6). Stages without the optional mounting plate have counter-bored mounting holes that are designed for 5 mm socket head cap screws (SHCS) on the AMG100GR and AMG150GR, and for 6 mm SHCS on the AMG200GR and AMG300GR. Stages with the -MP (mounting plate) option have counter-bored mounting holes that are designed for 6 mm or 1/4" SHCS. Tightening torque values for the mounting hardware are dependent on the properties of the surface to which the stage is being mounted. Values provided in Table 2-1 are typical values and may not be accurate for your mounting surface. Refer to Section 2.2. for specific model mounting locations and dimensions. Table 2-1: Stage to Mounting Surface Hardware Mounting Hardware Typical Screw Torque AMG100GR, AMG150GR 5 mm SHCS 4 N m AMG200GR, AMG300GR 6 mm SHCS 7 N m -MP Option 6 mm or 1/4" SHCS counter-bored mounting holes 7 N m www.aerotech.com Chapter 2 21

Mechanical Specifications and Installation AMG-GR Hardware Manual Figure 2-6: View of an AMG-GR Stage Showing Mounting Holes 22 Chapter 2 www.aerotech.com

AMG-GR Hardware Manual Mechanical Specifications and Installation 2.4. Attaching the Payload to the Stage Inspect the mounting surface for dirt or unwanted residue and clean if necessary. Clean the mounting surface with a lint free cloth and acetone or isopropyl alcohol and allow the cleaning solvent to completely dry. To prevent damage to the payload or stage, test the operation of the stage before the payload is attached. Aerotech recommends that customers use a representative payload during start-up to prevent accidental damage to the stage and the payload. Proceed with the electrical installation and test the motion control system in accordance with the system documentation. Document all results for future reference. For information on electrical installation refer to Chapter 3 and the documentation delivered with the stage. N O T E : If your AMG-GR was purchased with Aerotech controls, it might have been tuned with a representative payload based on the information provided at the time of order. If the AMG-GR is started up without a payload, the servo gains provided by Aerotech with the shipment may not be appropriate and servo instability can occur. Refer to the controller help file for tuning assistance. The payload must be flat, rigid, and comparable to the stage in quality to maintain optimum performance. The standard AMG-GR series is capable off accommodating cells up to 300 mm in diameter. Custom solutions can be designed for non-standard loads. www.aerotech.com Chapter 2 23

Mechanical Specifications and Installation AMG-GR Hardware Manual This page intentionally left blank. 24 Chapter 2 www.aerotech.com

AMG-GR Hardware Manual Electrical Specifications and Installation Chapter 3: Electrical Specifications and Installation W A R N I N G : Electrical installation must be performed by properly qualified personnel. Electrical installation requirements will vary depending on product options. Installation instructions in this section are for AMG-GRs equipped with standard Aerotech motors intended for use with an Aerotech motion control system. Contact Aerotech for further information regarding products that are otherwise configured. Aerotech motion control systems are adjusted at the factory for optimum performance. When the AMG-GR is part of a complete Aerotech motion control system, setup usually involves connecting the AMG-GR to the appropriate drive chassis with the cables provided. Labels on the system components usually indicate the appropriate connections. If system level integration was purchased, an electrical drawing showing system interconnects has been supplied with the system (separate from this documentation). The electrical wiring from the motor and encoder are integrated at the factory. Refer to the following sections for standard motor wiring and connector pin assignments. W A R N I N G : Operator access to the base and tabletop must be restricted while connected to a power source. Failure to do so may cause electric shock. D A N G E R : Remove power before connecting or disconnecting electrical components or cables. Failure to do so may cause electric shock. W A R N I N G : Applications requiring access to the stage while it is energized will require additional grounding and safeguards. The System Integrator or qualified installer is responsible for determining and meeting all safety and compliance requirements necessary for the integration of this stage into the final application. www.aerotech.com Chapter 3 25

Electrical Specifications and Installation AMG-GR Hardware Manual 3.1. Motor and Feedback Connectors Stages equipped with standard motors and encoders come from the factory completely wired and assembled. N O T E : Refer to the other documentation accompanying your Aerotech equipment. Call your Aerotech representative if there are any questions on system configuration. The protective ground connection of the AMG-GR provides motor frame ground protection only. Additional grounding and safety safeguards are required for applications requiring access to the stage while it is energized. The System Integrator or qualified installer is responsible for determining and meeting all safety and compliance requirements necessary for the integration of this stage into the final application. D A N G E R : Remove power before connecting or disconnecting electrical components or cables. Failure to do so may cause electric shock. W A R N I N G : The protective ground connection must be properly installed to minimize the possibility of electric shock. W A R N I N G : Operator access to the base and tabletop must be restricted while connected to a power source. Failure to do so may cause electric shock. C A U T I O N : The stage controller must provide over-current and over-speed protection. Failure to do so may result in permanent damage to the motor and stage components. 26 Chapter 3 www.aerotech.com

AMG-GR Hardware Manual Electrical Specifications and Installation Table 3-1: 4-Pin Motor Connector Pin Assignments [AZ and EL] with a BM or BMS Motor Pin Description Connector A1 Motor Phase A A2 A3 Motor Phase B Motor Phase C 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 Reserved A4 Frame ground (motor protective ground) Mating Connector Aerotech P/N Third Party P/N Backshell ECK00656 Amphenol #17E-1726-2 Sockets [QTY. 4] ECK00659 ITT Cannon #DM53744-6 Connector ECK00657 ITT Cannon #DBMM9W4SA197 Table 3-2: 4-Pin Motor Connector Pin Assignments [AZ and EL] with a Stepper Motor Pin Description Connector A1 A2 A3 Motor Phase A Motor Phase B Phase A- (Return) 1 Brake - (1) 2 Brake + (1) 3 Reserved 4 Frame ground (motor protective ground) 5 Frame ground (motor protective ground) A4 Phase B- (Return) 1. With Brake option only Mating Connector Aerotech P/N Third Party P/N Backshell ECK00656 Amphenol #17E-1726-2 Sockets [QTY. 4] ECK00659 ITT Cannon #DM53744-6 Connector ECK00657 ITT Cannon #DBMM9W4SA197 www.aerotech.com Chapter 3 27

Electrical Specifications and Installation AMG-GR Hardware Manual Table 3-3: 25-Pin Feedback Connector Pin Assignments with a BM or BMS motor [AZ and EL] Pin Description Connector 1 Signal shield connection 2 Over-Temperature Thermistor sensor (1) 3 +5 V power supply 4 Reserved 5 Hall Effect sensor, phase B 6 Marker-N 7 Marker 8 Reserved 9 Reserved 10 Hall Effect sensor, phase A 11 Hall Effect sensor, phase C 12 Reserved 13 Brake - (2) 14 Cosine 15 Cosine-N 16 Reserved 16 +5 V power supply 17 Sine 18 Sine-N 19 Reserved 20 Common ground 21 Common ground 22 Reserved 23 Reserved 24 Reserved 25 Brake + (2) 1. BMS motors only (otherwise Reserved) 2. With Brake option only Mating Connector Aerotech P/N Third Party P/N Backshell ECK00656 Amphenol #17E-1726-2 Connector ECK00300 FCI DB25S064TLF 28 Chapter 3 www.aerotech.com

AMG-GR Hardware Manual Electrical Specifications and Installation Table 3-4: 25-Pin SM35-CN1 (NEMA17) Stepper Motor Feedback Connector Pinout (AMG100GR, AMG150GR, and AMG200GR [EL]) Pin Description Connector 1 Connector key (to prevent improper connection) 2 Reserved 3 Encoder +5 V 4 Reserved 5 Reserved 6 Marker-N 7 Marker 8 Reserved 9 Reserved 10 Reserved 11 Reserved 12 Reserved 13 Reserved 14 Cosine 15 Cosine-N 16 Limit +5 V 17 Sine 18 Sine-N 19 Reserved 20 Limit Common 21 Encoder Common 22 Reserved 23 Reserved 24 Reserved 25 Reserved Case Signal shield connection (to case) Mating Connector Aerotech P/N Third Party P/N Backshell ECK00656 Amphenol #17E-1726-2 Connector ECK00300 FCI DB25S064TLF 14 1 25 13 www.aerotech.com Chapter 3 29

Electrical Specifications and Installation AMG-GR Hardware Manual Table 3-5: 9-Pin Limit Connector (-TR90, -TR315, or -TR180 Options) Pin # Description Connector Case Signal shield connection 1 +5V supply input for optical limit switch boards 2 Common ground to limit switch 3 Signal indicating maximum travel produced by positive/cw stage direction 4 Reserved 5 Signal indicating stage maximum travel produced by negative/ccw stage direction 6 Reserved 7 Common ground 8 Stage ID 9 Reserved Mating Connector Aerotech P/N 3rd Party P/N Backshell ECK01021 Amphenol DE24657 Connector ECK00340 Cinch DE-9S Table 3-6: 15-Pin Direct Encoder Connector (-E1, -E2, or -E3 Encoder Option) Pin Description Connector 1 Sine 2 Cosine 4 +5 V supply input for optical encoders (-TR180 Option only) 9 Sine-N 10 Cosine-N 12 Common ground to encoder power (-TR180 Option only) Case Shield connection Pins not shown are reserved Mating Connector Aerotech P/N 3rd Party P/N Backshell ECK01022 Amphenol 17-1725-2 Connector ECK00326 Cinch DA-15S 30 Chapter 3 www.aerotech.com

AMG-GR Hardware Manual Electrical Specifications and Installation 3.2. Motor and Feedback Wiring All motor and controller manufacturers have their own designations for motor ØA/ØB/ØC and Hall signals A/B/C (refer to Section 3.5. for motor phasing). Shielded cables are required for the motor and feedback connections. Figure 3-1: Motor and Feedback Wiring www.aerotech.com Chapter 3 31

Electrical Specifications and Installation AMG-GR Hardware Manual 3.3. Motor and Feedback Specifications Table 3-7: Feedback Specifications Hall-Effect Sensors Specifications [BM and BMS motors options only] Supply Voltage 5 V ±5% Supply Current 50 ma Output Type Open Collector Output Voltage 24 V max (pull up) Output Current 5 ma (sinking) Thermistor Specifications [BMS motors options only] Logic "0" (no fault) Polarity Logic "1" (over-temperature fault) Cold Resistance 100 Ω Hot Resistance 10 K Note: 1K pull-up to +5V recommended. Encoder Specifications [BM and BMS motors options only] Supply Voltage 5 V ±5% Supply Current 250 ma Output Signals Sinusoidal Type (Incremental Encoder): 1 V pk-pk into 120 Ω Load (differential signals SIN+, SIN-, COS+, COS- are.5 V pk-pk relative to ground.) Digital Output (Incremental Encoder): RS422/485 compatible Limit Switch Specifications [-TR090, -TR315, and -TRCNT options only] Supply Voltage 5 V ±5% Supply Current 25 ma Output Type Open Collector Output Voltage 5 V Output Current 10 ma (sinking) Normally Closed (NC) Sinks current to ground (Logic "0") when not in limit High impedance (Logic "1") when in limit Requires external pull-up to +5 V (10 kω recommended) Output Polarity Normally Open (NO) Sinks current to ground (Logic "0") when in limit High impedance (Logic "1") when not in limit Requires external pull-up to +5 V (10 kω recommended) Notes: 1. If the AMG-GR is driven beyond the electrical limit, it will encounter a mechanical stop. Impacting the mechanical stop could cause damage to the stage even at low speeds. 32 Chapter 3 www.aerotech.com

AMG-GR Hardware Manual Electrical Specifications and Installation Brake Specifications [BM and BMS motors with the brake option only] Supply Voltage 24 V Supply Current (typical) 500 ma (current required to release the brake and allow motion) Maximum Motor Bus Voltage AMG 100GR 150GR 200GR 300GR -BM Motor 80 VDC EL: 80 VDC 340 VDC AZ: 340 VDC -BMS Motor 340 VDC -SM Motor 40 VDC 1. If the -TRCNT option has been purchased for the Elevation Axis, the Max Motor Bus Exception (Notes) Voltage is 80 VDC, superseding the listings above. 2. For -SM motors with Aerotech controllers, amplifier bus voltages are 2X values listed. Table 3-8: Standard Rotary Motor Feedback Optional Direct Encoder Resolution Information Gear Ratio -M1, -M2, -M5. -M6 -M3, M4, -M7, -M8 Lines AMG100GR AMG150GR AMG200GR AMG300GR AZ 51:1 51:1 85:1 117:1 EL 51:1 51:1 67:1 85:1 Lines (2) AZ 2000 lines/rev 2000 lines/rev 2500 lines/rev 2500 lines/rev EL 2000 lines/rev 2000 lines/rev 2000 lines/rev 2500 lines/rev Stage Resolution AZ 62 µrad 62 µrad 30 µrad 22 µrad EL 62 µrad 62 µrad 47 µrad 30 µrad Lines (3) AZ 1000 lines/rev 1000 lines/rev 1000 lines/rev 1000 lines/rev EL 1000 lines/rev 1000 lines/rev 1000 lines/rev 1000 lines/rev Stage (1) Resolution AZ 0.062 µrad 0.062 µrad 0.037 µrad 0.027 µrad EL 0.062 µrad 0.062 µrad 0.047 µrad 0.037 µrad AZ 15744 lines/rev EL 15744 lines/rev 15744 lines/rev 15744 lines/rev 23600 lines/rev 18000 lines/rev 31488 lines/rev 23600 lines/rev -E1 (1,3) AZ 0.20 µrad 0.20 µrad 0.13 µrad 0.10 µrad EL 0.20 µrad 0.20 µrad 0.17 µrad 0.13 µrad -E2 AZ 20 µrad 20 µrad 13 µrad 10 µrad EL 20 µrad 20 µrad 17 µrad 13 µrad -E3 AZ 2.0 µrad 2.0 µrad 1.3 µrad 1.0 µrad EL 2.0 µrad 2.0 µrad 1.7 µrad 1.3 µrad 1. With x500 multiplication on -E1 encoder. 2. Square wave 3. Sine www.aerotech.com Chapter 3 33

Electrical Specifications and Installation AMG-GR Hardware Manual Table 3-9: AMG-GR Brushless Rotary Motor Specifications Performance Specifications (1,2) BM22 (AMG100GR [AZ/EL]) (AMG150GR [AZ/EL]) (AMG200GR [EL]) BM75 (AMG200GR [AZ]) (AMG300GR [AZ/EL]) Stall Torque, Continuous (3) N m (oz in) 0.16 (22.5) 0.51 (72) Peak Torque (4) N m (oz in) 0.48 (68.0) 1.3 (181) Rated Power Output, Continuous W 50 192 Electrical Specifications (2) BEMF Constant (Line-Line, Max) V pk /k rpm 3.9 9 Continuous Current, Stall (3) A pk (A rms ) 4.9 (3.5) 9.0 (6.4) Peak Current, Stall (4) A pk (A rms ) 14.7 (10.4) 22.5 (15.9) Torque Constant (5) Motor Constant (3,5) N m/a pk (oz in/a pk ) 0.032 (4.5) N m/(a rms (oz in/(a rms ) N m/ W (oz in/ W) 0.045 (6.4) 0.038 (5.37) 0.06 (8.0) 0.08 (11.4) 0.053 (7.52) Resistance, 25 C (Line-Line) Ω 0.67 1.0 Inductance (Line-Line) mh 0.73 0.80 Maximum Bus Voltage V DC 80 340 Thermal Resistance C/W 6.26 1.41 Number of Poles -- 8 8 1. Performance is dependent upon heat sink configuration, system cooling conditions, and ambient temperature 2. All performance and electrical specifications ±10% 3. Values shown @ 105 C rise above a 25 C ambient temperature, with housed motor mounted to a 250 mm x 250 mm x 6 mm aluminum heat sink 4. Peak torque assumes correct rms current; consult Aerotech 5. Torque constant and motor constant specified at stall 6. Maximum winding temperature is 130 C 7. Ambient operating temperature range 0 C - 25 C; consult Aerotech for performance in elevated ambient temperatures 8. All Aerotech amplifiers are rated Apk; use torque constant in N m/apk when sizing 34 Chapter 3 www.aerotech.com

AMG-GR Hardware Manual Electrical Specifications and Installation Table 3-10: AMG-GR Brushless, Slotless Rotary Motor Specifications Performance Specifications (1, 5) BMS35 (AMG100GR [AZ/EL]) (AMG150GR [AZ/EL]) (AMG200GR [EL]) BMS60 (AMG200GR [AZ]) (AMG300GR [AZ/EL]) Stall Torque, Continuous (2) N m (oz in) 0.27 (38.0) 0.33 (46.2) Peak Torque (3) N m (oz in) 1.07 (152.0) 1.31 (184.9) Electrical Specifications (5) Winding Designation -A -A BEMF Constant (Line-Line, Max) V pk /k rpm 12.9 19 Continuous Current, Stall (2) A pk (A rms ) 2.5 (1.7) 2.3 (1.6) Peak Current, Stall (3) A pk (A rms ) 9.8 (6.9) 9.2 (6.5) Torque Constant (4, 8) N m/a pk (oz in/a pk ) N m/a rms (oz in/a rms ) 0.11 (15.5) 0.14 (20.1) 0.15 (21.9) 0.20 (28.4) Motor Constant (2, 4) N m/ W (oz in/ W) 0.046 (6.52) 0.050 (7.02) Resistance, 25 C (Line-Line) Ω 5.8 8.4 Inductance (Line-Line) mh 1.7 1.30 Maximum Bus Voltage V DC 340 340 Thermal Resistance C/W 2.21 1.73 Number of Poles -- 8 8 1. Performance is dependent upon heat sink configuration, system cooling conditions, and ambient temperature 2. Values shown @ 75 C rise above a 25 C ambient temperature, with housed motor mounted to a 250 mm x 250 mm x 6 mm aluminum heat sink 3. Peak torque assumes correct rms current; consult Aerotech 4. Force constant and motor constant specified at stall 5. All performance and electrical specifications ±10% 6. Maximum winding temperature is 100 C (thermistor trips at 100 C) 7. Ambient operating temperature range 0 C - 25 C; consult Aerotech for performance in elevated ambient temperatures 8. All Aerotech amplifiers are rated Apk; use torque constant in N m/apk when sizing www.aerotech.com Chapter 3 35

Electrical Specifications and Installation AMG-GR Hardware Manual Table 3-11: AMG-GR Stepper Motor Specifications SM35-CN1 (AMG100GR [AZ/EL]) (AMG150GR [AZ/EL]) (AMG200GR [EL]) SM60-CN1-VT2 (AMG200GR [AZ]), (AMG300GR [AZ/EL]) NEMA Motor Frame Size 17 23 Stall Torque N m (oz in) 0.78 (111) 1.41 (200) Rated Phase Current A 3 0.84 Recommended Driver Bus Voltage V 48 160 Rotor Inertia kg m 2 (oz in s 2 ) 1.02 x 10-5 ( 0.0014) 3 x 10-5 (0.0042) Full Step Angle 1.8 1.8 Accuracy ±0.09 ±0.09 Maximum Radial Load N (lb) 28.4 (6.3) 75.4 (17) Maximum Thrust Load N (lb) 28.4 (2.2) 14.7 (3.4) Weight kg (lb) 0.50 (1.1) 0.70 (1.6) 36 Chapter 3 www.aerotech.com

AMG-GR Hardware Manual Electrical Specifications and Installation 3.4. Limits, Marker, and Machine Direction Aerotech stages are configured to have positive and negative "machine" directions. The machine direction defines the phasing of the feedback and motor signals and is dictated by the stage wiring (refer to Section 3.5. for Motor and Feedback phasing information). Programming direction of a stage is set by the controller that is used to move the stage. Programming direction is typically selectable in the controller, while machine direction is hardwired in the stage. Figure 3-2 shows the machine direction of AMG-GR stages. Figure 3-2: Machine Direction www.aerotech.com Chapter 3 37

Electrical Specifications and Installation AMG-GR Hardware Manual 3.5. Motor and Feedback Phasing Motor phase voltage is measured relative to the virtual wye common point. Figure 3-3: Hall Phasing 38 Chapter 3 www.aerotech.com

AMG-GR Hardware Manual Electrical Specifications and Installation Figure 3-4: Analog Encoder Phasing Reference Diagram Figure 3-5: Encoder Phasing Reference Diagram (Standard) www.aerotech.com Chapter 3 39

Electrical Specifications and Installation AMG-GR Hardware Manual This page intentionally left blank. 40 Chapter 3 www.aerotech.com

AMG-GR Hardware Manual Maintenance Chapter 4: Maintenance D A N G E R : To minimize the possibility of bodily injury or death, disconnect all electrical power prior to performing any maintenance or making adjustments to the equipment. 4.1. Service and Inspection Schedule Lubricant inspection and replenishment in AMG-GR series stages depends on conditions such as duty cycle, speed, and the environment. An inspection interval of once every two weeks is recommended until a trend develops for the application. Longer or shorter intervals may be required to maintain the film of lubricant on the worm threads. In general, stages that operate in a clean environment at 50% duty cycle or less must be lubricated monthly or every 75,000 revolutions (which ever comes first). For long-term reliability, we recommend that you return the stage to Aerotech after 300,000 rotation cycles for cleaning, relubrication, and gearing adjustments. For stages that operate at higher duty cycles, lubrication once every two weeks is recommended. If the application process uses only a small portion of travel for most of the duty cycle, periodically drive the stage through full travel to redistribute the lubrication in the bearingsand worm drive. Monthly inspections should include but not be limited to: Visually inspect the stage and cables. Re-tighten loose connectors. Replace or repair damaged cables. Clean the AMG-GR and any components and cables as needed. Repair any damage before operating the AMG-GR. Inspect and perform an operational check on all safeguards and protective devices. 4.2. Cleaning and Lubrication D A N G E R : To minimize the possibility of bodily injury or death, disconnect all electrical power prior to performing any maintenance or making adjustments to the equipment. Cleaning Before using a cleaning solvent on any part of the AMG-GR, blow away small particles and dust with nitrogen or, less preferably, clean, dry, compressed air. Any external metal surface of the AMG-GR can be cleaned with isopropyl alcohol on a lint-free cloth. W A R N I N G : Make sure that all solvent has completely evaporated before attempting to move the stage. www.aerotech.com Chapter 4 41

Maintenance AMG-GR Hardware Manual Lubrication For the worm gear drive mechanism, use Mobil Mobilith SHC 100 grease unless otherwise specified. AMG-GR rotary stages are designed for easy maintenance of the worm drive system. The drive mechanism can be lubricated while the stage is under power and integrated in upper level systems provided that access to the lubrication ports is maintained. Locations of the lubrication ports are shown in Figure 4-1. Prior to adding lubrication at the designated ports, make sure the surrounding surfaces are clean. While the stages rotate (<5 rpm), slowly inject approximately 6 cc's of lubricant into each of the stage s ports. Wipe clean any excess lubricant. Figure 4-2 shows the effect of the addition of lubricant to the current draw of a typical AMG-GR stage. With the added lubricant the resulting current pull is much smoother, leading to much better mechanical performance and maximum life of the product. Figure 4-1: AMG-GR Lubrication Ports Figure 4-2: View of the Current Draw of a Typical AMG-GR Stage Before and After Lubrication 42 Chapter 4 www.aerotech.com

AMG-GR Hardware Manual Maintenance 4.3. Troubleshooting Symptom Possible Cause and Solution Stage will not move Brake not released (if equipped with brake; refer to stage documentation). In Limit condition. Check limits (refer to Chapter 3) and refer to controller documentation for polarity and compatibility requirements (Example: voltage requirements). Controller trap or fault (refer to controller documentation). Stage moves uncontrollably Stage oscillates or squeals Encoder (sine and cosine) signal connections (refer to Chapter 3 and Controller documentation). Motor Connections (refer to Chapter 3 and Controller documentation). Gains misadjusted (refer to the controller documentation). Encoder signals (refer to the controller documentation). www.aerotech.com Chapter 4 43

Maintenance AMG-GR Hardware Manual This page intentionally left blank. 44 Chapter 4 www.aerotech.com

AMG-GR Hardware Manual Warranty and Field Service Appendix A: Warranty and Field Service Aerotech, Inc. warrants its products to be free from harmful defects caused by faulty materials or poor workmanship for a minimum period of one year from date of shipment from Aerotech. Aerotech s liability is limited to replacing, repairing or issuing credit, at its option, for any products that are returned by the original purchaser during the warranty period. Aerotech makes no warranty that its products are fit for the use or purpose to which they may be put by the buyer, whether or not such use or purpose has been disclosed to Aerotech in specifications or drawings previously or subsequently provided, or whether or not Aerotech s products are specifically designed and/or manufactured for buyer s use or purpose. Aerotech s liability on any claim for loss or damage arising out of the sale, resale, or use of any of its products shall in no event exceed the selling price of the unit. THE EXPRESS WARRANTY SET FORTH HEREIN IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE. IN NO EVENT SHALL AEROTECH BE LIABLE FOR CONSEQUENTIAL OR SPECIAL DAMAGES. Return Products Procedure Claims for shipment damage (evident or concealed) must be filed with the carrier by the buyer. Aerotech must be notified within thirty (30) days of shipment of incorrect material. No product may be returned, whether in warranty or out of warranty, without first obtaining approval from Aerotech. No credit will be given nor repairs made for products returned without such approval. A "Return Materials Authorization (RMA)" number must accompany any returned product(s). The RMA number may be obtained by calling an Aerotech service center or by submitting the appropriate request available on our website (www.aerotech.com). Products must be returned, prepaid, to an Aerotech service center (no C.O.D. or Collect Freight accepted). The status of any product returned later than thirty (30) days after the issuance of a return authorization number will be subject to review. Visit https://www.aerotech.com/global-technical-support.aspx for the location of your nearest Aerotech Service center. Returned Product Warranty Determination After Aerotech's examination, warranty or out-of-warranty status will be determined. If upon Aerotech's examination a warranted defect exists, then the product(s) will be repaired at no charge and shipped, prepaid, back to the buyer. If the buyer desires an expedited method of return, the product(s) will be shipped collect. Warranty repairs do not extend the original warranty period. Fixed Fee Repairs - Products having fixed-fee pricing will require a valid purchase order or credit card particulars before any service work can begin. All Other Repairs - After Aerotech's evaluation, the buyer shall be notified of the repair cost. At such time the buyer must issue a valid purchase order to cover the cost of the repair and freight, or authorize the product(s) to be shipped back as is, at the buyer's expense. Failure to obtain a purchase order number or approval within thirty (30) days of notification will result in the product(s) being returned as is, at the buyer's expense. Repair work is warranted for ninety (90) days from date of shipment. Replacement components are warranted for one year from date of shipment. www.aerotech.com Appendix A 45

Warranty and Field Service AMG-GR Hardware Manual Rush Service At times, the buyer may desire to expedite a repair. Regardless of warranty or out-of-warranty status, the buyer must issue a valid purchase order to cover the added rush service cost. Rush service is subject to Aerotech's approval. On-site Warranty Repair If an Aerotech product cannot be made functional by telephone assistance or by sending and having the customer install replacement parts, and cannot be returned to the Aerotech service center for repair, and if Aerotech determines the problem could be warranty-related, then the following policy applies: Aerotech will provide an on-site Field Service Representative in a reasonable amount of time, provided that the customer issues a valid purchase order to Aerotech covering all transportation and subsistence costs. For warranty field repairs, the customer will not be charged for the cost of labor and material. If service is rendered at times other than normal work periods, then special rates apply. If during the on-site repair it is determined the problem is not warranty related, then the terms and conditions stated in the following On-Site Non-Warranty Repair section apply. On-site Non-Warranty Repair If any Aerotech product cannot be made functional by telephone assistance or purchased replacement parts, and cannot be returned to the Aerotech service center for repair, then the following field service policy applies: Aerotech will provide an on-site Field Service Representative in a reasonable amount of time, provided that the customer issues a valid purchase order to Aerotech covering all transportation and subsistence costs and the prevailing labor cost, including travel time, necessary to complete the repair. Service Locations http://www.aerotech.com/contact-sales.aspx?mapstate=showmap USA, CANADA, MEXICO CHINA GERMANY Aerotech, Inc. Aerotech China Aerotech Germany Global Headquarters Full-Service Subsidiary Full-Service Subsidiary Phone: +1-412-967-6440 Phone: +86 (21) 3319 7715 Phone: +49 (0)911 967 9370 Fax: +1-412-967-6870 Fax: +49 (0)911 967 93720 JAPAN TAIWAN UNITED KINGDOM Aerotech Japan Aerotech Taiwan Aerotech United Kingdom Full-Service Subsidiary Full-Service Subsidiary Full-Service Subsidiary Phone: +81 (0)50 5830 6814 Phone: +886 (0)2 8751 6690 Phone: +44 (0)1256 855055 Fax: +81 (0)43 306 3773 Fax: +44 (0)1256 855649 Have your customer order number ready before calling. 46 Appendix A www.aerotech.com