Lesson 4 Configuring the system. copy right reserved by GoodWe

Similar documents
Introduction of EzManage Application

Goodwe 5048ES with BYD B-BOX (2.5-10) Installation Guide

PV Master OPERATION MANUAL

GOODWE & PYLONTECH ENERGY STORAGE

BYD Battery-Box LV Installation Guidance

SH5K+ Hybrid Inverter Overview & Installation.

@SOLAXEUROPE /SOLAXEUROPE /SOLAXPOWER

PV-Wind SOFTWARE for Windows User s Guide

BP SERIES USER MANUAL

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

ContiFI - ContiFleetInspection -

Hybrid System. Photovoltaic Inverter kW Series. Goodwe Quality, Good Value, Good Service, GoodWe! Official website Company Wechat

Online Monitoring Webserver V1.0

Using Apollo Solar Remote Monitoring Software

User Manual WatchPower App

B-Box Pro 2.5~10.0 User Manual

BYD Battery-Box LV User Manual Battery-Box L 3.5/7.0/10.5/14.0

On and Off Grid Interactive Features AC Coupling

B-Box Pro 2.5~10.0 User Manual

Support. EMROL Your power partner

B-Box Pro 13.8 User Manual

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

Advanced Hybrid Wind / Solar Charge Controller. User Manual

How To Set Up SimpliPhi Batteries Using OutBack Chargers

B-Box Res 2.5~10.0 User Manual

SimpliPhi Power PHI Battery

SimpliPhi Power PHI Battery INTEGRATION GUIDE: OUTBACK POWER. Power. On Your Terms.

MANUAL. Road User Portal (RUP) - Order an On Board Unit. (Free of charge from Belgium and neighbouring countries)

Power Whenever You Need

System Advisor Model (SAM) SimpliPhi Power Battery Modeling Instructions

ANIT-REVERSE CURRENT SOLUTIONS

SimpliPhi Power PHI Battery

BYD Battery-Box Pro User Manual Battery-Box Pro 13.8

BP SERIES USER MANUAL

AC THOR or AC ELWA -E

SimpliPhi Power PHI Battery

The power to be independent. Grid Independence Outstanding Reliability Ultimate Flexibility

Pilot document v1 Jan Fleet Manager User Guide

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

User Manual. Hydro Charger and Solar Hybrid Charge Controller

User Guide Electronic Logging Device

BYD Battery-Box LV Compatible Inverter List Battery-Box L 3.5/7.0/10.5/14.0

Franciscusdreef 42C 3565AC Utrecht

EM QUICK INSTALLATION INSTRUCTIONS

Power Whenever You Need

This reference document will help you navigate the new Electric Circuit application.

SolarEdge Solution - Making PV Panels Smarter GGS. Greener Gas Scotland Renewables & Heating

BMS-3923 Battery Monitoring System

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External

IMEON 9.12 USER MANUAL

FLEXnet DC Programming & Guidelines

27/10/2015 GENERAL. A. Yes. Z21 is a single phase unit, it will however operate correctly on any phase.

B-Box Pro 2.5~10.0 User Manual

Grade Marks Tab. Grade Marks Tab

ESS design & installation manual

:43 1/13 Victron & BYD B-Box

SNMP dedicated to ORVALDI Solar Infini

ESS Design & installation manual

BMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW

ME-ARC. Remote Control. Owner s Manual (for Revision 2.1 or higher) Inverting

Quick User Manual SH3K6 / SH4K6 Grid-Connected Hybrid Inverter

Installation Guidance

T P M S. Multi Wheel Bluetooth. Tire Pressure Monitoring System. User Manual. Model: External

Powervortex 3100/3700TL. Next generation solar battery hybrid inverter and system solution. User Manual Version 1.0

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems. IntelliSens App

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

App Manual Solution Features

UFIRST PERODUA PASSPORT USER MANUAL MEMBER PORTAL

SP PRO ABB Managed AC Coupling

Residential Energy Storage System PowCube 4.8

User Manual. Hybrid PV Inverter. Version: 2.1

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Room Controller LS 990 / LS plus Stainless Steel / Aluminium

SolarPower. User Manual. Suitable Products: Three-phase grid-tie inverter with energy storage. Three-phase off-grid inverter

User Manual 1KVA-5KVA INVERTER / CHARGER

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Growatt Storage Plus. Marketing Dept. Aug 2014

BMW i Wallbox Connect

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Solar Hybrid Inverter SP Brilliant Grid Series

Professional Wind & Solar Hybrid Controller Manual

Enter your and password then drag the car to the right.

Segen Storage Guide. Contact Segen e: w:

CRAGG RAILCHARGER Instruction Manual for 20SMC-12V 20SMC-24V 40SMC-12V 40SMC-24V 60SMC-12V 80SMC-12V

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

There is a Certification menu option that indicates that the mobile APP, mobile device used were self-certified according to federal requirement.

HOS Mobile App Driver s Guide. pg 1

LEADING BATTERY ENERGY STORAGE SOLUTIONS AVAILABLE FROM FREEDOM WON (DATA SHEETS AVAILABLE UPON REQUEST) Freedom Lite Home & Business

Power Whenever You Need

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE. / Perfect Welding / Solar Energy / Perfect Charging

Lithium Power Pack LITHIUM-ION BATTERY SYSTEM. With epro Plus Battery Monitor

Battery & Energy Meter Quick Guide

With Cummins PowerCommand Cloud, you can ensure you are always on.

EV Display User Guide

S-BP QUICK INSTALLATION INSTRUCTIONS

The Leading UK Manufactured Water-Craft Tracking System USER GUIDE

Solar Hybrid Inverter SP Efecto Series

3KW Off-grid Solar Power System LFP Battery

User manual Suppliers evaluation process

Transcription:

51

3. Run the APP EzManage.

4. Series Selection Page: When the APP is first used, it will pair with the inverter automatically when connecting to the inverter s WiFi. If the APP stays at the series selection page for more than 10 seconds, please manually choose the correct series. ES Series is the option for GoodWe ES inverter; BP Series is the option for GoodWe BP inverter; Note: If the incorrect series is selected, please restart the APP.

5. When the inverter is first installed, we need to configure the parameters of the inverter and battery. Click Help, and then Booting Settings. 6. Click Installer, type in the password: goodwe2010. The password is only for distributors and installers.

7. The first page of the app will show you if the WiFi connection is good. If not, please check your WLAN settings. Note: 1. Before configuring the battery parameters, please refer to the specification of the battery first. 2. If any setting is changed, click Set to save. Click Next to enter the Battery Settings page.

8.1 Battery Settings Battery Model: Click on the drop-down menu, five options will be listed: Default, BYD B-Box, LG RESU6.4X, PYLON Extra2000, Hoppecke. For example, choosing BYD-BOX, the charging, discharging and float charge settings will be changed to preset settings, click Set to save the charge/ discharge and float charge settings (The preset settings have all been tested and approved by the battery manufacturers). Battery capacity will not be changed automatically, please type in the capacity of the battery bank. Note: If the battery brand has been chosen, please do not change any settings below, just press Set.

8.1 Battery Settings Battery Model: Default/ BYD B-Box/ LG RESU6.4X/ PYLON Extra2000/ Hoppecke. If the battery is not any of the brands listed, please choose Default. All settings need to be changed manually.

If the battery brand can not be found in the list, please choose Default, the charge/ discharge /float charge parameters need to change manually. Charge Settings Battery Capacity: Capacity of the battery bank connected to the inverter, range is 50~1000Ah; Charge Voltage: The maximum voltage of the battery can be charged to, range is 50~60V; Charge Current: The maximum charge current of the battery, range is 0A<0.15*Capacity<50A;

8.1 Discharge Settings Discharge Voltage: The minimum voltage the battery will be discharged to, range is 40~48V; Discharge Current: The maximum discharge current of the battery, range is 0~50A; Discharge Depth: The maximum percentage of the battery can be discharged, range is 10~90(%);

8.1 Float Charge Settings Floating Voltage: Voltage to balance the charge/ discharge of the battery, range is 48~60V; Floating Current: Current to get ready for floating charge mode; Floating Time: Since the charge current is smaller than the floating charge current, after the floating charge period, the inverter will get into floating charge mode.

8.2 Advanced Settings Battery Discharge Mode - Day and Night: Day and Night/Night Only, battery can be discharged, whether PV is on or off; Battery Discharge Mode Night Only: Night Only, when PV is generating, battery can not be discharged.

8.3 Overview Parameters After configuring the parameters, please check if the battery settings are all correct. Note: If any setting is incorrect or failed to save into the inverter, there will be an exclamation mark in front of the setting. Please change the setting and press Set.

Lesson 4 Work Status Overview 8.2 Electric Parameters Click Param to enter the electric parameters page, four options will be listed, PV, BP Inverter, Battery and Power Parameters, click any of these and you will see its operating status.

Lesson 4 Other Options 8.2 Help Page Contact: GoodWe Global contact information Version: The version of the application; if new version is released, please update to the latest.

Lesson 5 System monitoring 65

Lesson 5 System monitoring Portal registration and monitoring 66

Lesson 5 System monitoring Registration The Ezlogger is ready to transport data to the GoodWe server. Follow steps below to register an account and create a station on the GoodWe portal. 1. Browse website: http://www.goodwe-power.com/ 2. Click Register.

Lesson 5 System monitoring Registration 3. Click User Type, choose Terminal User and fill all required fields.

Lesson 5 System monitoring Registration 4. Click Register and station setup page will come out.

Lesson 5 System monitoring Registration 5. Fulfill the Station Information, then go to Maintain Ezlogger. Input the S/N, Check Code, Type and Description. And click Add. 6. Type in the rest of the information and press button Create Station.

Lesson 5 System monitoring Registration 7. Login the portal, and choose the station just built. As this is a hybrid system, choose the hybrid inverter page, and then you can view the whole system working state at anytime anywhere.

Lesson 5 System monitoring ES system station overview

Lesson 5 System monitoring App monitoring - EzViewer