Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Similar documents
Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

MasterINTERFACE 39 Series - Relay interface modules

40 Series - Miniature PCB relays A. Features

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

5 mm contact pin pitch PCB or 95 series sockets

90 Series - Socket overview for 60 series relays

2 pole 10 A PCB mount A1 A

60 Series - General purpose relays 6-10 A. Features SERIES

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

55 Series - Miniature General Purpose Relays 5-10 A

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

94 Series - Socket overview for 55 series relays

44 SERIES. PCB/Plug-in relays from 6 to 10 A

General purpose relays 6-10 A

General purpose relays 7-10 A

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Slim P.C.B. Relays (EMR or SSR) A

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Miniature Industrial relay 8-16 A

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

Surface mounting, flush mounting, and DIN track mounting

functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

Multi-function. Mono-function 1 NO (SPST-NO)

DEVICE STATE/BYPASSED FAILURE OVERLOAD

7E x0. Nominal current 5 A (32 A Maximum) 1-phase 230 V AC 17.5 mm wide

Electronic timers CT-E range Selection and ordering details

Electronic timers CT-S range Function diagrams

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

DIN EN UL 508 / CSA 3RF A A 0 2

Solid State Relays, 3-phase

Solid State Relays contactor with Integrated Fuse Type RGC1F

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Safety technique. Emergency Stop Module BH 5928, BI 5928

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

ASL09..S 3-pole Contactors - Spring Terminals

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

SIRIUS 3RU2 Thermal Overload Relays

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

Series 858, Relay Sockets with Industrial Relay

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

Vert-X 31E - 24V / 4-20mA. Applications Concrete pump Access control system Fork lift

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

CT-ranges. Content. Electronic timers. Benefits and advantages of the CT-ranges Selection and ordering details

RUC industrial relays of small dimensions

H3DS-X - Solid State Two-Wire Timer

AF40... AF96 3-pole contactors Technical data

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Meta Solution. Contactors and Overload relays

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Auxiliary contact blocks - with spring terminals Accessories

GB60S 60W Single Output General Purpose Series

Model Number Structure

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

1.1 Caution Statements

Pressure Transmitters

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Three-Phase Soft Starters

Technical Information

Softstarter Intelligent Controllers

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

TrustSight LED Emergency Lighting

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Pressure transmitter JUMO dtrans p02

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Electronic Timer - Series Micon 225 Signal Based Multi - Function

QUINT-PS/24DC/24DC/ 5/CO

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Reverse power relay and protection assemblies

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

Electronic pressure switch with two switching outputs

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Industrial Contactors CTX 3 3P 185A - 800A

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Power Electronics. Motor brake relay GA 9031 ministop

General Purpose Relay

MCD 200 Series Soft Starters

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Protection and control VIP30, VIP35. Relays technical manual

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

Transcription:

86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013 (protection against fire of materials), EN 61373 (resistance against random vibrations and shock, Category 1, Class B), EN 50155 (resistance to temperature and humidity, T1 class) Timer module: type 86.00T for 96 series sockets type 86.30T for 94, 96, 97 series sockets Wide supply voltage range: type 86.00T: 12 240 V AC/DC type 86.30T: 12 24 V AC/DC LED indicator Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets 86.00T 86.30T Time scale: from 0.05 s to 100 h Bi-function Plug-in for use with 94, 96 and 97 series sockets 86.00T AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on EE: Interval with control signal off FE: Interval with control signal on and off AI: On-delay DI: Interval Relay + socket Relay + socket Relay + socket 86.30T Wiring diagram (without control signal) Wiring diagram (with control signal) Wiring diagram * Short term (10 min) +70 C Contact specification Contact configuration Rated current/maximum peak current A Rated voltage/ Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA See 56T series relays See 46T, 55T, 56T series relays Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification Nominal voltage (U N ) V AC (50/60 Hz) 12 240 12 24 V DC 12 240 12 24 Rated power AC/DC W 1.2 0.15 Operating range V AC (50/60 Hz) 10.2 265 9.6 33.6 DC 10.2 265 9.6 33.6 Specified time range (0.05 1)s, (0.5 10)s, (5 100)s, (0.5 10)min, (5 100)min, (0.5 10)h, (5 100)h Repeatability % ± 1 ± 1 Recovery time ms 50 50 Minimun control impulse ms 50 Setting accuracy full range % ± 5 ± 5 Electrical life at rated load in AC1 cycles See 56T series relays See 46T, 55T and 56T series relays Ambient temperature range C 25 +55* 25 +55* IP 20 (according to type) 1

86 86 Timer modules Ordering information Example: 86 series multi-function timer module, (12 240)V AC/DC supply voltage. 8 6. 0 0. 0. 2 4 0. 0 0 0 0 T Series Type 0 = Multi-function timer (AI, DI, SW, BE, CE, DE, EE, FE) 3 = Bi-function timer (AI, DI) No. of poles See 46T, 55T, 56T series relays Poles for chosen relay/socket combination - according to chart below Supply voltage 024 = (12 24)V AC/DC (86.30T only) 240 = (12 240)V AC/DC (86.00T only) Supply version 0 = AC (50/60 Hz)/DC Combinations Number of poles Relay type Socket type Timer module 1 46.61T 97.01.7/97.P1.7 86.30T 2 46.52T 97.02.7/97.P2.7 86.30T 4 55.34T 94.04.7/94.P4.7 86.30T 2 56.32T 96.02.7 86.30T 4 56.34T 96.04.7 86.00T/86.30T EMC specifications Type of test Reference standard 86.00T 86.30T Electrostatic discharge contact discharge EN 61000-4-2 4 kv n.a. air discharge EN 61000-4-2 8 kv 8 kv Radio-frequency electromagnetic field (80 1000 MHz) EN 61000-4-3 10 V/m 10 V/m Fast transients (burst) (5-50 ns, 5 khz) on Supply terminals EN 61000-4-4 4 kv 2 kv Surges (1.2/50 µs) on Supply terminals common mode EN 61000-4-5 4 kv 2 kv differential mode EN 61000-4-5 4 kv 1 kv Radio-frequency common mode (0.15 80 MHz) on Supply terminals EN 61000-4-6 10 V 10 V Radiated and conducted emission EN55022 class B class B Other data 86.00T 86.30T Current absorption on signal control (B1) ma 1 Power lost to the environment without contact current W 0.1 (12 V) - 1 (230 V) 0.2 with rated current See 56T series relays See 46T, 55T, 56T series relays Times scales NOTE: Time scales and functions must be set before energising the timer. To achieve the minimum time setting of 0.05 seconds it is necessary to use one of the functions with control signal. When setting very short times it may be necessary to take into account the operate time of the relay used. 2

86 Timer modules 86 Functions U = Supply voltage S = Control signal LED Type 86.00T LED Type 86.30T Supply voltage OFF NO output contact Open = Output contact ON Open ON Open (Timing in Progress) ON Closed Without control signal = Start via contact in supply line (A1). With control signal = Start via contact into control terminal (B1). Wiring diagram Type 86.00T Without control signal (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. (SW) Symmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). With control signal * With DC supply, positive polarity has to be conneted to B1 terminal (according to EN 60204-1). Switch S should be exclusively used to provide the control signal to terminal B1. (Do not connect any other load at this point). * (BE) Off-delay with control signal. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. (CE) On- and off-delay with control signal. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Interval with control signal on. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. (EE) Interval with control signal off. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. (FE) Interval with control signal on and off. Both the opening and closing of the Signal Switch (S) initiates the transfer of the output contacts. In both instances the contacts reset after the delay period has elapsed. Wiring diagram Type 86.30T (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 3

86 96 94 94.04.7 Screw terminal (Box clamp) socket panel or 35 mm 94.04.7 SMA* (EN 60715) rail mount For relay type 55.34T Metal retaining clip 094.71 6-way jumper link 094.06 Identification tag 094.00.4 Timer modules 86.30T Rated values 10 A - 250 V 2 kv AC Screw torque Nm 0.5 Wire strip length mm 8 Max. wire size for 94.04.7 sockets solid wire stranded wire mm 2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 E U R O P E A N P A T E N T E U R O P E A N 6-way jumper link for 94.04.7 socket 094.06 Rated values 10 A - 250 V 094.06 4

96 94 86 94.P4.7 Push-in terminal socket 35 mm rail (EN 60715) mount 94.P4.7 SMA* For relay type 55.34T Metal retaining clip 094.71 2-way jumper link 094.52.1 2-way jumper link 097.52 Timer modules 86.30T Rated values 10 A - 250 V 2 kv AC Wire strip length mm 10 Min. wire size for 94.P4.7 sockets solid wire stranded wire mm 2 0.5 0.5 AWG 21 21 Max. wire size for 94.P4.7 sockets solid wire stranded wire mm 2 2 x 1.5 / 1 x 2.5 2 x 1.5 / 1 x 2.5 AWG 2 x 18 / 1 x 14 2 x 18 / 1 x 14 5

86 96 96.02.7 Screw terminal (Box clamp) socket 96.02.7 SMA* 96.04.7 SMA* panel or 35 mm rail (EN 60715) mount For relay type 56.32T 56.34T Metal retaining clip (supplied with socket - packaging code SMA) 094.71 096.71 6-way jumper link 094.06 Identification tag 095.00.4 090.00.2 Timer modules 86.30T 86.00T, 86.30T Rated values 12 A - 250 V 2 kv AC Screw torque Nm 0.8 96.04.7 Wire strip length mm 8 Max. wire size for 96.02.7 and 96.04.7 socket solid wire stranded wire mm 2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 96.02.7 + 56.32T + 094.71 + 86.30T 96.04.7 + 56.34T + 096.71 + 86.00T / 86.30T 6

96 97 86 97.01.7 Screw terminal socket 97.01.7 SMA* 97.02.7 SMA* panel or 35 mm rail (EN 60715) mount For relay type 46.61T 46.52T Metal retaining clip (supplied with socket - packaging code SMA) 097.71 8-way jumper link 095.18 Identification tag 095.00.4 Timer modules 86.30T Rated current 16 A - 250 V AC 8 A - 250 V AC 6 kv (1.2/50 µs) between coil and contacts Screw torque Nm 0.8 Wire strip length mm 8 Max. wire size for 97.01.7 and 97.02.7 sockets solid wire stranded wire mm 2 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 97.01.7 + 46.61T + 097.71 + 86.30T 97.02.7 + 46.52T + 097.71 + 86.30T 7

86 96 97 97.P1.7 Push-in terminal socket 97.P1.7 SMA* 97.P2.7 SMA* panel or 35 mm rail (EN 60715) mount For relay type 46.61T 46.52T Metal retaining clip (supplied with socket - packaging code SMA) 097.71 2-way jumper link 097.52 2-way jumper link 097.42 Timer modules 86.30T Rated current 10 A - 250 V AC 8 A - 250 V AC 6 kv (1.2/50 µs) between coil and contacts Wire strip length mm 8 Min. wire size for 97.P1.7 and 97.P2.7 socket solid wire stranded wire mm 2 0.5 0.5 AWG 21 21 Max. wire size for 97.P1.7 and 97.P2.7 sockets solid wire stranded wire mm 2 2 x 1.5 / 1 x 2.5 2 x 1.5 / 1 x 2.5 AWG 2 x 18 / 1 x 14 2 x 18 / 1 x 14 97.P1.7 + 46.61T + 097.71 + 86.30T 97.P2.7 + 46.52T + 097.71 + 86.30T 8