D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

Similar documents
Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4BS CSM_D4BS_DS_E_8_4

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

2NC (slow-action) Direct. Model. opening

D4GS-N CSM_D4GS-N_DS_E_7_2

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4NH CSM_D4NH_DS_E_7_1

2NC (slow-action) Direct. Model. opening

CSM_D4N-_R_DS_E_6_1

Safety Limit Switch

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4BL. Guard Lock Safety-door Switch

Multiple Limit Switch

D4NL. Guard Lock Safety-door Switch. Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

D4BL. Guard Lock Safety-door Switch

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

D4NS. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Safety-door Switch. Model Number Structure

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety Limit Switch

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Safety-door Switch. Ordering Information

A165E CSM_A165E_DS_E_11_2

Safety Guard Switching Unit G9SX-GS

Digital display Pressure range ON/OFF output Linear output Model

D4NL CSM_D4NL_DS_E_9_2

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key

Manual Reset Limit Switch

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

A4EG CSM_A4EG_DS_E_6_1

G3PE-Single-phase. Solid State Relays for Heaters

Hinged Safety Door Switch

A22LK CSM_A22LK_DS_E_6_2

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

Model Number Structure

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4NL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key \ Lead-free, Environment-friendly Design

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

DIN Track Terminal Blocks with Screw Terminals XW5T

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

EStrong-series Emergency Stop

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals XW5T

Machine & Process Safeguarding Solution Selection Guide

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

Smile 11 RA/-B Smile 12 RF/-G Reset button

A22E. Emergency Stop Switch (22-dia./25-dia.) Install in 22-dia. or 25-dia. Panel Cutout. Model Number Structure L M 24A 01

Smile 41 Push-button box with/without emergency stop

D4SL-N /

Safety Switches & Operator Controls

Tina 4A Connection block

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Tina 11A Connection block

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Clicks for Three Easily Discernable Positions

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

Sense7-series Non-contact coded safety switch

D4SL-N /

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

S8JX-N/S8JX-G Series Replacement Brackets

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Model Number Structure

PRODUCT SPECIFICATION. Foot Switches. Series.

Small Limit Switch D4V

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Safety Interlock Switches

Tina 10A/B/C Adaptor unit

Dimension A. Dimension B

MKey9-series Safety Interlock Switch with Guard Locking

Lock and release types. Solenoid: 24 VDC Mechanical lock 2NC/1NO+1NC/1NO M20 D4NL-4EDA-B4-NPT

FMC-1/2 Tina Muting unit

Better Productivity by Standstill and Low-speed Monitoring

Compact plastic limit switches with positive opening mechanism

A22NK. Key-type Selector Switches

Transcription:

Safety-door Switch D4NS CSM_D4NS_DS_E_5_2 Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch Lineup includes three contact models with 2NC/1NO and 3NC contact forms and MBB models in addition to the previous contact forms, and 2NC. M12-connector models are available, saving on labor and simplifying replacement. Standardized gold-clad contacts provide high contact reliability. Applicable to both standard loads and microloads. Variety of metallic heads available. Be sure to read the Safety Precautions on page 10 and the Precautions for All Safety Door Switches. Model Number Structure Model Number Legend Switch (Standard type) D4NS-@@@ 1 2 3 1. Conduit/Connector size 1:Pg13.5 (1-conduit) 2:G1/2 (1-conduit) 4: (1-conduit) 6:G1/2 (2-conduit) 8: (2-conduit) 9:M12 connector (1-conduit) 2. Built-in Switch A: (slow-action) B:2NC (slow-action) C:2NC/1NO (slow-action) D:3NC (slow-action) E: (MBB contact) F:2NC/1NO (MBB contact) 3. Head Mounting Direction F:Four mounting directions possible (Front-side mounting at shipping)/plastic D:Four mounting directions possible (Front-side mounting at shipping)/metal Note: An order for the head part or the switch part alone cannot be accepted. (The Key is sold separately.) Switch (High pull-force type) D4NS-@@F-SJ 1 2 1. Conduit size 2:G1/2 (1-conduit) 4: (1-conduit) 2. Built-in Switch A: (slow-action) B:2NC (slow-action) C:2NC/1NO (slow-action) D:3NC (slow-action) Key D4DS-K@ 1 1. Key Type 1:Horizontal mounting 2:Vertical mounting 3:Adjustable mounting (Horizontal) 5:Adjustable mounting (Horizontal/Vertical) 1

Ordering Information Switches ( Keys are sold separately.) : Models with certified direct opening contacts. Consult with your OMRON representative when ordering any models that are not listed in this table. Type Contact configuration Conduit opening/connector Model Pg13.5 D4NS-1AF * G1/2 D4NS-2AF * D4NS-4AF Pg13.5 D4NS-1BF * 2NC G1/2 D4NS-2BF * Slow-action D4NS-4BF Pg13.5 D4NS-1CF * 2NC/1NO G1/2 D4NS-2CF * 1-Conduit D4NS-4CF Pg13.5 D4NS-1DF * 3NC G1/2 D4NS-2DF * D4NS-4DF Pg13.5 D4NS-1EF G1/2 D4NS-2EF Slow-action MBB contact Pg13.5 D4NS-4EF D4NS-1FF 2NC/1NO G1/2 D4NS-2FF D4NS-4FF G1/2 D4NS-6AF D4NS-8AF 2-Conduit Slow-action 2NC 2NC/1NO 3NC G1/2 D4NS-6BF D4NS-8BF G1/2 D4NS-6CF D4NS-8CF G1/2 D4NS-6DF D4NS-8DF Slow-action MBB contact 2NC/1NO G1/2 D4NS-6EF D4NS-8EF G1/2 D4NS-6FF D4NS-8FF 1-Conduit, with connector Slow-action Slow-action MBB contact 2NC M12 connector D4NS-9AF D4NS-9BF D4NS-9EF G1/2 D4NS-2AF-SJ * D4NS-4AF-SJ * 1-Conduit (High pull-force type) Slow-action * Models with Korean S-mark certification. 2NC 2NC/1NO 3NC G1/2 D4NS-2BF-SJ * D4NS-4BF-SJ * G1/2 D4NS-2CF-SJ * D4NS-4CF-SJ * G1/2 D4NS-2DF-SJ * D4NS-4DF-SJ * 2

Keys Horizontal mounting Type Model D4DS-K1 Vertical mounting D4DS-K2 Adjustable mounting (Horizontal) D4DS-K3 Adjustable mounting (Horizontal/Vertical) D4DS-K5 Specifications Standards and EC Directives Conforms to the following EC Directives: Machinery Directive Low Voltage Directive EN50047 EN60204-1 EN1088 GS-ET-15 Certified Standards Certification body Standard File No. TÜV SÜD EN60947-5-1 (certified direct opening) Consult your OMRON representative for details. UL *1 UL508, CSA C22.2 No.14 E76675 CQC (CCC) GB14048.5 2003010305077330 KOSHA *2 EN60947-5-1 2005-197 *1. Certification for CSA C22.2 No. 14 is authorized by the UL mark. *2. Only certain models have been certified. Certified Standard Ratings TÜV (EN60947-5-1), CCC (GB14048.5) Item Utilization category AC-15 DC-13 Rated operating current (Ie) 3 A 0.27 A Rated operating voltage (Ue) 240 V 250 V Note: Use a 10 A fuse type gi or gg that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch. UL/CSA (UL508, CSA C22.2 No. 14) A300 Rated Current (A) Volt-amperes (VA) Carry current voltage Make Break Make Break 120 VAC 60 6 10 A 7,200 720 240 VAC 30 3 Q300 Rated Current (A) Volt-amperes (VA) Carry current voltage Make Break Make Break 125 VDC 0.55 0.55 2.5 A 69 69 250 VDC 0.27 0.27 3

Characteristics Degree of protection *1 IP67 (EN60947-5-1) Durability *2 Mechanical <Standard type> 1,000,000 operations min. <High pull-force type> 100,000 operations min. Electrical <Standard type> 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) <High pull-force type> 100,000 operations min. (10 A resistive load at 250 VAC) Operating speed 0.05 to 0.5 m/s Direct opening force *4 <Standard type> 60 N min. <High pull-force type> 80 N min. Direct opening travel *4 10 mm min. Contact resistance 25 mω max. Minimum applicable load *5 1 ma resistive load at 5 VDC (N-level reference value) Rated insulation voltage (Ui) 300 V Rated frequency 50/60 Hz Protection against electric shock Class II (double insulation) Pollution degree (operating environment) 3 (EN60947-5-1) Impulse withstand voltage (EN60947-5-1) Between terminals of same polarity Between terminals of different polarity Between each terminal and non-current carrying metallic parts 2.5 kv Insulation resistance 100 MΩ min. Contact gap 2 2 mm min. Vibration resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude Shock resistance Destruction 1,000 m/s 2 min. Malfunction 300 m/s 2 min. Conditional short-circuit current 100 A (EN60947-5-1) Conventional free air thermal current (Ith) 10 A (EN60947-5-1) Ambient operating temperature 30 to 70 C (with no icing) Ambient operating humidity 95% max. Weight Approx. 96 g (D4NS-1CF) 4 kv 6 kv Note: 1. The above values are initial values. 2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. *1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NS in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. *2. The durability is for an ambient temperature of 5 to 35 C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative. *3. Do not pass the 3 A, 250 VAC load through more than 2 circuits. *4. These figures are minimum requirements for safe operation. *5. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand. 4

Structure and Nomenclature Structure D4NS-@A@, D4NS-@B@, D4NS-@E@, D4NS-@AF-SJ, D4NS-@BF-SJ D4NS-@C@, D4NS-@D@, D4NS-@F@, D4NS-@CF-SJ, D4NS-@DF-SJ D4NS key hole Head The head can be mounted in four directions. Sealing properties The switch casing ensures IP67 Terminal Terminal Terminal 12 Terminal 12 Terminal 21 Terminal 22 Terminal 31 (33) Terminal 32 (34) Terminal 31 (33) Terminal 32 (34) Note: The 2-conduit models have the same terminal arrangement. Contact Form Diagrams Show State with Key Inserted. Model Contact Contact form Operating pattern Remarks D4NS-@A@ D4NS-@AF-SJ 33 12 34-12 33-34 Stroke Key insertion Extraction ON Only NC contacts -12 have a certified direct opening mechanism. The terminals -12 and 33-34 can be used as unlike poles. D4NS-@B@ D4NS-@BF-SJ 2NC 31 12 32-12 31-32 Stroke Key insertion Extraction ON NC contacts -12 and 31-32 have a certified direct opening mechanism. The terminals -12 and 31-32 can be used as unlike poles. D4NS-@C@ D4NS-@CF-SJ 2NC/1NO 12 21 22 33 34-12 21-22 33-34 Stroke Key insertion Extraction ON NC contacts -12 and 21-22 have a certified direct opening mechanism. The terminals -12, 21-22, and 33-34 can be used as unlike poles. D4NS-@D@ D4NS-@DF-SJ 3NC 12 21 22 31 32-12 21-22 31-32 Stroke Key insertion Extraction ON NC contacts -12, 21-22, and 31-32 have a certified direct opening mechanism. The terminals -12, 21-22, and 31-32 can be used as unlike poles. D4NS-@E@ MBB * D4NS-@F@ 2NC/1NO MBB * 33 21 12 34 12 22 33 34-12 33-34 Stroke Key insertion -12 21-22 33-34 Stroke Key insertion Extraction Extraction * MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open contact (NO) closes. ON ON Only NC contacts -12 have a certified direct opening mechanism. The terminals -12 and 33-34 can be used as unlike poles. NC contacts -12 and 21-22 have a certified direct opening mechanism. The terminals -12, 21-22 and 33-34 can be used as unlike poles. 5

Dimensions Dimensions and Operating Characteristics 1-Conduit Models D4NS (Unit: mm) D4NS-1@F D4NS-2@F D4NS-4@F D4NS-2@F-SJ D4NS-4@F-SJ Head cap 7.5 30.2 15.3 4.4 30.6 15.5 Operating characteristics Key insertion force Key extraction force Model D4NS-1@F D4NS-2@F D4NS-4@F 15 N max. 30 N max. D4NS-2@F-SJ D4NS-4@F-SJ 15N max. (50N max.) 41 33.5 Pretravel (PT) 6±3 mm 6±3 mm 55 47±0.2 20±0.1 22±0.1 2.5 2.15±0.05R mounting holes 21.5 31.5 Total travel (TT) Direct opening force * Direct opening stroke * (28 mm) 60 N min. 10 mm min. (28 mm) 80N min. 10mm min. * Always maintain the above operating characteristics for safe use. 22±0.2 31 14.2 30 Two, 4 +0.15 0 dia. holes depth: 5 2-Conduit Models D4NS-6@F D4NS-8@F Head cap 7.5 41 33.5 5.4 42±0.1 40±0.1 30.2 15.3 4.4 2.5 9±0.2 31.5 30.6 21.5 15.5 Operating characteristics Key insertion force Key extraction force Pretravel (PT) Model D4NS-6@F D4NS-8@F 15 N max. 30 N max. 6±3 mm Total travel (TT) (28 mm) 47 39±0.2 20.5 20±0.1 25 dia. 22±0.1 Cap (both sides) 2.15±0.05R 14.2 42±0.2 mounting holes Two, 4 +0.15 0 dia. holes 56 max. 3 30 depth: 5 Direct opening force * Direct opening stroke * 60 N min. 10 mm min. * Always maintain the above operating characteristics for safe use. 1-Conduit Connector Models D4NS-9@F Head cap 7.5 30.2 15.3 30.6 15.5 Operating characteristics Model D4NS-9@F 41 33.5 47±0.2 55 (14) 20±0.1 22±0.1 4.4 2.5 2.15±0.05R mounting holes 21.5 31.5 Two, 4 +0.15 0 dia. holes depth: 5 Key insertion force Key extraction force Pretravel (PT) Total travel (TT) Direct opening force * Direct opening stroke * 15 N max. 30 N max. 6±3 mm (28 mm) 60 N min. 10 mm min. * Always maintain the above operating characteristics for safe use. 22±0.2 31 M12 1 14.2 30 Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 2. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before application. 6

Keys D4DS-K1 7 17.5 28 13 4.3 D4DS-K3 4 14 28 9 dia. 8 dia. 4.5 dia. Angle adjustment screw 30 15 13 13 20 30 40 56 7 Four, 2.15R 2 6.3 15 2 D4DS-K2 10.5 6 9 28 7 30 13 15 7 2 4. 3 Four, 2.15R D4DS-K5 20.9 28 4 13 15 24.6 22.5 Angle adjustment screws 41 30 43 55 Mounting Holes (Enlargement) 41 17 15 43 4.5 8 18 6.5 8 1 (7) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 7

With Key Inserted (Relationship between Insertion Radius and Key Hole) D4NS-1@F + D4DS-K1 (with Front-inserted Key) 44 to 46.5 Key Horizontal key R 200 D4NS-1@F + D4DS-K1 (with Top-inserted Key) Horizontal key insertion radius R 200 (15) 44 to 46.5 Key (15) and (33.5) Vertical key R 200 54.5 to 57.0 Key Vertical key insertion radius R 200 (8) and 54.5 to 57.0 Key D4NS-1@F + D4DS-K2 (with Front-inserted Key) 40 to 42.5 Key Horizontal key R 200 D4NS-1@F + D4DS-K2 (with Top-inserted Key) Horizontal key insertion radius R 200 (15) 40 to 42.5 Key (15) and Vertical key R 200 50.5 to 53.0 Key (33.5) (27.5) and (6) Vertical key insertion radius R 200 (8) 50.5 to 53.0 Key Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 8

D4NS-1@F + D4DS-K3 (with Front-inserted Key) 45 to 47.5 Key Horizontal key R 50 D4NS-1@F + D4DS-K3 (with Top-inserted Key) Horizontal key insertion radius R 50 40 45 to 47.5 Key (40±0.15) and (33.5) Vertical key R 200 55.5 to 58.0 Key Horizontal key insertion radius R 200 (8) and 55.5 to 58.0 Key D4NS-1@F + D4DS-K5 (with Front-inserted Key) D4NS-1@F + D4DS-K5 (with Top-inserted Key) 51.9 to 54.4 Key 43 ± 0.1 41 ± 0.1 Horizontal key R 50 51.9 to 54.4 Key (43±0.1) (41±0.1) and Vertical key R 50 62.4 to 64.9 Key Horizontal key insertion radius R 50 (33.5) Horizontal key insertion radius R 50 (8) and 62.4 to 64.9 Key Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 9

Safety Precautions D4NS Refer to the Precautions for All Switches and Precautions for All Safety Door Switches.!CAUTION Electric shock may occasionally occur. Do not use metal connectors or metal conduits. Precautions for Safe Use Do not use the Switch submersed in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch. (The IP67 degree of protection of the Switch specifies the amount of water penetration after the Switch is submerged in water for a certain period of time.) Always attach the cover after completing wiring and before using the Switch. Also, do not turn ON the Switch with the cover open. Doing so may result in electric shock. Do not switch circuits for two or more standard loads (250 VAC, 3 A). Doing so may adversely affect insulation performance. Stopper Installation Do not use a Switch as a stopper. Be sure to install a stopper as shown in the following illustration to ensure that the base of the Key does not strike the Head, and adjust the stopper to be within the setting zone (0.5 to 3 mm) of the base of. Do not subject the Switch to a shock that exceeds the Switch's shock resistance of 1,000 m/s 2. Correct Stopper Incorrect Mounting Holes Use M4 screws and spring washers to mount the Switch and Key, and tighten the screws to a suitable torque. To ensure safety, use screws that cannot be easily removed or another means to prevent the Switch and Key from easily being removed. As shown below, two studs with a maximum height of 4.8 mm and 0.05 a diameter of 4 0.15 mm can be provided, the studs inserted into the holes on the bottom of the Switch, and the Switch secured at four locations to increase the mounting strength. Switch Mounting Holes and Studs 1-Conduit Modules 2.5±0.1 47±0.1 Two, M4 20±0.1 22±0.1 22±0.1 2-Conduit Modules 5.35±0.1 2.5±0.1 Two, M4 20±0.1 4-0.05-0.15 dia. Height: 4.8 max. Key Mounting Holes Horizontal/Vertical Mounting (D4DS-K1/-K2) 15±0.1 Two, M4 Horizontal Adjustable Mounting (D4DS-K3) 40±0.1 Two, M4 Horizontal/Vertical Adjustable Mounting (D4DS-K5) 41±0.1 or, 43±0.1 Two, M4 22±0.1 39±0.1 40±0.1 42±0.1 key Switch Precautions for Correct Use The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. Mounting Method Appropriate Tightening Torque Loose screws may result in malfunction. Tighten the screws to the specified torques. Terminal screw 0.6 to 0.8 N m Cover mounting screw 0.5 to 0.7 N m Head mounting screw 0.5 to 0.6 N m Key mounting screw 2.4 to 2.8 N m Body mounting screw 0.5 to 0.7 N m Connector 1.8 to 2.2 N m Cap screw 1.3 to 1.7 N m When loosening a screw with an electrical screwdriver or similar tool while pressing down on the screw head, do not continue turning the screw past the point where the threads disengage. Doing so may strip the end of the threads. 42±0.1 4-0.05-0.15 dia. Height: 4.8 max. Set so that it is within 1 mm of the center of the key hole. If is offset or at an angle, accelerated wear or breaking may result. Observe the specified for and insert it in a direction perpendicular to the key hole. Head Direction The rotation of the Switch head may be adjusted to any of the four directions by loosening the head mounting screws at the four corners of the head. Make sure that no foreign materials enter through the head. Do not insert or remove with the Switch head removed. Doing so may make it impossible to insert the Key. Securing the Door When the door is closed (with inserted), the Key may exceed the set zone because of, for example, the door's own weight, machine vibration, or the door cushion rubber. Secure the door with a stopper so that remains within the set zone. Set zone (0.5 to 3 mm) Key 10

Wiring Wiring When connecting with insulation tubes and M3.5 crimp terminals, connect the terminals as shown in the following figure and wire without overriding to the case and the cover. Adequate conductor size is AWG 20 to AWG18 (0.5 to 0.75 mm 2 ). Prepare lead wires using the lengths given in the following diagrams. If lead wires are too long, they will press against the cover causing the cover to not close properly. 1-Conduit Models with 3 Poles A C E 12 21 22 33 34 2-Conduit Models with 3 Poles A C E 12 21 22 33 34 A B C D E F Do not push the crimp terminal and the likes into the opening between the parts to prevent the case from being broken and deformed. Use terminals having the thickness of 0.5 mm or less to avoid the contact between the terminal and the Switch case inside. <Reference> The crimp terminals listed below have a thickness of 0.5 mm or less. Manufacture Type J.S.T. Mfg Co. FN0.5-3.7 (F Type) N0.5-3.7 (Straight Type) J.S.T is a Japanese manufacturer. B D F B D 42 mm F t: 0.5 mm dz dia.: 3.7 mm D dia.: 2.9 mm B: 6.6 mm L: 19 mm D dia. F: 7.7 mm I: 8.0 mm Terminal screw E C A Left hand BDF l 42 mm 33 mm 28 mm Tolerance ±2 mm 28 mm Tolerance ±2 mm L F BDF Right hand E C A 28 mm dz dia. B 42 mm Tolerance ±2 mm Pin arrangement of connector type 1 2 4 3 Suitable socket is XS2F-D421 series (OMRON). Refer to the Connector Catalog for corresponding Socket pin numbers and lead wire colors. Socket Tightening (Models with Connectors) Turn the tightening screws on the Socket by hand and tighten them until the gap between the Socket and Plug essentially disappears. Make sure that the Socket s connector is tightened securely, otherwise the rated degree of protection (IP67) of the D4NS may not be maintained, or the Socket connector may be loosened by vibration. Conduit Opening Use cables with suitable diameters for the connector being used. When wiring, place the enclosed cap screw on unused conduit openings (for 2-Conduit Switches) and tighten them to the suitable tightening torque. Recommended Connectors Use the connector with thread section of 9 mm long or less. If a connector with a longer thread section is used, the protruding part may interfere with the other parts inside the body. Use the connectors listed below to ensure IP67 degree of protection. Size Manufacture Model G1/2 LAPP Pg13.5 D4NS-9BF (2NC) 1 () 3 (31) LAPP LAPP 2 (12) 4 (32) ST-PF1/2 5380-1002 S-13.5 5301-5030 ST- 1.5 53-1020 D4NS-9AF () D4NS-9EF ( (MBB)) 1 () 3 (33) Pin No. (Terminal No.) 2 (12) 4 (34) Applicable cable diameter 6.0 to 12.0 mm 6.0 to 12.0 mm 7.0 to 13.0 mm When use LAPP's products, use together with a Seal Packing which is sold separately (Type names, JPK-16, GP-13.5, or GP) and tighten with proper tightening torque. LAPP is a German manufacturer. Crimp terminal Correct Incorrect

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2012.1 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2012 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: D4NS-1BF D4NS-4DF D4NS-2EF D4NS-8CF D4NS-9AF D4NS-9BF D4NS-K61 D4NS-2AF