Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Similar documents
Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical data sheets

Technical data sheets

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

POWER kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

PowerValue 11/31 T kva

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

1.1 GENERAL CHARACTERISTICS

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

EFFEKTA Power Supplies

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

TLE Series UPS 400/500 kw With eboost Technology

TECHNICAL DATA SHEET KVA UPS Systemss

Master Plus kva

PowerWave 33 Efficient power protection for today s IT and process-related work environments

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Master Plus kva

MASTERYS IP+ 10 to 80 kva

Industrial PFC UPS System

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

ConceptpowerTM Modular kVA

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

PowerScale kva Technical Specifications

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

PowerScale TECHNICAL SPECIFICATIONS

MGE TM Galaxy TM 7000 GFC

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

D Series: UPS UPTO - 300KVA - Three / Three Phase

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

UPS Multi Sentry 10-20kVA

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

POWERTRONIX QUASAR 5-40 KVA

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

Master MPS kva kva 3:1 3:3 VFI TYPE

Est FlexiPower Mini UPS FPX Mini kVA

Green Power 2.0 MASTERYS GP

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

MGE TM Galaxy TM 7000

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

Three Phase UPS Systems Range: 10 to 500kVA

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

PowerWave 33, kw

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

UPS Multi Power 1-28 x 42 kw up to 1MW

Master MPS kva kva 3:1 3:3 VFI TYPE

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

60 to 160 kva.

Phase Modular Finally the benefits of Modular ups are for all

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Liebert. FP 50Z kva

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

MKN-DSP SERIES - THREE PHASE

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

YOUR POWER IN SAFE HANDS. E Series UPS

UPS5000-E (25-75 kva) Series

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification

Transcription:

Technical Data Sheet Uninterruptible Power Supply TLESM_030-180_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gecriticalpower.com imagination at work

Model: Issued by: Approved by: TLE Modular Series 30-180 kva CE S1 Product Document Department Riazzino - CH R & D Department Riazzino - CH Date of issue: 13.04.2017 File name: GE_UPS_TDS_TLE_MCE_30K_M18_1GB_V020 Revision: 2.0 Identification No.: Up-dating Revision Concern Date 2.0 Connectivity and packaging update 13.04.2017 COPYRIGHT 2017 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/5

DESCRIPTION The TLE Modular Series UPS provides a compact footprint of less than 2m 2 with maximum capacity of 180kVA with best reliability and high performance. TLE Modular Series is considered to be the best power protection solution. FEATURES Modular design with N+X redundancy, on-line and hot-swappable. High power density with footprint of less than 2m 2 up to 180kVA. 30kVA power module with only 3U height. Paralleling up to 540kVA (3 cabinets). Green and energy saving: ECO mode efficiency 99%, on-line >95%. Excellent input performances: power factor >0.99 while THDi <3%. Wide accepted input voltage range for maximum compatibility with stressing mains. Superior Battery Management enhances battery lifetime resulting in reduced cost of operation. Battery cold start: UPS can be powered on from the battery without mains. Lifetime monitoring of critical components, such as fans and capacitors. Independent LCD display for each power module with self-starting function. 9 signalling voltage-free contacts (4 programmable by user). User-friendly colour touch screen of 10.4 inches. Modifications reserved Page 3/5

SPECIFICATION Model Capacity Power Module type TLE Modular Series 30 180 kva CE S1 30 180 kva, up to 540kVA with 3 parallel cabinets 30PM General data System efficiency Normal mode: >95%, ECO mode: 99%, Battery mode: 95% Cooling air at PF=0.9 (25 C 30 C, Normal Mode) m 3 /h 30kVA: 700 60kVA: 1228 90kVA: 1756 120kVA: 2284 150kVA: 2812 180kVA: 3340 Cooling air at PF=0.9 (25 C 30 C, ECO Mode) m 3 /h 30kVA: 554 60kVA: 713 90kVA: 871 120kVA: 1030 150kVA: 1188 180kVA: 1346 Display 10.4 LCD colour touch screen IP Class IP20 Interface 9 signalling voltage-free contacts (4 programmable) and SNMP card Operating temperature range UPS: 0 C 40 C Storage temperature range UPS: -40 C 70 C Battery: -20 C 40 C (higher the temperature, shorter the storage time of the battery) Relative humidity 0 95% (non-condensing) Altitude of operation 1000m / 1500m: -2.5% / 2000m: -5% / 2500m: -7.5% / 3000m: -10% General safety requirements for UPS used in operator access areas IEC/EN 62040-1/A1 Electromagnetic compatibility (EMC) requirements for UPS IEC/EN 62040-2 (C3) Method of specifying the performance and test requirements of UPS IEC/EN 62040-3 Transport On pallet- Cabinet suitable for handling by forklift External cable connections Top and bottom cable entry Audible noise level 65dB with 100% load / 62dB with 45% load (at 1 meter) Colour RAL 9005 (black) Paralleling Up to 3 cabinets (option) Input Phase 3 Phases + Neutral + Ground Voltage 380V / 400V / 415V (phase - phase) Frequency 50 / 60Hz Power factor >0.99 THDi THDi<3% with 100% linear load Voltage range 304Vac 478Vac (phase - phase), full load 228Vac 478Vac (phase - phase), 75% load Frequency range 40Hz 70Hz Output Voltage 380V / 400V / 415V (programmable) THDu THD <1% with linear load / THD <5% with non-linear load Power factor 0.9 Crest factor 3:1 Overload Capability 110% for 1 hour / 125% for 10 minutes / 150% for 1 minute / >150% for 200ms Short-circuit characteristic 2.7 times for 200ms between phase/phase and phase/n/pe Bypass Input connection Separate for rectifier and bypass input or common to the rectifier input Primary components Static switch (SCR) on bypass Electromechanic contactor (backfeed protection) on bypass Overload on bypass 110% Long term operation / 110% 125% for 5min. / 125% 150% for 1min. / 150% 400% for 1sec. / >400%, less than 200ms ICC (short circuit current capability) Static bypass: 40kA Maintenance bypass: 10kA Output UPS power versus power factor for: Inductive loads Resistive loads Capacitive loads Modifications reserved Page 4/5

Battery Battery type Valve regulated lead-acid (VRLA), NiCd and Li-ion on request Float voltage at 20 C 436V 545V (dependent on the number of cells) Number of cells VRLA at 2.27V/cell: 192 240 cells Min. discharge voltage (programmable) 320V 400V (dependent on the number of cells) Recharge current Up to 20% of the rated output power of PM (kw), programmable Recharge time <5 hours up to 80% of battery capacity Longer recharge time for long autonomy time / high load conditions Automatic and manual battery test Standard Common battery in parallel system Up to 3 cabinets (with same output power rating) Battery power data kva 30 60 90 120 150 180 DC power at full load & PF=0.8 lag. / PF=0.9 lag. kw 25.3/28.4 50.5/56.8 75.8/85.3 101.0/113.7 126.3/142.1 151.6/170.5 Maximum discharge current (1.65V/cell) Amps 80/90 159/179 239/269 319/359 399/448 478/538 EXTERNAL BATTERY TABLE Battery autonomy (0.8 PF full load) *) 10 year design life batteries UPS (kva) 1x33Ah *) 2x33Ah *) 3x33Ah *) 30 20 min. 42 min. 66 min. 60 8 min. 20 min. 31 min. 90 4 min. 12 min. 20 min. 120-8 min. 14 min. 150-5 min. 10 min. 180-4 min. 8 min. Battery cabinet Dimensions 790 x 1100 x 1600 mm (W x D x H) Weight 725 kg 1135 kg 1550 kg Floor loading 835 kg/m 2 1306 kg/m 2 1785 kg/m 2 Dimensions and weights 600mm 1100mm Net weight Cabinet Power module 30 kva 170Kg 34Kg 1600mm Dimension (W x D x H) Cabinet Power module 30 kva 600 x 1100 x 1600mm 460 x 790 x 134mm Protections Protections for mains voltages (3 x 380V / 400V / 415 Vac) UPS model Mains Input Bypass Input Common Input Mains External Battery TLE Modular Series 180/30 3 x 50A 3 x 50A 3 x 50A 3 x 80A TLE Modular Series 180/60 3 x 100A 3 x 100A 3 x 100A 3 x 160A TLE Modular Series 180/90 3 x 160A 3 x 160A 3 x 160A 3 x 250A TLE Modular Series 180/120 3 x 200A 3 x 200A 3 x 200A 3 x 300A TLE Modular Series 180/150 3 x 250A 3 x 250A 3 x 250A 3 x 355A TLE Modular Series 180/180 3 x 315A 3 x 315A 3 x 315A 3 x 400A Cable sections Cables section (mm 2 ) / IEC 60950-1 Local Standard and cables installation disposal shall be applied UPS model Mains Input Bypass Input Common Input Mains Mains Output External Battery TLE Modular Series 180/30 3 x 10 + 10 4 x 10 4 x 10 + 10 4 x 10 + 10 3 x 16 + 16 TLE Modular Series 180/60 3 x 25 + 16 4 x 25 4 x 25 + 16 4 x 25 + 16 3 x 50 + 25 TLE Modular Series 180/90 3 x 50 + 25 4 x 50 4 x 50 + 25 4 x 50 + 25 3 x 120 + 70 TLE Modular Series 180/120 3 x 70 + 35 4 x 70 4 x 70 + 35 4 x 70 + 35 3 x 150 + 95 TLE Modular Series 180/150 3 x 120 + 70 4 x 120 4 x 120 + 70 4 x 120 + 70 3 x 185 + 95 TLE Modular Series 180/180 3 x 150 + 95 4 x 150 4 x 150 + 95 4 x 150 + 95 3 x 240 + 120 Modifications reserved Page 5/5