Similar documents
Intelliview IV on NH Guardian Sprayers Display Kit Installation Manual 54VT-IV-SP01

John Deere GS2 2600, 1800 and GS JD 4630 Display Kit Installation Manual GS2-SP02

Topcon X30 Display Kit Installation Manual 54VT-TC-X30

Trimble FMX Display Kit Installation Manual 54VT-TB-FMX

AGCO América do Sul (Factory Install) Installation Manual SP01

Rogator Passive Roll (2012+) 3 Height Sensors Installation Manual RG10

Rogator Passive Roll (2012+) 5 Height Sensors Installation Manual RG11

Nitro (4000 Series) Installation Manual NT04

Miller Condor & New Holland Rear Mount Truss Boom Installation Manual MC02

John Deere (4730 & 4830) with Proportional Main Lift Installation Manual JD08

Rogator Active Roll (2012+) Installation Manual RG12

Hagie (STS 90/ ) Installation Manual HG03

Case IH (4420, 3320) Installation Manual CS03

Goldacres Passive Roll G8 Installation Manual GA02

Top Air (TA 1200/1600, 80/90 Boom) Installation Manual TA01

Hardi North America/Australia AutoHeight Installation Manual HD03

Rogator Passive Roll (2012+) 5 Height Sensors Installation Manual RG11

John Deere R4030, R4038 and R4045 Installation Manual JD12

EVRARD Auto Slant End User Installation Manual EV5-E

John Deere (4730 & 4830) Active Roll with Proportional Main Lift Installation Manual JD08A

Spray Height Control System

Fast Standard Control Installation Manual FT4

HARDI Economy EAGLE Installation Manual HD9

Spray Height Controller

SUMMERS Pull-Type with Proxy Switch Sense Installation Manual SM2

Spray Height Controller

Hagie 264, 284XP, DTS8, 2100, 2101, DTS10 Installation Manual HG2

MS Sprayers NT 1000/1250 Installation Manual MS1

FLEXI-COIL 67 Series (1999+) Installation Manual FC1

Rogator 854, 1054 & 1254 Series Installation Manual RG4

Rogator 64 and 74 Series and Willmar Eagle 8650 (JIC) & 84, 94 & 1386 Series (Flat Faced O-Ring) Installation Manual RG2 & RG6

John Deere 4730, 4830 Installation Manual JD8

Hardi Europe AutoSlant DAH or DAH09 Installation Manual HD5

Top Air (1200/ /90 ft Boom) Installation Manual TA1

Spray Height Controller

Spray Height Controller

Case IH 3150, 3185, 3200, 3310, Tyler Patriot Installation Manual CS2

Spray Height Controller

Spray Height Controller

Spray Height Control Systems. Unprecedented spray height accuracy combined with the control you need. Guaranteed.

Spray Height Controller

Spray Height Controller

Spray Height Control System

Spray Height Controller

Spray Height Controller

BOOM HEIGHT CONTROL PRECISION DEFINED SPRAYING REFINED

Spray Height Control System

Hardi. Precision Defined. precision Spray Height Control

Spray Height Controller

UC4. Total Control Automatic Boom Height System. Redball 690 (2006+) Installation Manual

NORAC Rogator Operator s Manual

UC4. Total Control Automatic Boom Height System. Raptor Pro 1200 (2004) Installation Manual

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

Installation Instructions RF4510-EA

UC4. Total Control Automatic Boom Height System. NITRO (Miller 200 Series 1999+, 120-ft Boom) Installation Manual

WVC. Wireless Valve Controller. Multiple Station Battery Powered Irrigation Controller. Owner s Manual and Installation Instructions

V-D2425 and V-D2440 Digital Clock

Expansion Signal (XSIG) Card Installation Instructions

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

F5 Platforms: FIPS Kit Installation MAN

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

LED Recessed Troffer Retrofit Kit

Cab Control Operators Manual

TPMS (Tire Pressure Monitoring Systems)

Hendrickson Fit Adapter Installation Instructions

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents:

To ensure correct operation and service please read these instructions before installing and operating the TPMS P451 TPMS Manual TABLE OF CONTENTS

IVTM Installation Manual

SpeedPuck Manual. Firmware Version v1.4

QUICK REFERENCE MANUAL

MONOPRICE. Power Cache 220 Solar Power Generator. User's Manual P/N 15278

Cab Control 2.4 Operators Manual

Spray Height Controller

Installation Instructions for VTU

pro user guide 940H Student Microphone 940C Microphone Charger

This page intentionally left blank. Cab Control 400

MIC210 Electric Farm Conversion Instructions

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

To ensure correct operation and service please read these instructions before installing and operating the TPMS. TPMS Manual

Audio Operator Interface Installation Instructions

ASSA ABLOY. Access 600 Integrated Wiegand. with MELR Option (Electric Latch Retraction) Access 600 Integrated Wiegand ASSA ABLOY.

TC26-B Vehicle Sensor

V-DW2425A / V-DW2440 and V-DW11025A / V-DW11040A

Smart Sensor Pro+ User Guide

Parts Book Spray Height Control Systems Effective Date: October 1, 2014 precision Spray Height Control

Lumination TM LED Luminaire LUR Series

USER MANUAL Revision A 25/05/2013

Tractor Interface Module Installation Instructions. Switch Input (TIM-SI)

Powerware Vdc Extended Battery Cabinet User s Guide.

Monnit Wireless Range Extender Product Use Guide

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Select II Portable Braking System

LED Utility Wrap Fixture

Installation Guide(s)

A419ABG-3C Electronic Temperature Control

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

MAPNET II Transceiver Installation Instructions

SLTC24-FM (2.4GHz) Torque Wrench Operating Instructions

Transcription:

54VT-TC-X30 Topcon X30 Display Kit Installation Manual

Printed in Canada Copyright 2010 by NORAC Systems International Inc. Reorder P/N: 54VT-TC-X30-INST Rev D (Topcon X30 Display Kit) NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.

Contents 1 INTRODUCTION... 2 1.1 List of Parts...2 2 TECHNICAL SPECIFICATIONS... 3 3 INSTALLATION... 4 3.1 CANbus Interface Installation...4 3.2 Switch Box Installation...5 4 CABLE DRAWINGS... 6 4.1 ITEM C25: 44602-01 Switch Remote Hand Control...6 4.2 ITEM C26: 43240-26 Cable UC5 Switch Box...7 4.3 ITEM C40: 43260-08 Cable UC5 Interface CANbus 4-Pin Deutsch...8 5 APPENDIX A: ALTERNATE CONFIGURATION... 9 1

1 Introduction The Topcon X30 Display Kit Manual is intended to be used in conjunction with the UC5 Spray Height Control Installation Manual. This manual provides instructions to interface the UC5 Control Module to the Topcon X30 Display. For installation of the rest of the UC5 Spray Height Control System please refer to the sprayer specific manual provided with the kit. 1.1 List of Parts Item Part Number Name Quantity C25 44602-01 BOX SWITCH UC4 REMOTE HAND CONTROL VER.1 RMR 1 C26 43240-26 CABLE UC5 INTERFACE SWITCH BOX 1 C40 43260-08 CABLE UC5 INTERFACE CANBUS 4 PIN DEUTSCH 1 M01 UC5-BC-MANUAL-ECHO-VT MANUAL UC5 OPERATORS - ECHO/VT 1 M04 54VT-TC-X30-INST MANUAL UC5 DISPLAY KIT TOPCON X30 1 2

2 Technical Specifications CAN ICES-3(A)/NMB-3(A) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense. This Class A digital apparatus complies with Canadian ICES-003. Pursuant to EMC Directive Article 9, this product is not intended for residential use. Table 1: System Specifications Supply Voltage (rated) 12VDC Supply Current (rated) 10A Hydraulic Pressure (maximum) 3300 psi Baud Rate 250 kbps Clock Frequency (maximum) 96 MHz Solenoid Valve PWM Frequency 300 Hz Ultrasonic Sensor Transmit Frequency 50 khz Operating Temperature Range 0 C to 80 C 3

3 Installation 3.1 CANbus Interface Installation 1. Securely mount the control module (E01) in the cab of the sprayer. 2. Tee the CANbus interface cable (C40) in to the CAN 1 connection on the Topcon wiring harness. 3. Connect the Deutsch plug on cable C40 to the end of the control module with only one Deutsch connector. Figure 1: CANbus Interface Installation 4

3.2 Switch Box Installation 1. Disconnect cable C20 (Thru 2 connector) from the Input Module (E03). Remove the wedge from the face of the 12 pin Deutsch plug. 2. Insert the Roll CW pin from C26 into position 3 of the 12 pin plug on C20. Insert the Roll CCW pin from C26 into position 4 of the 12 pin plug on C20. Insert the wedge back into the plug. Connect C20 to the Thru 2 connector on the Input Module. 3. Connect the 12 pin Deutsch plug on C26 to the OEM 3 connector on the input module. Route the other end of the cable to the hitch of the sprayer (pull type) or to the cab (self propelled). 4. Attach the switch box (C25) inside the cab and connect it to cable C26. An extra label is provided with the switch box if you prefer to remove the switches from the housing and mount them in the existing sprayer switch panel. * Some sprayer types may not use all the switch functions. * Refer to Appendix A for sprayers with European style slant control. Figure 2: Switch Box Installation 5

4 Cable Drawings 4.1 ITEM C25: 44602-01 Switch Remote Hand Control 6

4.2 ITEM C26: 43240-26 Cable UC5 Switch Box 7

4.3 ITEM C40: 43260-08 Cable UC5 Interface CANbus 4-Pin Deutsch 8

5 Appendix A: Alternate Configuration If your sprayer has European style slant control, you will need to reconfigure the switch box as shown below. This is only required for sprayer types which are driving the slant output from the Input Module. Reconfigure the pins on cable C26 as follows: Function (Cable C26) Wire Color Normal Configuration European Style Slant Configuration Connector Pin Location Connector Pin Location Power White Grey End (C26) 1 Grey End (C26) 1 Ground Black Grey End (C26) 12 Grey End (C26) 12 Remote Auto Brown Grey End (C26) 11 Grey End (C26) 11 Remote Manual Blue Grey End (C26) 10 Grey Side (C20) 4 Main Up Purple Grey End (C26) 9 Grey End (C26) 9 Main Down Yellow Grey End (C26) 8 Grey End (C26) 8 Roll CW Red Grey Side (C20) 3 Grey End (C26) 6 Roll CCW Orange Grey Side (C20) 4 Grey End (C26) 10 9

Canada NORAC Systems International Inc. Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921 Shipping Address: 3702 Kinnear Place Saskatoon, SK S7P 0A6 United States NORAC, Inc. Phone: (+1) 952 224 4142 Toll Free: 1 866 306 6722 Shipping Address: 6667 West Old Shakopee Road, Suite 111 Bloomington, MN 55438 Europe NORAC Europe Phone: (+33) (0)4 26 47 04 42 Shipping Address: Rue de l hermitage 01090 GUEREINS France www.norac.ca